• Title/Summary/Keyword: Vacuum Switch

Search Result 60, Processing Time 0.038 seconds

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

Development of the Crowbar System Using a Vacuum Switch (진공 스위치를 이용한 Crowbar 시스템의 개발)

  • 이태호;허창수;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

Characterization of the Hydrogen Reservoir for a High Power Gas Switch

  • Lee, B.J.;Park, S.S.;Kim, S.H.;Kwon, S.J.;Jang, S.D.;Joo, Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.261-261
    • /
    • 2012
  • This paper presents the understandings carried out for the installation of the hydrogen reservoir of the multi-gap pseudospark switch under developing for the accelerator applications. As a cold cold cathode switch, the pseudospark switch could replace the thyratron switch which has hot cathode and being used well currently in the high power field such as laser and accelerator applications. Especially in the klystron modulator, the key component is a switch which mostly defines the jitter and the instability of the modulator system. To get the less jitter and the instability, we need to find proper range of the pressure for the gas discharge inside gas switch. This could be achieved by the understanding of the characteristic of the nonevaporable getter (NEG) which is used as a hydrogen reservoir for the switch. Therefore we verified the characteristics of the NEG (St 172, Saes) and its installation in the switch. Finally we controlled the getter to find best pressure point for the pseudospark switch.

  • PDF

Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current (고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Hong, M.S.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

The research of dependency between trigger condition and trigger geometry for triggered vacuum switch

  • Park, Ung-Hwa;Kim, Mu-Sang;Son, Yun-Gyu;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.228.2-228.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) discharges high current through two processes. In the first process, an igniting plasma is generated at a trigger system, and the next process that a main discharge is taken place sequentially at a six-gap rod electrode within a few microsecond. In general, a triggered voltage producing the igniting plasma is increased. However, after several hundred shots, it goes down and stable, in our experiment the trigger voltage is about 5 kV after 250 shots. This triggered characteristics comes from the ceramic insulator which is covered by an electrode material, therefore we have focused on the first igniting plasma process. The igniting plasma has been generated at the surface of a ceramic insulator under a strong electric field. The electric field can be increased through modifying geometries of trigger components which compose of a trigger pin, a ceramic insulator and an enclosed holder. We fabricated not only two types of trigger pin which are a plane head and an umbrella head type, but two different holders which are a concave and a convex type. In this paper the result that the dependency of geometries for these four combined types is included, but the study of the ceramic insulator is not. The research of the ceramic insulator will be announced in the other paper.

  • PDF

A study on the design of triggering pulse generator for the triggered vacuum switch (진공스위치 트리거 발생기 설계에 관한연구)

  • Kim, Mu-Sang;Son, Yun-Gyu;Park, Ung-Hwa;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

A Technical Trend on Automatic Vacuum Capacitor Switch with Modified Digital Filter Design (디지털 필터 설계를 이용한 자동 진공 콘덴서 스위치의 기술 동향)

  • Oh, Gi-Soo;Chang, Young-Ho;Yun, Ju-Ho;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1978-1979
    • /
    • 2007
  • In this paper, the authors introduce a high-speed microprocessor based on automatic vacuum capacitor switch with a modified digital filter design using distributed arithmetic. The automation trends particularly the automatic vacuum capacitor switch has helped ameliorate the power factor essentials and automatically triggered to close when the line current exceeds rated value. Microprocessor relays use digital filters to extract only the fundamental and attenuate harmonics. To provide optimum speed characteristics a distributed arithmetic based filter design in the microprocessor controller which not only enhances filtering speed but additionally enables lower power consumption at the cost of area has been introduced. The result is a unified description that describes a digital filter structure down to bit level.

  • PDF

Characterization of the Hydrogen Reservoir for a High Power Gas Switch

  • Lee, Byeong-Jun;Park, Seong-Su;Kim, Sang-Hui;Gwon, Se-Jin;Jang, Seong-Deok;Mun, Yong-Jo;Ju, Yeong-Do;Kim, Chang-Beom;Hwang, Il-Mun;Sin, Seung-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.547-547
    • /
    • 2013
  • This paper presents the understandings carried out for the installation of the hydrogen reservoir of the multi-gap pseudospark switch under developing for the accelerator applications. As a cold cold cathode switch, the pseudospark switch could replace the thyratron switch which has hot cathode and being used well currently in the high power field such as laser and accelerator applications. Especially in the klystron modulator, the key component is a switch which mostly defines the jitter and the instability of the modulator system. To get the less jitter and the instability, we need to find proper range of the pressure for the gas discharge inside gas switch. This could be achieved by the understanding of the characteristic of the nonevaporable getter (NEG) which is used as a hydrogen reservoir for the switch. Therefore we verified the characteristics of the NEG (St 172, Saes) and its installation in the switch. Finally we controlled the getter to find best pressure point for the pseudospark switch.

  • PDF

The research for the triggered vacuum switch which made of a copper electrode

  • Park, Ung-Hwa;Kim, Mu-Sang;Lee, Byeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.144.1-144.1
    • /
    • 2015
  • The triggered vacuum switch(TVS) is a one of the important component in consisiting high power control systems(HPCS). The operating condition is depended on material, geometry, operating power and so on. Our research is focused on the effects of thses basic properties and ptimized condition, because these are critical conditons in understanding the TVS operation. Our experiment is accomplished with a copper electrode and a tungsten trigger pin after being assembled into a vacuum chamber. The operating voltage in our system is more than dozens of kV at the 5kV trigger pulse. Our goal is up to 300kJ, therefore the currents should be more optimized in additional experiments,

  • PDF

Characteristic Tests of High Voltage High Current TVS(Triggered Vacuum Switch) (고전압 대전류용 TVS(Triggered Vacuum Switch) 특성 시험)

  • Park, S.S.;Nam, S.H.;Kim, S.H.;Han, Y.J.;Heo, H.;Kim, S.H.;Park, Y.J.;Hong, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1948-1950
    • /
    • 2004
  • 가속기 연구소에서 개발한 고전압 대전류용 Seal-off TVS (Triggered Vacuum Switch)의 특성을 시험 하는 것을 목적으로 하고 있다. 제작한 TVS는 양전극과 음전극이 교대로 고정된 간격으로 각각 3개의 전극으로 배열되어 있으며 전극은 사다리꼴 모양으로 되어있고 트리거 시스템과 개스를 흡수하는 게터가 내부에 설치되어 있다. 제작한 스위치 내부는 약 $10^{-7}$ torr의 진공상태를 유지하고 있으며 세라믹 챔버를 사용하여 Seal-off 상태로 설계, 제작하였다. 스위치 시험장치는 200 ${\mu}F$, 22 kV 6개를 병렬로 연결한 커패시터 뱅크와 $20{\mu}H{\sim}160{\mu}H$의 탭변환 인덕터와 $0.1{\Omega}{\sim}0.5{\Omega}$ 의 저항을 이용하여 시험 장치를 구성하였다. TVS의 시험에서 에너지 최고 전달량은 74 C 이었으며 이때 인가전압은 30 kV, 최대 전류는 100 kA, 펄스폭은 1${\sim}$2 ms이었다. 본 논문은 제작한 스위치의 전기적인 특성 시험한 결과에 대하여 논하고자 한다.

  • PDF