• 제목/요약/키워드: VMAT

검색결과 130건 처리시간 0.022초

Feasibility Study of Deep Inspiration Breath-Hold Based Volumetric Modulated Arc Therapy for Locally Advanced Left Sided Breast Cancer Patients

  • Swamy, Shanmugam Thirumalai;Radha, Chandrasekaran Anu;Kathirvel, Murugesan;Arun, Gandhi;Subramanian, Shanmuga
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권20호
    • /
    • pp.9033-9038
    • /
    • 2014
  • Background: The purpose of this study was to assess the feasibility of deep inspiration breath-hold (DIBH) based volumetric modulated arc therapy (VMAT) for locally advanced left sided breast cancer patients undergoing radical mastectomy. DIBH immobilizes the tumor bed providing dosimetric benefits over free breathing (FB). Materials and Methods: Ten left sided post mastectomy patients were immobilized in a supine position with both the arms lifted above the head on a hemi-body vaclock. Two thermoplastic masks were prepared for each patient, one for normal free breathing and a second made with breath-hold to maintain reproducibility. DIBH CT scans were performed in the prospective mode of the Varian real time position management (RPM) system. The planning target volume (PTV) included the left chest wall and supraclavicular nodes and PTV prescription dose was 5000cGy in 25 fractions. DIBH-3DCRT planning was performed with the single iso-centre technique using a 6MV photon beam and the field-in-field technique. VMAT plans for FB and DIBH contained two partial arcs ($179^{\circ}-300^{\circ}CCW/CW$). Dose volume histograms of PTV and OAR's were analyzed for DIBH-VMAT, FB-VMAT and DIBH-3DCRT. In DIBH mode daily orthogonal ($0^{\circ}$ and $90^{\circ}$) KV images were taken to determine the setup variability and weekly twice CBCT to verify gating threshold level reproducibility. Results: DIBH-VMAT reduced the lung and heart dose compared to FB-VMAT, while maintaining similar PTV coverage. The mean heart $V_{30Gy}$ was $2.3%{\pm}2.7$, $5.1%{\pm}3.2$ and $3.3%{\pm}7.2$ and for left lung $V_{20Gy}$ was $18.57%{\pm}2.9$, $21.7%{\pm}3.9$ and $23.5%{\pm}5.1$ for DIBH-VMAT, FB-VMAT and DIBH-3DCRT respectively. Conclusions: DIBH-VMAT significantly reduced the heart and lung dose for left side chest wall patients compared to FB-VMAT. PTV conformity index, homogeneity index, ipsilateral lung dose and heart dose were better for DIBH-VMAT compared to DIBH-3DCRT. However, contralateral lung and breast volumes exposed to low doses were increased with DIBH-VMAT.

손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교 (Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk)

  • 김경아;나경수;서석진;이제희
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.57-68
    • /
    • 2017
  • 목 적: 본 연구는 모양이 불규칙하고 손상위험장기(Organ At Risk, OAR)에 매우 인접한 타겟(Target)의 방사선 치료 시, 비동일평면상(Non-coplanar)의 빔(Beam)을 이용한 Fixed-field 세기변조 방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 용적변조회전 방사선치료(Volumetric Modulated Arc Therapy, VMAT) 치료계획의 유용성을 평가 및 비교해 보고자 하였다. 대상 및 방법: 본원에서 True Beam STX(Varian Medical Systems, USA)를 이용하여 전체 두피(Whole Scalp), 부분적 두피(Partial Scalp), 그리고 전체 뇌실(Whole Ventricle)에 방사선 치료를 받은 환자 중 각 부위별로 2명 씩, 총 6명을 대상으로 하였다. VMAT 치료계획 시, Beamlet에 포함되는 OAR의 용적을 최소화하기 위해 Coplanar 또는 Non-coplanar 빔을 이용하였고, Fixed-field IMRT는 6명 모두 2개 이상의 카우치(Couch) 각도를 이용한 Non-coplanar IMRT(이하 ncIMRT)로 치료계획 하였다. 결 과: 양측 수정체, 양측 시신경, 시신경 교차, 그리고 뇌 줄기의 최대선량과 양측 안구와 해마의 평균선량을 측정하였고, 6명 모두 9개의 OAR 중 6개 이상에서 VMAT 치료계획이 ncIMRT보다 1.1배에서 8.2배가량 높은 선량 값을 나타내었다. 전체 두피와 부분적 두피의 치료 시, 20 Gy가 조사되는 뇌의 용적은 VMAT이 ncIMRT의 2배 이상이었고, 전체 뇌실의 치료 시에는 두 치료계획이 큰 차이를 보이지 않았다. 타겟 Coverage는 두 치료계획 모두 $PTV_{100%}=95%$를 만족시켰고, 타겟 내 최대선량과 치료 시 필요한 총 Monitor Unit(MU)은 ncIMRT가 VMAT보다 높았으며 두 치료계획 모두 임상적용을 위한 Gamma test 시행 결과, 2 mm/2 % 조건을 통과하였다. 결 론: 본 연구 결과, ncIMRT는 VMAT에 비해 치료 시 필요한 MU가 높아 치료시간과 장비의 로딩(Loading)을 증가시키므로 치료의 효율성은 다소 떨어지지만, VMAT과 비슷한 타겟 Coverage를 유지하면서, OAR의 선량은 훨씬 감소시키는 것을 알 수 있었다. 따라서 모양이 불규칙하고 OAR에 매우 인접해 있는 타겟의 방사선 치료 시에는 ncIMRT 치료계획을 고려해 볼 필요가 있다고 사료된다.

  • PDF

IMRT(Intensity Modulated Radiation Therapy)전달 기법과 FFF(Flattening Filter Free) 빔을 이용한 요철 부위 피부 선량 증가 방법에 대한 고찰 (A Study on IMRT (Intensity Modulated Radiation Therapy) Delivery Technique and FFF (Flattening Filter Free) Beam to Increase Skin Dose to Irregularly Shaped Skin Surface.)

  • 우헌;손상준;제영완
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.7-12
    • /
    • 2022
  • 목 적: 볼루스 적용이 어려운 코와 같은 요철 부위 치료 시 피부 선량 확보에 어려움이 있는 경우, IMRT(Intensity Modulated Radiation Therapy)전달 기법 과 평균 에너지가 낮은 FFF(Flattening Filter Free)를 조합한 치료 계획으로 피부 선량 증가 여부를 팬텀 실험을 통해 알아보고자 하였다. 대상 및 방법: 두경부암 치료시 가장 흔하게 사용하는 6MV-FF(Flattening Filter) VMAT(Volumetric-Modulated Arc Therapy) 치료계획을 기준으로 정하고, VMAT와 IMRT, FF와 FFF, 5 mm 볼루스 적용 유무를 조합하여 비교군을 생성하였다. 란도 팬텀 콧등에 가상 타겟을 생성하였고, 5 mm 의 가상의 볼루스를 란도 팬텀 콧등 위에 완전 밀착을 가정하여 적용하였다. 팬텀의 코를 기준으로 5개 측정지점을 정하고 각각의 치료계획 을 치료테크닉과 bolus 적용유무에 맞게 치료계획 당 3회를 조사하여 흡수선량을 측정하였다. 결 과: FF vs FFF 에서의 피부선량 차이는 VMAT bolus off에서 FFF인 경우 증가하였고, IMRT bolus off의 경우 차이를 나타내지 않았다. VMAT bolus 5 mm, IMRT bolus 5 mm에서는 FFF에서 오히려 피부선량이 감소되는 것을 확인 할 수 있었다. VMAT vs IMRT 피부선량 차이는 FFF bolus off 의 경우에만 피부선량이 증가했고, 나머지는 통계적 차이가 없었다. bolus off vs bolus 5 mm 에서의 피부선량 차이는 IMRT FFF 을 사용했을 경우만 제외하고는 모두 bolus 5 mm 에서 피부선량이 증가하는 것을 확인하였다. IMRT와 FFF를 조합한 치료 계획은 통상적으로 사용되는 VMAT와 FF를 사용하여 5 mm 볼루스를 적용한 치료 계획 피부선량의 측정값을 분석한 결과 통계적으로 유의미한 차이를 발견하지 못했다. 따라서 IMRT_FFF 를 사용함으로써 VMAT_FF 에 5 mm 볼루스 적용한 것과 비슷한 수준의 피부선량 전달이 가능할 것이라 사료되며, 이는 높은 피부선량이 필요하지만, 볼루스 적용이 어려운 환자와 같은 경우에 유용할 수 있다. 결 론: 볼루스 적용이 어려운 환자의 경우, VMAT와 FF에 비교하여 IMRT와 FFF를 적절히 조합한 치료 계획으로 피부 선량 증가를 기대할 수 있다.

직장암 치료 시 치료계획에 따른 선량평가 연구 (A study of the plan dosimetic evaluation on the rectal cancer treatment)

  • 정현학;안범석;김대일;이양훈;이제희
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.171-178
    • /
    • 2016
  • 목 적 : 직장암 방사선 치료 시 대퇴골두의 선량을 최소화하기 위해, 보편적인 치료방법인 3문 입체조형치료계획(3D Conformal radiation therapy)과 5문 입체조형치료계획 그리고 용적변조방사선치료(Volumetric Modulated Arc Therapy, 이하 VMAT) 계획의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 21EX(Varian Medical Systems, USA)를 이용하여 치료 받은 직장암 환자 10명을 대상으로 3문, 5문 입체조형치료계획과 VMAT 전산화치료계획을 각각 세우고 이에 대한 선량분포를 비교분석하였다. 전산화 치료계획은 Eclipse(Ver 10.0.42, Varian, USA)를 이용하였으며, 선량계산을 위해 PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 3문 치료계획은 6MV POST field 와 15MV LT, RT field를 갠트리 각도 $0^{\circ}$, $270^{\circ}$, $90^{\circ}$로 구성하였고, 5문 치료계획은 6MV POST field와 15MV RAO, RPO, LAO, LPO field를 갠트리 각도 $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ 로 환자 체표면을 감싸는 형태로 구성하였다. VMAT 치료계획은 갠트리 회전반경이 $360^{\circ}$인 1개의 ARC를 이용하여 수립하였다. 처방선량은 30회에 걸쳐 직장에 총 선량이 54Gy가 되도록 하였다. VMAT 치료계획시 최적화(Optimization) 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 2회의 최적화와 선량계산과정을 거쳤으며 처방선량의 100%가 표적용적의 95%를 포함할 수 있도록 Plan normalization을 조절하였다. 각 치료 계획의 Total MU, 대퇴골두와 acetabular fossa의 최대선량, PTV의 H.I. (Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification Q.A. (Gamma test)를 실시하였다. 결 과 : Rt. femoral head 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 53.08 Gy, 50.27 Gy, 30.92 Gy를 나타냈다. 마찬가지로 Lt. femoral head 에서도 같은 순으로 평균 53.68 Gy, 51.01 Gy, 평균 29.23 Gy를 나타냈다. Rt. Aceta fossa 의 최대선량은 3문, 5문, VMAT 치료계획 순으로 평균 54.86 Gy, 52.40 Gy, 30.37 Gy의 값을 보였다. Lt. Aceta fossa에서 또한 같은 순으로 평균 54.90 Gy, 52.77 Gy, 평균 31.79 Gy를 나타내어, both femoral head 와 aceta fossa의 최대선량이 3문, 5문, VMAT 치료계획 순으로 높았다. PTV에 대한 H.I.는 모두 서로 비슷한 결과를 나타냈고, C.I.는 3문, 5문, VMAT 치료계획 순으로 평균 1.64, 1.48, 평균 0.99로 VMAT 치료계획이 가장 낮은 것으로 나타났다. Total MU는 VMAT 치료계획이 3문과 5문 치료계획에 비해 각각 평균 124.4MU, 299MU 더 많이 사용하는 것으로 나타났다. VMAT 치료계획에 대한 IMRT verification Q.A. 결과 2mm / 2%, Gamma pass rate 90.0% 기준을 모두 초과하여 통과하였다. 결 론 : VMAT 치료계획은 3D 치료계획과 비교하여 대부분의 평가지표에서 우수한 것으로 나타났다. 특히 대퇴골두의 선량을 크게 감소 시켰으며, 저선량 영역에서는 소장이 받는 선량이 증가 하였으나 오히려 고선량 영역에서는 우수한 선량분포를 보였다. 하지만 VMAT을 지원하지 않는 장비와 치료계획 시 추가되는 Contouring, 그리고 정도관리에 관한 수고 등의 현실적인 제약 때문에 VMAT 치료계획을 선택하기 어려운 경우가 있을 수 있다. 5문 치료계획은 기존 3문 치료계획에 비해, 추가적인 문제에 구애받지 않고 대퇴골두의 선량을 줄일 수 있는 장점이 있다. 따라서 각 병원 상황에 맞게 치료계획을 선택하여 방사선 치료 효과를 높인다면, 직장암 환자의 효율적인 방사선치료 및 생존 기간의 연장뿐만 아니라 삶의 질 향상에도 도움이 될 것으로 판단한다.

  • PDF

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

Dosimetric and Radiobiological Evaluation of Dose Volume Optimizer (DVO) and Progressive Resolution Optimizer (PRO) Algorithm against Photon Optimizer on IMRT and VMAT Plan for Prostate Cancer

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee;Eom, Keun-Yong;Song, Changhoon;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.106-114
    • /
    • 2018
  • This study aimed to compare the performance of previous optimization algorithms against new a photon optimizer (PO) algorithm for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans for prostate cancer. Eighteen patients with prostate cancer were retrospectively selected and planned to receive 78 Gy in 39 fractions of the planning target volume (PTV). All plans for each patient optimized with the dose volume optimizer (DVO) and progressive resolution optimizer (PRO) algorithms for IMRT and VMAT were compared against plans optimized with the PO within Eclipse version 13.7. No interactive action was performed during optimization. Dosimetric and radiobiological indices for the PTV and organs at risk were analyzed. The monitor units (MU) per plan were recorded. Based on the plan quality for the target coverage, prostate IMRT and VMAT plans using the PO showed an improvement over DVO and PRO. In addition, the PO generally showed improvement in the tumor control probability for the PTV and normal tissue control probability for the rectum. From a technical perspective, the PO generated IMRT treatment plans with fewer MUs than DVO, whereas it produced slightly more MUs in the VMAT plan, compared with PRO. The PO showed over potentiality of DVO and PRO whenever available, although it led to more MUs in VMAT than PRO. Therefore, the PO has become the preferred choice for planning prostate IMRT and VMAT at our institution.

Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • 제44권1호
    • /
    • pp.32-42
    • /
    • 2019
  • Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and pelvis. One plan for each treatment site was selected from real VMAT cases and contours were mapped into the computational human phantom where the same plan as real VMAT plan was created and called plan-class specific reference (pcsr) QA plan. We delivered this pcsr QA plan on a daily basis over the full research period and tracked how much MLC movement and dosimetric error occurred in regular delivery. Several real patients under treatments were also tracked to test the usefulness of pcsr QA through comparisons between them. We used dynalog file viewer (DFV) and Dynalog file to analyze position and speed of individual MLC leaf. The gamma pass rate from portal dosimetry for different gamma criteria was analyzed to evaluate analyze dosimetric accuracy. Results and Discussion: The maxRMS of MLC position error for all plans were all within the tolerance limit of < 0.35 cm and the positional variation of maxPEs for both pcsr and real plans were observed very stable over the research session. Daily variations of maxRMS of MLC speed error and gamma pass rate for real VMAT plans were observed very comparable to those in their pcsr plans in good acceptable fluctuation. Conclusion: We believe that the newly proposed pcsr QA would be useful and helpful to predict the mid-term quality of real VMAT treatment delivery.

다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가 (A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam)

  • 염미숙;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.31-43
    • /
    • 2015
  • 목 적 : 정위적체부방사선치료(Stereotatic body radiation therapy, SBRT)는 원발성 종양과 전이성 종양의 치료법으로 이용되어진다. SBRT는 높은 선량을 전달하기 때문에 MU(Monitor unit)의 증가로 치료시간이 길어지고 치료계획용적(Planning Target Volume, PTV) 주변의 정상장기를 효과적으로 보호할 수 있는 치료계획이 필요하다. 특히 다중표적의 경우 SBRT를 여러 번에 나누어 치료해야하거나 선량 겹침으로 인한 고 선량 영역(Hot spot)이 생길수도 있다. 본 연구는 다중표적 간암에서 TrueBeam STx(Varian, USA)의 무편평화여과기선질(Flattening filter free, FFF) beam을 이용한 용적변조회전치료(Volumetric modulated arc therapy, VMAT)의 유용성을 평가하고자 한다. 대상 및 방법 : 다중표적 간암의 SBRT를 시행하는 5명의 환자를 대상으로 TrueBeam STx의 10MV FFF beam을 이용한 VMAT과 15MV 편평화여과기선질(Flattening filter, FF) beam을 이용한 입체조형치료(conformal radiotherapy, CRT)계획을 세웠다. 두 치료계획을 비교하기 위하여 선량용적히스토그램(Dose Volume Histogram, DVH)을 이용하여 치료계획용적(Planning Target Volume, PTV), 간, 십이지장, 장, 식도, 척수에 들어가는 선량을 평가하고 전체 MU 값을 비교하였다. 또한 두 치료계획의 치료시간을 비교하기 위하여 Beam on time을 평가하였다. 결 과 : PTV에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity index, HI), 처방선량포함지수(Paddick's Conformity Index, PCI)의 평균값은 VMAT에서 각각 $1.006{\pm}0.028$, $1.098{\pm}0.016$, $1.132{\pm}0.084$, CRT에서 $1.381{\pm}0.419$ $1.136{\pm}0.042$, $1.534{\pm}0.465$로 평가되었다. 정상장기에 대한 선량은 CRT에서 VMAT 보다 약 1.8배 높은 선량으로 평가되었다. 전체 MU값은 VMAT에서 약 1.3배 높게 평가되었고 VMAT과 CRT 두 치료계획의 평균 Beam on time은 각각 6.8분, 21.3분으로 평가되었다. 결 론 : 다중표적 간암의 정위적체부방사선치료에서 FFF Beam을 이용한 VMAT을 적용하면 선량 겹침 없이 다중표적을 한 번에 치료할 수 있으며 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 FFF Beam의 높은 선량률(Dose rate)을 이용하여 치료시간을 단축시켜 치료 중 발생할 수 있는 오차를 감소시킬 수 있다.

  • PDF

다발성 전이암 환자의 방사선치료 시 저선량 영역 감소를 위한 용적조절 회전 방사선치료(Volumetric Modulated Arc Therapy) 기법의 유용성 평가 (Usefulness assessment of the Volumetric Modulated Arc Therapy technique for reducing low-dose areas during radiotherapy for patients with multiple metastatic cancers)

  • 최윤원;정동민;김세영;박령황;김이지;조용완 ;권용재;박별님;유경민;문호경;장동재;이재영;임다영;이상규;백종걸
    • 대한방사선치료학회지
    • /
    • 제35권
    • /
    • pp.23-31
    • /
    • 2023
  • 목 적: 다발성 전이암 환자의 방사선치료 시 저선량 영역을 줄이기 위해 Non-Treat Functionailty-Volumetric Modulated Arc Therapy(NTF-VMAT)과 Treat Functionality VMAT(TF-VMAT)치료계획을 수립하고 비교하여 유용성을 평가하고자 한다. 대상 및 방법: Arccheck phantom에서 X, Y, Z 축에 2 cm, 4 cm, 6 cm 간격으로 치료계획용적 위치를 쌍(Pair)으로 설정하였다. 이를 바탕으로 NTF-VMAT와 TF-VMAT의 저선량 체적을 측정하여 비교·분석하였다. 결 과: 처방선량의 10% ~ 70% 범위 내에서 NTF-VMAT와 TF-VMAT의 18개 전산화 치료계획을 분석한 결과, 각 축에서 저선량 영역의 체적 차이는 X축에서는 최대 -47.6%, 최소 -2.2%, Y축에서는 최대 -17.5%, 최소 -7.3%의 차이가 나타났다. Z축에서는 최대 -39.7%의 차이를 보였으며, 가장 적은 차이는 -6.8%로 나타났다. 결 론: 다발성 전이암 환자의 방사선치료 시 TF-VMAT 치료계획이 NTF-VMAT에 비해 저선량 영역을 10~40% 줄일 수 있었다. 이는 Island block technique이 적용된 Treat Functionaliy을 이용하여 선량 분포를 개선하고, 부작용을 최소화하여 다발성 전이암 환자의 치료에 유용할 것으로 사료된다.

  • PDF