• Title/Summary/Keyword: Validity (Epidemiology)

Search Result 33, Processing Time 0.031 seconds

Reliability and Validity of a Nationwide Survey (the Korean Radiation Workers Study)

  • Lee, Dalnim;Lim, Wan Young;Park, Soojin;Jin, Young Woo;Lee, Won Jin;Park, Sunhoo;Seo, Songwon
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.445-451
    • /
    • 2021
  • Background: This study aimed to evaluate the reliability and validity of the self-administered questionnaire for Korean radiation workers. Methods: From May 24, 2016, to June 30, 2017, 20,608 participants completed the questionnaire, providing information on sociodemographics, lifestyle, work history and practices, medical radiation exposure, and medical history, which was linked to the National Dose Registry and the National Cancer Registry. The validity of the questionnaire was evaluated using the responses of 20,608 workers, and reliability was evaluated using the responses of 3043 workers who responded to the survey twice. Results: Responses concerning demographic characteristics and lifestyle showed reliability with a moderate-to-high agreement (kappa: 0.43-0.99), whereas responses concerning occupation and medical radiation exposure had a wide range of agreement (kappa: 0.05-0.95), possibly owing to temporal variability during employment. Regarding validity, responses to the question about the first year of employment had an excellent agreement with the national registry (intraclass correlation coefficient = 0.9); however, responses on cancer history had a wide range of agreement (kappa: 0.22-0.85). Conclusion: Although the reliability and validity of the questionnaire were not distinguished by demographic characteristics, they tended to be low among participants whose occupational radiation exposure was minimal. Overall, the information collected can be reliable for epidemiological studies; however, caution must be exercised when using information such as medical exposure and work practices, which are prone to temporal variability.

A SELF-ADMINISTERED QUALITY-OF-LIFE QUESTIONNAIRE AFTER ACUTE MYOCARDIAL INFARCTION

  • Lim L. L-Y.;Valenti L.A.;Knapp J.C.;Dobson A.J.;Plotnikoff R.;Higginbotham N.;Heller R.F.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.180-187
    • /
    • 1994
  • A slightly modified version of the Quality-of-Life after Myocardial Infarction (QLMI) questionnaire developed by Oldridge and colleagues was applied in a self-administered mode to patients with suspected acute myocardial infarction (AMI) in a randomized controlled trial of secondary prevention. Acceptability of the questionnaire was good, with 93% of responders answering all items. Factor analysis suggested three quality-of-life (QL) dimensions which we called 'emotional', 'physical' and 'social'. These differed somewhat from the dimensions proposed by Oldtidge and colleagues. However, a sensitivity analysis showed relative invariance of results to weighting schemes. Scores on our three dimensions were responsive to differences between the treatment groups, and demonstrated construct validity based on associations between the measured QL and variables expected to affect QL. We conclude that the QLMI questionnaire has good potential as an instrument for assessing QL in post-AMI patients and that it can be successfully self-administered.

  • PDF

Validity Assessment of the Persian Version of the Nordic Safety Climate Questionnaire (NOSACQ-50): A Case Study in a Steel Company

  • Yousefi, Yadolah;Jahangiri, Mehdi;Choobineh, Alireza;Tabatabaei, Hamidreza;Keshavarzi, Sareh;Shams, Ali;Mohammadi, Younes
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.326-330
    • /
    • 2016
  • Background: The Nordic Safety Climate Questionnaire-50 (NOSACQ-50) was developed by a team of Nordic occupational safety researchers based on safety climate and psychological theories. The aim of this study was to develop and validate the Persian version of NOSACQ-50 and assess the score of safety climate on a group of workers in a steel company in Iran. Methods: The Persian version of NOSACQ-50 was distributed among 661 employees of a steel company in Qazvin Province (Iran). Exploratory factor analysis (EFA) and confirmatory factor analysis were used to determine the dimensions of the questionnaire. The reliability of the questionnaire was assessed using Cronbach ${\alpha}$ coefficient. Pearson correlation test was applied to investigate the correlation between different dimensions. Results: The results of EFA showed that the Persian version of NOSACQ-50 consisted of six dimensions. The Cronbach ${\alpha}$ coefficient of the questionnaire was 0.94. The mean score of safety climate in all dimensions was 2.89 (standard deviation 0.60). Conclusion: The Persian version of NOSACQ-50 had a satisfactory validity for measuring safety climate in the studied Iranian population.

Psychometric Properties of the Persian Version of Satisfaction with Care EORTC-in-patsat32 Questionnaire among Iranian Cancer Patients

  • Pishkuhi, Mahin Ahmadi;Salmaniyan, Soraya;Nedjat, Saharnaz;Zendedel, Kazem;Lari, Mohsen Asadi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10121-10128
    • /
    • 2015
  • Background: Cancers impose an increasing burden on health of the populations and individuals, but little is known about cancer patient satisfaction with care. The aim of this study was to assess the psychometric properties of the Persian version of European Organisation for Research and Treatment of Cancer (EORTC) In-Patsat32, as a recently developed questionnaire to assess cancer patient satisfaction with care and information provided during hospital admission. Materials and Methods: Complying with EORTC protocols, the Persian version of Inpatsat32 was translated and piloted in a small group of patients, then applied to 380 cancer patients admitted to different oncology wards in Tehran. Validity (convergent, discriminant, and divergent) and reliability of the tool was assessed through using multitrait analysis, factor analysis, intraclass correlations, Chronbach's alpha and test-retest (on a sample of 70 patients). Results: Good acceptance and high sensitivity of the questionnaire with low floor and ceiling effects were recognized, indicating power of the instrument to detect differences between groups with heterogeneous levels of satisfaction. Multitrait scaling analyses supported the convergent validity of the majority of scales (correlation coefficient >0.4) and favorable discriminant validity (item own scale correlation >0.8). There was no correlation between In-patsat32 scales and the EORTC-C30, which measures different concepts, confirming divergent validity of the tool. Internal consistency for all domains was high (${\alpha}$ >0.70) except for the hospital access score and the test-retest reliability was excellent (r=0.86-0.96). There was a weak responsiveness to change except for nurses technical skills. Principle component analysis confirmed five domains with much improved internal consistency (${\alpha}$ >0.9). Conclusions: The Persian version of the EORTC-in-patsat32 module is a reliable and valid instrument to measure cancer patient satisfaction with care received during their hospitalization period and can be utilized in clinical cancer research.

Psychometric Analysis of a Persian Version of the European Organization for Research and Treatment of Cancer OG25 Quality of Life Questionnaire in Oesophagogastric Cancer Patients

  • Hesari, Ali Esmaeili;Lari, Mohsen Asadi;Shandiz, Fatemeh Homai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2739-2745
    • /
    • 2014
  • Background: Health-related quality of life (HRQL) is a fundamental outcome in oncology patients and quality of life (QOL) assessment requires clinically relevant questionnaires. The purpose of this study was translation and definition of measurement properties and the clinical validity of Quality of Life Questionnaire (QLQ)-OG25 module in Persian patients with oesophagus, oesophagogastric junction (OGJ) or gastric cancers. Materials and Methods: The translation procedure followed European Organization for Research and Treatment of Cancer (EORTC) guidelines. Both EORTC QLQ-OG25 and a core questionnaire (EORTC QLQ-C30) were administered to patients with oesophagus (150), OG junction (93) and gastric (32) cancer undergoing multi-modal treatments. Convergent and discriminant validity, Cronbach's alpha coefficient and known-groups comparisons were used to examine reliability and validity. Results: In all, 275 patients (mean age 62 years) completed both questionnaires. Compliance rate was high and the questionnaire module was well accepted. We found good reliability for multi-item subscales of QLQ-OG25 (Cronbach's alpha coefficients 0.76-0.89). About 73% had TNM staging and scales distinguished between clinically distinct groups of patients. However, patients in palliative group experienced compromised functional status and worse treatment-associated symptoms than those in the potentially curative group. Test-retest scores were consistent. Multi-trait scaling analysis demonstrated good convergent and discriminant validity. Conclusions: Overall, the Persian version of QLQ-OG25 demonstrated psychometric and clinical validity that supports its application as a supplement to the original tool (EORTC QLQ-C30) when assessing HRQL in patients with upper-gastrointestinal (GI) cancer both in curative and palliative phases.

Genetic radiation risks: a neglected topic in the low dose debate

  • Schmitz-Feuerhake, Inge;Busby, Christopher;Pflugbeil, Sebastian
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.1.1-1.13
    • /
    • 2016
  • Objectives To investigate the accuracy and scientific validity of the current very low risk factor for hereditary diseases in humans following exposures to ionizing radiation adopted by the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection. The value is based on experiments on mice due to reportedly absent effects in the Japanese atomic bomb (A-bomb) survivors. Methods To review the published evidence for heritable effects after ionising radiation exposures particularly, but not restricted to, populations exposed to contamination from the Chernobyl accident and from atmospheric nuclear test fallout. To make a compilation of findings about early deaths, congenital malformations, Down's syndrome, cancer and other genetic effects observed in humans after the exposure of the parents. To also examine more closely the evidence from the Japanese A-bomb epidemiology and discuss its scientific validity. Results Nearly all types of hereditary defects were found at doses as low as one to 10 mSv. We discuss the clash between the current risk model and these observations on the basis of biological mechanism and assumptions about linear relationships between dose and effect in neonatal and foetal epidemiology. The evidence supports a dose response relationship which is non-linear and is either biphasic or supralinear (hogs-back) and largely either saturates or falls above 10 mSv. Conclusions We conclude that the current risk model for heritable effects of radiation is unsafe. The dose response relationship is non-linear with the greatest effects at the lowest doses. Using Chernobyl data we derive an excess relative risk for all malformations of 1.0 per 10 mSv cumulative dose. The safety of the Japanese A-bomb epidemiology is argued to be both scientifically and philosophically questionable owing to errors in the choice of control groups, omission of internal exposure effects and assumptions about linear dose response.

Evaluating the Validity of the Pediatric Index of Mortality Ⅱ in the Intensive Care Units (소아중환자를 대상으로 한 PIM Ⅱ의 타당도 평가)

  • Kim, Jung-Soon;Boo, Sun-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.1
    • /
    • pp.47-55
    • /
    • 2005
  • Purpose: This study was to evaluate the validity of the Pediatric Index of Mortality Ⅱ(PIM Ⅱ). Method: The first values on PIM Ⅱ variables following ICU admission were collected from the patient's charts of 548 admissions retrospectively in three ICUs(medical, surgical, and neurosurgical) at P University Hospital and a cardiac ICU at D University Hospital in Busan from January 1, 2002 to December 31, 2003. Data was analyzed with the SPSSWIN 10.0 program for the descriptive statistics, correlation coefficient, standardized mortality ratio(SMR), validity index(sensitivity, specificity, positive predictive value, negative predictive value), and AUC of ROC curve. Result: The mortality rate was 10.9% (60 cases) and the predicted death rate was 9.5%. The correlation coefficient(r) between observed and expected death rates was .929(p<.01) and SMR was 1.15. Se, Sp, pPv, nPv, and the correct classification rate were .80, .96, .70, .98, and 94.0% respectively. In addition, areas under the curve (AUC) of the receiver operating characteristic(ROC) was 0.954 (95% CI=0.919~0.989). According to demographic characteristics, mortality was underestimated in the medical group and overestimated in the surgical group. In addition, the AUCs of ROC curve were generally high in all subgroups. Conclusion: The PIM Ⅱ showed a good, so it can be utilized for the subject hospital. better.

Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

  • Shirali, Gholamabbas;Shekari, Mohammad;Angali, Kambiz Ahmadi
    • Safety and Health at Work
    • /
    • v.9 no.3
    • /
    • pp.296-307
    • /
    • 2018
  • Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

Comparison of Validity of Food Group Intake by Food Frequency Questionnaire Between Pre- and Post-adjustment Estimates Derived from 2-day 24-hour Recalls in Combination with the Probability of Consumption

  • Kim, Dong-Woo;Oh, Se-Young;Kwon, Sung-Ok;Kim, Jeong-Seon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2655-2661
    • /
    • 2012
  • Validation of a food frequency questionnaire (FFQ) utilising a short-term measurement method is challenging when the reference method does not accurately reflect the usual food intake. In addition, food group intake that is not consumed on daily basis is more critical when episodically consumed foods are related and compared. To overcome these challenges, several statistical approaches have been developed to determine usual food intake distributions. The Multiple Source Method (MSM) can calculate the usual food intake by combining the frequency questions of an FFQ with the short-term food intake amount data. In this study, we applied the MSM to estimate the usual food group intake and evaluate the validity of an FFQ with a group of 333 Korean children (aged 3-6 y) who completed two 24-hour recalls (24HR) and one FFQ in 2010. After adjusting the data using the MSM procedure, the true rate of non-consumption for all food groups was less than 1% except for the beans group. The median Spearman correlation coefficients against FFQ of the mean of 2-d 24HRs data and the MSM-adjusted data were 0.20 (range: 0.11 to 0.40) and 0.35 (range: 0.14 to 0.60), respectively. The weighted kappa values against FFQ ranged from 0.08 to 0.25 for the mean of 2-d 24HRs data and from 0.10 to 0.41 for the MSM-adjusted data. For most food groups, the MSM-adjusted data showed relatively stronger correlations against FFQ than raw 2-d 24HRs data, from 0.03 (beverages) to 0.34 (mushrooms). The results of this study indicated that the application of the MSM, which was a better estimate of the usual intake, could be worth considering in FFQ validation studies among Korean children.

Coverage, Density and Completeness of Sources used in Tehran Metropolitan Area Cancer Registry: According to the Data of Esophageal Cancer, 2003-2007

  • Aghaei, Abbas;Najafi, Farid;Mosavi-Jarrahi, Alireza;Ahmadi-Jouibari, Toraj
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3617-3619
    • /
    • 2012
  • Background: The completeness of cancer registration is a major validity index of any reported cancer incidence. The present study aimed to evaluate the esophageal cancer incidence registered in the Tehran Metropolitan Area Cancer Registry. Materials and methods: The data on esophageal cancer abstracted from three sources of 1) pathology departments, 2) medical records, and 3) death certificates during 2003 till 2007 were utilized. The completeness of the data sources were evaluated using coverage (defined as the proportion of a community population with esophageal cancer identified by the source) and density (defined as the proportion of non-empty fields of the data by source). Results: A total 1,404 cases of esophageal cancer were reported for the duration of the study. Pathology provided 771, medical records 432, and death certificates 609. The coverage was 0.55 for pathology, 0.31 for medical records, and 0.43 for death certificates. The respective density values were 0.82, 0.96 and 0.98, respectively. Pathology (0.45) was the most complete source followed by medical records (0.42), and death certificates (0.29). Discussion: A low degree of completeness dictates putting more effort into case finding plus abstracting data more thoroughly.