• Title/Summary/Keyword: Vacuum degassing

Search Result 25, Processing Time 0.028 seconds

Membrane Degassing Process of Sweep Gas-vacuum Combination Type for Ammonia Removal (스윕 가스-진공 혼합식 탈기막 시스템을 활용한 암모니아 제거)

  • Yoon, Hongsik;Min, Taijin;Lee, Gunhee;Kim, Hyoung-Tak;Shin, Wanho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.835-842
    • /
    • 2022
  • In this study, the membrane degassing process of the sweep gas - vacuum combination type was proposed for ammonia wastewater treatment. The effect of pH, initial ammonia concentration and scale-up on ammonia degassing performance was investigated. As a result, as the pH and the initial ammonia concentration increased, the degassing permeate flux was improved. On the other hand, the ammonia mass transfer coefficient increased as the initial ammonia reduced, which seems to be due to the driving force of the sweep gas-vacuum combination type membrane degassing system proposed in this study. In addition, 80 mg NH3/min of the ammonia degassing rate was achieved using a 6×28 inch size module. Better degassing performance is expected if consideration for maintaining vacuum pressure is involved in the scale-up design.

EFFECT OF DEGASSING CONDITION ON CERAMIC BOND STRENGTH OF Ni-Cr ALLOYS (Degassing 조건이 Ni-Cr 합금의 도재결합력에 미치는 영향)

  • Lee, Eun-Hwa;Jeon, Young-Chan;Jeong, Chang-Mo;Lim, Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.461-471
    • /
    • 2000
  • This study evaluated the effect of degassing on the ceramic bond strength of two Ni-Cr alloys under varying holding time at the upper limit temperature and atmospheric conditions. Metal specimens were divided into 5 groups for each alloy according to degassing conditions prior to porcelain application no degassing, degassing under vacuum without hold, degassing under vacuum with hold for 5 min. and 10 min. respectively at the upper limit temperature and degassing in air. Total number of metal ceramic specimens was eighty and each group had eight specimens. The ceramic bond strength was measured by four-point flexural test using Instron and the fractured surface was examined under SEM. The results obtained were as follows. 1. Degassing in air improved the ceramic bond strength of Ni-Cr alloys. 2. In degassing under vacuum, hold at the upper limit temperature was advantageous to the ceramic bonding of Ni-Cr alloys. 3. After ceramic metal bond test, metal surfaces were partially covered with the thin porcelain layer, and the cohesive failures in porcelain were predominant in groups showing higher ceramic bond strength.

  • PDF

Changes in the Surface Characteristics of Gas-atomized Pure Aluminum Powder during Vacuum Degassing

  • Yamasaki, Michiaki;Kawamura, Yoshihito
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1039-1040
    • /
    • 2006
  • Vacuum degassing is essential in the preparation of RS P/M aluminum alloys to remove adsorbates and for the decomposition of hydrated-$Al_{2}O_3$ on the powder surface. Changes in the surface characteristics during vacuum degassing were investigated by X-ray photoelectron spectroscopy and temperature-programmed desorption measurement. Hydrated-$Al_{2}O_3$ decomposition to crystalline-$Al_{2}O_3$ and hydrogen desorption on the surface of argon gas-atomized aluminum powder occurred at 623 K and 725 K, respectively. This temperature difference suggests that the reaction converting hydrated-$Al_{2}O_3$ to crystalline-$Al_{2}O_3$ during vacuum degassing should be divided into the two reactions $"2Al+Al_{2}O_3{\cdot}3H_2O\;2Al_{2}O_3+6H_{surf}"and"6H_{surf}3H_2"$.

  • PDF

Ammonia Wastewater Treatment and Selective Recovery Using a Sweep Gas-Vacuum Hybrid Type Membrane Degassing Process (스윕 가스-진공 하이브리드식 탈기막 공정을 활용한 암모니아 폐수처리 및 선택적 회수)

  • Hongsik Yoon;Taijin Min;Minkyu Jeon;Sungil Lim;Sechul Oh;Kyungha Ryu;Chungsung Lee;Bosik Kang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1171-1181
    • /
    • 2023
  • In this study, a sweep gas - vacuum hybrid type membrane degassing process was proposed for ammonia wastewater treatment. In addition, the ammonia selective recovery of the hybrid type membrane degassing process was also investigated. As a result, the hybrid type membrane degassing process showed better degassing performance (54.9 mg NH3/m2min for 360 min) than the sweep gas type (32.3 mg NH3/m2min) or vacuum type (22 mg NH3/m2min). Additionally, the hybrid type membrane degassing process showed an excellent ammonia selectivity (103 times compared to Na+ Na+, 133 times compared to Ca2+). The ammonia selectivity was appeared to be due to the conversion characteristics of ammonium ion / dissolved ammonia depending on pH. The results in this study are expected to be used in the development of ammonia wastewater treatment and ammonia recovery in the future.

Adsorption of p-Nitrophenol by Surface Modified Carbons from Aqueous Solution

  • Goyal, Meenakshi
    • Carbon letters
    • /
    • v.5 no.2
    • /
    • pp.55-61
    • /
    • 2004
  • Adsorption isotherms of p-nitrophenol from its aqueous solutions on two samples of activated carbon fibres and two samples of granulated activated carbons have been determined in the concentration range 40~800 mg/L (ppm). The surface of these carbons was modified by oxidation with nitric acid and oxygen gas, and by degassing the carbon surface under vacuum at temperatures of $400^{\circ}C$, $650^{\circ}C$ and $950^{\circ}C$. The oxidation of carbon enhances the amount of carbon-oxygen surface groups, while degassing decreases the amount of these surface groups. The adsorption of p-nitrophenol does not depend upon the surface area alone but appears to be influenced by the presence of oxygen groups on the carbon surface. The adsorption decreases on oxidation while the degassing of the carbon surface enhances the adsorption. The decrease in adsorption depends upon the strength of the oxidative treatment being much larger in case of the oxidation with nitric acid, while the decrease in adsorption on degassing depends upon the temperature of degassing. The results show that while the presence of acidic surface groups which are evolved as $CO_2$ on degassing suppress the adsorption of p-nitrophenol, the presence of non acidic surface groups which are evolved as CO on degassing tend to enhance the adsorption. Suitable mechanisms compatible with the results have been presented.

  • PDF

A Study on Bond Strength of Procelain with Non Precious Alloy (도재전장관용 비귀금속합금과 도재의 융착결합에 관한 연구)

  • Kang, Sung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.49-57
    • /
    • 1980
  • The adhesive mechanisms on the metal-ceramic restorations have been reported to be mechanical interlocking, chemical bonding, compressive force, and Van der Waal's force, etc. Of these, the mechanical interlocking and chemical bonding forces are thought to affect the adhesive force between Ni-Cr alloy and porcelain. This study investigates the adhesion of Ni-Cr alloy to porcelain according to surface treatment. For this purpose, the following experiments were made; The compositions of Ni-Cr alloy as cast by emission spectrograph, and the oxides produced on Ni-Cr alloy during degassing at $1850^{\circ}F$ for 30 minutes in air and in vacuum were analyzed by X-ray diffractograph. The metal phases of Ni-Cr alloy were observed according to porcelain-baking cyclic heat treatment by photo microscope and the distribution and the shift of elements of Ni-Cr alloy and porcelain and the failure phases between Ni-Cr alloy and porcelain by scanning electron microscope. The adhesive force between Ni-Cr alloy and porcelain was measured according to surface treatment with oxidization and roughening by Instron Universal Testing Machine. Results were as follows; 1. The metal phases of Ni-Cr alloy as cast and degassing state showed the enlarged and fused core, but when subjected to porcelain-baking cyclic heat treatment, showed a dendrite growing. 2. The kinds of metal oxides produced on Ni-Cr alloy during degassing were found to be NiO and $Cr_2O_3$. 3. The distribution of elements at the interface of Ni-Cr alloy and porcelain in degassing state showed demarcation line, but in roughening state, showed mechanical interlocking phase. 4. The shift of elements at the interface occurred in both states, but the shift amount was found to be larger in roughening than in degassing. 5. The adhesive force between Ni-Cr alloy and porcelain was found to be $3.45{\pm}0.93kg/mm^2$, in degassing and $3.82{\pm}0.99kg/mm^2$, in roughening. 6. The failure phase between Ni-Cr alloy and porcelain showed the mixed type failure.

  • PDF

Technology Trends in Vacuum Pumping

  • Ormrod, Stephen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.59-59
    • /
    • 2012
  • Vacuum pumping remains central to the performance and economy of many manufacturing processes, scientific instruments and scientific research. More vacuum is being used in many of the latest or leading edge manufacturing processes: Current examples include 3D semiconductor devices, EUV lithography, 450 mm silicon wafers, AMOLED displays, LEDs, Lithium-ion batteries and steel degassing. In other applications, vacuum pumping technology developments have led to much lower product costs which for example have enabled mass spectrometers to become a ubiquitous tool is life science research. Vacuum pumps have continuously evolved during the past 100 years of vacuum-based industrial processing but remain a key component which is often on the critical path of process and product improvements. This is especially so in the growing number of applications where the pumps are highly stressed. This presentation outlines significant developments in vacuum that have brought about this progress. The likely course of continued improvements is discussed in terms of increased performance and reliability, robust by-product handling, better cost efficiency and reduced environmental impact especially power consumption.

  • PDF

성막직전 기판 열처리가 롤투롤 스퍼터를 이용하여 성장시킨 터치 패널용 ITO 투명 전극의 특성 미치는 효과 연구

  • Kim, Dong-Ju;Kim, Bong-Seok;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.416-416
    • /
    • 2010
  • 본 연구에서는 저가격, 대면적화를 위한 롤투롤 스퍼터를 설계&개발하고, 성막직전 PET 기판의 열처리 유무를 통한 ITO 박막을 성막 시킨 저항막 방식의 터치 패널용 투명 전극에 대하여 전기적, 광학적, 구조적, 표면적 특성을 분석하였다. 롤투롤 스퍼터는 degassing챔버와 스퍼터 챔버가 한 시스템에 구성되었고, Degassing 챔버는 좌우측의 Rewinder/Unwinder 롤러에 의해 감고 풀어지는 PET기판의 수분 및 가스를 중앙부에 위치한 히터를 통해 제거하며, 수분 제거 후 스퍼터 챔버로 옮겨진 1250 mm폭의 PET기판을 Unwinder/Rewinder 롤러에 장착하며, Unwinder 롤러로부터 풀려진 PET 기판은 guide 롤러를 거쳐 cooling drum과의 물리적 접촉에 의해 PET 기판의 냉각이 일어나게 된다. ITO 캐소드 전에 장착된 할로겐 히터 상부로 기판이 지나가면서 열처리가 진행되고 열처리 후 두 개의 ITO 캐소드 상부를 지나면서 연속적으로 ITO 박막이 PET 기판에 성막 되게 된다. ITO 박막의 주요 성막 변수인 DC Power, Ar/$O_2$ 가스 유량비, 기판의 속도는 최적으로 고정하고, 성막 직전 기판의 열처리에 유무에 따른 ITO박막의 필름을 각각 고온 챔버에서 $140^{\circ}C{\times}90min$ 동안 열처리를 통한 내열성 테스트를 진행하여 ITO 필름의 특성 향상을 비교 분석하였다. 분석을 위해 전기적 특성은 four-point probe로 측정했고, 투과도는 Nippon Denshoku사(社)의 COH-300A를 이용해 가시광(550nm)에서 분석했고, FE-SEM으로 ITO박막 의 표면 상태를 분석하였다. 또한 Bending Tester(Z-100)를 이용하여 기계적 안정성을 분석하였다. 성막직전 PET 기판의 열처리를 하지 않은 ITO박막은 고온의 챔버 에서 $140^{\circ}C{\times}90min$ 동안 내열성 테스트 후 면저항이 511($\omega/\Box$)에서 630($\omega/\Box$)으로 높아졌으나, 성막직전 열처리를 통한 ITO 박막인 경우에는 465($\omega/\Box$)에서 448($\omega/\Box$)로 안정화 되었고, 투과율은 성막직전 열처리를 통해 1%향상되어 89%를 보였고, 유연성 또한 보다 우수한 특성을 보였다. 표면 조도는 평균 0.416 nm의 낮은 값을 보였다. 이는 PET 기판의 degassing 공정 중 충분히 제거되지 않은 가스나 불순물을 성막직전 열처리 공정으로 충분히 제거하여 깨끗한 PET 기판 상에 ITO 박막을 성막시키고, 열처리시 기판에 주어진 열에너지에 의해 보다 밀도가 높은 ITO 박막이 성장했기 때문으로 사료 된다.

  • PDF

롤투롤 스퍼터를 이용하여 성장시킨 정전용량 방식의 터치 패널용 ITO 투명 전극 특성 연구

  • Kim, Dong-Ju;Kim, Bong-Seok;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.306-306
    • /
    • 2013
  • 본 연구에서는 저가격, 대면적화를 위한 롤투롤 스퍼터를 이용하여, Index matching (히가시 야마 $125{\mu}m$)의 PET 기판 위에 ITO 박막을 성막 시킨 정전용량 방식의 터치 패널용 투명 전극에 대하여 전기적, 광학적, 구조적, 표면적 특성을 분석하였다. ITO 타겟은 미쓰이사(일본의) 주석 함량 5 wt%을 사용하였으며, 롤투롤 스퍼터는 degassing챔버와 스퍼터 챔버가 한 시스템에 구성되었고, Degassing 챔버는 좌우측의 Rewinder/Unwinder 롤러에 의해 감고 풀어지는 PET 기판의 수분 및 가스를 중앙부에 위치한 히터를 통해 제거하며, 수분 제거 후 스퍼터 챔버로 옮겨진 1,250 mm폭의 PET기판을 Unwinder/Rewinder 롤러에 장착하며, Unwinder 롤러로부터 풀려진 PET 기판은 guide 롤러를 거쳐 cooling drum과의 물리적 접촉에 의해 PET 기판의 냉각이 일어나게 된다. ITO 캐소드 전에 장착된 할로겐 히터 상부로 기판이 지나가면서 열처리가 진행되고 열처리 후 두 개의 ITO 캐소드 상부를 지나면서 연속적으로 ITO 박막이 PET 기판에 성막 되게 된다. ITO 박막의 주요 성막 변수인 DC Power, Ar/$O_2$ 가스 유량비, 기판의 속도는 최적으로 고정하고, 성막된 ITO박막의 필름을 각각 고온 챔버에서 $150^{\circ}C$도에서 10 min에서 60 min 동안 각각 열처리를 통한 내열성 테스트를 진행하여 ITO 필름의 특성 향상을 비교 분석하였다. 분석을 위해 전기적 특성은 four-point probe로 측정했고, 투과도는 Nippon Denshoku사(社)의 COH-300A를 이용해 가시광(550 nm)에서 분석했고, FE-SEM으로 ITO박막의 표면 상태를 분석하였다. 또한 Rolling Tester (Z-300)를 이용하여 기계적 안정성을 분석하였다.

  • PDF