• Title/Summary/Keyword: Validation Rate

Search Result 733, Processing Time 0.035 seconds

Residence s Exposure to Nitrogen Dioxide and Indoor Air Characteristics (거주지역 실내공기 특성 및 이산화질소 노출에 관한 연구)

  • 양원호;배현주;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.183-192
    • /
    • 2002
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level and so on. Although technologies exist to measure these factors directly, direct measurements of all factors are impractical in most field studies. The purpose of this study was to develop an alternative methods to estimate these factors by multiple measurements. Daily indoor and outdoor NO$_2$concentrations for 21 days in 20 houses in summer and winter, Seoul. Using a mass balance model and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor(emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the ventilation and source strength were estimated. During sampling period, geometric mean of natural ventilation was estimated to be 1.10$\pm$1.53 ACH, assuming a residential NO$_2$decay rate of 0.8 hr$^{-1}$ in summer. In winter, natural ventilation was 0.75$\pm$1.31 ACH. And mean source strengths in summer and winter were 14.8ppb/hr and 22.4ppb/hr, respectively. Although the method showed similar finding previous studies, the study did not measure ACH or the source strength of the house directly. As validation of natural ventilations, infiltrations were measured with $CO_2$tracer gas in 18 houses. Relationship between ventilation and infiltration was statistically correlated (Pearson r=0.63, p=0.02).

Infrared Rainfall Estimates Using the Probability Matching Method Applied to Coincident SSM/I and GMS-5 Data

  • Oh, Hyun-Jong;Sohn, Byung-Ju;Chung, Hyo-Sang
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.117-121
    • /
    • 1999
  • Relations between GMS-5 infrared brightness temperature with SSM/I retrieved rain rate are determined by a probability matching method similar to Atlas et al. and Crosson et al. For this study, coincident data sets of the GMS-5 infrared measurements and SSM/I data during two summer seasons of 1997 and 1998 are constructed. The cumulative density functions (CDFs) of infrared brightness temperature and rain rate are matched at pairs of two variables which give the same percentile contribution. The method was applied for estimating rain rate on 31 July 1998, examining heavy rainfall estimation of a flash flood event over Mt. Jiri. Results were compared with surface gauge observations run by Korean Meteorological Administration. It was noted that the method produced reasonably good quality of rain estimate, however, there was large area giving false rain due to the anvil type clouds surrounding deep convective clouds. Extensive validation against surface rain observation is currently under investigation.

  • PDF

Modeling and prediction of rapid pollution of insulators in substations based on weather information

  • Nanayakkara, Nishantha;Nakamura, Masatoshi;Goto, Satoru;Taniguchi, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.202-206
    • /
    • 1994
  • Mathematical model of the pollution rate of substation insulators is constructed, taking the model parameters as wind speed, wind direction, typhoon conditions and rainfall in an hourly basis. The main feature of model construction is to distinguish the effect of each parameter by separately analyzing the positive and negative pollution causing factors. Model parameters for the insulators of Karatsu substation, Saga, Japan were estimated and model validation was done using the actual data, in which the pollution deposits on the insulators were measured using pilot insulator and 'salt meter'. The proposed model of the pollution rate [mg/cm$^{2}$/hr] enables the identification of the effective parameters and prediction of the pollution rate so that it helps for the automatic decision making for insulator cleaning or the model can be used as a tool for the substation engineers to make precautionary measures.

  • PDF

A Study on the Numerical Prediction of Cavitation In a Centrifugal Pump (원심펌프 내부의 캐비테이션 수치예측에 관한 연구)

  • Mo, J.O.;Kang, S.J.;Kang, H.K.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.335-338
    • /
    • 2006
  • A Numerical study of the cavitation within a centrifugal pump is carried out using CFD commercial code, FLUENT. The objective of this study is to predict the onset of cavitation within the pump blade and the degradation in the pressure rise due to the generation and transport of vapor. A pump designed for the study is a six bladed, one-circular arc impeller design suggested by A.J. Stepanoff et al. The Steady-state calculations are performed for a wide range of flow rate without the cavitation to investigate the pump performance. The design head and efficiency show a very good agreement with the numerical results at the design flow rate. After the validation with the numerical results, the pump performance and the onset of cavitation within the blade is predicted by changing NPSH at the design flow rate.

  • PDF

Minimum Specific Airflow Rate Requirements for Natural Air Drying of Rough Rice in Korea (벼 상온통풍건조의 최소풍량비에 관한 연구)

  • 금동혁;박선태
    • Journal of Biosystems Engineering
    • /
    • v.21 no.1
    • /
    • pp.60-71
    • /
    • 1996
  • The purposes of this study were to develop a simulation model and to determine minimum specific airflow rate requirements for natural air drying of rough rice in Korea. A simulation model was developed considering energy and mass balances within grain bed, drying and rewetting rates, and hysterisis effect between sorption and desorption isotherms. As the results of validation test, the moisture contents predicted by the model agreed very well with the actual data. The criteria for determining minimum specific airflow rate requirements was that the top loom layer in the bin be dried to a moisture content below 16 percent wet basis with less than 0.5% drymatter decomposition. The minimum specific airflow rate requirements in 13 locations of Korea were presented based on the worst one among the past 7 to 13-year weather data. These requirements were also presented for all the combinations of three harvest dates and four harvest moisture contents. Specific airflow rate requirements seemed to be half by each 2 percent reduction in moisture content from 24 percent. As harvest date was delayed by 10 days from October 1, these requirements were reduced by about 20 to 40 percent.

  • PDF

Failure Rate Model of External Environment Maintenance for a System under Severe Environment (가혹환경 하에서 사용되는 시스템의 외부환경보수에 대한 고장률 모형)

  • Park, J.H.;Shin, Y.J.;Lee, S.C.;Lie, C.H.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.36 no.1
    • /
    • pp.69-77
    • /
    • 2010
  • The failure rate model of External Environment Maintenance(EEM) for a system under severe environment is investigated. EEM, which is recently introduced concept, is a maintenance activity controlling external environment factors that potentially cause system failure such as cleaning equipment, controlling temperature (humidity) and removing dust inside of electronic appliances. EEM can not have any influence on the inherent failure rate of a system but reduce the severity of the external environment causing failure since it deals with only external environment factors. Therefore, we propose two failure rate models to express the improvement effect of EEM: The intensity reduction model and age reduction model. The intensity and age reduction models of EEM are developed assuming the quality of improvement effect is proportioned to an extra intensity or age respectively. The validation of proposed failure rate models is performed in order of data generation, parameter estimation and test for goodness-of-fit.

Optimal bandwidth in nonparametric classification between two univariate densities

  • Hall, Peter;Kang, Kee-Hoon
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.05a
    • /
    • pp.1-5
    • /
    • 2002
  • We consider the problem of optimal bandwidth choice for nonparametric classification, based on kernel density estimators, where the problem of interest is distinguishing between two univariate distributions. When the densities intersect at a single point, optimal bandwidth choice depends on curvatures of the densities at that point. The problem of empirical bandwidth selection and classifying data in the tails of a distribution are also addressed.

  • PDF

비모수적 회귀함수 추정에서 평활량의 선택에 관한 연구

  • 석경하
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.1
    • /
    • pp.39-49
    • /
    • 1996
  • 비모수적 커널 회귀함수 추정법에서 평활량(bandwidth of smoothing parameter)의 선택은 아주 중요한 문제이다. 교차타당성(cross-validation) 방법에 의한 평활량은 최적평활량으로의 상대적 수렴속도(relative convergence rate)가 $n^{-1/10}$로 상당히 느리다는 것을 알고 있다. 본 연구는 삽입방법(plug-in method)에 의해 선택된 평활량의 상대적 수렴속도가 교차타당성 방법보다 더 빠른 $n^{-2/7}$이 됨을 보였다. 그리고 모의실험을 통하여 소 표본에서도 삽입방법이 교차타당성 방법보다 우수함을 입증하였다.

  • PDF

Experimental technique for efficiency transfer along different geometries and volumes

  • Haddad, Kh;AL-Homyed, A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.695-698
    • /
    • 2021
  • Efficiency calibration is a fundamental procedure in gamma spectrometric measurement. Experimental technique for efficiency calibration transfer in gamma spectrometer along different geometries and volumes has been developed and validated in this work. The developed technique offers simple and easy procedures to overcome several problems encountered in efficiency calibration of gamma spectrometer such as rate-related correction and different sample volumes. The validation shows that application of the developed technique has a precision of 95%.

Research on mechanism of gas leakage in microchannels of steel containment vessels for nuclear power plants

  • Min He;Yueyao Chen;Zhen Wu;Gangling Hou;Jialong Wang;Zhuangfei Li;Yuzhu Wang;Hanze Li
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3030-3042
    • /
    • 2024
  • Steel containment vessels for nuclear power plants can experience gas leakage due to minute defects such as cracks, corrosion, and aging, leading to gas leakage. A gas leakage model for microchannels is established to elucidate the mechanism underlying gas leakage within microchannels caused by these defects, specifically addressing the issue of unidirectional gas flow. Computational Fluid Dynamics (CFD) and the UK R6 method are employed to calculate the gas leakage rate within microchannels. Furthermore, the characteristics of gas flow within microchannels are explored, including the factors affecting the gas leakage rate. Validation of the calculation results is verified experimentally. The results indicate that the gas mass flow rate exhibits a linear decrease with decreasing internal pressure and a non-linear decline as temperature increases. Additionally, the gas mass flow rate demonstrates a negative correlation with the microchannel length but a positive association to its hydraulic diameter. The primary influencing factors on gas leakage rates are hierarchically ranked as follows: pressure difference, microchannel cross-sectional area, temperature, microchannel length, and microchannel hydraulic diameter.