• Title/Summary/Keyword: Vacuum degree

Search Result 241, Processing Time 0.046 seconds

Influence of Drying Methods on Measurement of Hydration Degree of Hydraulic Inorganic Materials: 1) Ordinary Portland cement paste and mortar (수경성 무기재료의 수화도 측정에 대한 건조방법의 영향: 1) 보통 포틀랜드 시멘트 페이스트 및 모르타르)

  • Lee, Hyo Kyoung;Kim, Hyeong-Ki
    • Resources Recycling
    • /
    • v.27 no.1
    • /
    • pp.92-105
    • /
    • 2018
  • The present study was carried out to find a suitable drying method for measuring non-evaporable water contents of various hydraulic inorganic materials. In Part 1 of the paper, the case Ordinary Portland cement is discussed. Various drying methods including vacuum and oven drying, and an ignition, were used for the OPC paste and mortar having different w/c. The sole vacuum drying under room temperature led a fluctuation on measurement of hydration degree, while the sole oven drying also yielded unwanted hydration promotion at the early age. A combination of the vacuum and oven drying was considered as a suitable drying method for the OPC case.

characteristic of breakdown voltage of electrode material in vacuum (진공에서 전극 재질에 따른 절연파괴 전압 특성 파악)

  • Lee, Seung-Su;Her, June;Yoon, Jae-Hun;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.101-102
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm. The pressure of vacuum the range of 10^-4${\sim}$10^-5torr. The diameter of a plane made of the stainless steel is 150mm. As a result of the experiment, the breakdown voltage is increased about degree of vacuum increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Characteristic Evaluation of Vacuum Chamber for EBM System (전자빔 가공시스템용 진공환경의 성능평가)

  • Kang J.H.;Lee C.H.;Choi J.H.;Lim Y.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.934-937
    • /
    • 2005
  • It is not efficient and scarcely out of the question to use commercial expensive electron beam lithography system widely used for semiconductor fabrication process for the manufacturing application field of various devices in the small business scope. Then scanning electron microscope based electron beam machining system is maybe regarded as a powerful model can be used for it simply. To get a complete suite of thus proper system, proper chamber with high vacuum condition is necessarily required more than anything else to modify scanning electron microscope. In this study, special chamber unit using rotary pump and diffusion pump to obtain high vacuum degree was designed and manufactured and various evaluation tests fur recognize the vacuum characteristic were accomplished.

  • PDF

Vacuum system design of a 10 ton/day class air liquefaction cold box for liquid air energy storage

  • Sehwan, In;Juwon, Kim;Junyoung, Park;Seong-Je, Park;Jiho, Park;Junseok, Ko;Hankil, Yeom;Hyobong, Kim;Sangyoon, Chu;Jongwoo, Kim;Yong-Ju, Hong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.4
    • /
    • pp.65-70
    • /
    • 2022
  • A vacuum system is designed for thermal insulation of a 10 ton/day class air liquefaction cold box for liquid air energy storage. The vacuum system is composed of a turbomolecular pump, a backing pump and vacuum piping for the vacuum pumps. The turbomolecular pump is in combination with the backing pump for pumping capacity. The vacuum piping is designed with system installation conditions, such as distance from the cold box, connections to vacuum pumps and installation space. The capacity of the vacuum pump combination, namely pumping speed, is determined by analysis of the vacuum system, and pump-down time to 1×10-5 mbar is estimated. Vacuum piping conductance, system pumping speed and outgassing rate are calculated for the pump-down time with the ultimate pumping speed range of the vacuum pump combination of 1400 - 2300 l/s. Although the pump-down time gets shorter by larger capacity vacuum pumps, it mainly depends on target vacuum degree and outgassing rate in the cold box. The pump-down time is estimated as 3 - 6 hours appropriate for cold box operation for the pumping speed range. Considering the outgassing rate has uncertainty, the vacuum pump combination with pumping speed of 1900 l/s is chosen for the vacuum system, which is middle value of the pumping speed range.

Performance Analysis of a GPS Receiver under the Vacuum Environments (진공환경에서 GPS 수신기의 성능분석)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • In order to verify the operability of a GPS receiver which is one of the KSLV-I onboard electrical equipments under the vacuum conditions, this paper describes the operation methods and performance results of the GPS receiver under the thermal-vacuum and vacuum environments. The damages and degradations of electrical parts of the GPS receiver caused by the pressure change and high-degree vacuum conditions are analyzed in terms of tracking and navigation capabilities through the signal-to-noise ratio and navigation error.

  • PDF

Factors influencing related Health Promoting Life-Style in Middle-aged Women (중년여성의 건강증진 생활양식 관련요인분석)

  • Park, Myeung-Hee
    • Women's Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.157-179
    • /
    • 1997
  • The purpose of this study is to provide a basis for nursing intervention strategies to enhance health promoting practice that are constructive to a healthy lifestyle. Data were collected through self-reported questionnaires from 281 middle-aged women living in Seoul, Kyeung ki, Taegu, Kyeung pook, and Kyeung nam from July to September 1997. The following instruments were used in the study after some adaption : scale of perceived health status, self-esteem, perceived benefits, family hardiness index, purpose in life, Walker and other health promoting lifestyle profiles. The data were analyzed, by t-test, ANOVA Scheffe's Pearson's correlation & stepwise multiple regression, by using the SAS program. The results are as follows : 1) The average score for the health promoting lifestyle was 2.65. In the sub-categories, the highest degree of practice was self-actualization (2.91), and in the lower degree was health responsibility (2.13). 2) In the relation ship between social demographic and health promoting lifestyle there were significant differences ineducation, occupation, economic status, and type of family. 3) There is a significant correlation between perceived health status, self-esteem, perceived benefits, family hardiness index, existential vacuum and total & subcategory health promoting lifestyles. 4) Existential vacuum was the highest factor predicting a health promoting lifestyle for middle-aged women (38.0%). 5) Existential vacuum, commitment and self-esteem accounted for 45.9% of the total variance.

  • PDF

롤투롤 시스템을 적용한 메탈 메쉬 전극 소재의 특성 향상 연구

  • Byeon, Eun-Yeon;Choe, Du-Ho;Kim, Do-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.133.2-133.2
    • /
    • 2016
  • 차세대 디스플레이로 유연하고 투명한 기능들이 요구되면서 Indium Tin Oxide(ITO)를 대체하기 위한 투명전극 개발 연구가 많이 수행되고 있다. ITO는 높은 투과도와 낮은 저항으로 현재 가장 많이 활용되고 있는 투명전극 소재이지만 유연성이 떨어져 유연 터치 패널 소재로 활용하기 어렵다. 이러한 문제 해결을 위해 ITO 대체 물질로 CNT, Graphene, Metal mesh, Ag nano wire, 전도성 고분자 등의 차세대 투명 전극 소재가 대두되고 있다. 본 연구에서는 메탈 메쉬 전극 소재로 사용하기 위해 Cu 박막 증착 시 플라즈마 표면처리를 통해 밀착력 및 저항을 개선하였다. Cu 금속 박막의 양산화를 위한 공정으로 자체 제작한 Linear Ion Source(LIS)가 부착된 roll to roll 시스템을 적용하여 플라즈마 전처리 공정 및 Ni buffer layer 도입 이후 Cu 박막을 형성하였다. 그 결과 PET 기판과 Cu 박막 사이의 밀착력을 0 degree에서 5 degree까지 향상시킬 수 있었고, 플라즈마 표면처리를 시행함으로써 저항 또한 감소되는 결과를 얻을 수 있었다. 본 연구를 통해서 폴리머 기판 소재에 in-situ로 표면처리 및 Cu 금속 박막을 증착함으로써 금속 박막의 밀착력 및 전기적 특성이 향상되는 공정 기술을 개발하였다.

  • PDF

Formation of Neutral Beam by Low Angle Reflection

  • Lee, Do-Haing;Jung, Min-Jae;Bae, Jung-Woon;Kim, Sung-Jin;Lee, Jae-Koo;Yeom, Geun-Young
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.23-26
    • /
    • 2003
  • In this study, a neutral beam was formed using a low angle forward reflection of the ion beam and its degree of neutralization at different reflection angles was investigated. When the ion beam was reflected by a reflector at the angles lower than 15$^{\circ}$, most of the ions reflected were neutralized and the lower reflector angle showed the higher degree of neutralization. Photoresist(PR) and SiO$_2$ etchings were carried out with the neutralized oxygen and fluorine radical fluxes, respectively, and highly anisotropic etch profiles could be obtained suggesting the formation of highly directional neutral flux.

  • PDF

Ultrasound-Aided Monolayer Assembly of Spherical Silica Nanobeads

  • Yun, Sang-Hui;Yun, Seo-Yeong;Lee, Jin-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.267.1-267.1
    • /
    • 2013
  • In modern science and technology, the organization of building blocks, such as spherical particles and zeolite, is important to form a nanostructure. So, it is essential to develop methods for organizing them into large scale for many precise applications. Up to now, reflux and stirring is widely used method for organization of colloidal particles. However, because this method is hard to organize building block with high coverage and uniform orientation, it is necessary to research another method. In this work, we synthesized spherical silica particles using St$\"{o}$ber method and organized them on the glass which is coated with 3-chloropropyltrimethoxysilane (CP-TMS) and polyethyleneimine (PEI) using Sonication method. Although spherical silica particles are difficult to attach on the glass due to their small attachment site, we improved this problem by coating PEI. We introduced two mode of reaction promotion, sonication (SO) and sonication with stacking between the bare glass (SS), and investigated degree of coverage (DOC) and degree of close packing (DCP).

  • PDF