• Title/Summary/Keyword: VOC system

Search Result 235, Processing Time 0.025 seconds

AJ Rent a Car's Customer Satisfaction Management through Service Innovation (AJ렌터카의 서비스 혁신을 통한 고객 만족 경영)

  • Kim, Sang Yong;Lee, Doo Hee;Suh, Koo-Won;Yoo, Weon Sang
    • Asia Marketing Journal
    • /
    • v.13 no.4
    • /
    • pp.213-226
    • /
    • 2012
  • As the Korean rental car industry turned into a mature stage, the competition level has become stronger than ever. In 2006, AJ Rent a Car declared customer satisfaction management as its vision to make a breakthrough. Through various service innovation efforts, AJ has been successfully offering meaningful and differentiated values to the customers. As results, the complaints rate has decreased, while service quality index has significantly increased. These service quality indicators have led to improved customer satisfaction level which was measured by re-purchase intention and customer satisfaction index, and AJ outran its major competitors in these dimensions of competition. The first key success factor of AJ is its effective service system. AJ manages the VOC, ERP, and CRM system in a well organized manner. AJ's another key success factor is a effective service process, which helps the organization share and respond to customer complaints in an efficient way. Finally, the management communicates the clear vision and strategic direction not only with the customers but also with the entire organization. With these three factors combined, AJ has created the service oriented corporate culture. Based on the culture. AJ has been able to develop a strong and sustainable competitive advantage in customer satisfaction management.

  • PDF

Treatment of Malodorous Waste Air Using Hybrid System (하이브리드시스템을 이용한 악취폐가스 처리)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.382-390
    • /
    • 2010
  • In this research hydrogen sulfide, ammonia and toluene were designated as the representative source of malodor and VOC, respectively, frequently generated at the compost manufacturing factory and publicly owned facilities. The optimum operating condition to treat the waste air(2 L/min) containing malodor was constructed using photocatalytic reactor/biofilter process with humidifier composed of fluidized aerobic anf anoxic reactor. The ammonia(300 ppmv) of fed-waste air was removed by 22, 55 and 23% at the stage of photocatalytic reactor, humidifier and biofilter, respectively. The toluene(100 ppmv) of fed-waste air was removed by 20, 10 and 70% at the stage of photocatalytic reactor, humidifier and biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of humidifier and biofilter, respectively. In addition, hydrogen sulfide(10 ppmv) was almost treated at the stage of photocatalytic reactor and its negligible trace was absorbed in humidifier so that it was not detected before biofilter process. The nitrate concentration of the process water from anoxic reactor was found lower by 3 ppm than that from fluidized aerobic reactor. Besides, the dissolved ammonia-nitrogen concentration of the process water from humidifier remained at the high value of 1,500-2,000 ppm, which may be attributed to the existence of ammonium chloride and other source of ammonium nitrogen.

Analysis on Antifungal Activity of Paulownia-Wood Storage Box and Application of Natural Biocide for the Activity Enhancement (오동나무상자의 항균활성 분석 및 활성 증진을 위한 천연 살생물제 적용연구)

  • Chung, Yong-Jae;Kang, So-Yeong;Choi, Yun-A
    • Journal of Conservation Science
    • /
    • v.24
    • /
    • pp.75-83
    • /
    • 2008
  • In order to assess antifungal activity of a wooden storage box, which was made of Paulownia tomentosa and used for keeping ancient documents, antifungal activity of volatile organic compounds emitted from the box was investigated along with qualitative analysis on major substances of the compounds. After collecting floating microorganisms inside air tester, the fungal activity was assessed by counting the number of colonies growing on TSA media. Compared to the control which collected 85 colonies from outdoor, 72 colonies were observed showing reduction rate of 14.82%. Through GC/MS and TDS system analysis, limonene was detected from the volatile organic compounds as characteristic features. When the fungal activity was assessed through fumigation by adding natural biocide BI and BII containing eugenol and anethole as major substances, both biocides showed a strong fungal activity with respectively 92.6%(inside the box) and 99.9%(outdoor) of reduction rate. Although these results didn't clarify antifungal activity of the volatile organic compounds emitted from the Paulownia-wood storage box and their functional components, it was at least confirmed that there is application possibility of natural biocide to use for preservation of ancient documents with increased efficiency in controlling pests of wooden storage boxes.

  • PDF

이중구조 투명전극을 이용한 실리콘 박막 태양전지 효율향상 기법

  • Kim, Hyeon-Yeop;Kim, Min-Geon;Choe, Jae-U;Lee, Jun-Sin;Kim, Jun-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.591-591
    • /
    • 2012
  • 본 연구는 Transparent conducting oxide (TCO, 산화물투명전극)를 이용한 박막태양전지 효율향상에 관한 것으로, 이중의 TCO층(Double-stacked TCO layer)의 효과적인 광학 및 전기적 설계에 관한 것이다. 기존 박막 태양전지에서는 투명전극 TCO layer로서, ITO (Indium-Tin-Oxide), FTO (Fluorine- Tin-Oxide), 및 AZO(Aluminum-doped Zinc Oxide) 등을 사용해 왔다. 각 TCO layer마다 장점이 있지만 단점 또한 존재한다. ITO의 경우 높은 전기적 특성을 가지는 반면 수소 플라즈마에 취약하고 기계적 강도에 취약해 ITO 단일층만으로 박막 태양전지에 적용하는 것에 제한을 받는다. 한편, AZO의 경우 전기적 특성도 우수할 뿐만 아니라 수소 플라즈마에도 내구성이 강한 장점이 있지만, 일함수가 p형 반도체보다 낮아 Schottky junction이 되어, 높은 전위장벽이 형성된다. 이는 정공의 이동을 방해하고, 정공의 축적이 일어나서 순방향 전압을 인가할 때 많은 전류의 감소를 가져온다. 또한, AZO와 p형 반도체 사이의 높은 직렬저항으로 인해 광전압(Voc, Open circuit voltage)와 충실률 (FF, Fill factor)가 떨어진다는 단점이 있다. 본 실험에서는 ITO/AZO 2중구조의 TCO층을 적용하여 상기의 문제점을 해결하고자 한다. 이중 구조 TCO층은 Magnetron sputter system을 이용하여, 단계적으로 증착되었다. 빛이 입사하는 유리에 ITO를 제1전도층으로 증착하였는데, ITO는 입사광의 투과도와 전기전도성이 우수하다. 제2전도층으로는 AZO층을 이용하였으며, 실리콘 반도체층과 접하게 된다. AZO는 실리콘 증착시 발생하는 수소 플라즈마에 안정적이고, 물리적 강도 또한 우수한 장점이 있다. 이중 구조층위에 실리콘 광흡수층(Si absorber)을 증착하였으며, pin 구조를 가진다. 기존, 단일막 TCO층과 2중구조 TCO층을 이용하여, 실리콘 박막 태양전지를 구성하였다. 이때, ITO/AZO의 2중구조를 적용하였을 때 태양 전지 특성이 크게 향상된 결과를 얻을 수가 있었다. 특히, 전류밀도의 경우 ITO, FTO, AZO 각각 14.5 mA/cm2, 11.2 mA/cm2, 8.18 mA/cm2를 나타낸 반면 ITO/AZO 2중구조의 경우 약 17mA/cm2 로 크게 향상 되었고, 태양전지 변환 효율도 각각 7.5%, 6.9%, 4%에서 ITO/AZO 2중 구조의 경우 8.05%로 크게 향상되었다. 본 발표에서는 2중구조 TCO를 이용한 현공정에 적용 가능한 박막태양전지 효율향상 기법에 대해 논의하고자 한다.

  • PDF

Annual Base Performance Evaluation on Cell Temperature and Power Generation of c-Si Transparent Spandrel BIPV Module depending on the Backside Insulation Level (스팬드럴용 투광형 결정계 BIPV창호의 후면단열 조건에 따른 연간 온도 및 발전성능 분석 연구)

  • Yoon, Jong-Ho;Oh, Myung-Hwan;Kang, Gi-Hwan;Lee, Jae-Bum
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.24-33
    • /
    • 2012
  • Recently, finishing materials at spandrel area, a part of curtain-wall system, are gradually forced to improve thermal insulation performance in order to enhance the building energy efficiency. Also, Building Integrated Photovoltaics(BIPV) systems have been installed in the exterior side of the spandrel area, which is generally composed of windows. Those BIPVs aim to achieve high building energy efficiency and supply the electricity to building. However, if transparent BIPV module is combined with high insulated spandrel, it would reduce the PV efficiency for two major reasons. First, temperature in the air space, located between window layer and finishing layer of the spandrel area, can significantly increase by solar heat gain, because the space has a few air density relative to other spaces in building. Secondly, PV has a characteristics of decreased Voltage(Voc and Vmp) with the increased temperature on the PV cell. For these reasons, this research analyzed a direct interrelation between PV Cell temperature and electricity generation performance under different insulation conditions in the spandrel area. The different insulation conditions under consideration are 1) high insulated spandrel(HIS) 2) low insulated spandrel(LIS) 3) PV stand alone on the ground(SAG). As a result, in case of 1) HIS, PV temperature was increased and thus electricity generation efficiency was decreased more than other cases. To be specific, each cases' maximum temperature indicated that 1) HIS is $83.8^{\circ}C$, 2) LIS is $74.2^{\circ}C$, and 3) SAG is $66.3^{\circ}C$. Also, each cases yield electricity generation like that 1) HIS is 913.3kWh/kWp, 2) LIS is 942.8kWh/kWp, and 3) SAG is 981.3kWh/kWp. These result showed that it is needed for us to seek to the way how the PV Cell temperature would be decreased.

Removal of Volatile Organic Contaminant(toluene) from Specific Depth in Aquifer Using Selective Surfactant-Enhanced Air Sparging (계면활성제와 폭기를 이용한 대수층의 특정깊이에 존재히는 휘발성 유기오염물질 (톨루엔)의 휘발제거)

  • Song, Young-Su;Kwon, Han-Joon;Yang, Su-Kyeong;Kim, Heon-Ki
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.565-571
    • /
    • 2010
  • An innovative application of surfactant-enhanced air sparging(SEAS) technique was developed in this study. Using a laboratory-scale physical model packed with water-saturated sand, air sparging was implemented to remove water-dissolved toluene that was introduced into a specific depth of the system with finite vertical width prior to sparging. An anionic surfactant(Sodium dodecylbenzene sulfonate) was introduced into the contaminated layer as in dissolved form in the toluene-contaminated solution for SEAS, whereas no surfactant was applied in the control experiment. Due to the suppressed surface tension of water in the surfactant(and toluene)-containing region, the toluene removal rate increased significantly compared to those without surfactant. More than 70% of the dissolved toluene was removed from the contaminated layer for SEAS application while less than 20% of toluene was removed for the experiment without surfactant. Air intrusion into the contaminated layer during sparging was found to be more effective than that without surfactant, enhancing air contact with toluene-contaminated water, which resulted in improved volatilization of contaminant. This new method is expected to open a new option for remediation of VOC(volatile organic compound)-contaminated aquifer.

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.

Identification of Vegetable Oil-added Sesame Oil by a Mass Spectrometer-based Electronic Nose (Mass Spectrometer를 바탕으로 한 전자코를 이용한 식물성 유지가 혼합된 참기름의 판별 분석)

  • Son, Hee-Jin;Hong, Eun-Jeung;Ko, Sanghoon;Choi, Jin Young;Noh, Bong-Soo
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.275-281
    • /
    • 2009
  • Sesame oils are partially mixed with other vegetable oils due to high price in a Korean market. To find out authentic sesame oil, a mass spectrometer-based electronic nose (MS-based E-nose) was used. Sesame oil (Se) was blended with soybean oil (So) or corn oil (Co) at the ratio (Se:So, Se:Co) of 97:3, 94:6, 91:9, 88:12 and 85:15, respectively. Intensities of each fragment from sesame oil by MS-based E-nose were completely different from those of soybean oil or corn oil. The obtained results were used for discriminant function analysis (DFA). Volatile organic components (VOC) of soybean oil or corn oil were similar to those of fresh air and DFA plot indicated a significant separation of pure sesame oil and pure other oil. The group of the mixed oil was seperated with that of sesame oil in DFA plot and the added amount of soybean oil to sesame oil was correlated with discriminant function first score (DF1). MS based E-nose system could be used as an efficient method to investigate the purity of sesame oil.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.