Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances (가정용 전기기구에서 발생하는 자장과 유도전압의 측정과 분석)

  • 이복희;이동문;장영태;장근철;엄주홍;강성만;이승칠;박정용
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14" television set, and their values are 2.1 [$\mu$Tp-p]and 140 [mVp-p]at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17" monitor for personal computer and the measured data was approximately 560[mV/$\mu$T]at the same distance. distance.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Study on the Distribution of Vibrio parahaemolyticus along Cheju Coast (제주연안해역의 Vibrio parahaemolyticus 분포에 관한 연구)

  • Song, Min-Kyoung;Kim, Man-Chul;Heo, Moon-Soo
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.1
    • /
    • pp.34-41
    • /
    • 2007
  • A study on the distribution of V. parahaemolyticus among sea water, sea mud, and marine products in Hwabuk, Samyang, Daepo, Jungmun, Pyoson, Anduk, Aewol, and Gwakji on the coastal area of Jeju island was conducted from January to December in 2002. The 2,880 total specimens of 960 sea waters, 960 sea mud, 960 marine products were collected and studied for the rate of isolation of V. parahaemolyticus, and biochemical, serological and antibiotic sensitivity tests were performed. A total of 417 strains of V. parahaemolyticus were isolated and identified from 2,880 total specimens. In the test of biochemical properties, 100 of V. parahaemolyticus isolates in the presence of 0.85% NaCl were positive in the utilization of lysine, ornithine, indole, glucose, and mannitol, and negative in the utilization of ONPG, arginine, sodium citrate, urea, tryptophane, inositol, sorbitol, rhamnose, sucrose, and melibiose, $H_2S$ production and VP reaction, while positive or negative in gelatin liquefaction and utilization of amygdalin or arabinose. The isolation rates to the specimen were 161 strains (16.8%) from 960 of sea waters, 137 strains (14.3%) from 960 of sea mud, and 119 strains (12.4%) from 960 of marine products. The isolation rates of V. parahaemolyticus from 8 coastal areas were 14.4% (52/360) in Hwabuk area, 15.3% (55/360) in Samyang area, 13.6% (49/360) in Daepo area, 18.3% (66/360) Jungmun area, 13.1% (47/360) in Pyosun area, 16.4% (59/360) in Anduk area, 12.5% (45/360) in Aewol area and 12.2% (44/360) in Gwakji area, respectively. The distribution of 417 V. parahaemolyticus, isolates was high at Jungmun with 18.3% (66/360), and from sea water with 16.8% (161/960).

Two Possible Space Groups of Ttis(tekaethylammonium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vanadate(3-),$[V(P_3O_9)_2](NC_8H_{20})3$ (Tris(tetraethylammnnium) [bis(trimetaphosphate $\kappa^3O, O^', O^{"}$)] Vamdate(3-),$[V(P_3O_9)_2](NC_8H_{20})_3$,의 두가지 가능한 공간군)

  • 서일환;이진호
    • Korean Journal of Crystallography
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 1994
  • Two possible space groups of the comfound, VP6N3018C24H:60, are: P 1, a=14.022(1), b=12.644(2), c= 12.640(1)A, a=8038(1), B=102.12(1), r=102.16(1), V=2124.1A3, Z=2, μ=0.47cm-1, d=1.46g/cm3, R=0.083 for 3350 independent reflections with Fo>4o IFI, and C2/c, a=19.32(2), b=16.32(2), c=14.02(1)A, B=105.98(5), β=105.98(5), V=4248.2A3, Z=4 R=0.083 for 1590 independent reflections with Fo>4c IFoI . In the space group P T, there are two monlecules in a unit cell. Vanadium atoms in the two monlecules occupy the two different special positions such that the complete monlecules are accomplished by the two independent center of symmetry. Therefore two different half molecules of bis(trimetaphosphate)vanadate and three molecules of tetraethylammonium are the asymmetric unit in a unit cell. In the space group C2/c, however, the vanadium atom is located at a special position with centrosymmetry, and a two-fold symmetry axis passes through C2/c, N2 and C25 atoms. Therefore the asymmrtic unit in a unit cell consists of a half molecule of bis(trimetaphosphate)vanadate and one and a half molecules of tetraethylammonium. All the molecular conformations in both space groups are very similar: six oxygen atoms coordinated to a vanadium atom in the bi s(trimetaphosphate)vanadate molecule form an octahedron and the four carbon atoms bonded to a nitrogen atom in the tetraethylammonium molecule are disordered so that the eight carbon atoms around nitrogen atom exhibit an irregular dodecahedral form.

  • PDF

A Study on Characteristic of Glass Dosimeter According to Graded Change of Tube Current (유리선량계의 단계별 관전류량 변화에 따른 특성연구)

  • Son, Jin-Hyun;Kim, Seong-Ho;Mun, Hyun-Jun;Kim, Lyun-Kyun;Son, In-Hwa;Kim, Young-Jun;Min, Jung-Whan;Kim, Ki-Won
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.135-141
    • /
    • 2014
  • This study was evaluated the linearity and reproducibility according to dose, and reproducibility according to delay time by changing tube current amount (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively, which are low energy radiations) using Glass Dosimeter (GD) and piranha semiconductor dosimeter which are used for measuring exposure dose. Measurements of radiation dose were performed using external detector of piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Conditions of measurement were 80 kVp, SSD 100 cm and exposure region is $10cm{\times}10cm$. Glass dosimeter was exposed to radiation. Twenty-four glass dosimeters were divided into six groups (5 mAs, 10 mAs, 16 mAs, 20 mAs, 25 mAs, 32 mAs respectively), then measured. This study was resulted by measuring the linearity and reproducibility according to change of tube current in low energy field. In dose characteristic of GD, this study could be useful as previous study with regard to dose characteristic according to change of tube voltage in low energy field.

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

Production and characterization of monoclonal antibodies against white spot syndrome virus (WSSV) (White spot syndrome virus (WSSV)에 대한 단클론 항체 생산 및 특성 분석)

  • Kyoung-Hui, Kong;Choon-Sup, Kim;Kim, Do-Hyung;Wi-Sik, Kim
    • Journal of fish pathology
    • /
    • v.35 no.2
    • /
    • pp.241-246
    • /
    • 2022
  • White spot syndrome virus (WSSV) is a prevalent and virulent pathogen affecting cultured whiteleg shrimp (Litopenaeus vannamei) in Korea. In this study, seven monoclonal antibodies (mAbs) (10A12, 16C3, 17G4, 21G5, 22C4, 23B6 and 24G6) were produced by using purified WSSV. The reactivity of these mAbs was analysed by Western blot (WB), indirect immunofluorescence (IIF), and lateral flow immunochromatographic assay (LFIA). WB analysis demonstrated that three mAbs (17G4, 22C4, and 23B6) reacted specifically to VP28 with an approximate molecular weight of 24 kDa, mAb 16C3 reacted with approximately 17 kDa. IIF analysis demonstrated specific fluorescence signals on gill tissues of WSSV-infected shrimp, with five mAbs (10A12, 16C3, 22C4, 23B6, and 24G6), pleopods from WSSV-infected shrimp were used for LFIA, where, two mAbs (21G5 and 22C4) exhibited positive reaction. In conclusion, it can be inferred that the mAbs usage and specificity depends on the nature of assay used for diagnosis.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

  • Kim, Jun Ho;Abdala-Junior, Reinaldo;Munhoz, Luciana;Cortes, Arthur Rodriguez Gonzalez;Watanabe, Plauto Christopher Aranha;Costa, Claudio;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.133-139
    • /
    • 2020
  • Purpose: This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mechanically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods: Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm×8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm×8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results: High intraobserver and interobserver agreement was found (P<0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56±0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion: Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.