• Title/Summary/Keyword: Vacuum simulation

Search Result 533, Processing Time 0.024 seconds

Measurement of the ICRH antenna phasing using antenna strap probe based diagnostic system in EAST tokamak

  • Liu, L.N.;Liang, Q.C.;Yang, H.;Zhang, X.J.;Yuan, S.;Mao, Y.Z.;Zhang, W.;Zhu, G.H.;Wang, L.;Qin, C.M.;Zhao, Y.P.;Cheng, Y.;Zhang, K.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3614-3619
    • /
    • 2022
  • To operate the ion cyclotron resonance heating (ICRH) antennas in a better heating state and produce relatively low impurities, it is necessary to control the antenna spectrum by changing the antenna phasing. As the electrical length of the antenna feeding transmission lines is changing as a matter of the standing wave pattern at the ceramic supports, 90° elbows, T-connectors and antenna loops, we chose to measure the current at the grounding points of the antenna loops by antenna strap probe. The voltage drops along a small, several millimeter-long paths at the end of the antenna loops give a signal that is proportional to the current in the antenna loop. Through the simulation of the antenna strap probe and the actual measurement of the antenna phasing under vacuum conditions, the reliability of the antenna strap probe based diagnostic system have been successfully proved. Moreover, this system was successfully applied to the ICRH daily experiments in the spring of 2021. In the near future, the active real-time feedback control of the antenna phasing system will be developed based on this diagnostic system in the EAST tokamak.

Study of oxidation behavior and tensile properties of candidate superalloys in the air ingress simulation scenario

  • Bin Du;Haoxiang Li;Wei Zheng;Xuedong He;Tao Ma;Huaqiang Yin
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.71-79
    • /
    • 2023
  • Air ingress incidents are major safety accidents in very-high-temperature reactors (VHTRs). Air containing a high volume fraction of oxygen may cause severe oxidation of core components at the VHTR, especially for the significantly thin alloy tube wall in the intermediate heat exchanger (IHE). The research objects of this study are Inconel 617 and Incoloy 800H, two candidate alloys for IHE in VHTR. The air ingress accident scenario is simulated with high-temperature air flow at 950 ℃. A continuous oxide scale was formed on the surfaces of both the alloys after the experiment. Because the oxide scale of Inconel 617 has a loose structure, whereas that of Incoloy 800H is denser, Inconel 617 exhibited significantly more severe internal oxidation than Incoloy 800H. Further, Inconel 617 showed a significant decrease in ultimate tensile strength and plasticity after aging for 200 h, whereas Incoloy 800H maintained its tensile properties satisfactorily. Through control experiment under vacuum, we preliminarily concluded that serious internal oxidation is the primary reason for the decline in the tensile properties of Inconel 617.

몰드 두께에 의한 팬 아웃 웨이퍼 레벨 패키지의 Warpage 분석 (Analysis of Warpage of Fan-out Wafer Level Package According to Molding Process Thickness)

  • 문승준;김재경;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.124-130
    • /
    • 2023
  • Recently, fan out wafer level packaging, which enables high integration, miniaturization, and low cost, is being rapidly applied in the semiconductor industry. In particular, FOWLP is attracting attention in the mobile and Internet of Things fields, and is recognized as a core technology that will lead to technological advancements such as 5G, self-driving cars, and artificial intelligence in the future. However, as chip density and package size within the package increase, FOWLP warpage is emerging as a major problem. These problems have a direct impact on the reliability and electrical performance of semiconductor products, and in particular, cause defects such as vacuum leakage in the manufacturing process or lack of focus in the photolithography process, so technical demands for solving them are increasing. In this paper, warpage simulation according to the thickness of FOWLP material was performed using finite element analysis. The thickness range was based on the history of similar packages, and as a factor causing warpage, the curing temperature of the materials undergoing the curing process was applied and the difference in deformation due to the difference in thermal expansion coefficient between materials was used. At this time, the stacking order was reflected to reproduce warpage behavior similar to reality. After performing finite element analysis, the influence of each variable on causing warpage was defined, and based on this, it was confirmed that warpage was controlled as intended through design modifications.

  • PDF

전신 정위 고정장치 제작과 임상효과에 대한 연구 (The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.30-38
    • /
    • 2004
  • 목적: 방사선 치료 시 환자의 움직임을 최대한 고정시켜 줄 수 있으며 환자 자세에 대한 Setup 오차를 감소시키고 환자 전신에 산재한 병소를 위치화하고 좌표화할 수 있는 전신 정위 고정장치 제작과 제작한 고정장치에 대한 고정효과 및 재현성을 나타내는 환자 자세의 Setup 오차를 평가하였다. 대상 및 방법: 자체 제작한 고정장치는 크게 기본판(base plate)과 고정틀(Immobilizer), Vacuum cushion, 벨트로 이루어진다. 기본판은 50${\times}$130${\times}$1 ㎤ 베크라이트로 고정틀은 견고한 아세탈 재질을 사용하여 제작하였다. 초기의 Lax frame의 경우, side panel에 부착되어 있는 좌표계(coordinates)를 기본판 바닥에 radiopaque catheter wire를 사용하여 N 타입으로 새겨서 넣어 위치측정이 가능한 좌표계로 적용할 수 있도록 하였다. 제작된 고정장치에 대한 성능실험으로 방사선 투과율 측정 실험과 가상표적을 부착한 지원 환자를 대상으로 표적에 대한 위치측정실험이 수행되었다. 그리고 CCTV 카메라와 Digital Video Recorder (DVR)를 이용하여 획득된 환자 영상을 Matlab 프로그램으로 환자 자세에 대한 Setup 오차를 분석하였다. 결과: 전신 정위 고정장치는 CT 촬영과 방사선치료 시 사용 가능성에 중점을 두고 제작되었다. 이 고정장치의 구조는 갠트리의 회전각의 변화에 따라 충돌하지 않게 제작되었고 측면으로 경사지게 입사되는 빔의 투과율을 최대화할 수 있게 제작되었다. 고정틀의 고정효과를 높여주는 고정벨트는 입사된 빔의 방향에 방해되지 않게 제작되었다. 고정장치에 대한 방사선 투과율은 10과 21 MV의 에너지에서 95, 95%로 측정되었고 지원 환자에 부착한 가상 표적의 위치는 CT 촬영으로 파악할 수 있었다. Matlab 프로그램으로 분석한 setup 오차는 흉부의 측면과 중심부위에서 3.69$\pm$1.60, 2.14$\pm$0.78 mm이고 복부의 측면과 중심부위에서 7.11$\pm$2.10, 6.54$\pm$2.22 mm이며 여자 환자 경우, 가슴 측면의 Setup 오차는 6.33$\pm$1.55 mm으로 측정되었다. 결론: 전신 정위 고정장치의 제작과 실험을 통해 extra-cranial 암에 대한 방사선수술에서 매우 실용적이고 유용하게 사용될 것으로 사료되며 표적 위치 결정과 환자 고정 도구로서 사용될 것이다. 더 많은 환자 치료자세의 Setup 오차 측정이 수행되면 정확한 환자의 Setup 오차의 결과를 향상시킬 수 있을 것으로 기대된다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가 (Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제11권1호
    • /
    • pp.135-147
    • /
    • 2015
  • 최근 지하공동구(Underground Common Utility Tunnels)는 도시민이 일상생활을 영위하는데 필요한 전기, 통신, 상수도, 도시 가스, 하수도뿐만 아니라 냉난방시설, 진공 집진관, 정보처리케이블 등의 시설물을 2종 이상 공동으로 수용하기 위한 지하시설물로서 국가의 중추기능을 담당하는 시설이지만, 화재 사고시 신속한 대처가 힘들고 각종 케이블 연소시 발생하는 유독가스 및 연기에 의해 공동구 내에 진입하여 진압하기가 힘들다. 따라서 화재발생시 막대한 재산피해 및 통신두절 등 국가의 중추신경이 마비됨은 물론 시민불편사항을 초래하게 된다. 따라서 본 논문은 지금까지 발생 되어온 국내,외 공동구 화재사례에서 화재발생의 주요원인으로 전기공사로 인한 합선 및 가연성케이블에 의한 열화접촉으로 화재가 발생하는 것이 대다수를 차지하고 있음에 착안하여 실제 공동구 모형을 제작하고 화재를 재현함으로서 과학적으로 화재의 성상을 분석하는데 그 목적이 있다. 화재실험은 지하공동구 내에 정온식 감지선형 감지기(Line type fixed temperature detector), 방화문(Fire door), 연결살수설비(Connection deluge set), 및 환기설비를 설치하고, 송 배전케이블은 일정구간 내화(Fireproof)도료로 도장하며, 난방관은 내화 피복된 상태에서 실험하였다. 그 결과 Type II의 경우 최고온도가 $932^{\circ}C$로 측정되었고, 일정한 온도에서 정온식감지선형감지기가 화재위치를 정확하게 수신반에 표시되었다. 그리고 Type III의 경우인 송 배전케이블은 일정구간 내화도료로 도장한 것은 내화성능이 없는 것으로 나타났고, 내화피복(Fireproof covered)된 난방관은 약 30분 정도의 내화성능이 있는 것으로 나타났다. 또한 화재뮬레이션 결과는 실물화재시험시의 화재하중(Fire load)을 입력하여 실시한 결과로서 최고온도가 $943^{\circ}C$로 실물화재실험시의 $932^{\circ}C$와 거의 일치 하였다. 따라서 공동구 화재하중만으로 화재시뮬레이션을 실시하여 화재성상에 대한 예측이 가능한 것으로 판단되며 시뮬레이션으로 얻은 열방출률(Heat release rate), 연기층의 높이, 산소(O2), 일산화탄소(CO), 이산화탄소(CO2)의 농도 등의 결과 값들은 실제 화재실험시의 값으로 적용시킬 수 있는 것으로 판단된다. 향후 본 연구에서 구축한 국내 지하공동구 화재사고에 대한 실험자료 및 매년 지속적으로 화재사례들을 분석하여 축적하고 법 규정 및 관리 메뉴얼 등을 보완함으로써 국내 지하공동구 화재사고에 대한 보다 신뢰성 있는 정보를 제공해 줄 수 있을 것이며, 효과적이고 체계적으로 지하공동구의 신설 및 유지 관리 보수에 기여할 것으로 기대된다.

정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과 (Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame)

  • 안승도;이병용;최은경;김종훈;노영주;신경환;김경주;정원균;장혜숙
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.251-256
    • /
    • 2000
  • 목적 : 1990년대 이후 개발된 정위 체부 고정틀을 이용한 체부 정위방사선수술의 치료효과, 치료의 정확성과 후유증에 대해 후향적으로 알아보고자 하였다. 대상 및 방법 : 1997년 12월부터 1999년 6월까지 간암 3명, 동정맥기형 1명, 폐전이 6명와 간전이 1명 등 모두 11명에서 정위 체부 고정틀을 이용하여 체부 방사선수술을 시행했다. 환자의 고정은 정위 체부 고정틀에 vacuum pillow를 이용하여 수행하였고 chest marker와 leg marker를 이용하여 흉골부위 또는 등부위와 경골부위의 피부에 환자 위치 표시를 하였다. 이후 모의치료실로 이동하여 X선 투시기를 통해 횡경막의 움직임을 측정한 후 Diaphragm control을 사용하여 1 cm 이하로 횡경막의 움직임을 최소화하였다. CT-simulator를 이용하여 치료부위의 단층촬영을 시행한 후 치료계획을 세웠다. 매회 치료전 CT-simulator를 이용하여 단층촬영을 반복하여 최초의 단층촬영의 영상과 수동적으로 비교하여 치료의 정확성을 확인하고 오차가 5 mm 이내인 경우 치료를 시행하였다. 방사선 치료는 90$\%$ 등선량곡선에 10 Gy씩 1일 내지 2일 간격으로 3회 시행하여 총30 Gy를 조사하였다. 결과 : 중앙 추적관찰기간은 12개월이었다. 11명의 환자 중 1명(9$\%$)의 환자에서 국소적 완전관해를 보였고 4명(36$\%$)에서 부분관해를 보였다. 계획용표적체적은 3$\~$111 cc 였고 평균값은 18.4 cc 였다. 치료 오차를 측정한 결과 X, Y, Z 축으로 오차범위는 모두 5 mm 이내를 보였다. 치료 중 또는 치료 직후에 올 수 있는 고열, 통증 등의 급성후유증은 관찰되지 않았다. 결론 : 정위 체부 고정틀을 이용한 체부 방사선수술은 뛰어난 치료의 재현성을 보여주었고 간 혹은 펴종양에서 유용한 치료 방법으로 이용될 수 있을 것으로 기대된다.

  • PDF

쇄골 상부 림프절을 포함하는 왼쪽 유방암의 VMAT 치료계획시 X-Jaw split을 이용한 선량비교에 관한 연구 (Study on dose comparison using X-Jaw split in VMAT treatment planning for left breast cancer including supraclavicular lymph nodes.)

  • 김학준;이양훈;민제순
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.137-144
    • /
    • 2021
  • 목 적 : VMAT을 이용한 쇄골 상부 림프절을 포함하는 왼쪽 유방암 치료 시 X-Jaw를 나눈 치료계획과 기존 Full field VMAT 치료계획과의 선량분포를 비교 분석하여 X-Jaw split VMAT의 유용성을 평가하였다. 대상 및 방법 : 쇄골 상부 림프절을 포함하는 왼쪽 유방암 환자 10명을 대상으로 Vacuum cushion을 이용하여 CT simulation 하고 2 Arc Full field VMAT과 4 Arc X-Jaw split VMAT을 각각 치료계획 하였다. 각 치료계획은 처방 선량(Prescription dose)이 치료계획표적용적(Planning Target Volume, PTV)의 95% 이상 포함이 되고 주변 정상장기(Organ at risk, OAR)에 최소한으로 조사되도록 설계하였다. 이후 선량체적용적(Dose volume histogram, DVH)을 통해 PTV과 OAR의 대한 선량분석을 하였다. 결 과 : 10명의 환자의 Full field VMAT치료계획과 X-Jaw split VMAT치료계획의 데이터를 평균값으로 나타내어 비교하였다. 처방선량지수(conformity index, CI) 1.05±0.04, 1.04±0.03, 선량균질지수(homogeneity index, HI) 1.07±0.008, 1.07±0.009 로 두 치료계획 간 차이는 크지 않았다. OAR의 경우 왼쪽 폐의 V5 56.1±6.50%, 50.4±6.30%, V20 20.0±4.15%, 13.52±3.61% 로 Full field VMAT대비 X-Jaw split VMAT에서 V5이 10.0% V20은 32.6% 감소하였다. 심장의 V30은 3.68±1.85%, 2.23±1.52%, 평균 선량은 8.93±1.65 Gy, 7.67±1.52 Gy로 X-Jaw split VMAT에서 V30은 39.3%, 선량은 14.1% 감소하였다. 정상조직인 왼쪽 폐와 심장은 통계적 유의 수치인 p-value 0.05미만으로 나타났다. 결 론 : PTV의 체적이 크고 X Jaw의 길이가 15 cm 이상이 되는 쇄골 상부 림프절을 포함하는 왼쪽 유방암치료의 경우 X-Jaw split VMAT 치료계획은 기존의 치료계획과 동등한 HI와 CI로 유사한 PTV coverage를 유지 하면서 개선된 선량분포를 나타내 OAR인 폐와 심장 등의 방사선량을 줄일 수 있어 부작용을 줄이는데 효과적이라고 생각된다.

Comparison of In vivo and In vitro Techniques for Methane Production from Ruminant Diets

  • Bhatta, Raghavendra;Tajima, K.;Takusari, N.;Higuchi, K.;Enishi, O.;Kurihara, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권7호
    • /
    • pp.1049-1056
    • /
    • 2007
  • This study was conducted to compare the methane ($CH_4$) production estimated by in vivo (sulfur hexafluoride tracer technique ($SF_6$)) with that of two in vitro rumen simulation (RUSITEC) and gas production (IVGPT)) techniques. Four adult dry Holstein cows, aged $7.4{\pm}3.0$ years and weighing $697{\pm}70$ kg, were used for measuring methane production from five diets by the $SF_6$ technique. The experimental diets were alfalfa hay ($D_1$), corn silage + soybean meal (SBM) (910: 90, $D_2$), Italian rye grass hay +SBM (920: 80, $D_3$), rice straw +SBM (910: 90, $D_4$) and Sudan grass hay +SBM (920: 80, $D_5$). Each diet was individually fed to all 4 cows and 5 feeding studies of 17 d each were conducted to measure the methane production. In the RUSITEC, methane production was measured from triplicate vessels for each diet .In vitro gas production was measured for each of the diets in triplicate syringes. The gas produced after 24 and 48 h was recorded and gas samples were collected in vacuum vials and the methane production was calculated after correction for standard temperature and pressure (STP). Compared to the $SF_6$ technique, estimates of methane production using the RUSITEC were lower for all diets. Methane production estimated from 24 h in vitro gas production was higher (p<0.001) on $D_1$ as compared to that measured by $SF_6$, whereas on $D_2$ to $D_5$ it was lower. Compared to $SF_6$, methane production estimated from 48 h in vitro gas production was higher on all diets. However, methane estimated from the mean of the two measurement intervals (24+48 h/2) in IVGPT was very close to that of $SF_6$ (correlation 0.98), except on $D_1$. The results of our study confirmed that IVGPT is reflective of in vivo conditions, so that it could be used to generate a database on methane production potential of various ruminant diets and to examine strategies to modify methane emissions by ruminants.

캡슐트레인 주행 동특성 분석을 위한 축소 시험장치의 개발 (Development of the Small Scale Testbed for Running Dynamic Characteristics Analysis of the Capsule Train)

  • 이진호;유원희;이관섭
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.643-651
    • /
    • 2020
  • 공기 저항이 적은 아진공 상태의 튜브 안을 주행함으로써 초고속주행이 가능한 캡슐트레인은 부상 공극이 커서 인프라 건설 비용 절감에 유리한 초전도 유도 반발식 부상을 채택하고 있다. 초전도 유도 반발식 부상은 부상 공극을 크게 할 수 있고, 별도의 공극 제어가 필요 없는 장점이 있는 반면, 공극 변동량이 크고 부상력에 댐핑 특성이 작기 때문에 차량의 주행 안정성 및 승차감이 악화 될 수 있다. 이러한 단점을 극복하기 위해서는 차량의 주행 동특성에 기반한 주행안정화장치를 설계하고 적용하여야 한다. 본 연구에서는 캡슐트레인의 동특성을 모사하고 주행안정화장치의 성능을 사전에 검토할 수 있는 1/10 스케일의 축소형 시험장치를 개발하였다. 시험장치는 대차의 모션을 구현할 수 있는 6 자유도 스튜어트 플랫폼, 주행안정화장치가 적용된 2차 현가장치 및 차체로 구성되어 있다. Jaschinski가 제안한 동특성 상사 법칙에 따라 축소 시험장치를 제작하였고, 가이드웨이 불규칙도와 부상 강성이 반영된 대차 모션 구현 알고리즘을 적용하였다. 제작된 시험장치를 이용한 실험을 통해 얻어진 결과와 수치해석 결과와의 비교를 통해 시험장치의 성능을 검토하였다.