• Title/Summary/Keyword: Vacuum degree

Search Result 241, Processing Time 0.026 seconds

Comparison of Intramuscular Lipid Oxidation in Porcine Muscle (근섬유간 지질의 산패에 관한 비교연구)

  • Yang, Ryung;Lee, Hyeong-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.6-14
    • /
    • 1991
  • Intramuscular lipid of longissimus dorsi muscle(white muscle), soleus muscle(red muscle) and cardiac muscle were autooxidized at $37^{\circ}C$ for 20 days, and the rancidity development and the effect of various factors on rancidity development were compared. Although the myoglobin content of red muscle was about 5 times as high as that of white muscle, the degree of autooxidation occurred in intramuscular lipid did not differ between red muscle and white muscle, when they had the same lipid content. Accordingly, it was suggested that the susceptibility of muscle tissues to lipid oxidation depends mainly on the lipid content of muscle tissue, regardless of muscle types. Lipid oxidation was not a major quality deterioration for dried-pork product, when it contained adequate amount of sodium nitrite and was air-tight vacuum-packed.

  • PDF

Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant (냉매 내 공기혼입에 따른 에어컨 시스템의 냉각성능 저하)

  • Moon, Seong-Won;Min, Young-Bong;Chung, Tae-Sang
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.470-475
    • /
    • 2009
  • This study was performed to present the diagnosis basis of cooling performance deficiency according to air quantity included in refrigerant of air-conditioner by detecting the temperatures and pressures of refrigerant pipeline. The car air-conditioner of SONATA III (Hyundai motor Co., Korea) was tested by maximum cooling condition at 1500 rpm of engine speed in the room with controlled air condition at $33\sim35^{\circ}C$ and 55~57% RH. Measured variables were temperature differences between inlet and outlet pipe surface of the compressor (Tcom), condenser (Tcon), receive dryer (Trec) and evaporator (Teva), and high pressure (HP) and low pressure (LP) in the refrigerant pipeline, and temperature difference (Tcoo) between inlet and outlet air of the cooling vent of evaporator. Control variables were the refrigerant charging weight and the vacuum degree in the refrigerant pipeline before charging refrigerant. From the test, it was represented that the measuring values of (Tcom), LP and (Tcoo) were enabled to make the diagnosis of cooling performance deficiency according to quantity included in refrigerant of air-conditioner. The ranges of Tcom, LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively less than $55^{\circ}C$, more than 166.7 kPa-g(1.7 kgf/$cm^2$) and less than $13.7^{\circ}C$. In the case of using only external sensors and the condition under the normal performances of air conditioner, it was considered that the ranges of LP and Tcoo to make the diagnosis of cooling performance deficiency were respectively more than 166.7 Pa and less than $12^{\circ}C$.

Changes in the Chemical Structure and the Thermal/Physical Properties of Fluoropolymer Films Induced by Gamma Irradiation under Various Environments (다양한 환경에서 감마선으로 조사된 불소고분자 필름들의 구조 및 열적/물성 변화)

  • Choi, Ji Sun;Sohn, Joon-Yong;Shin, Junhwa
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.457-463
    • /
    • 2014
  • In this study, the changes in the chemical structure and the physical property of fluoropolymer films (PTFE, FEP, PFA, PVDF, and ETFE) induced by $Co^{60}$ gamma ray in air, $N_2$, and vacuum environments were investigated. FTIR spectra of the irradiated fluoropolymers indicate that the oxidation proceeded by the reaction of radicals generated by irradiation with oxygen in air. The changes in the heat of fusion and the degree of crystallinity of the irradiated fluoropolymers were investigated using DSC and the results indicate that the scission and crosslinking reactions of the irradiated fluoropolymers were largely influenced by the chemical structure. It was also found that the mechanical property of the irradiated fluoropolymer films under an air atmosphere was significantly decreased.

Effects of Annealing Conditions on the Properties of Bi1-xLaxTi3O12 Thin Films (열처리 조건이 Bi1-xLaxTi3O12 (x=0.75) 박막의 특성에 미치는 효과)

  • Park Moon Heum;Kim Sang Su;Gang Min Ju;Ha Tae Gon
    • Korean Journal of Materials Research
    • /
    • v.14 no.10
    • /
    • pp.701-706
    • /
    • 2004
  • Bismuth layered structure ferroelectric thin films, La-substituted $Bi_{4}Ti_{3}O_{12}$ ($Bi_{1-x}La_{x}Ti_{3}O_{12}$, x=0.75, BLT) were prepared on the $Pt(111)/Ti/SiO_2/Si(100)$ substrates by a sol-gel spin coating process. The thin films were annealed in various conditions, i.e., oxygen, nitrogen and vacuum atmospheres for various annealing time. We investigated the annealing condition effects on the grain orientation and ferroelectric properties. The measured XRD patterns revealed that the BLT thin films showed only $Bi_{4}Ti_{3}O_{12}$-type phase with random orientation. $La^{3+}$ ion substitution for $Bi^{3+}$ ion in perovskite layers of $Bi_{4}Ti_{3}O_{12}$ decreased the degree of c-axis orientation and increased the remanent polarization ($2P_{r}$). The remanent polarization ($2P_{r}$) and the coercive field ($2E_{c}$) of the BLT thin film annealed at $650^{\circ}C$ for 5 min in oxygen atmosphere were $87{\mu}C/cm^2$ and 182 kV/cm, respectively, at an applied electric field of 240 kV/cm. For all of the BLT thin films annealed in various conditions, the fatigue resistance was shown. The improvement of ferroelectric properties with La substitution in $Bi_{4}Ti_{3}O_{12}$ could be attributed to the changes in space charge densities and grain orientation in the thin film.

A Study on the Characteristic of Gas Pore Formation in Lost Foam Casting of Mg alloy;Comparison with Al alloy (마그네슘 합금의 소실모형주조 시 기포형성 특성에 관한 연구;알루미늄 합금과 비교)

  • Shin, Seung-Ryoul;Han, Sang-Won;Lee, Kyong-Whoan
    • Journal of Korea Foundry Society
    • /
    • v.24 no.3
    • /
    • pp.165-174
    • /
    • 2004
  • The pore formation characteristic of Mg alloy during Lost Foam Casting(LFC) was investigated with reduced pressure test and real casting, which was compared with the results of previous work for Al alloy. Cast Mg alloys in LFC had much lower porosities in comparison with those of Al alloys. Also, the proper pouring temperature gave the minimum porosity like Al alloy although it was higher than that of Al alloys due to the worse fluidity of Mg alloy. The pore formation mechanism of Mg alloy in LFC was similar to that of AI alloy but the critical temperature showing the different mechanism is higher than that of Al alloy as much as $30{\sim}50^{\circ}C$. The result that Mg alloy in LFC had the lower porosity comparing with Al alloy was due to the extra solubility of hydrogen gas although the solubility of Al alloy was easily exceeded by the external sources like pyrolyzed polystyrene products. The mold evacuation gave the lower porosity due to the removal of polystyrene pyrolysis products, and reduced shrinkage defects. Also, there was a proper evacuation pressure that gave a porosity of almost 0vol%. But much higher vacuum degree than this proper pressure caused the severe entrapment of polymer pyrolysis products that gave the large porosity.

Properties of Diamond-like Carbon(DLC) Thin Films deposited by Negative Ion Beam Sputter (I) (Negative ion beam sputter 법으로 증착한 DLC 박막의 특성 (I))

  • Kim, Dae-Yeon;Gang, Gye-Won;Choe, Byeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.10 no.7
    • /
    • pp.459-463
    • /
    • 2000
  • Direct use of negative ions for modification of materials has opened new research such as charging-free ion implantation and new materials syntheses by pure kinetic bonding reactions. For these purposes, a new solid-state ce-sium ion source has been developed in the laboratory scale. In this paper, diamond like carbon(DLC) films were prepared on silicon wafer by a negative cesium ion gun. This system does not need any gas in the chamber; deposition occurs under high vacuum. The ion source has good control of the C- beam energy(from 80 to 150eV). The result of Raman spectrophotometer shows that the degree of diamond-like character in the films, $sp^3$ fraction, increased as ion beam energy increases. The nanoindentation hardness of the films also increases from 7 to 14 GPa as a function of beam energy. DLC films showed ultra-smooth surface(Ra~1$\AA$)and an impurity-free quality.

  • PDF

A Study of Reactively Sputtered Ti-Si-N Diffusion Barrier for Cu Metallization (혼합기체 sputtering 법으로 증착된 Cu 확산방지막으로의 Ti-Si-N 박막의 특성 연구)

  • Park, Sang-Gi;Lee, Jae-Gap
    • Korean Journal of Materials Research
    • /
    • v.9 no.5
    • /
    • pp.503-508
    • /
    • 1999
  • We have investigated the physical and diffusion barrier property of Ti-Si-N film for Cu metallization. The ternary compound was deposited by using reactive rf magnetron sputtering of a TiSi$_2$target in an Ar/$N_2$gas mixture. Resistivities of the films were in range of 358$\mu$$\Omega$-cm, to 307941$\mu$$\Omega$-cm, and tended to increase with increasing the $N_2$/Ar flow rate ratio. The crystallization of the Ti-Si-N compound started to occur at 100$0^{\circ}C$ with the phases of TiN and Si$_3$N$_4$identified by using XRD(X-ray Diffractometer). The degree of the crystallization was influenced by the $N_2$/Ar flow ratio. The diffusion barrier property of Ti-Si-N film for Cu metallization was determined by AES, XRD and etch pit by secco etching, revealing the failure temperature of 90$0^{\circ}C$ in 43~45at% of nitrogen content. In addition, the very thin compound (10nm) with 43~45at% nitrogen content remained stable up to $700^{\circ}C$. Furthermore, thermal treatment in vacuum at $600^{\circ}C$ improved the barrier property of the Ti-Si-N film deposited at the $N_2$(Ar+$N_2$) ratio of 0.05. The addition of Ti interlayer between Ti-Si-N films caused the drastic decrease of the resistivity with slight degradation of diffusion barrier properties of the compound.

  • PDF

Characteristics of Brazed Joint of Sintered Bronze/steel Using Ag-Cu-Zn Type Filler Materials (Ag-Cu-Zn-Cd 계 용가재를 이용한 Bronze 소결체/강의 브레이징 접합부 특성 평가)

  • 이정훈;이창희
    • Journal of Welding and Joining
    • /
    • v.17 no.3
    • /
    • pp.79-89
    • /
    • 1999
  • The study was carried out to examine in more detail metallurgical and mechanical properties of brazed joints of diamond cutting wheel. In this work, shank(mild steel) and sintered bronze-base tips were brazed with three different filler materials(W-40, BAgl and BAg3S). The machine used in this work was a high frequency induction brazing equipment. The joint thickness, porosities and microstructure of brazed joints with brazing variables(brazing temperature, holding time) were evaluated with OLM, SEM, EDS and XRD. Bending(torque) test was also performed to evaluate strength of brazed joints. Further wetting test was performed in a vacuum furnace in order to evaluate the wettability of filler metals on base metals9shank and tips). The brazing temperature had a strong influence on the joint strength and the optimum brazing temperature range was about $700~850^{\circ}C$ for the bronze/steel combinations. The strength of the brazed joint was found to be influenced by the three factors : degree of reaction region, porosity content, joint thickness. The reaction region was formed in the bronze-base tip adjacent to the joint. The reaction region resulted in a bad influence on the strength due to the formation of Cu5.6Sn, CuZn4, $\beta(CuZn)$ and CdAg, etc. Porosities increased as brazing variables(brazing temperature, holding time) increased, and the brazed joints with porosities of less than about 3-5% had an optimum strength for the bronze-base tip.

  • PDF

Effects of dentin moisture on the push-out bond strength of a fiber post luted with different self-adhesive resin cements

  • Turker, Sevinc Aktemur;Uzunoglu, Emel;Yilmaz, Zeliha
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.234-240
    • /
    • 2013
  • Objectives: This study evaluated the effects of intraradicular moisture on the pushout bond strength of a fibre post luted with several self-adhesive resin cements. Materials and Methods: Endodontically treated root canals were treated with one of three luting cements: (1) RelyX U100, (2) Clearfil SA, and (3) G-Cem. Roots were then divided into four subgroups according to the moisture condition tested: (I) dry: excess water removed with paper points followed by dehydration with 95% ethanol, (II) normal moisture: canals blot-dried with paper points until appearing dry, (III) moist: canals dried by low vacuum using a Luer adapter, and (IV) wet: canals remained totally flooded. Two 1-mm-thick slices were obtained from each root sample and bond strength was measured using a push-out test setup. The data were analysed using a two-way analysis of variance and the Bonferroni post hoc test with p = 0.05. Results: Statistical analysis demonstrated that moisture levels had a significant effect on the bond strength of luting cements (p < 0.05), with the exception of G-Cem. RelyX U100 displayed the highest bond strength under moist conditions (III). Clearfil SA had the highest bond strength under normal moisture conditions (II). Statistical ranking of bond strength values was as follows: RelyX U100 > Clearfil SA > G-Cem. Conclusions: The degree of residual moisture significantly affected the adhesion of luting cements to radicular dentine.

Non-uniform Distribution of Magnetic Fluid in Multistage Magnetic Fluid Seals

  • Zhongzhong, Wang;Decai, Li;Jing, Zhou
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.299-305
    • /
    • 2017
  • Magnetic fluid, a new type of magnetic material, is a colloidal liquid constituted of nano-scale ferromagnetic particles suspended in carrier fluid. Magnetic fluid sealing is one of the most successful applications of magnetic fluid. As a new type of seal offering the advantages of no leakage, long life and high reliability, the magnetic fluid seal has been widely utilized under vacuum- and low-pressure-differential conditions. In practical applications, for improved pressure capacity, a multistage sealing structure is always used. However, in engineering applications, a uniform distribution of magnetic fluid under each tooth often cannot be achieved, which problem weakens the overall pressure capacity of the seals. In order to improve the pressure capacity of magnetic fluid seals and broaden their applications, the present study theoretically and experimentally analyzed the degree of non-uniform distribution of multistage magnetic fluid seals. A mathematical model reflecting the relationship between the pressure capacity and the distribution of magnetic fluid under a single tooth was constructed, and a formula showing the relationship between the volume of magnetic fluid and its contact width with the shaft was derived. Furthermore, the relationship of magnetic fluid volume to capacity was analyzed. Thereby, the causes of non-uniform distribution could be verified: injection of magnetic fluid; the assembly of magnetic fluid seals; the change of magnetic fluid silhouette under pressure loading; the magnetic fluid sealing mechanism of pressure transmission, and seal failure. In consideration of these causes, methods to improve the pressure capacity of magnetic fluid seals was devised (and is herein proposed).