• Title/Summary/Keyword: Vacuum Plate

Search Result 268, Processing Time 0.029 seconds

Fabrication of Field Emitter Arrays by Transferring Filtered Carbon Nanotubes onto Conducting Substrates

  • Jang, Eun-Soo;Goak, Jung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.311-311
    • /
    • 2009
  • Carbon nanotubes (CNTs) belong to an ideal material for field emitters because of their superior electrical, mechanical, and chemical properties together with unique geometric features. Several applications of CNTs to field emitters have been demonstrated in electron emission devices such as field emission display (FED), backlight unit (BLU), X-ray source, etc. In this study, we fabricated a CNT cathode by using filtration processes. First, an aqueous CNT solution was prepared by ultrasonically dispersing purified single-walled CNTs (SWCNTs) in deionized water with sodium dodecyl sulfate (SDS). The aqueous CNT solution in a milliliter or even several tens of micro-litters was filtered by an alumina membrane through the vacuum filtration, and an ultra-thin CNT film was formed onto the alumina membrane. Thereafter, the alumina membrane was solvated by acetone, and the floating CNT film was easily transferred to indium-tin-oxide (ITO) glass substrate in an area defined as 1 cm with a film mask. The CNT film was subjected to an activation process with an adhesive roller, erecting the CNTs up to serve as electron emitters. In order to measure their luminance characteristics, an ITO-coated glass substrate having phosphor was employed as an anode plate. Our field emitter array (FEA) was fairly transparent unlike conventional FEAs, which enabled light to emit not only through the anode frontside but also through the cathode backside, where luminace on the cathode backside was higher than that on the anode frontside. Futhermore, we added a reflecting metal layer to cathode or anode side to enhance the luminance of light passing through the other side. In one case, the metal layer was formed onto the bottom face of the cathode substrate and reflected the light back so that light passed only through the anode substrate. In the other case, the reflecting layer coated on the anode substrate made all light go only through the cathode substrate. Among the two cases, the latter showed higher luminance than the former. This study will discuss the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the either side.

  • PDF

Effect of Gamma Irradiation on Shelf-life Extension and Sensory Characteristics of Dak-galbi (Marinated Diced Chicken) during Accelerated Storage

  • Yoon, Yo-Han;Cho, Won-Jun;Park, Jin-Gyu;Park, Jae-Nam;Song, Beom-Seok;Kim, Jae-Hun;Byun, Myung-Woo;Kim, Cheon-Jei;Sharma, Arun K.;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.29 no.5
    • /
    • pp.573-578
    • /
    • 2009
  • This study examined the effect of gamma irradiation on shelf-life extension and sensory characteristics of dak-galbi. Commercial dak-galbi sauce was gamma-irradiated at 0, 5, 10, 15, 20, 25, and 30 kGy. The dak-galbi sauce (200 g) was then added to diced chicken (800 g) for cooking, and the cooked dak-galbi samples in vacuum bags were stored at $35^{\circ}C$ for 5 d. Dak-galbi samples were analyzed on d 0, 1, 2, 3, 4, and 5 for microbial analysis (plate count agar), thiobarbituric acid (TBARS) and volatile basic nitrogen (VBN) measurements, and on d 0 for sensory evaluation. On d 0, total bacterial populations were below detection limit after dak-galbi marinated with the gamma-irradiated (${\geq}15\;kGy$) sauces were cooked, and the samples marinated with higher dose irradiated dak-galbi sauce had lower (p<0.05) bacterial populations during storage. TBARS values of the dak-galbi samples marinated with non-irradiated sauce were not different ($p{\geq}0.05$) with those marinated with irradiated sauces on d 0, and the TBARS values increased (p<0.05) during storage at $35^{\circ}C$, regardless of irradiation dose. In the VBN analysis, there was no difference ($p{\geq}0.05$) in VBN values among irradiation doses on d 0, but VBN values decreased (p<0.05) as irradiation dose increased during storage. Moreover, there were no significant differences ($p{\geq}0.05$) in sensory characteristics among irradiation doses. These results indicate that use of gamma irradiation on dak-galbi sauce may be useful in shelf-life extension without compromising the sensory characteristics of dak-galbi.

Development of Slurry Flow Control and Slot Die Optimization Process for Manufacturing Improved Electrodes in Production of Lithium-ion Battery for Electric Vehicles (전기자동차 리튬이온 배터리 제조공정에서 Loading Level 산포최소화 코팅을 통한 전극 품질개선에 관한 연구)

  • Jang, Chan-Hee;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.14-20
    • /
    • 2018
  • Electric vehicles are environmentally friendly because they emit no exhaust gas, unlike gasoline automobiles. However, since they are driven by the electric power from batteries, the distance they can travel based on a single charge depends on their energy density. Therefore, the lithium-ion battery having a high energy density is a good candidate for the batteries of electric vehicles. Since the electrode is an essential component that governs their efficiency, the electrode manufacturing process plays a vital role in the entire production process of lithium-ion batteries. In particular, the coating process is a critical step in the manufacturing of the electrode, which has a significant influence on its performance. In this paper, we propose an innovative process for improving the efficiency and productivity of the coating process in electrode manufacturing and describe the equipment design method and development results. Specifically, we propose a design procedure and development method in order to improve the core plate coating quality by 25%, using a technology capable of reducing the assembly margin due to its high output/high capacity and improving the product capacity quality and assembly process yield. Using this method, the battery life of the lithium-ion battery cell was improved. Compared with the existing coating process, the target loading level is maintained and dispersed to maintain the anode capacity (${\pm}0.4{\rightarrow}{\pm}0.3mg/cm^2r$ reduction).

Heavy Metal Contents of Canned Seafoods Packed in Oil (수산물 기름 담금 통조림 식품의 중금속 함량)

  • Heu, Min-Soo;Kim, Jin-Soo
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.307-314
    • /
    • 2004
  • Specification and heavy metal contents of canned seafoods packed in oil were investigated. 30 species of canned tuna were classified by 4 groups as follow; group (sample codes, 1-10) composed of tuna and oil only, group (11-18) composed of tuna, vegetable and oil, group (19-27) composed of tuna, sauce and oil, and group (28-30) composed of tuna, vegetable, sauce and oil. Commercial canned shellfish packed in oil were mainly produced from sea mussel (sample codes, 31 and 32) and oyster (33-35). Can bodies of canned tuna were made by tin-plate, and used c-enamel or aluminium-paste as coating materials. In pH values of canned tuna, sample codes 1-10 (pH 5.55-5.69) and 19-27 (pH 5.17-5.85) were higher than sample codes 11-18 (pH 4.95-5.43) and 28-30 (pH 5.20-5.38). There was no difference in salinity (1.3-1.9%) and vacuum degree (15-18 mmHg) among canned samples. Heavy metal contents of canned seafoods ranged from 1.04-9.03 ppm for Sn, and 0.17-0.68 ppm for Pb. Those values are below the permitted range (less than 150 ppm for Sn and 2 ppm for Pb).

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Development and Performance Evaluation of Anti-cavitation Paint with a Lamella Glass-flake (판상형 Glass-flake를 이용한 내캐비테이션 도료 개발 및 성능평가)

  • Park, Hyeyoung;Kim, Sung-gil;Kim, Sang-suk;Choi, I-chan;Kim, Byungwoo;Kim, Seung-jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.145-151
    • /
    • 2016
  • In response to the cavitation caused by the partial vacuum caused by the fluid flow, a paint was developed by dispersing the lamella-shaped glass-flake in resin for anti-cavitation. This composite paint was developed by using the inorganic filler (lamella shaped glass-flake) and the NBR (Acrylonitrile-butadiene rubber) which was modified epoxy resin. Especially, the glass-flake was a thin film with a thickness of about 100~200 nm and length of about $20{\sim}30{\mu}m$, the aspect ratio was about 200 to 300 times that of the plate-shaped. So the paint for anti-cavitation have shown excellent performance in corrosion resistance. The results of evaluating anti-cavitation performance was below, tensile strength $4.8{\sim}6N/mm^2$ or more, rupture elongation 30% or higher, abrasive speed $10mm^2/h$ or less. In particular, it showed more than twice the superior performance compared to existing advanced foreign products in anti-cavitation performance evaluation.

Evaluation of the Addition of Sodium Lactate and a Fat Replacer in Very Low-fat Bologna (model system) on the Product Quality and Shelf-life Effect during Refrigerated Storage (젖산나트륨과 지방대체제의 첨가가 냉장저장 중 저지방 볼로나 소시지의 품질 및 저장성에 미치는 영향)

  • 진구복;최순희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.858-864
    • /
    • 2001
  • This study was performed to investigate the effect of sodium lactate (SL, 60%) and a mixed fat replacer (FR) on the product quality and shelf-life effect of low-fat bologna sausage (LFBS) in a model system during refrigerated storage. Low-fat and regular-fat bologna sausages had pH values ranged from 6.15 to 6.30 and water activity values ranged from 0.95 to 0.96. LFBS had a moisture content of 74~76%, <2% fat and 14~15% protein, whereas regular-fat bologna had 60% moisture, 22% fat and approximately 12% protein in the final products. Expressible moisture (%) increased (p<0.05) in all bolognas, resulting in the soft texture, as the storage time (weeks) increased. LFBS manufactured with SL and a FR had lower (p<0.05) the cooking loss (%) and had higher (p<0.05) texture profile analysis (TPA) values than the regular-fat counterpart. As the sodium lactate level increased up to 5% in the formulation of LFBS, vacuum purge and TPA hardness values also increased (p<0.05), but thiobarbituric acid (TBA) values decreased (p<0.05). Total plate counts of LFBS were reduced (p<0.05) when the addition level of 60% SL solution was more than 3.3%. This result indicated that the increased level of SL (>3.3%) in the combination of a FR in the formulation of LFBS improved the product quality and did inhibit the total microbial growth of LFBS during storage, as compared to the control.

  • PDF

Investigation on Resistance to Hydrogen Embrittlement of High Nitrogen Austenitic Steels for Hydrogen Pipe by the Disc Pressure Test and the Tensile Test on Hydrogen Pre-charged Specimens (디스크 시험 및 수소처리 인장시험에 의한 수소배관용 고질소 스테인리스강의 내수소취성 평가 연구)

  • Dong-won, Shin;Min-kyung, Lee;Jeong Hwan, Kim;Ho-seong, Seo;Jae-hun, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.16-23
    • /
    • 2022
  • In this study, characteristics of effect on hydrogen gas was investigated to hydrogen embrittlement by disk and tensile tests. The developed and commercial alloy was fabricated to a plate material made from an alloy ingot. The prepared materials were processed in the form of a disk to measure rupture pressure by hydrogen and helium gas at a rate of 0.1 to 1,000 bar/min. In the hydrogen pre-charged tensile test, a specimen was hydrogenated using an anode charging method, and the yield strength, ultimate tensile strength, elongation, and reduction in area rate were carried by a strain rate test. Also, the microstructure was observed to the fracture surface of the tensile test specimen. As a result, the developed materials satisfied endurable hydrogen embrittlement, and the fractured surface showed a brittleness fracture surface with a depth of several ㎛, but dimple due to ductile fracture could be observed.

Quality and Shelf-Life of Vacuum Packed RTE (Ready-To-Eat) Hamburg Steak Depending on the Oxygen Permeability of Packaging Material and the Storage Temperature (포장재의 산소투과도와 저장온도에 따른 즉석섭취형 햄버그스테이크의 품질 및 저장성)

  • Lim, Ji Hoon;Lee, Sung Ki;Chung, Seung Hee;Lee, Keun Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.95-102
    • /
    • 2016
  • This study investigated the effects of the oxygen permeability of vacuum packaging film and the storage temperature on the quality and shelf life of Hamburg steaks during storage for 14 days. Control samples (C) were packaged in a polyamide/polyethylene (PA/PE) film and stored at $5^{\circ}C$. Treatment samples were either packaged in an ethylene vinyl alcohol/polyethylene (EVOH/PE) copolymer film and stored at $5^{\circ}C$ (T1), and in a PA/PE film and stored at $-18^{\circ}C$ (T2). The initial total plate count (TPC) was 3.6 log cfu/g. In T1 samples, TPC and Brochothrix thermosphacta counts were increased, similar to those in C samples, whereas Pseudomonas spp. counts were significantly lower than those in C samples during storage. Over the storage period, the volatile basic nitrogen values increased most rapidly in C samples, followed by T1 and then T2 samples. The values of thiobarbituric acid reactive substances steadily increased in all samples during storage. The colour parameters were not significantly different among the samples during storage. T1 samples maintained sensory qualities in flavour and off-odour parameters for two days longer than C samples did. At day 12, T2 samples were evaluated as being below the marketability score of 5.0 for texture. In conclusion, using high oxygen barrier films like EVOH/PE copolymer for packaging Hamburg steaks could extend the sensory qualities in view of flavour and off-odour during chilled storage. However, frozen storage at $-18^{\circ}C$ is recommended when the storage period is extended beyond 14 days at $5^{\circ}C$.