• Title/Summary/Keyword: VP4

Search Result 489, Processing Time 0.023 seconds

Analysis of Fashion Window Display at Printemps Department Store in Paris, France - Focused on the period from 2009 to 2014 - (프랑스 파리 쁘랭땅 백화점 패션윈도우 디스플레이 분석 - 2009년부터 2014년 기간을 중심으로 -)

  • Heo, Seungyeun;Kim, Chil Soon;Kim, Sunha
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.501-512
    • /
    • 2015
  • This study was to consider and analyze of fashion window display design at Printemps department store in Paris, France which has tried continuously space presentations through the sensibility and differentiated strategy. The framework for analysis of this study was established by related precedent studies. Data collection was done by searching related specialty publications and website of Printemps department store, and the results of this study were drawn through qualitative analysis of experts' group. The results are as follows. Printemps department store set up presentation types of fashion window display design's themes that have been developed by the method of display presentation such as symbolic, ambience, surrealistic, realistic, and information. The most frequently used presentation development techniques applied in windows' VP of Printemps were the 'transferal of daily space', 'transferal of unexpected space', 'exaggeration of animal & plant', and 'descriptive narrative scene.' In addition, the display theme components such as the materials that can be easily accessible in everyday life, unique directing props, the memory or childhood, the image of animal or plant, and lighting etc. We found that the major colors of window display design at Printemps department store were purple, blue and black during the period from 2009 to 2014.

A Method of Enhancing Security of Internet Banking Service using Contents-Based CAPTCHA (콘텐츠 기반 캡차를 이용한 인터넷 뱅킹 서비스의 보안성 향상 기법)

  • Lee, Sang-Ho;Kim, Sung-Ho;Kang, Jeon-Il;Byun, Je-Sung;Nyang, Dea-Hun;Lee, Kyung-Hee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.4
    • /
    • pp.571-583
    • /
    • 2013
  • Internet banking service has a advantage that is unrestricted by time. If automated programs are able to attack Internet banking services, a number of accounts can be attacked at the same time and as a result, damage will be considerably increased. To cope with such attacks, two methods, VPS and MS watermark, were introduced by Arcot and MS respectively. The methods use text-based CAPTCHAs in the process of transfer approval to distinguish automated programs from legal human users. In this paper, we point out the security threats of the methods when those are applied to Internet banking services. Especially, we consider the attack that are performed by extract specific string from text-based CAPTCHAs and it's countermeasure. Also we suggest a method of enhancing security of internet banking services. Our method is based on contents-based CAPTCHAs that are consist of known transfer information between user and server.

The Lowest Dose for CT Attenuation Correction in PET/CT

  • Kang, Byung-Sam;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.111-115
    • /
    • 2011
  • PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

  • PDF

Secondary Grammaticalization and English Adverbial Tense (이차적 문법화와 영어부사의 시제)

  • Kim, Yangsoon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.115-121
    • /
    • 2020
  • The primary aim of this paper is to discuss the historical development or grammaticalization of English adverbial -ly suffix and provide a diachronic analysis of manner adverbs and sentence adverbs from the perspective of secondary grammaticalization. The grammaticalization includes both the primary grammaticalization from a lexical to a grammatical and the secondary grammaticalization from a less grammatical to a more grammatical status. The emergence of the manner adverbs is due to the primary grammaticalization from OE adjectival suffix -lic to ME adverbial suffix -ly. In contrast, the emergence of sentence adverbs is due to the secondary grammaticalization from manner adverbs in VP domain to sentence adverbs in TP domain with grammatical features of tense and modality. This paper concludes that the secondary grammaticalization of the English adverbial -ly suffix includes the change from manner adverbs to sentence adverbs which obtain a new grammatical function of tense and modality.

The Broad-beam CT Image Reconstruction from Simulator Images (모의치료(Simulation) 영상을 이용한 Broad-beam CT 영상 구현)

  • Yi, Byong-Yong
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.81-86
    • /
    • 1998
  • Purpose : To generate the axial, coronal and sagittal images from conventional simulation images, as a preliminary study of broad-beam simulator CT. Methods and Materials : Volumetric filtered back-projection was performed using 90 sheets of films from conventional simulator for every $4^{\circ}$ gantry angle. Two mAs exposure condition for 120kvp beam qualify at SFD 140cm was given to each film. Outside the silhouette portion was removed and scatter component was deconvolved before back-projection. Results : The axial, the sagittal and the coronal images with same spatial resolutions over all direction could be obtained. But image quality was very poor. Conclusion : CT images could be obtained using broad-beam. Scatter deconvolution technique was effective for this reconstruction. The fact that same spatial resolutions over all direction tells us the possibility of application of this technique to DRR or Simulator-CT. But the quality of image should be improved for clinical application practically.

  • PDF

Characterization of the molecular and biological properties between the equine herpesvirus type 1 immediate-early protein and the general transcription factor human TFIIB

  • Jang Hyung-Kwan
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.4
    • /
    • pp.355-369
    • /
    • 2004
  • The equine herpesvirus type 1 (EHV-1) immediate-early (IE) protein is a potent transactivator responsible for the activation of both early and late genes during the course of infection and is comprised of discrete functional domains that mediate its many functions. Interaction between trans activators such as the IE protein and various components of the RNA polymerase II transcription initiation machinery has been demonstrated to be critical for transactivation. In the present report, it is addressed the hypothesis that the IE protein interacts with various components of transcription machinery to mediate transactivation of target viral genes. In these studies, it is demonstrated that in vitro transcribed and translated IE protein interacts with TFIIB-agarose conjugate but not with TFIID-agarose conjugate. Additional immunoprecipitation studies using nuclear extracts derived from EHV-1 infected RK-13 cells confirmed that the IE protein interacts strongly with TFIIB, but fails to interact with TFIID. IR2, a truncated form of the IE protein lacking the potent transactivation domain and involved in the down-regulation of the IE gene, also interacted with TFIIB but not with TFIID. Studies were also performed to ascertain if particular TBP-associated factors (TAFs) could mediate IE or IR2 binding to TFIID. In vitro transcribed and translated TAF250 added to nuclear extracts generated from EHV-1 infected cells also failed to mediate an interaction between the IE protein or the IR2 protein and TFIID. This study demonstrated that the IE protein mediates transactivation of target viral genes by a mechanism that involves TFIIB. This is in contrast to mechanisms that have been proposed for both the herpes simplex virus ICP4 and VP16 protein which have been proposed to transactivate viral genes through interactions involving both TFIIB and TFIID. This study also intimates that IR2 mediate its repressive effects during the course of EHV-1 infection by a mechanism that involves sequestration of various transcription factors.

Evaluation of Punching Shear Safety of a Two-Way Void Plywood Slab System with Form (거푸집 패널이 부착된 2방향 중공슬래브의 뚫림 전단 안전성 평가)

  • Hur, Moo-Won;Woo, Hyung-Sik;Park, Jung-Min;Kang, Hyun-Wook;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.182-189
    • /
    • 2021
  • VPS(Void Plywood Slab System, VPS) has optimized the shape of the hollow material. In addition, it has a function to prevent the floating of the hollow material and the separation due to the working load. In this study, the punching shear capacity of flat plate was performed using Void Plywood Slab System with form work panel proposed in the previous study. As a result of the test, the strength of the VSPS specimen in which the hollow material was placed beyond 2.0 times the column width from the loading point was reduced by 9.4% compared to the reference specimen. However, the strength value was about 1.57 times higher than the design value suggested by KBC 2016. It was found that there was no change in stiffness compared to the reference specimen until shear failure occurred in the VSPS specimen in which the hollow material was placed. It can be seen that this experiment is being destroyed by shear as the flexural reinforcing bars are sufficiently reinforced.

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

Radiation Resistance Evaluation of Thin Film Transistors (박막트랜지스터의 방사선 내구성 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 2023
  • The important requirement of industrial dynamic X-ray detector operating under high tube voltage up to 450 kVp for 24 hours and 7 days is to obtain significantly high radiation resistance. This study presents the radiation resistance characteristics of various thin film transistors (TFTs) with a-Si, poly-Si and IGZO semiconducting layers. IGZO TFT offering dozens of times higher field effect mobility than a-Si TFT was processed with highly hydrogenated plasma in between IGZO semiconducting layer and inter-layered dielectric. The hydrogenated IGZO TFT showed most sustainable radiation resistance up to 10,000Gy accumulated, thus, concluded that it is a sole switching device in X-ray imaging sensor offering dynamic X-ray imaging at high frame rate under extremely severe radiation environment such as automated X-ray inspection.

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.