• Title/Summary/Keyword: Vacuum Level

Search Result 718, Processing Time 0.032 seconds

Development of VCB Driving Mechanism using Permanent Magnetic Actuator (자기 액츄에이터를 이용한 진공차단기 구동 메카니즘 개발)

  • 최명준;석복렬;김창욱;최영찬;박일한
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.381-389
    • /
    • 2003
  • Nowadays, Vacuum Circuit Breaker(VCB) is used in the most medium voltage level because vacuum has environment-friendly characteristics as well as excellent dielectric strength. In order to elevate the breaking performance, the improvement of vacuum interrupters and the driving mechanism should be proceeded. In this paper, the development of a Permanent Magnet Actuator could replace the mechanical spring mechanism which is the driving mechanism of existing VCB. The holding force and opening characteristics of magnetic actuator are analysed with FEM and the result is verified through experiment.

Effects of Packaging Methods on the Meat Quality of ${\alpha}$-Tocopherol Supplemented Broiler Chicks during Refrigerated Storage

  • Ryu, Youn-Chul;Rhee, Min-Suk;Lee, Moo-Ha;Lee, Sung-Ki;Kim, Byoung-Chul
    • Food Science and Biotechnology
    • /
    • v.15 no.2
    • /
    • pp.248-253
    • /
    • 2006
  • This study examined the effects of vacuum packaging and modified atmosphere packaging (MAP) on the meat quality of ${\alpha}$-tocopherol supplemented broiler chicks after prolonged refrigeration. The supplemented ${\alpha}$-tocopherol levels had no effect on the body weight and feed efficiency. The dietary treatments and packaging methods had no significant effects on the level of microbial growth, lightness, and the metmyoglobin content. The vacuum packaging showed the highest level of purge loss. The broilers supplemented with either 200 or 400 IU of ${\alpha}$-tocopherol had a lower level of malondialdehyde than the control group. The vacuum packaged meats from chicks fed the control diet showed the highest levels of lipid oxidation. The lipid oxidative stability was most improved in modified atmosphere (20% $CO_2$ + 80% $N_2$) packaged breast meat from the broilers supplemented with either 200 or 400 IU of ${\alpha}$-tocopheryl acetate.

Study of Energy Level Alignment at the Interface of P3HT and PCBM Bilayer Deposited by Electrospray Vacuum Deposition

  • Kim, Ji-Hoon;Hong, Jong-Am;Seo, Jae-Won;Kwon, Dae-Gyoen;Park, Yong-Sup
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.134-134
    • /
    • 2012
  • We investigated the interface of poly (3-hexylthiophene) (P3HT) and C61-butyric acid methylester (PCBM) by using photoelectron spectroscopy (PES). These are the most widely used materials for bulk heterojunction (BHJ) organic solar cells due to their high efficiency. Study of the BHJ interfaces is difficult because the organic films are typically prepared by spin coating in ambient conditions. This is incompatible with the interface electronic structure probes such as PES, which requires ultrahigh vacuum conditions. Study of interface requires gradual deposition of thin films that is also incompatible with the spin coating process. In this work, we used electrospray vacuum deposition (EVD) technique to deposit P3HT and PCBM in high vacuum conditions. EVD allows us to form polymer thin films onto ITO substrate in a step-wise manner directly from solutions and to use PES without exposing the sample to the ambient condition. Although the morphology of the EVD deposited P3HT films observed by optical and atomic force microscopes is quite different from that of the spin coated ones, the valence region spectra were similar. PCBM was deposited on the P3HT film in a similar manner and the energy level alignment between these two materials was studied. We discuss the relation between Voc of P3HT:PCBM solar cell and HOMO-LUMO energy offset obtained in this study.

  • PDF

The Sound Quality Evaluation and preference Analysis of Vacuum Cleaner (진공 청소기의 음질 평가 및 선호도 분석)

  • Jung, Dong-Hyun;Park, Sang-Gil;Fawazi, Noor;Lee, You-Yub;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The Conventional noise control attempts to simply reduce the level of product noise. But it is very straight forward way that we have consider human perception on noise. Since human listening is very sensitive to sound. Evaluation of the sound quality of a Vacuum Cleaner is studied base on human sensibility engineering. In this paper, we choose two Vacuum Cleaners that are sold in Korea and reduced noise control. Comparison Method is used to evaluate noise and preference of Vacuum Cleaner by steps. The sound quality of Vacuum Cleaner noise is analyzed by employing the subjective evaluation and by representing them in terms of the objective quantities. Semantic Differential Method is used to study sound quality Evaluation. To analyze the sound quality of Vacuum Cleaner noise, consider the coefficients of correlation between sound metrics and subjective rating. The linear regression models were obtained for the subjective evaluation and sound quality metrics.

  • PDF

Consideration on the helium leak detection in a large vacuum chamber (대형 진공용기의 헬륨 누설검사 방법에 대한 고찰)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.235-243
    • /
    • 2007
  • Nowadays, in our country, large vacuum chambers for huge experimental facilities such as the tokamak fusion device, high power neural beam test stand, and space simulator have been constructed. In such a vacuum chamber of very large size, it is quite complicate to check on leakage quantitatively, while the probability of a leak is relatively high. To investigate the feasibility of applying reliably a helium leak detection to the huge vacuum chambers, and to find a reasonable methodology of choosing an optimum set-up for leak detection, several virtual constructions of the leak detection system have been analyzed by calculating the pressure distribution in the system and the helium level in the sensor part.

Development and Verification of Thermal Analysis Model for Thermal Vacuum Test of Satellite Components (인공위성 탑재품 수준 열진공 시험에 대한 열해석 모델의 개발과 환경시험 결과를 이용한 검증)

  • Kim, Sang-Ho;Seo, Hyun-Suk;You, Jae-Ho;Han, Eun-Soo;Kim, Tai-Kyung;Kim, Hyeong-Dong;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.8
    • /
    • pp.842-847
    • /
    • 2010
  • Thermal analysis for the simulation of satellite component level thermal vacuum test processes was carried out by considering thermal vacuum test environment condition, thermal vacuum chamber configuration, and satellite's inner thermal environment. The transient analysis results can be obtained for the temperatures of component and thermal vacuum chamber assemblies. The thermal analysis model was verified with the component thermal environmental test results by using enhanced thermal vacuum chamber.

Soft X-ray Spectroscopy of ClAlPc/Pentacene/ITO Interfaces: Role of ClAlPc on Energetic Band Alignment

  • Kim, Min-Su;Heo, Na-Ri;Lee, Sang-Ho;Jo, Sang-Wan;Smith, Kevin E.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.190.1-190.1
    • /
    • 2014
  • The interfacial electronic structure of a bilayer of chloroaluminum phthalocyanine (ClAlPc) and pentacene grown on indium tin oxide (ITO) has been studied using synchrotron radiation-excited photoelectron spectroscopy. The energy difference between the highest occupied molecular orbital (HOMO) level of the pentacene layer and the lowest unoccupied molecular orbital (LUMO) level of the ClAlPc layer (EDHOMO - EALUMO) was determined and compared with that of C60/pentacene bilayers. The EDHOMO - EALUMO of a heterojunction with ClAlPc was found to be 1.4 eV, while that with C60 was 1.0 eV. This difference is discussed in terms of the difference of the ionization energy of each acceptor materials. We also obtained the complete energy level diagrams of ClAlPc/pentacene/ITO and C60/pentacene/ITO, respectively.

  • PDF

XPS Analysis of $Cd_{1-x}Co_xIn_2Se_4$ Crystals ($Cd_{1-x}Co_xIn_2Se_4$ 결정의 XPS 분석)

  • 최성휴
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.3
    • /
    • pp.355-359
    • /
    • 1994
  • Cd1-xCoxIn2Se4(X=0.50) 결정을 수직 Bridgman 방법으로 성장시키고 성장된 결정의 결정구조 및 XPS 특성을 연구하였다. 성장된 결정은 pseudocubic 구조이고 격자상수는 a=5.778$\AA$으로 주어졌다. Cd1-xCoxIn2Se4 결정의 각 성분원소인 cadmium cobalt indium 그리고 selenium에 대한 XPS spectrum으 로부터 결합에너지와 결합상태를 조사하였다. Cd1-xCoxIn2Se4결정과 결합하지 안는 각 성분원소인 cadium cobalt imdium 그리고 selenium에 대한 core level의 XPS spectrum과 비교하면 각 성분원소상 이의 결합에 의한 chemical shift 현상 때문에 core level의 결합에너지가 0.10~4.87 eV 차이가 있다. Cd1-xCoxIn2Se4 결정에서 Co 2P3/2 core level의 주 peak와 statellite peak와의 결합에너지 차이로부터 cadmium과 치화된 cobalt는 Co2+ ion으로 Td symmetry 점에 위치함을 알 수 있다.

  • PDF

Inter Landau Level Optical Absorption in Graphene Under Ultra-high Magnetic Field

  • Saito, H.;Nakamura, D.;Takeyama, S.;Kim, Yong-Min;An, K.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.360-360
    • /
    • 2012
  • Graphene shows diverse novel physical properties arising from its peculiar electronic states, so called Dirac electrons. Especially, effect of magnetic field is very unique, exhibiting exotic Landau level (LL) splitting. LLs are substantially modified by spins of Dirac electrons and pseudo-spins. The degeneracy of LLs is lifted to show splitting by electron-electron interaction and by the Zeeman effect. We investigated the magneto-optical absorption of graphene subjected to ultra-high magnetic field. Samples were prepared by the CVD method deposited on GaAs and Quart substrate. We have confirmed existence of graphene on each substrate by the micro-Raman spectroscopy. Next, we conducted magneto-absorption measurements in magnetic field up to 120 T by the single-turn coil (STC) method. We could observe absorption peak at 65 T and 100 T, respectively, probably arising from the LL inter-band transitions.

  • PDF

Mussel-Inspired, Fast Surface Modification of Solid Substrates

  • Hong, Sang-Hyeon;Kang, Sung-Min;Lee, Hae-Shin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.201-201
    • /
    • 2011
  • Recently, mussel-inspired surface modification, called polydopamine coating has been extensively implemented to many areas, due to its material versatility and ease to use. In particular, incubation of substrates in an alkaline dopamine solution resulted in self-polymerization of dopamine and modified variety of material surfaces, including noble metals, metal oxides, ceramics, and synthetic polymers. However, the polydopamine coating has a drawback to practical use; it takes more than 12 hrs to introduce sufficient polydopamine layers to solid substrates. Here, we investigated the rate-enhanced polydopamine coating by varying reaction conditions: pH, concentration, and the addition of the oxidizing agent. As a result, the optimum condition for fast polydopamine coating was found, and solid substrates were efficiently coated with polydopamine layers in just few minutes using the condition. The polydopamine-modified surface was characterized by XPS and contact angle goniometry, and the biocompatibility of the modified surface was also proved by cell attachment test.

  • PDF