• Title/Summary/Keyword: Vacuum exhaust

Search Result 96, Processing Time 0.026 seconds

Tritium Fuel Cycle of the International Thermonuclear Experimental Reactor (국제핵융합실험로 삼중수소 연료주기)

  • Song, Kyu-Min;Sohn, Soon Hwan;Chung, Hongsuk;Yun, Sei-Hun;Jung, Ki Jung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • International Thermonuclear Experimental Reactor (ITER) will be constructed in 2019 according to the JIA (Joint Implementation Agreement) of 7 countries. The ITER fusion fuel cycle consists of fusion vacuum vessel, tritium plant and fuelling system. The tritium plant provides the functions of storage, delivery, separation, removal and recovery of the deuterium and tritium used as fusion fuels for the ITER. The tritium plant systems supply deuterium and tritium from external sources and treat all tritiated fluids from ITER operation through Storage and Delivery System (SDS), Tokamak Exhaust Processing (TEP), Isotope Separation System (ISS), Water Detritiation System & Atmosphere Detritiation System (WDS & ADS) and Analysis System (ANS). In this paper, the functions and design requirements of the major systems in the tritium plant and the status of R&D are described. Korean party is developing the SDS for ITER tritium plant and partially attaining the WDS technology through the construction and operation experience of the Wolsong Tritium Removal Facility (WTRF). Now it is expected that researchers in other fields such as chemical engineering take part in the development of upcoming technologies for ISS and TEP.

Development of Slurry Flow Control and Slot Die Optimization Process for Manufacturing Improved Electrodes in Production of Lithium-ion Battery for Electric Vehicles (전기자동차 리튬이온 배터리 제조공정에서 Loading Level 산포최소화 코팅을 통한 전극 품질개선에 관한 연구)

  • Jang, Chan-Hee;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • Electric vehicles are environmentally friendly because they emit no exhaust gas, unlike gasoline automobiles. However, since they are driven by the electric power from batteries, the distance they can travel based on a single charge depends on their energy density. Therefore, the lithium-ion battery having a high energy density is a good candidate for the batteries of electric vehicles. Since the electrode is an essential component that governs their efficiency, the electrode manufacturing process plays a vital role in the entire production process of lithium-ion batteries. In particular, the coating process is a critical step in the manufacturing of the electrode, which has a significant influence on its performance. In this paper, we propose an innovative process for improving the efficiency and productivity of the coating process in electrode manufacturing and describe the equipment design method and development results. Specifically, we propose a design procedure and development method in order to improve the core plate coating quality by 25%, using a technology capable of reducing the assembly margin due to its high output/high capacity and improving the product capacity quality and assembly process yield. Using this method, the battery life of the lithium-ion battery cell was improved. Compared with the existing coating process, the target loading level is maintained and dispersed to maintain the anode capacity (${\pm}0.4{\rightarrow}{\pm}0.3mg/cm^2r$ reduction).

Improved Drying Process for Electrodes in Production of Lithium-Ion Batteries for Electric Vehicles (전기자동차용 리튬이온 전지의 제조공정을 위해 개선된 극판 건조 기술)

  • Jang, Chan-Hee;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.37-45
    • /
    • 2018
  • An electric vehicle is an environmentally friendly vehicle because there is no exhaust gas, unlike gasoline automobiles. On the other hand, because the electric vehicle is driven by electric power charged in batteries, the distance to go through a single charge depends on the energy density of the batteries. Therefore, a lithium-ion battery with a high energy density is a good candidate for batteries in electric vehicles. Because the electrode is an essential component that governs the efficiency of a lithium-ion battery, the electrode manufacturing process plays a vital role in the entire production process of lithium-ion batteries. In particular, the drying process during the electrode manufacturing process is a critical process that has a significant influence on the performance. This paper proposes an innovative process for improving the efficiency and productivity of the drying process in electrode manufacturing and describe the equipment design method and development results. In particular, the design procedure and development method for enhancing the electrode adhesion power, atmospheric pressure superheated steam drying technology, and drying furnace slimming technologies are presented. As a result, high-speed drying technology was developed for battery electrodes through the world's first turbo dryer technology for mass production using open/integrated atmospheric pressure superheated steam. Compared to the conventional drying process, the drying furnace improved the productivity (Dry Lead Time $0.7min{\rightarrow}0.5min$).

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Cohort Observation of Blood Lead Concentration of Storage Battery Workers (축전지공장 근로자들의 혈중 연농도에 대한 코호트 관찰)

  • Kim, Chang-Yoon;Kim, Jung-Man;Han, Gu-Wung;Park, Jung-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.324-337
    • /
    • 1990
  • To assess the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, 156 workers (116 exposed subjects and 40 controls) of a newly established battery factory were examined for their blood lead concentration (Pb-B) in every 3 months up to 18 months. Air lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean Pb-B of the controls was $21.97{\pm}3.36{\mu}g/dl$ at the preemployment examination and slightly increased to $22.75{\pm}3.38{\mu}g/dl$ after 6 months. Mean Pb-B of the workers who were employed before the factory was in operation (Group A) was $20.49{\pm}3.84{\mu}g/dl$ on employment and it was increased to $23.90{\pm}5.30{\mu}g/dl$ after 3 months (p<0.01). Pb-B was increased to $28.84{\pm}5.76{\mu}g/dl$ 6 months after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $26.83{\mu}g/dl\;and\;28.28{\mu}g/dl$ in the subsequent 4 tests. Mean Pb-B of the workers who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $16.58{\pm}4/53{\mu}g/dl$ before the exposure and it was increased to $28.82{\pm}5.66{\mu}g/dl$(P<0.01) in 3 months later (1 month after the intervention). The values of subsequent 4 tests remained between 26.46 and $28.54{\mu}g/dl$. Mean Pb-B of the workers who were employed after intervention program had been started (Group C) was $19.45{\pm}3.44{\mu}g/dl$ at the preemployment examination and gradually increased to $22.70{\pm}4.55{\mu}g/dl$ after 3 months(P<0.01), $23.68{\pm}4.18{\mu}g/dl$ after 6 months, and $24.42{\pm}3.60{\mu}g/dl$ after 9 months. Work stations were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3\;and\;0.208mg/m^3$ in follow-up tests. The Pb-A of part II was decreased from $0.232mg/m^3\;to\;0.148mg/m^3,\;and\;0.120mg/m^3$ after the intervention. Pb-A of part III and W was tested only after intervention and the Pb-A of part III were $0.124mg/m^3$ in Jannuary 1988 and $0.081mg/m^3$ in August 1988. The Pb-A of part IV not stationed at one place but moving around, was $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-B and Pb-A. Pb-B of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. Pb-B of the workers in the part of the lowest Pb-A incerased more rapidly. Pb-B of group C workers was the highest in part I and the lowest in part IV. These findings suggest that Pb-B is more valid method than Pb-A for monitoring the health of lead workers and intervention in personal hygiene is more effective than environmental intervention.

  • PDF

A cohort study on blood zinc protoporphyrin concentration of workers in storage battery factory (축전지 공장 근로자들의 혈중 Zinc Protoporphyrin에 대한 코호트 연구)

  • Jeon, Man-Joong;Lee, Joong-Jeong;SaKong, Joon;Kim, Chang-Yoon;Kim, Jung-Man;Chung, Jong-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.112-126
    • /
    • 1998
  • To investigate the effectiveness of the interventions in working environment and personal hygiene for the occupational exposure to the lead, the blood zinc protoporphyrin (ZPP) concentrations of 131 workers (100 exposed subjects and 31 controls) of a newly established battery factory were analyzed. They were measured in every 3 months up to 18 months. Ai. lead concentration (Pb-A) of the workplaces was also checked for 3 times in 6 months interval from August 1987. Environmental intervention included the local exhaust ventilation and vacuum cleaning of the floor. Intervention of the personal hygiene included the daily change of clothes, compulsory shower after work and hand washing before meal, prohibition of cigarette smoking and food consumption at the work site and wearing mask. Mean blood ZPP concentration of the controls was $16.45{\pm}4.83{\mu}g/d\ell$ at the preemployment examination and slightly increased to $17.77{\pm}5.59{\mu}g/d\ell$ after 6 months. Mean blood ZPP concentration of the exposed subjects who were employed before the factory was in operation (Group A) was $17.36{\pm}5.20{\mu}g/d\ell$ on employment and it was increased to $23.00{\pm}13.06{\mu}g/d\ell$ after 3 months. The blood ZPP concentration was increased to $27.25{\pm}6.40{\mu}g/d\ell$ on 6 months (p<0.01) after the employment which was 1 month after the initiation of intervention program. It did not increase thereafter and ranged between $25.48{\mu}g/d\ell$ and $26.61{\mu}g/d\ell$ in the subsequent 4 results. Mean blood ZPP concentration of the exposed subjects who were employed after the factory had been in operation but before the intervention program was initiated (Group B) was $14.34{\pm}6.10{\mu}g/d\ell$ on employment and it was increased to $28.97{\pm}7.14{\mu}g/d\ell$ (p<0.01) in 3 months later(1 month after the intervention). The values of subsequent 4 tests were maintained between $26.96{\mu}g/d\ell$and $27.96{\mu}g/d\ell$. Mean blood ZPP concentration of the exposed subjects who were employed after intervention program had been started (Group C) was$21.34{\pm}5.25{\mu}g/d\ell$ on employment and it was gradually increased to $23.37{\pm}3.86{\mu}g/d\ell$ (p<0.01) after 3 months, $23.93{\pm}3.64{\mu}g/d\ell$ after 6 months, $25.50{\pm}3.01{\mu}g/d\ell$ after 9 months, and $25.50{\pm}3.10{\mu}g/d\ell$ after 12 months. Workplaces were classified into 4 parts according to Pb-A. The Pb-A of part I, the highest areas, were $0.365mg/m^3$, and after the intervention the levels were decreased to $0.216mg/m^3$ and$0.208mg/m^3$ in follow-up test. The Pb-A of part II which was resulted in lowe. value than part I was decreased from $0.232mg/m^3$ to $0.148mg/m^3$, and $0.120mg/m^3$ after the intervention. The Pb-A of part III was tested after the intervention and resulted in $0.124mg/m^3$ in January 1988 and $0.181mg/m^3$ in August 1988. The Pb-A of part IV was also tested after the intervention and resulted in $0.110mg/m^3$ in August 1988. There was no consistent relationship between Pb-A and blood ZPP concentration. The blood ZPP concentration of the group A and B workers in the part of the highest Pb-A were lower than those of the workers in the parts of lower Pb-A. The blood ZPP concentration of the workers in the part of the lowest Pb-A increased more rapidly. The blood ZPP concentration of the group C workers was the highest in part III. These findings suggest that the intervention in personal hygiene is more effective than environmental intervention, and it should be carried out from the first day of employment and to both the exposed subjects, blue color workers and the controls, white color workers.

  • PDF