• Title/Summary/Keyword: Vacuum therapy

Search Result 56, Processing Time 0.023 seconds

Role of Endoscopic Vacuum Therapy as a Treatment for Anastomosis Leak after Esophageal Cancer Surgery

  • Lee, Dong Kyu;Min, Yang Won
    • Journal of Chest Surgery
    • /
    • v.53 no.4
    • /
    • pp.205-210
    • /
    • 2020
  • Esophageal anastomotic leak is the most common and serious complication following esophagectomy. However, the standard treatment for anastomotic leaks remains unclear. Recently, endoscopic vacuum therapy has become an important non-surgical alternative treatment method for patients with esophageal anastomotic leak. This treatment involves the endoscopic placement of a sponge connected to a nasogastric tube into the defect cavity or lumen. Subsequently, continuous negative pressure is delivered to the cavity through the tube. Several studies have reported a treatment success rate of 80% to 100%. In this study, we review the mechanism of action, the method of performing the procedure, its safety and efficacy, and prognostic factors for failure of endoscopic vacuum therapy in the management of patients with anastomotic leak, and on this basis attempted to confirm the possibility of establishing a standardized treatment protocol using endoscopic vacuum therapy.

Surgical versus Vacuum Bell Therapy for the Correction of Pectus Excavatum: A Comparison of 1-Year Treatment Outcomes

  • Jung, Younggi;Yi, Eunjue;Lee, Kwanghyoung;Chung, Jae Ho;Cho, Seonghyun;Lee, Sungho
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.473-479
    • /
    • 2021
  • Background: The purpose of this study was to compare 1-year clinical outcomes between patients who underwent a Nuss operation or vacuum bell therapy and to present vacuum bell therapy as a possible alternative treatment modality for patients who prefer non-surgical correction of pectus excavatum. Methods: We conducted a retrospective review of pectus excavatum patients who had undergone vacuum bell therapy for more than 1 year and examined patients who had undergone Nuss bar removal more than 1 year previously. The treatment outcomes were evaluated by comparing changes in the Haller index before and after treatment in both patient groups. Results: We included 57 patients in this study and divided them into 2 groups according to the type of treatment received. Both groups showed no significant difference in the post-treatment Haller index after 1 year of follow-up, although the Nuss operation group showed a greater change in the Haller index than the vacuum bell group. Conclusion: Although the Nuss operation is a well-established and effective treatment of choice to correct pectus excavatum, vacuum bell therapy showed comparable outcomes and could become an alternative treatment modality for select patients who prefer non-invasive treatment.

Vacuum-assisted Closure Therapy for Treating Patients with Severe Subcutaneous Emphysema (피하기종의 Vacuum-assisted Closure Therapy)

  • Oh, Tak-hyuk;Lee, Sang Cjeol;Lee, Deok Heon;Cho, Joon Yong
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.276-279
    • /
    • 2015
  • Subcutaneous emphysema is a benign condition following trauma (pneumothorax and oropharyngeal), cervical or thoracic procedures, and mediastinal infection. However, severe subcutaneous emphysema may be related to serious complications such as respiratory failure, airway compromise, and tension- related phenomena. Many alternative therapies have been tried to treat patients with this condition. We report our experience with vacuum-assisted closure therapy for treating patients with severe subcutaneous emphysema.

  • PDF

Esophageal Endoscopic Vacuum Therapy with Enteral Feeding Using a Sengstaken-Blakemore Tube

  • Lee, So Young;Kim, Kun Woo;Lee, Jae-Ik;Park, Dong-Kyun;Park, Kook-Yang;Park, Chul-Hyun;Son, Kuk-Hui
    • Journal of Chest Surgery
    • /
    • v.51 no.1
    • /
    • pp.76-80
    • /
    • 2018
  • Early diagnosis followed by primary repair is the best treatment for spontaneous esophageal perforation. However, the appropriate management of esophageal leakage after surgical repair is still controversial. Recently, the successful adaptation of vacuum-assisted closure therapy, which is well established for the treatment of chronic surface wounds, has been demonstrated for esophageal perforation or leakage. Conservative treatment methods require long-term fasting with total parenteral nutrition or enteral feeding through invasive procedures, such as percutaneous endoscopic gastrostomy or a feeding jejunostomy. We report 2 cases of esophageal leakage after primary repair treated by endoscopic vacuum therapy with continuous enteral feeding using a Sengstaken-Blakemore tube.

Successful Endoscopic Vacuum Therapy for Extensive Gastric Tubing Necrosis after Ivor-Lewis Esophagectomy: A Case Report

  • Hee Kyung Kim;Hyun Woo Jeon
    • Journal of Chest Surgery
    • /
    • v.56 no.5
    • /
    • pp.362-366
    • /
    • 2023
  • The stomach has become the most commonly used site for grafts to replace the esophagus in esophageal cancer surgery because of its good blood supply and ability to enable single-reconstruction anastomosis. However, anastomotic failure is a serious complication after esophageal cancer surgery. Unlike anastomotic leakage due to local ischemia, gastric tube necrosis is a life-threatening condition with a high mortality rate. Gastric tube necrosis involves extensive ischemia due to a decreased blood supply, and an urgent operation is mandatory in most cases. Endoscopic vacuum therapy (EVT) has been used for anastomotic leakage after esophageal surgery. In recent years, it has been successfully used for more extensive disease, including large esophageal perforation as an indication for reoperation. Hence, we report a case of extensive gastric tube necrosis treated by EVT after an Ivor Lewis operation.

Body Stereotatic Radiosurgery Procedure of Base on Image Guided (Image Guided에 기초한 Body Stereotatic Radiosurgery의 과정)

  • Choi Yun-Kyeung;Lee Doo-Hyun;Cho Jung-Keun;Kim Jong-Won;Youm Doo-Seok;Kim Tae-Yoon;Choi Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.95-103
    • /
    • 2005
  • Purpose : In the radiosurgery, to obtain CT image to find more accurate tumor position during respiration, and using them, to increase the accuracy of radiation treatment by applying image guided. Materials and Methods : Using the self-made vacuum cushion for the body SRS, CT images were obtained three for each patient during respiration (shallow, inhalation, exhalation). They were transformed to the RTP computer and then were fused. Global GTVs were delineated on the fused images and more appropriated treatment planning was established. Results : We can find the tumor position is moving toward cranio-caudal with max 10 mm margin and volume is transformed. As a result from the comparision of DVH (pre & post radio surgery), we observed about 100% dose to tumor. Conclusion : BSRS was skeptical due to the tumor movement during respiration. More accurate by the combination of the development of immobilization devices and BSRS based on Image Guide, it will be applied to more cases for BSRS.

  • PDF

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF

Synthesis and Characterization of Upconversion Nanoparticles for Cancer Therapy

  • Choe, Seung-Yu;Kim, Bo-Bae;Kim, Eun-Bi;Lee, Seung-U;Jeon, Seon-A;Park, Tae-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.420.2-420.2
    • /
    • 2016
  • Various fields have been paid attention to upconversion nanoparticles (UCNPs) because of its unique optical properties. Moreover, to use the UC luminescent techniques through cell images for identified apoptosis/necrosis of cancer cells have been performed. They have been studied for a versatile biomedical application such as a biosensing tool, or delivery of active forms of medicines inside living cells. UCNPs have distinctive characteristics such as photoluminescence, special emission, low background fluorescence signal and good colloidal stability, which have many advantages compared with the organic dyes and quantum dots. UCNPs have not only a great potential for imaging (UC luminescence) but also therapies (photo-thermal therapy, PTT and photo-dynamic therapy, PDT) in cancer diagnostics. Therefore, we report the enhancement of upconversion red emission in NaYF4:Yb3+,Er3+ nanoparticles, synthesized via solid-state method with the thermal decomposition of trifluoroacetate as precursors and organic solvent at a high boiling point. The UCNPs have an emission in the field of near infrared wavelength, cubic shape and nano-size in length. In this study, we will further investigate it for cancer therapy with NIR optical detection onto the solid substrate.

  • PDF

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.

Experimental Study on the Pressure Characteristics in the Cupping Therapy (부항요법(附缸療法)의 압력특성에 관한 실험적 연구)

  • Kim, Yang-Joong;Kim, Do-Ho;Yeom, Seung-Chul;Lim, Byung-Chuel;Choi, Youn-Sung;Lee, Geon-Hui;Kim, Hyung-Soo;Lee, Jai-Kyoo;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.121-130
    • /
    • 2008
  • Objectives : Cupping therapy is a stimulation therapy similar to acupuncture and moxibustion with effects that differ depending on the degree of stimulus. To make the strength of the skin objective in cupping therapy for this study, we measured negative pressure in the cupping jar and calculated the expansion rate of the skin. Subjects and Methods : In this study, we experimented with cupping therapy jars made for sale and used in clinics. We studied the pressure in the jars and the changes on the skin surface by measuring properties. We used commercial jars of four different volumes and diameters and tried to discover the properties on the size of the jar. Results : The results of experiment with the cupping therapy are as follows: 1. The lowest pressure in a jar was measured at $-600{\sim}610mmHg$, and the number of operating of vacuum pump for reaching lowest pressure was increased recording where the volume of the jar would be big, but the lowest pressure was not increased recording where the size of that would be big. 2. As the vacuum pump continued to operate, the pressure gradient in the jar got smaller which shows that the expansion rate of the skin was not linear. The pressure gradient shows different operational numbers on the vacuum pump near 0mmHg/operation unrelated to jar volume. 3. When negative pressure worked on the jar, air in the jar decreased. The percentage of air gradually reduced as the negative pressure acted in the jar. For example, the percentage of skin was 37-66% when the negative pressure, reatched -500mmHg. According to out results, different test areas generate different percentages of air in the jar, presumably related to skin elasticity. This phenomenon was most pronounced with the smallest jars. 4. At -500mmHg, the expansion rate of the skin was 1.57-1.9 on the abdomen, and $1.52{\sim}1.68$ on the back. The expansion rate of the skin appeared greater when the jar was relatively small, and it appeared smaller when the jar volume was relatively large relatively.

  • PDF