• Title/Summary/Keyword: Vacuum discharge tube

Search Result 36, Processing Time 0.023 seconds

Exact Solutions of Plasma Diffusion in a Fine Tube Positive Column Discharge (세관 양광주 방전에서 플라즈마 확산의 완전 해)

  • Jin, D.J.;Jeong, J.M.;Kim, J.H.;Hwang, H.C.;Chung, J.Y.;Cho, Y.H.;Lim, H.K.;Koo, J.H.;Choi, E.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • The ambipolar diffusion equation has been solved in a fine-tube lamp of a few mm in diameter. In the diffusion of radial direction, the plasma diffuses and vanishes away at the glass wall by recombination with the characteristic time of plasma loss is given by $\tau_r\;=\;(r_0/2.4)^2/D_a$. With the radius $r_0{\sim}1\;mm$ and the ambipolar diffusion coefficient $D_a{\sim}0.01\;m^2/s$, the vanishing time is calculated $\tau_r{\sim}10\;{\mu}s$ which corresponds to the least value of frequency 30 kHz for the sustaining the plasma in the operation of high voltage AC-power. In the diffusion of longitudinal z-direction, a high density plasma generated at the area of a high voltage electrode, diffuses into the positive column with the characteristic time $\tau_z{\sim}0.1\;s$. The plasma diffusion velocity at the boundary of high density plasma is $u_D{\sim}10^2\;m/s$ at the time $t{\sim}10^{-6}$ s and the diffusion velocity becomes slow as $u_D{\sim}1\;m/s$ at $t{\sim}10^{-3}\;s$. Therefore, for the long lamp of 1 m, it takes about several seconds for the high density plasma at the area of electrode to diffuse through the whole positive column space.

Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel (극저온액체 저장용기에서 열전도 차폐단의 영향)

  • Kim, S.Y.;Kang, B.H.;Choi, H.J.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 1998
  • An experimental study on effect of vapor-cooled heat stations in a 5.5 liter cryogenic vessel has been performed. The cryogenic vessel is made of stainless steel of thickness of 1mm and insulated by the combined insulation of vacuum, MLI(multi-layer insulation) and vapor-cooled radiation shield. Vapor-cooled heat stations are also constructed based on the 1-dimensional thermal analysis to reduce the heat inleak through a filling tube. Thermal analysis indicates that the vapor-cooled heat stations can substantially enhance the performance of vessel for cryogenic fluids with high $C_p/h_{fg}$ where $C_p$ the specific heat and $h_{fg}$ the heat of vaporization, such as $LH_2$ and LHe. The experimental results for $LN_2$ shows that the total heat inleak into inner vessel consists of 14% radiation and 86% conduction through the filling tube. Therefore, it is expected that the conduction heat in leak of the vessel for high $C_p/h_{fg}$ cryogenic fluids can be significantly reduced. powders. The amount of copper coating was 20wt%. In order to examine corrosion behavior of the electrodes, the corrosion current and the current density, in 6M KOH aqueous solution after removal of oxygen in the solution, were measured by potentiodynamic and cyclic voltamo methods. The results showed that Co in the alloy increased corrosion resistance of the electrode whereas Ni decreased the stability of the electrode during the charge-discharge cycles. The electrode used Si sealant as a binder showed a lower corrosion current density than the electrode used PTFE and the electrode used Cu-coated alloy powders showed the best corrosion resistance.

  • PDF

Vacuum Assisted Wound Closure Appliance and Continuous Irrigation on Infected Chronic Wound (감염된 만성창상에서 국소음압세척치료의 이용)

  • Jeong, Jin-Wook;Kim, Jun-Hyung;Jung, Yung-Jin;Park, Mu-Sik;Son, Dae-Gu;Han, Ki-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.227-232
    • /
    • 2010
  • Purpose: Continuous irrigation method is an important step in managing wound infection. V.A.C. devices have been used in intractable wounds for reducing discharge, improving local blood flow, and promoting healthy granulation tissue. We expect synergistic effects of reduced infection and more satisfactory, accelerated wound healing when using both methods simultaneously. This study evaluated continuous irrigation combined with V.A.C. appliance for treatment of infected chronic wounds. Methods: We reviewed data from 17 patients with infected intractable chronic wounds. V.A.C. device (Group A) was used in 9 patients, and V.A.C. with antibiotics irrigation (Group B) was used in 8 patients. We placed Mepitel$^{(R)}$ on the surface of wound and placed an irrigation and aspiration tube on each side. A sponge was placed on the Mepitel$^{(R)}$ and covered with film dressing. The wound was irrigated continuously with mixed antibiotics solution at the speed of 200 cc/hr and aspirated through the wall suction at the pressure of -125 mmHg. V.A.C. applied time, wound culture and wound size were compared between the two groups. Results: No complication were seen in two groups. Compared with Group A, in the Group B, V.A.C. applied time was shortened from 32.7 days to 25.6 days and showed efficacy in the reduction rate of wound size. No statistical differences were shown in bacterial reversion. Conclusion: V.A.C. appliance with continuous irrigation is an effective new method of managing infected chronic wounds and useful to reduce treatment duration and decrease wound size. Moreover it could be applied more widely to infected wound.

Light Emission and Plasma Property in the External Electrode Fluorescent Lamps (외부전극 형광램프의 발광 및 플라즈마 특성)

  • Ahn, S.;Lee, M.;Jeong, J.;Kim, J.;Yoo, D.;Koo, J.;Kang, J.;Hong, B.;Choi, E.;Cho, G.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.172-180
    • /
    • 2007
  • A new diagnostics of plasma electron temperature and plasma density is introduced with the observation of the light emission along the tube of external electrode fluorescent lamps. With two different methods operating an external electrode fluorescent lamp of outer diameter 4.0 mm and length 860 mm for the back-light source of 37-inch LCD-TVs, the lighting modes and the plasma properties are investigated. In the center balance operation, the light-emission propagates simultaneously from both sides of the high voltage electrodes to the center of the lamp, while in conventional operation the light-emission propagates from the one end of a high voltage to the other ground electrode. In the operation value of luminance $10,000{\sim}15,000cd/m^2$, the electron plasma thermal energy $(kT_e)$ is about $1.3{\sim}2.7eV$ with the electron density $(n_e)$ is about $(1.6{\sim}3.6){\times}10^{16}m^{-3}$.

Influence of Glass Dielectric Property on the External Electrode Fluorescent Lamps (유리관의 유전 특성이 외부전극 형광램프에 미치는 영향)

  • Shin, Myeong-Ju;Jeong, Jong-Mun;Kim, Jung-Hyun;Kim, Ga-Eul;Lee, Mi-Ran;Yoo, Dong-Gun;Koo, Je-Huan;Hong, Byoung-Hee;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.330-337
    • /
    • 2007
  • Influence of glass dielectric property (dielectric constant K, dielectric loss) on the external electrode fluorescent lamps of the dielectric barrier discharge has been investigated with 4-different glasses. Conventional borosilicate glass tubes with $K=5.6{\sim}5.9$ and tan ${\delta}=5.0{\times}10^{-3}{\sim}6.0{\times}10^{-3}$ and aluminosilicate glass tubes with high K=6.6 and low tan ${\delta}=1{\times}10^{-4}$ and soda-lime glass tribes with K=7.7 and tan ${\delta}=1.37{\times}10^{-2}$ have been compared. The high value of dielectric constant K makes the capacitance of external electrode fluorescent lamps intensity and enhances the discharge efficiency. The dielectric loss of tan ${\delta}$ shows the factor of power consumption in the external electrode to induce heats and to be weak in pinhole stability. The aluminosilicate glass tubes of high K and low tan ${\delta}$ have been enhanced by $14{\sim}18%$ in luminance and efficiency in comparison with the conventional borosilicate glass tubes and the aluminosilicate external electrode fluorescent lamps are strong against the pinhole formation. Soda-lime glass tubes with high K and high tan ${\delta}$ are a little favorable in luminance and efficiency and they are very weak in pinhole occurrence.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.