• Title/Summary/Keyword: VX2 암종

Search Result 5, Processing Time 0.017 seconds

The Comparative Imaging Study on Mn-phthalocyanine and Mangafodipir trisodium in Experimental VX2 Animal Model (실험적으로 유발시킨 VX2 동물모델에서의 Mn-phthalocyanine과 Mangafodipir trisodium의 비교영상)

  • Park Hyun-Jeong;Ko Sung-Min;Kim Yong-Sun;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.32-41
    • /
    • 2004
  • Purpose : To measure the NMR relaxation properties of MnPC, to observe the characteristics of liver enhancement patterns on MR images in experimentally implanted rabbit VX2 tumor model, and to estimate the possibility of tissue specific contrast agent for MnPC in comparison with the hepatobiliary agent. Materials and Methods : Phthalocyanine (PC) was chelated with paramagnetic ions, manganese (Mn). 2.01 g (5.2 mmol) of phthalocyanine was mixed with 0.37 g (1.4 nlmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography ($CHCl_3:\;CH_3OH=98:2$, volume ratio) to obtain 1.04 g $(46\%)$ of MnPC (molecular weight = 2000 daltons). The T1/T2 relaxivity (R1/R2) for MnPC were determined at a 1.5 T (64 MHz) MR spectrometer. VX2 tumor model was experimentally implanted in the liver parenchyma of rabbits. All MR studies were performed on 1.5 T. The human extremity radio frequency coil of a bird cage type was employed. MR images were acquired at 17 to 24 days after VX2 carcinoma implantation.4 mmol/kg MnPC and 0.01 mmol/kg Mn-DPDP were injected via the ear vein of rabbits. T1-weighted images were obtained with spin-echo (TR/TE=516/14 msec) and fast multiplanar spoiled gradient recalled (TR/TE : 80/4 msec, $60^{\circ}$ flip angle) pulse sequence. Fast spin-echo (TR/TE=1200/85 msec) was used to obtain the T2-weighted images. Results : The value of T1/T2 relaxivity (R1/R2) of MnPC was $7.28\;mM^{-1}S^{-1}$ and $55.56\;mM^{-1}S^{-1}$ respectively at 1.5 T (64 MHz). Because the T2 relaxivity of MnPC that bonded strongly, covalently manganese with phthalocyanine was very high, the signal intensity of liver parenchyma was decreased on postcontrast T2-weighted images and we could easily distinguish the VX2 carcinoma within the liver parenchyma. When MnPC was administrated intravenously, the tumor margin delineation was more remarkable than Mn-DPDP-enhanced images. The enhancement of liver parenchyma with MnPC persisted at relatively high levels over at least one hour after injection of the contrast agents. Conclusion : The hepatic uptake and biliary excretion of MnPC, which are similar to Mn-DPDP, suggest that this agent is a new liver-specific agent. Also, MnPC seems to be used as a dual contrast agent (T1 and T2) with high T2 relaxivity. However, it is warranted that MnPC needs further investigation as a potential contrast agent for MR imaging of the liver. That is, further characterizations of MnPC are needed in vivo and in vitro before clinical trials. The diagnostic potential of MnPC will also have to be examined more in the animal models of additional types.

  • PDF

Solitary Hepatic VX2 Tumor Model and Its CT Findings in Rabbits (가토에서 VX2 단일간암모델과 CT 소견)

  • Lee, Hae-Beom;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.388-392
    • /
    • 2006
  • To verify the solitary nodular hepatocellular tumor model induced by intraparenchymal VX2 tumor cell injection and assess the diagnostic imaging character by computed tomography in rabbits. The tumor cell fragment ($1{\sim}2mm^3$) was loaded in Seldinger needle and directly implanted into the livers of 80 New Zealand white rabbits. The tumor size and patterns of tumor growth were evaluated using spiral computed tomography (CT) at 1, 2, and 3 weeks after tumor implantation. A solitary nodular tumor was successfully created in 82.5% (66/80). The mortality rate was 5% (4/80). The tumor sizes measured were 7.46.3, 14.210.8, 16.212.6 cm at 1, 2, and 3 weeks after tumor implantation on arterial phase CT images. The tumors were round to oval shape with peripheral enhancement and central hypoattenuation on arterial phase, and hypoatteuated wash-out pattern on portal phase. It is considered that inoculation of tumor fragment loaded in Seldinger needle is useful and practical method for creating a solitary hepatic tumor. And CT scanning are valuable to investigate the hepatic tumor and compatible to the observations on macro-and microscopic findings.

Polycarprolacton으로 표면 수식된 나노 산화철 조영제의 합성에 관한 연구

  • 박동규;박지애;장용민;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.35-35
    • /
    • 2003
  • 목적: 나노 산화철 입자 및 생고분자인 PCL(Polycarprolacton)로 표면 코팅한 T2 MR 조영제를 합성하고 동물 종양 모델을 이용하여 In vivo 특성을 조사하고자 하였다. 대상 및 방법: $FeC1_2$.$4H_2$O와 $FeC1_3$.$6H_2$O을 무게비를 1:2로 정량하여 첨가하고 NaOH 혹은 TMAOH로 pH를 조절한후 PCL를 첨가하여 magnetite가 생성되는 동시에 고분자로서 코팅을 한후 증류수로 여러번 씻어준다. TEM, SEM, DLS 및 IR spectroscopy와 SQUID등을 측정하여 최종 반응물의 입자크기, 자성, 코팅 상태등을 평가하였다. 최소의 입자크기를 형성하는데 필요한 실험 조건을 찾기 위해 반응온도, 코팅할 고분자의 함량, 교반속도별로 실험하여서 최적의 조건을 찾으려 하였다. 토끼의 간에 VX2 암종을 이식한 동물 모델을 이용하여 PCL로 표면 코팅된 나노자성체의 in vivo 영상 특성을 알아보았다.

  • PDF

Research on Perfusion CT in Rabbit Brain Tumor Model (토끼 뇌종양 모델에서의 관류 CT 영상에 관한 연구)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung;Lim, Cheong-Hwan;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.165-172
    • /
    • 2012
  • We investigated the vascular characteristics of tumors and normal tissue using perfusion CT in the rabbit brain tumor model. The VX2 carcinoma concentration of $1{\times}10^7$ cells/ml(0.1ml) was implanted in the brain of nine New Zealand white rabbits (weight: 2.4kg-3.0kg, mean: 2.6kg). The perfusion CT was scanned when the tumors were grown up to 5mm. The tumor volume and perfusion value were quantitatively analyzed by using commercial workstation (advantage windows workstation, AW, version 4.2, GE, USA). The mean volume of implanted tumors was $316{\pm}181mm^3$, and the biggest and smallest volumes of tumor were 497 $mm^3$ and 195 $mm^3$, respectively. All the implanted tumors in rabbits are single-nodular tumors, and intracranial metastasis was not observed. In the perfusion CT, cerebral blood volume (CBV) were $74.40{\pm}9.63$, $16.08{\pm}0.64$, $15.24{\pm}3.23$ ml/100g in the tumor core, ipsilateral normal brain, and contralateral normal brain, respectively ($p{\leqq}0.05$). In the cerebral blood flow (CBF), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($962.91{\pm}75.96$ vs. $357.82{\pm}12.82$ vs. $323.19{\pm}83.24$ ml/100g/min). In the mean transit time (MTT), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($4.37{\pm}0.19$ vs. $3.02{\pm}0.41$ vs. $2.86{\pm}0.22$ sec). In the permeability surface (PS), there were significant differences among the tumor core, ipsilateral and contralateral normal brains ($47.23{\pm}25.45$ vs. $14.54{\pm}1.60$ vs. $6.81{\pm}4.20$ ml/100g/min)($p{\leqq}0.05$). In the time to peak (TTP) were no significant differences among the tumor core, ipsilateral and contralateral normal brains. In the positive enhancement integral (PEI), there were significant differences among the tumor core, ipsilateral and contralateral brains ($61.56{\pm}16.07$ vs. $12.58{\pm}2.61$ vs. $8.26{\pm}5.55$ ml/100g). ($p{\leqq}0.05$). In the maximum slope of increase (MSI), there were significant differences between the tumor core and both normal brain($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($13.18{\pm}2.81$ vs. $6.99{\pm}1.73$ vs. $6.41{\pm}1.39$ HU/sec). Additionally, in the maximum slope of decrease (MSD), there were significant differences between the tumor core and contralateral normal brain($p{\leqq}0.05$), but no significant differences between the tumor core and ipsilateral normal brain($4.02{\pm}1.37$ vs. $4.66{\pm}0.83$ vs. $6.47{\pm}1.53$ HU/sec). In conclusion, the VX2 tumors were implanted in the rabbit brain successfully, and stereotactic inoculation method make single-nodular type of tumor that was no metastasis in intracranial, suitable for comparative study between tumors and normal tissues. Therefore, perfusion CT would be a useful diagnostic tool capable of reflecting the vascularity of the tumors.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF