• Title/Summary/Keyword: Vacuum degree

Search Result 241, Processing Time 0.032 seconds

Evaluation of Setup Errors for Tomotherapy Using Differently Applied Vacuum Compression with the Bodyfix Immobilization System (토모테라피 치료 시 Bodyfix System에서 진공압박에 따른 환자 위치잡이오차(Setup errors)의 평가)

  • Jung, Jae-Hong;Cho, Kwang-Hwan;Lee, Jeong-Woo;Kim, Min-Joo;Lim, Kwang-Chae;Moon, Seong-Kwon;Kim, Yong-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • The aim of this study is to evaluate the patient's setup errors in TomoTherapy (Hi-Art II, TomoTherapy, USA) Bodyfix system (Medical Intelligence, Ele-kta, Schwabmuchen, Germany) pressure in the vacuum compression, depending on and were evaluated. Bodyfix immobilization system and vacuum pressure was compression applied to the patients who received Tomotherapy thoracic and abdominal area, 21 patients were selected and TomoTehpay treatment total 477 of MVCT images were obtained. The translational (medial-lateral: ML, anterior-posterior: AP, superior-inferior: SI directions) and rolling were recorded and analyzed statistically. Using Pearson's product-moment coefficient and One-way ANOVA, the degree of correlation depending on the different vacuum pressure levels were statistically analyzed for setup errors from five groups (p<0.05). The largest average and standard deviation of systematic errors were 6.00, 5.95 mm in the AP and SI directions, respectively. The largest average of random errors were 4.72 mm in the SI directions. The correlation coefficients were 0.485, 0.244, and 0.637 for the ML-Roll, AP-Vector, and SI-Vector, respectively. SI-Vector direction showed the best relationship. In the results of the different degree of vacuum pressure in five groups (Pressure range: 30~70 mbar), the setup errors between the ML, SI in both directions and Roll p=0.00 (p<0.05) were shown significant differences. The average errors of SI direction in the vacuum pressure of 40 mbar and 70 mbar group were 4.78 mm and -0.74 mm, respectively. In this study, the correlation between the vacuum pressure and the setup-errors were statistically analyzed. The fact that setup-errors in SI direction is dependent in vacuum pressure considerly setup-errors and movement of interal organs was identified. Finally, setup-errors, and it, based on the movement of internal organs in Bodyfix system we should apply more than 50 mbar vacuum pressure. Based on the results of this study, it is suggested that accuracy of the vacuum pressure and the quantitative analysis of movement of internal organs and the tumor should be studied.

Ultrasound-Aided Monolayer Assembly of Spherical Silica Nanobeads (초음파 방법을 이용한 실리카 나노비드의 단층 정렬에 관한 연구)

  • Yoon, Sang-Hee;Yoon, Seo Young;Lee, Jin Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.298-305
    • /
    • 2013
  • Uniform silica nanobeads were synthesized by St$\ddot{o}$ber method and assembled in the form of monolayer on glass substrate using sonication method. Before the assembly of silica nanobeads, glass substrates were treated with molecular linkers, such as CP-TMS and PEI, and nanobeads were dispersed in toluene. In attachment test, SO (sonication without stacking) method and SS (sonnication with stacking) method was used and sonication time was controled. After the experiment, microbalance was use to measure deviation between before and after the attachment experiment then calculate percent of coverage. Minutely observe with SEM (Scanning Electron Microscopy) then select the most close-packed and monolayer assembled cover glass and calculate DOC (Degree of Coverage). In SO method, DOC increased very sharply and reach over 140 percent point, also got lots of multi-layer region. On the other hand, in SS method DOC increased slower than SO method but more close-packed and monolayer assembled.

A Study on the Changes in the Alliinase Activity during the Vacuum Freeze Drying of Onions(Allium cepa L.) (양파의 진공 동결 건조 과정 중 Alliinase 활성 변화에 관한 연구)

  • Chae, Soo-Kyu;Yun, Mi-Suk
    • Culinary science and hospitality research
    • /
    • v.14 no.1
    • /
    • pp.144-151
    • /
    • 2008
  • This study investigated the changes in the contents of allicin and diallyl disulfide and in the alliinase activity during the vacuum freeze drying of onion samples treated as the whole, sliced and crushed forms. The contents of allicin and diallyl disulfide in raw onions were 26.40ppm and 2.78ppm respectively. The contents of allicin and diallyl disulfide of onion samples treated as the whole, sliced and crushed forms increased with the progress of vacuum freeze drying. The degree of increase was different in each onion sample form prepared by vacuum freeze drying(p<0.05). The specific activity of alliinase in raw onions was 7.536 units/mg protein. The activity in onion samples treated as the whole, sliced and crushed forms decreased with the progress of vacuum freeze drying. The activity in the whole onion prepared by the vacuum freeze drying for 8 hrs reduced to 5.516 units/mg protein with 73.2% remaining and to 3.304 units/mg protein with 43.8% remaining for 36 hrs. The activity in the sliced onion prepared by the vacuum freeze drying for 36 hrs reduced to 2.366 units/mg protein with 31.4% remaining and the activity in the crushed onion prepared by the vacuum freeze drying for 36 hrs reduced to 2.232 units/mg protein with 29.6% remaining. The alliinase in onion sample treated as the whole form showed the highest remaining activity during the vacuum freeze drying.

  • PDF

Study of Cure Behavior of the External and Internal of Composite Parts (경화공정에 따른 복합재 부품 외부와 내부의 경화 거동 차이에 대한 연구)

  • Hyun, Dong Keun;Lee, Dong Seung;Shin, Do Hoon;Kim, Ji Hoon
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.302-308
    • /
    • 2020
  • We measured the thermal conductivity of composite materials manufactured by the autoclave and vacuum bag only processes and predicted the cure behavior of the external and internal of composite parts with a cure kinetics model. The temperature difference between the external and internal depends on the processes because of the change of thermal conductivity. In the autoclave process, the temperature and cure behavior of the internal were similar to those of the external because of the high thermal conductivity. However, the temperature of the internal of the vacuum bag only process was different from that of the external. The difference can influence the part quality and evacuation of air. Compression tests were performed to find the mechanical property using 0° unidirectional specimens. The composite of the vacuum bag only process was found to have a lower compressive strength than that of the autoclave process.

Manufacturing Process Improvement of Electrode for PEMFC (공정 효율 향상을 위한 연료전지전극 개발)

  • PARK, SEOK JUNG;LEE, JAE SEUNG;LEE, KI SUB;ROH, BUM WOOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.547-553
    • /
    • 2015
  • For commercialization of fuel cell electric vehicles, one of the key objectives is to reduce cost of full stack assembly. Regarding Membrane Electrode Assembly, the major issue is to improve fuel cell activation process in the initial Hydrogen Oxidation Reaction and Oxygen Reduction Reaction. In this research, the VD (Vacuum Drying) process has been developed for improvement of activation process. The VD condition is developed by controlling the temperature and degree of vacuum to remove the remaining solvent of electrode. Consequently, the electrode applied to VD process showed the low characteristics such as 3.5% of remaining solvent content and the improved efficiency such as 15% of activation process speed.

Treatment of high-salinity wastewater after the resin regeneration using VMD

  • Gao, Junyu;Wang, Manxiang;Yun, Yanbin
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.53-62
    • /
    • 2018
  • In this study, vacuum membrane distillation (VMD) was used to treat high-salinity wastewater (concentration about 17%) discharged by chlor-alkali plant after resin regeneration. The feasibility of VMD for the treatment of real saline wastewater by using Polyvinylidene fluoride (PVDF) microporous plate membrane with a pore diameter of $0.2{\mu}m$ was investigated. The effects of critical operating parameters such as feed temperature, velocity, vacuum degree and concentration on the permeate water flux were analyzed. Numerical simulation was used to predict the flux and the obtained results were in good agreement with the experimental data. The results showed that an increase in the operating conditions could greatly promote the permeate water flux which in turn decreased with an increase in the concentration. When the concentration varied from 17 to 25%, the permeate water flux dropped marginally with time indicating that the concentration was not sensitive to the decrease in permeate water flux. The permeate water flux decreased sharply until zero due to the membrane fouling resistance as the concentration varied from 25 to 26%. However, the conductivity of the produced water was well maintained and the average value was measured to be $4.98{\mu}s/cm$. Furthermore, a salt rejection of more than 99.99% was achieved. Overall, the outcome of this investigation clearly indicates that VMD has the potential for treating high-salinity wastewater.

Evaluation of the Vacuum brazed stainless steel by Ni-based filler metals (Ni기 삽입금속에 의해 진공 브레이징된 stainless steel의 특성평가)

  • Chang, Se-Hun;Hong, Ji-Min;Jeong, Chang-Yeol;Choi, Se-Weon;Oh, Ik-Hyun
    • Korean Journal of Materials Research
    • /
    • v.17 no.6
    • /
    • pp.342-346
    • /
    • 2007
  • Microstructure and tensile strength of the vacuum brazed stainless steel were investigated in this study. For vacuum brazing of the stainless steel 303 and 304, the BNi-2, 3, 4 and 7 were used as filler metals. Among these filler metals, the BNi-2 showed excellent wettability at $1050^{\circ}C$. Indeed, the brazed stainless steel using the BNi-2 showed the highest tensile strength (483 MPa) among all brazed specimens. This is attributed to degree of interfacial reaction between the filler metal and stainless steel. Brazed stainless steel with BNi-2, 3 filler metals showed almost elastic deformation followed by plastic yielding and strain hardening up to a peak stress. On the other hand, it is likely that the fracture of the brazed specimens with BNi-4, 7 was occurred in elastic range without plastic yielding up to a peak stress.

Physicochemical Properties of Chaga (Inonotus obliquus) Mushroom Powder as Influenced by Drying Methods

  • Lee, Min-Ji;Seog, Eun-Ju;Lee, Jun-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.12 no.1
    • /
    • pp.40-45
    • /
    • 2007
  • The effects of drying methods on the physicochemical properties of chaga (Inonotus obliquus) mushroom powder were investigated. Scanning electron micrograph revealed that freeze drying produced smaller particle- sized samples which in turn resulted in higher porosity than did vacuum and hot-air drying. Samples prepared by freeze drying showed a significantly higher L*-value as compared with those prepared by hot-air drying and vacuum drying (p<0.05). The lightness (L*-value) significantly decreased with increasing relative humidity and storage temperature regardless of drying method (p<0.05). The yellowness (b*-value) increased significantly with increasing relative humidity (p<0.05). Browning index was significantly lower in samples prepared by freeze drying (p<0.05) but not significantly different between samples dried by hot-air and vacuum drying. Freeze dried sample exhibited a significantly higher degree of rehydration than other samples (p<0.05) probably due to the small particle size. Water solubility of the freeze dried sample was higher than those of the other methods while swelling ratio of the same sample appeared to be lower than those of others. Freeze dried chaga mushroom powder contained significantly lower amount of total phenolics and total sugar as compared to other samples (p<0.05).

Numerical Analysis of Flow-Induced Noise and Fan Performance in Suction Nozzle of a Vacuum Cleaner with a Double-Blade Fan (이중 블레이드 팬이 장착된 진공청소기 흡입 노즐내 유로 유동 소음 및 팬 성능 해석)

  • Park, I-Sun;Sohn, Chae-Hoon;Lee, Sung-Cheol;Oh, Jang-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2632-2637
    • /
    • 2007
  • Rotary performance and flow resistance induced by each element in suction nozzle of a vacuum cleaner with a double-blade rotary fan are investigated numerically and its relation with flow-induced noise and rotary performance is examined. Flow resistance and vorticity in suction nozzle are calculated and it is found that they are closely related with flow-induced noise. Gap between double blades, adoption of cross-flow fan, enlargement of flow inlet area, and optimization of blade number are tested for noise reduction. Finally, the effects of each method are verified experimentally. It is found that several combinations of the proposed methods can be adopted for noise reduction although the degree of reduction is not much.

  • PDF

Thin Film Morphology Control of P3HT:PCBM Organic Solar Cells Using Electrospray Deposition Process

  • Hwang, Won-Tae;Choe, Su-Jeong;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.432-433
    • /
    • 2012
  • Polymer solar cells are fabricated using electrospray (e-spray) deposition process. It shows comparable performance with reference devices, and has different characteristics according to the thickness of the active layer: In the case of the devices with higher fill factor, it shows relatively lower current density, and vice versa. These films are characterized by atomic force microscopy measurement. The results indicate that the comparable power conversion efficiency made by e-spray results from the 'solvent annealing effect' by process conditions and the different thin film property is caused by the degree of self-organization of the polymer.

  • PDF