• Title/Summary/Keyword: Vacuum maintaining

Search Result 73, Processing Time 0.029 seconds

Developed Vacuum Film Packaging Method Maintains Quality of Enoki Mushrooms (Flammulina velutipes) during Simulated Vessel Export to Vietnam (팽이버섯의 베트남 모의수출 중 진공포장방법 개선을 통한 품질 유지 효과)

  • Choi, Ji Weon;Lim, Sooyeon;Lee, Ji Hyun;Eum, Hyang Lan;Lee, Jung-Soo;Park, Hye Sung;Im, Ji-Hoon;Do, Kyung Ran
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.133-142
    • /
    • 2022
  • Korean enoki mushrooms are exported to Southeast Asia and the United States, where there are complaints due to quality deterioration during the distribution process. In this study, we evaluated the efficacy of vacuum film packaging on quality maintenance in Korean enoki mushrooms during simulated vessel export to Vietnam using selected film, which was developed with vacuum packaging machine and oxygen absorber. We selected two MA film, one was 2-layerd 30 ㎛ CPP film (control) and the other was 3-layered 30 ㎛ CPP film (treatment) which is optimized film of higher gas and moisture permeability. The Korean enoki mushrooms were packaged with these two films using PAC-2000 or PAC-3000 vacuum packaging machine which was improved vacuuming of higher speed. Packed mushrooms were stored at 1℃ for 2 weeks and distributed at 20℃ for 2 days or 8℃ for 6 days. The efficiency of the film packaging was analyzed by vacuum maintaining index, and overall the quality characteristics such as off odor, color, cap cleavage, stem elongations and sensory evaluation were evaluated during storage and distribution. Results suggest that postharvest loss of fresh enoki mushroom could be reduced by packaging mushroom with 3-layered 30 ㎛ CPP films packaged using PAC-3000 machine during simulated vessel export to Vietnam due to vacuum maintaining. Oxygen absorber promoted off-odor at 20℃ distribution temperature, and did not affect storability at 1℃ storage compared to treated group without oxygen absorber treatment.

Development of Connector Sealing Method for Maintaining of Vacuum in the Momentum Wheel (모멘텀 휠의 내부 진공 유지를 위한 커넥터 밀봉방법 개발)

  • Cheon, Dong-Ik;Gong, Sung-Chul;Oh, Hwa-Suk;Lee, Seung-Wu
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.25-30
    • /
    • 2008
  • In general, we utilize momentum wheel to control spacecraft. It needs vacuum test to analyze the effect of space environments. The conventional vacuum connector which is composed of steel has problems for test with built in momentum wheel because of weight, thermal expansion, etc. We suggest possibility to manufacture the vacuum connector using aluminum mount, epoxy and industrial D-Sub considering cost, weight. We verify the performance through vacuum test.

  • PDF

The Pillar Design Variable Determination up of the Vacuum Glazing Panel using FEM (FEM을 이용한 진공유리 패널의 지지대 설계변수 설정)

  • Kim, Jae-Kyung;Jeon, Euy-Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.101-106
    • /
    • 2011
  • There are various methods in the flat panel display manufacture. The cost reduction effect is very big in case of using the screen printing method. The screen printing method is much used in the process of forming PDP barrier and can apply to the process of arranging the pillars for maintaining the vacuum gap of the vacuum glazing panel. The pillar which is one of the core elements for comprising vacuum glazing maintains the vacuum gap overcoming the vacuum pressure difference with the atmospheric pressure generated in vacuum glazing. At the same time, the deformation phenomenon by vacuum pressure is relived. In this paper, by using FEM about three considered in the pillar design and arrangement kinds of limiting factors, the simulation was performed. The pillar optimum arrangement method at within the maximum allowable tensile stress and heat transfer coefficients according to the arrangement try to be presented based upon the analyzed result data review and this validity tries to be verified by FEM.

Evaluation of the required cooling capacity of the Cryocooler in the vacuum system (극저온냉동기 직냉형 진공시스템의 냉동부하 평가)

  • 홍용주;박성제;김효봉;최영돈
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.171-173
    • /
    • 2003
  • The cryostat or dewar have been widely used for making and maintaining cryogenic and vacuum environments. The thermal performances of such cryogenic vacuum system mainly depend on the radiation heat transfer between hot and cold surface The characteristics of radiation heat transfer are complicated, because amounts of heat transfer depend on view factor, emissivities, and areas of thermal elements. In this study, the analysis of the radiation heat transfer in the small cryogenic vacuum system was performed using the surface to surface radiation model for evaluation of the required cooling capacity of the cryocooler.

  • PDF

Experimental Study on Manufacturing of Insulation Vacuum Glazing and Measurement of the Thermal Conductance (단열 진공유리의 제작 및 열전달계수 측정에 관한 실험적 연구)

  • Lee Bo-Hwa;Yoon Il-Seob;Kwak Ho-Sang;Song Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.772-779
    • /
    • 2006
  • Window is a critical component in the design of energy-efficient buildings. To minimize the heat loss, insulation performance of the glazing has to be improved. Manufacturing of vacuum glazing has been motivated by the possibility of making windows of very good thermal insulation properties for such applications. It is made by maintaining vacuum in the gap between two glass panes. Pillars are placed between them to withstand the atmospheric pressure. Edge covers are applied to reduce conduction through the edge. Accurate measurements have been made of the radiative heat transfer, the pillar conduction and the gas conduction using a guarded hot plate apparatus. Vacuum glazing is found to have low thermal conductance roughly below $1W/m^2K$. Among the heat transfer modes of residual gas conduction, conduction through support pillar and the radiative heat transfer between the glass panes, the last one is the most dominant to the overall thermal conductance. Vacuum glazing using very low emittance AI-coated glass has an overall thermal conductance of about $0.7W/m^2K$.

A Development of the Precision Machine with Vacuum Chuck and a Study on the Characteristics of Oxygen Free Couper (진공척 미세 가공기 개발 및 무산소동 절삭 특성 연구)

  • Kim, Geon-Hee;Kim, Youn-Joong;Kook, Myung-Ho;Lee, Sun-Kyu;Hong, Kweon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.2
    • /
    • pp.28-33
    • /
    • 2007
  • This paper describes development of low cost precision machine that has a vacuum chuck. This study mainly aims to find out a cutting condition for maintaining optimum surface condition and to examine cutting characteristics of the precision machine that is equipped by diamond bites. The cutting materials is oxygen free copper. Several experiments were carried out to find out the main factors that affect the surface roughness such as principal axis RPM(rotation per minute), feeding speed, and cutting depth. As a result, we obtain The optimum cutting condition of the developed precision machine.

  • PDF

Effect of Evacuation Variables on Pressure Change in the Die Cavity (다이캐스팅 금형 공간 내의 감압도에 미치는 제 변수의 영향)

  • Kim, Ki-Young
    • Journal of Korea Foundry Society
    • /
    • v.20 no.3
    • /
    • pp.181-187
    • /
    • 2000
  • There are two types of vacuum die casting, one is known as the chill block method, and the other is the valve block method. Efficiency of the valve block method is better than the chill block method. However purchasing and maintaining cost of the former one is very high, the latter method is popular in many small and medium die casting shops. Simple evacuation system using chill vent was prepared to investigate the effect of the air pressure, hose length and chill vent type on the pressure change in die cavity in this study. The rate of evacuation was influenced by the evacuation method, chill vent condition and hose length. Evacuation time became longer and vacuum level lower when evacuating cavity via chill vent. It took a longer time to evacuate the cavity when a longer hose was used. Vacuum level in the cavity also decreased with increase in hose length.

  • PDF

Membrane Degassing Process of Sweep Gas-vacuum Combination Type for Ammonia Removal (스윕 가스-진공 혼합식 탈기막 시스템을 활용한 암모니아 제거)

  • Yoon, Hongsik;Min, Taijin;Lee, Gunhee;Kim, Hyoung-Tak;Shin, Wanho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.835-842
    • /
    • 2022
  • In this study, the membrane degassing process of the sweep gas - vacuum combination type was proposed for ammonia wastewater treatment. The effect of pH, initial ammonia concentration and scale-up on ammonia degassing performance was investigated. As a result, as the pH and the initial ammonia concentration increased, the degassing permeate flux was improved. On the other hand, the ammonia mass transfer coefficient increased as the initial ammonia reduced, which seems to be due to the driving force of the sweep gas-vacuum combination type membrane degassing system proposed in this study. In addition, 80 mg NH3/min of the ammonia degassing rate was achieved using a 6×28 inch size module. Better degassing performance is expected if consideration for maintaining vacuum pressure is involved in the scale-up design.

The New Storage Technology: Effect of Far Infrared Ray (FIR) Ceramic Sheet Package on Storage Quality of Pork Loin

  • Lin, Liang-Chuan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.11
    • /
    • pp.1695-1700
    • /
    • 2003
  • A total of 30 pork loin sections were utilized to evaluate the effects of FIR ceramic sheet in PE and vacuum package on preserving the quality of chilled pork stored at 4 and $0^{\circ}C$. Based on meat color, results indicated that pork loin packaged in ceramic sheet and control treatment showed that the samples of the control treatment tended to darken gradually in comparison with the samples at 0 day, but FIR treatment had few changes. Among the total plate counts of sliced loin in PE and loin in vacuum package under different storage times at 4 and $0^{\circ}C$, results showed that FIR ceramic sheet package treatment had lower total plate counts and significant differences (p<0.05). In VBN value, both treatments tended to rise high with the increasing of storage time, but the FIR treatment was significantly lower (p<0.05) than the control treatment. Its results had a corresponding relationship with the total plate counts. Regarding the drip loss of sliced loin in PE and loin in vacuum package, it showed that FIR ceramic sheet package treatment had lower drip loss and significant differences (p<0.01). These results showed that the use of FIR ceramic sheet package, including PE and vacuum package, is an effective method of maintaining the quality of meat.