• Title/Summary/Keyword: Vacuum Characteristics

Search Result 2,162, Processing Time 0.039 seconds

A Study on the Temperature Distribution Characteristics of NAS Battery Module (NAS 전지 모듈의 온도 분포 특성에 관한 연구)

  • Heo, Doo-Sang;Yi, Chung-Seob;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2012
  • This paper addresses the issue of Renewable Energy for Electricity Storage device is one of the NAS (Sodium-Sulfur) battery will be about the module. For safety reasons, not the actual battery cells using a dummy cell in the module's operating temperature setting to examine the characteristics of the insulation vacuum of the wall temperature and external temperature changes measured over time. Upper and lower boundaries of the wall vacuum insulation characteristics cotton C intervals over time, average $5^{\circ}C$, but the temperature is rising, 4C section with little temperature change did not occur. On the other hand, about $3^{\circ}C$ in section 4D, and it was confirmed that the temperature rises. Wall vacuum insulation characteristics over time to look at the experiments and measurements are described.

The Improvement in Pumping Characteristics of Sputter Ion Pumps in the Ultra High Vacuum(UHV) Region (이온펌프의 초고진공영역에서의 배기특성개선)

  • 김정선;여환욱;박종윤
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.4
    • /
    • pp.401-404
    • /
    • 1994
  • 초고 진공영역에서 배기특성 개선을 위하여 재질 및 구조가 다른 세가지 형태의 60(l/s) 형이온 펌프를 제작하여 그 배기특성을 측정하였다. 그 결과 음극판에 Ta 선을 전기용접한 펌프와 양극 cell의 구조에 변화를 준 펌프의 배기속도가 상용으로 이용되고 있는 펌프에 비해 약 50% 이상 개선되었다.

  • PDF

Electrical and Optical Characteristics of Plasma Display Panel Fabricated by Vacuum In-line Sealing (진공 인라인 실장에 의해 제작된 플라즈마 디스플레이 패널의 전기적ㆍ광학적 특성)

  • Park, Sung-Hyun;Lee, Neung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.344-349
    • /
    • 2005
  • The optical and electrical characteristics of plasma display panel(PDP) using the vacuum in-line sealing technology compared with the conventional sealing process in this research. This PDP consisted of MgO protecting layer by e-beam evaporation and battier rib, transparent dielectric layer, dielectric layer, and electrodes by screen printer and then sealed off on Ne-Xe(4 %) 400 Torr and 430。C. The brightness and luminous efficiency were good as the base vacuum level was higher, and it was to check the advantage of high vacuum level sealing, one of the strong points of the vacuum in-line sealing process. However, the brightness and luminous efficiency was dropped sharply because of a crack on MgO protecting layer by the difference of the expansion and contraction stress on high temperature in the vacuum states between MgO and substrate. Fortunately, the crack was prevented by MgO was deposited on higher temperature than 300。C. Finally, the PDP, was fabricated by the vacuum in-line sealing process, resulted the lower brightness than processing only the thermal annealing treatment in the vacuum chamber, but the luminous efficiency was increased by the reducing power consumption with the decreasing luminous current. The vacuum in-line sealing technology was not to need the additional thermal annealing process and could reduce the fabrication process and bring the excellent optical and electrical properties without the crack of MgO protecting layer than the conventional sealing process.

A Comparison of Energy Loss Characteristics between Radial and Axial Magnetic Field Type Vacuum Switches (대전력 펄스용 횡자계형 및 종자계형 진공스위치의 에너지 손실 특성 비교)

  • 이태호;허창수;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.130-136
    • /
    • 2003
  • Crowbar system Vacuum switches, widely used In a pulsed power system, could use the magnetic force to prevent the electrode damage. Vacuum switches using the magnetic forces are classified roughly into RMF(Radial Magnetic Field) and AMF(Axial Magnetic Field) type. The RMF type switches restrain a main electrode from aging due to high temperature and high density arc by rotating the arc which is driven by the Lorenz force. The AMF type switches generate axial magnetic field which decreases the electrode damage by diffusing arc. In this paper, we present the energy loss characteristics of both RMF and AMF type switches which are made of CuCr(75:25 wt%) electrodes. The time-dependent dynamic arc resistance of high-current pulsed discharge in a high vacuum chamber(~10$^{-6}$ Torr). which occurs in RMF and AMF type switches, was obtained by solving the circuit equation using the measured values of the arc voltage and current. In addition, we compared energy loss characteristics of both switches. Based on our results, it was found that the arc voltage and the energy loss of an AMF type switch are lower than a RMF type switch.

A Study on the Rapid Cooling Vacuum System for the Storage and Transportation of the Cold Agriculture and Livestock Products (농축산물의 저장 및 유통을 위한 감압증발 급냉각 시스템에 관한 연구)

  • 김성규;김원녕;김경석;최순열;전현필
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.26-36
    • /
    • 1997
  • Recently, the new refrigerating system, using non - fluorinated hydrocarbon refrigerants has to be developed for the agricultural fields. One of that kinds of systems is the cooling system using the water vapor and vacuum, in which the water evaporate at the low temperature under vacuum and absorb the large amount of the latent heat. If vapor with large amount of latent heat is removed from the system, the system is cooled accordingly. The characteristics of cooling under the vacuum was observed and measured using experimental apparatus, which is consisted of vacuum chamber, the ejectors, the pumps and the measurement apparatus. As the results of experiments, we know that the evaporation in the vacuum occurs vigorously when the materials to be cooled has more amounts of heat before cooling, and by which effects the materials can be cooled. The cooling vacuum system is more efficient than other methods when the agricultural products is chilled or dried.

  • PDF

Modeling and Control of an Electronic-Vacuum Booster for Vehicle Cruise Control

  • Lee, Chankyu;Kyongsu Yi
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1314-1319
    • /
    • 2002
  • A mathematical model and control laws for an Electronic-Vacuum Booster (EVB) for application to vehicle cruise control will be presented. Also this paper includes performance test result of EVB and vehicle cruise control experiments. The pressure difference between the vacuum chamber and the apply chamber is controlled by a PWM-solenoid-valve. Since the pressure at the vacuum chamber is identical to that of the engine intake manifold, the output of the electronic-vacuum booster Is sensitive to engine speed. The performance characteristics of the electronic-vacuum booster have been investigated via computer simulations and vehicle tests. The mathematical model of the electronic-vacuum booster developed in this study and a two-state dynamic engine model have been used in the simulations. It has been shown by simulations and vehicle tests that the EVB-cruise control system can provide a vehicle with good distance control performance in both high speed and low speed stop and go driving situations.

Pre-Flashover of Alumina in Vacuum (진공중에서 알루미나의 플래쉬오버 현상)

  • Jung, You-Ra;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.266-267
    • /
    • 2008
  • The flashover of insulators in vacuum is the main factor to limit the performance of insulation in vacuum insulation system. It is believed that the pre-flashover phenomena would play a very important role in the procedure of the flashover in the interface between the insulators and vacuum. This paper is mainly concerned on the pre-flashover phenomena of Alumina insulators in vacuum. There are 24 different types of alumina insulators were tested with a 0.7/4 ${\mu}s$ pulsed voltage under a $1\times10^{-4}Pa$ vacuum. The observed pre-flashover phenomena were classified and the pre-flashover characteristics were concluded. It is useful to study further on the flashover mechanism in vacuum.

  • PDF

Pre-Flashover of Alumina in Vacuum (진공 중에서 알루미나의 플래쉬오버)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.375-376
    • /
    • 2008
  • The flashover of insulators in vacuum is the main factor to limit the performance of insulation in vacuum insulation system. It is believed that the pre-flashover phenomena would play a very important role in the procedure of the flashover in the interface between the insulators and vacuum. This paper is mainly concerned on the pre-flashover phenomena of Alumina insulators in vacuum. There are 24 different types of alumina insulators were tested with a 0.7/4 ${\mu}s$ pulsed voltage under a $1\times10^{-4}$Pa vacuum. The observed pre-flashover phenomena were classified and the pre-flashover characteristics were concluded. It is useful to study further on the flashover mechanism in vacuum.

  • PDF

The evaluation of Sound Power Level and development of index for Sound Quality of Vacuum Cleaner according to performances of Sound Absorbtion Materials (흡음재 성능에 따른 진공청소기의 음향파워 평가 및 음질인덱스 개발)

  • Kwon, Hyuk-Je;Lee, Sang-Kwon;Gu, Jin-Hoi;Lee, Hyun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.112-120
    • /
    • 2008
  • Today, the use of a vacuum cleaner gave us the higher quality of life than past time, but sometimes made us w1comfortable in the house because of the specific noise that is annoying. So we need to study how sound absorbtion materials affect sound power level and sound quality with sound metrics. In this paper, we will measure and calculate sound power level for vacuum cleaner and analyze characteristics of the noise for 10 Signals according to materials positioned in vacuum cleaner. The multiple regression analysis can estimate the nonlinear characteristics of relation between subjective evaluation and sound metrics. So we will develop sound quality index for vacuum sound.

  • PDF