• Title/Summary/Keyword: VITEK MS system

Search Result 6, Processing Time 0.024 seconds

Identification of Uncommon Candida Species Using Commercial Identification Systems

  • Kim, Tae-Hyoung;Kweon, Oh Joo;Kim, Hye Ryoun;Lee, Mi-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.12
    • /
    • pp.2206-2213
    • /
    • 2016
  • Recently, several studies have revealed that commercial microbial identification systems do not accurately identify the uncommon causative species of candidiasis, including Candida famata, Meyerozyma guilliermondii, and C. auris. We investigated the accuracy of species-level identification in a collection of clinical isolates previously identified as C. famata (N = 38), C. lusitaniae (N = 1 2), and M. guilliermondii (N = 5) by the Vitek 2 system. All 55 isolates were re-analyzed by the Phoenix system (Becton Dickinson Diagnostics), two matrix-assisted laser desorption ionization-time of flight mass spectrometry analyzers (a Vitek MS and a Bruker Biotyper), and by sequencing of internal transcribed spacer (ITS) regions or 26S rRNA gene D1/D2 domains. Among 38 isolates previously identified as C. famata by the Vitek 2 system, the majority (27/38 isolates, 71.1%) were identified as C. tropicalis (20 isolates) or C. albicans (7 isolates) by ITS sequencing, and none was identified as C. famata. Among 20 isolates that were identified as C. tropicalis, 17 (85%) were isolated from urine. The two isolates that were identified as C. auris by ITS sequencing originated from ear discharge. The Phoenix system did not accurately identify C. lusitaniae, C. krusei, or C. auris. The correct identification rate for 55 isolates was 92.7% (51/55 isolates) for the Vitek MS and 94.6% (52/55 isolates) for the Bruker Biotyper, as compared with results from ITS sequencing. These results suggest that C. famata is very rare in Korea, and that the possibility of misidentification should be noted when an uncommon Candida species is identified.

An Evaluation of the Rapid Antimicrobial Susceptibility Test by VITEK MS and VITEK 2 Systems in Blood Culture (혈액배양에서 VITEK MS와 VITEK 2 System을 이용한 신속 항생제 감수성 시험의 유용성 평가)

  • Park, Kang-Gyun;Yu, Young-Bin;Yook, Keundol;Kim, Sang-Ha;Kim, Sunghyun;Kim, Young Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.279-284
    • /
    • 2017
  • The results of rapid antimicrobial susceptibility test (AST) in blood cultures were obtained by inoculating the bacteria directly into the VITEK MS and the VITEK 2 systems without subculturing in the blood culture positive medium. The obtained results were compared with the results using a standard method to evaluate their reliability and accuracy. The direct AST results in blood culture positive specimens were 97.9% (1,936/1,978), consistent with the standard AST results. Gram-positive bacteria showed a concordance rate of 97.2% (1,051/1,081), a very major error rate of 0.5% (5/1,081), a major error rate of 0.1% (1/1,081), and a minor error rate of 2.2% (24/1,081). Staphylococcus epidermidis was the main cause of discordance, and gentamicin (N=9) and fusidic acid (N=8) showed high errors. The overall concordance rate and minor error among the Gram-negative bacteria were 98.6% (885/897) and 1.4% (12/897), respectively. Escherichia coli and Pseudomonas aeruginosa were the major causative bacteria of Gram-negative bacteria. Among them, amoxicillin/clavulanic acid (N=3) showed high error. Direct AST met the CLSI criteria and shortened the reporting time by 24 hours; however, we found that there was a need to perform an addition test via disk diffusion for antimicrobials with very large errors. These results suggest that the method of direct AST in blood culture positive medium may be very useful in efficiently treating patients.

An Evaluation of Vitek MS System for Rapid Identification of Bacterial Species in Positive Blood Culture (혈액배양 양성검체에서 패혈증 원인균 신속동정을 위한 Vitek MS 시스템의 유용성 평가)

  • Park, Kang-Gyun;Kim, Sang-Ha;Choi, Jong-Tae;Kim, Sunghyun;Kim, Young-Kwon;Yu, Young-Bin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.407-412
    • /
    • 2017
  • The aim of this study was to shorten the time required for subculture and bacterial identification and obtain a simple and rapid identification method for new test methods for bloodstream infections. The following results were obtained using a mass spectrometer. In Vitek 2, 208 (81.8%) cases were well-identified and 45 isolates were not identified in blood cultures. Among 208 cases, 146 (57.5%) were Gram positive bacteria and 108 (42.5%) were Gram negative bacteria. In total, 233 were identified to the species level and 21 were identified to the genus level. The identification error was found to be Propionibacterium acnes as Clostridium bifermentans. The accuracy of Enterobacteriaceae, glucose non-fermentative bacilli (GNFB), and staphylococci were 81/83 (97.6%), 12/15 (80.0%), and 72/85 (84.7%), respectively. The concordance rate of Vitek 2 and Vitek MS by the direct method was 81.8% and 45 isolates were not identified. Most of the unidentified bacteria were Gram positive bacteria (N=37). The Gram positive bacteria were streptococci (14), coagulase-negative staphylococci (CNS) (11), enterococci (3), Staphylococcus aureus (2), Micrococcus spp. (2), Bacillus spp. (2) and Actinomyces odontolyticus, Finegoldia magna, and Peptostreptococcus spp. The results reporting time was reduced to 24~72 hours compared to the conventional method. The rate of identification of the aerobic and anaerobic cultures was similar, but the use of an anaerobic culture did not require a dissolution process, which could shorten the sample preparation time. These results suggest that the method of direct identification in blood cultures is very useful for the treatment of patients. In further studies, it might be necessary to further improve the method for identifying streptococci and CNS, which were lacking in accuracy in this study.

Evaluation of Microbiological Contamination of Water Purifiers at Two Universities in Chungcheong Region

  • Jin Young Yun
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.256-262
    • /
    • 2023
  • The purpose of this study is to investigate microbial contamination in water purifiers from two universities (A and B) in Chungcheong region and to evaluate about the harmfulness of the isolated bacteria to the human. The degree of microbiological contamination of six water purifiers at university A was investigated three times from July 2018 to September 2019, and nine water purifiers at university B were investigated in 2023. The isolated bacteria were biochemically identified using an API kit and Vitek-2 system, and then the bacteria were identified to the species level using MALDI-TOF MS. In addition, the possibility of human infection of the isolated bacteria was evaluated through a literature search. In July 2018 and September 2019, the number of bacteria isolated inside the faucet was below the acceptable standard for hot water, but exceed for cold water in all water purifiers. In January and September 2019, bacteria exceeding the acceptable standards were isolated nine times from the cold water of six water purifies (a total of 12 water purifiers). Bacteria identified by MALDI-TOF MS included anaerobic bacteria (Clostridium novyi, Clostridium themopalmarium etc.), Gram-positive bacilli (Microbacterium testaceum, Arthrobacter woluwensis etc.), and Gramnegative bacilli (Acinetobacter nosocomialis, Comamonas kerstersii etc.), which are difficult identify by biochemical methods. In conclusion, bacteria exceeding the acceptable standard were isolated from the cold water of most of the water purifiers. Most of the isolated bacteria were low-pathogenic bacteria from natural environment, but opportunistic bacteria that can cause infection in humans were also isolated from some water purifiers.

A Comparison of Genospecies of Clinical Isolates in the Acinetobacter spp. Complex Obtained from Hospitalized Patients in Busan, Korea

  • Park, Gyu-Nam;Kang, Hye-Sook;Kim, Hye-Ran;Jung, Bo-Kyung;Kim, Do-Hee;Chang, Kyung-Soo
    • Biomedical Science Letters
    • /
    • v.25 no.1
    • /
    • pp.40-53
    • /
    • 2019
  • Of the Acinetobacter spp., A. baumannii (genospecies 2) is the most clinically significant in terms of hospital-acquired infections worldwide. It is difficult to perform Acinetobacter-related taxonomy using phenotypic characteristics and routine laboratory methods owing to clusters of closely related species. The ability to accurately identify Acinetobacter spp. is clinically important because antimicrobial susceptibility and clinical relevance differs significantly among the different genospecies. Based on the medical importance of pathogenic Acinetobacter spp., the distribution and characterization of Acinetobacter spp. isolates from 123 clinical samples was determined in the current study using four typically applied bacterial identification methods; partial rpoB gene sequencing, amplified rRNA gene restriction analysis (ARDRA) of the intergenic transcribed spacer (ITS) region of the 16~23S rRNA, the $VITEK^{(R)}$ 2 system (an automated microbial identification system) and matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). A. baumannii isolates (74.8%, 92/123) were the most common species, A. nosocomialis (10.6%, 13/123) and A. pittii isolates (7.5%, 9/123) were second and third most common strains of the A. calcoaceticus-A. baumannii (ACB) complex, respectively. A. soli (5.0%, 6/123) was the most common species of the non-ACB complex. RpoB gene sequencing and ARDRA of the ITS region were demonstrated to lead to more accurate species identification than the other methods of analysis used in this study. These results suggest that the use of rpoB genotyping and ARDRA of the ITS region is useful for the species-level identification of Acinetobacter isolates.

A Study on Microbial Community Diversity and Antibiotic Resistance in Public Waters in Gwangju (광주지역 공공수역의 미생물 군집 다양성 및 항생제 내성에 관한 연구)

  • Sun-Jung Kim;Ji-Young Park;Seung-Ho Kim;Min-Hwa Lim;Ji-Yong Yu;Kyu-Sung Han;Se-Il Park;Gwangyeob Seo;Gwangwoon Cho
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.2
    • /
    • pp.93-101
    • /
    • 2024
  • Background: As pollutants caused by non-point sources flow into rivers, river water quality monitoring for fecal pollution is becoming increasingly important. Objectives: This study was conducted to investigate the distribution of microbial communities in the Yeongsangang River water system and sewage treatment plants in Gwangju and to evaluate their antibiotic resistance. Methods: In the experiment, samples were distributed to five selective media at each point and then cultured for 18 to 24 hours. When bacteria were observed, they were sub-cultured by size and shape and identified using MALDI-TOF MS equipment. When identification was completed, 17 types of antibiotic susceptibility tests were performed using VITEK II equipment, focusing on gram-negative dominant species among the identified strains. Results: During the study period, a total of 266 strains were isolated from 39 samples. Gram-positive bacteria were 37 strains in four genera, or 13.9% of the total, and Gram-negative bacteria were 229 strains in 23 genera, or 86.1% of the total. Antibiotic susceptibility testing of 23 strains, the major dominant species, showed that one strain (4.3%) was resistant to only one antibiotic, and two strains (8.7%) were 100% susceptible to the 17 antibiotics tested. The other 20 strains (87.0%) were multidrug resistant bacteria resistant to two or more antibiotics. There were various types of multidrug resistance. Among them, penicillin and cephalosporin series showed the highest resistance. Conclusions: Based on the results of this study, it was found that the bacterial community structure changed according to regional and environmental factors, and it was judged that continuous research such as genetic analysis of antibiotic-resistant bacteria present in natural rivers is necessary.