• Title/Summary/Keyword: VP2

Search Result 638, Processing Time 0.041 seconds

The Research of Comparison Evaluation on the Decline in Artifact Using Respiratory Gating System in PET-CT (PET-CT 검사 시 호흡동조 시스템을 이용한 인공물 감소에 대한 비교 평가)

  • Kim, Jin-Young;Lee, Seung Jae;jung, Suk;Park, Min-Soo;Kang, Chun-Goo;Im, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.63-67
    • /
    • 2015
  • Purpose Among various causes that influence image quality degradation, various methods for decrease in Artifact occurred by respiration of patients are being used. Among them, this study intended to evaluate CTAC Shift correction method and additional scan compare to the Scan(Q static scan) using respiratory gated system. Materials and Methods This study was conducted on 10 patients, and used PET-CT Discovery 710 (GE Healthcare, MI, USA) and Varian's RPM system. 5.18 Mbq per kg of $^{18}F$-FDG was injected on patients, asked them to take a rest for 1 hour in the bed, and conducted test after urination. Images were visualized through Q static scan, CTAC Shift correction method, Additional scan based on the Whole body scan(WBS) with Artifact. Decrease in Artifact was compared in each image, conducted Gross Evalution, and measured changes of SUVmax. Results For image obtained through the CTAC Shift correction method through WBS with Artifact, 12~56%, Q static scan image showed 17~54% of change rate and Additional Scan showed -27~46% of change rate. In Blind Test, the CTAC Shift correction image showed the highest point with 4 points, Q static scan image showed 3.5 points, and Additional scan image showed 3.4 points. The standardized WBS scan through Oneway ANOVA and three types of Scan method showed significant difference(p<0.05), and did not show significant difference between the three Scan methods(p>0.05). However, the three Scan methods showed significant difference in Blind test. Conclusion Additional scan and Q static scan require more time than the CTAC Shift correction method, there is concern about excessive exposure to patients by CT rescan and Q static scan is difficult to apply on patients with inconsistent respiration or irregular respiration cycle due to pain. For CTAC Shift correction method, limited correction is possible and the range is limited as well. It is considered as a useful method of improving diagnostic value when hospitals use the system appropriately and develop various advantageous factors of each method.

  • PDF

Analysis of the Imaging Dose for IGRT/Gated Treatments (영상유도 및 호흡동조 방사선치료에서의 영상장비에 의한 흡수선량 분석)

  • Shin, Jung-Suk;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Hong, Chae-Seon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.42-48
    • /
    • 2009
  • Purpose: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. Materials and Methods: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. Results: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold ($1.74{\pm}0.34$ cGy versus $23.23{\pm}3.67$cGy). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were $0.91{\pm}0.89$ cGy versus $6.77{\pm}3.56$ cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator ($1.83{\pm}0.36$ cGy versus $3.80{\pm}1.67$ cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were $0.97{\pm}0.34$ cGy and $2.3{\pm}0.67$ cGy, respectively. Conclusion: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered.

Angiotensinogen gene M235T polymorphism as a predictor of cardiovascular risk in hypertensive adolescents (고혈압 청소년의 심혈관계 위험요소로서 Angiotensinogen M235T 유전자 다형)

  • Gil, Joo Hyun;Lee, Jung Ah;Park, Eun Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.36-43
    • /
    • 2009
  • urpose : The renin-angiotensin system (RAS) has been demonstrated to play a major role in regulating blood pressure. Therefore, components of the RAS are likely candidate genes that may predispose an individual to essential hypertension and cardiovascular complications. Among them, the M235T polymorphism of the angiotensinogen gene has been speculated to be associated with elevated circulating angiotensinogen concentrations and essential hypertension. This study aimed to analyze the angiotensinogen M235T polymorphism in hypertensive adolescents and investigate its relationship with cardiovascular risks. Methods : Forty Korean hypertensive adolescents (aged 16-17, systolic $BP{\geq}140 mmHg$ and/or diastolic $BP{\geq}90 mmHg$) and fifty seven normal adolescents were included. Obesity index (OI), body mass index (BMI) were calculated. BP was measured by oscillometric methods in resting state. Polymerase chain reaction (PCR) technique was performed on DNA from the hypertensives subjects to analyze the M235T polymorphism. Serum homocysteine, insulin, renin, aldosterone and angiotensin converting enzyme (ACE) were tested according to each genotype. The carotid intima-media thickness (IMT) and carotid artery diameter, Pulse wave velocity (PWV) and ankle-brachial index (ABI) were measured according to each genotype. Results : Genotype frequencies of T/T, M/T and M/M were 62.5%, 35.0%, 2.5%, respectively in hypertensive adolescents. The results were not significantly different compared to control group. Serum insulin, renin levels, BMI and OI were significantly higher in thoses with the M/M genotype as compared to those with the T/T of M/T genotype. Conclusion : This study showed that the M235T polymorphism was not associated with essential hypertension or any cardiovascular risks. Further clinical research is required to ascertain the relationship between this polymorphism and cardiovascular complications in Korean hypertensive adolescents.

Patient Dose in Mammography (유방촬영에서 환자 피폭선량)

  • Shin, Gwi-Soon;Kim, You-Hyun;Kim, Jung-Min;Kim, Chang-Kyun;Yang, Jeong-Hwa;Choi, Jong-Hak
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2005
  • In the present investigation, we analyzed the data of 1,318 patients (2,636 images) who underwent mammographic examinations and obtained the distribution of the patient age and compressed breast thickness. We measured also average glandular doses (AGD) as function of compressed breast thickness. In order to obtain the values of AGD, we measured half value layer (HVL) and tube output (mR/mAs) for each kVp and target/filter combination. Entrance surface air kerma (ESAK) was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs). AGD per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance. We obtained in this study the following conclusions. The mean value of compressed breast thickness for cranio-caudal (CC) view was 35.8mm and that for medio-lateral oblique (MLO) view was 43.3 mm. The mean value of AGD for CC view was 1.55 mGy and that for MLO view was 1.70 mGy. The AGD for MLO view was 0.15 mGy (10%) higher than that for CC view because the thickness for MLO view was on average 4.8 mm higher than that for CC view. The values of AGD increased with increasing compressed brest thickness. The increased AGD value was on average 0.34 mGy per 10 mm in the thickness ranges $10{\sim}80\;mm$, therefore differences between the AGD values of each thickness were relative large. Thus, it is considered to need limited doses for mammography with the upper end of exposure range at several different compressed brest thickness.

  • PDF

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Prosodic Phrasing and Focus in Korea

  • Baek, Judy Yoo-Kyung
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.246-246
    • /
    • 1996
  • Purpose: Some of the properties of the prosodic phrasing and some acoustic and phonological effects of contrastive focus on the tonal pattern of Seoul Korean is explored based on a brief experiment of analyzing the fundamental frequency(=FO) contour of the speech of the author. Data Base and Analysis Procedures: The examples were chosen to contain mostly nasal and liquid consonants, since it is difficult to track down the formants in stops and fricatives during their corresponding consonantal intervals and stops may yield an effect of unwanted increase in the FO value due to their burst into the following vowel. All examples were recorded three times and the spectrum of the most stable repetition was generated, from which the FO contour of each sentence was obtained, the peaks with a value higher than 250Hz being interpreted as a high tone (=H). The result is then discussed within the prosodic hierarchy framework of Selkirk (1986) and compared with the tonal pattern of the Northern Kyungsang dialect of Korean reported in Kenstowicz & Sohn (1996). Prosodic Phrasing: In N.K. Korean, H never appears both on the object and on the verb in a neutral sentence, which indicates the object and the verb form a single Phonological Phrase ($={\phi}$), given that there is only one pitch peak for each $={\phi}$. However, Seoul Korean shows that both the object and the verb have H of their own, indicating that they are not contained in one $={\phi}$. This violates the Optimality constraint of Wrap-XP (=Enclose a lexical head and its arguments in one $={\phi}$), while N.K. Korean obeys the constraint by grouping a VP in a single $={\phi}$. This asymmetry can be resolved through a constraint that favors the separate grouping of each lexical category and is ranked higher than Wrap-XP in Seoul Korean but vice versa in N.K. Korean; $Align-x^{lex}$ (=Align the left edge of a lexical category with that of a $={\phi}$). (1) nuna-ka manll-ll mEk-nIn-ta ('sister-NOM garlic-ACC eat-PRES-DECL') a. (LLH) (LLH) (HLL) ----Seoul Korean b. (LLH) (LLL LHL) ----N.K. Korean Focus and Phrasing: Two major effects of contrastive focus on phonological phrasing are found in Seoul Korean: (a) the peak of an Intonatioanl Phrase (=IP) falls on the focused element; and (b) focus has the effect of deleting all the following prosodic structures. A focused element always attracts the peak of IP, showing an increase of approximately 30Hz compared with the peak of a non-focused IP. When a subject is focused, no H appears either on the object or on the verb and a focused object is never followed by a verb with H. The post-focus deletion of prosodic boundaries is forced through the interaction of StressFocus (=If F is a focus and DF is its semantic domain, the highest prominence in DF will be within F) and Rightmost-IP (=The peak of an IP projects from the rightmost $={\phi}$). First Stress-F requires the peak of IP to fall on the focused element. Then to avoid violating Rightmost-IP, all the boundaries after the focused element should delete, minimizing the number of $={\phi}$'s intervening from the right edge of IP. (2) (omitted) Conclusion: In general, there seems to be no direct alignment constraints between the syntactically focused element and the edge of $={\phi}$ determined in phonology; all the alignment effects come from a single requirement that the peak of IP projects from the rightmost $={\phi}$ as proposed in Truckenbrodt (1995).

  • PDF

Association between physical activity measured using an accelerometer and arterial stiffness based on pulse wave velocity and ankle-brachial index in healthy adults (건강한 성인에서 가속도계로 측정한 신체활동과 맥파전달속도 및 상완-발목 간 혈압비에 기반한 동맥경화지표와의 관계)

  • Lee, Hyunju;Park, Kye Wol;Jun, Ha Yeon;Gwak, Ji Yeon;Kim, Eun Kyung
    • Journal of Nutrition and Health
    • /
    • v.55 no.4
    • /
    • pp.506-520
    • /
    • 2022
  • Purpose: Physical activity (PA) has a beneficial effect on the prevention of arteriosclerosis in healthy adults. The purpose of this study was to analyze the relationship between PA measured using an accelerometer and arterial stiffness in healthy Korean adults. Methods: This study involved 87 subjects (36.8% women) aged 20-64 years. PA was evaluated using an accelerometer (wGT3X-BT, ActiGraph, Florida, USA) for 7 days. Based on the results of the accelerometer measurement, subjects were classified into active and inactive groups according to the World Health Organization (WHO) PA guidelines. The brachial-ankle pulse wave velocity (baPWV) and ankle-brachial index (ABI) to assess arterial stiffness were measured by a non-invasive vascular screening device (VP-1000 Plus, Omron). Results: The average age of the study subjects was 47.7 ± 11.3 years and the WHO PA guideline achievement rate was 29.9%. There was no significant difference in arterial stiffness (baPWV and ABI) between the active and inactive groups. In females, the time spent in light PA were positively correlated with ABI (r = 0.396; p < 0.05) and the number of sedentary bouts over 50 minutes was inversely correlated with ABI (r = -0.402; p < 0.05). However, there was no significant correlation between PA and arterial stiffness in males. Conclusions: The results of this study suggest that light PA and sedentary behavior have a positive correlation with arterial stiffness in females.