• Title/Summary/Keyword: VC-1

Search Result 361, Processing Time 0.028 seconds

DNA Single Strand Breaks of Perchloroethylene and Its Bio-degradation Products by Single Cell Gel Electrophoresis Assay in Mammalian Cell System

  • Jeon, Hee-Kyoung;Kim, Young-Seok;Sarma, Sailendra Nlath;Kim, Youn-Jung;Sang, Byoung-In;Ryu, Jae-Chun
    • Molecular & Cellular Toxicology
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 2005
  • Perchloroethylene (tetrachloroethylene, PCE), a dry cleaning and degreasing solvent, can enter ground-water through accidental leak or spills. PCE can be degraded to trichloroethylene (TCE), 1, 1-dichloroethylene (DCE) and vinyl chloride (VC) as potential bio-product. These compounds have been reported that they can cause clinical diseases and cytotoxicity. However, only a little genotoxic information of these compounds has been known. In this study, we investigated DNA single strand breaks of PCE, TCE, DCE and VC by single cell gel electrophoresis assay, (comet assay) which is a sensitive, reliable and rapid method for DNA single strand breaks with mouse lymphoma L5178Y cells. From these results, $37.5\;{\mu}g/ml$ of PCE, $189\;{\mu}g/ml$ of TCE and $56.4\;{\mu}g/ml$ of DCE were revealed significant DNA damages in the absence of S-9 metabolic activation system meaning direct-acting mutagen. And in the presence of S-9 metabolic activation system, $41.5\;{\mu}g/ml$ of PCE, $328.7\;{\mu}g/ml$ of TCE and $949\;{\mu}g/ml$ of DCE were induced significant DNA damage. In the case of VC, it was revealed a significant DNA damage in the presence of S-9 metabolic activation system. Therefore, we suggest that chloroethylene compounds (PCE, TCE, DCE and VC) may be induced the DNA damage in a mammalian cell.

Prediction of Postoperative Pulmonary Function Following Thoracic Operations - Perfusion Lung Scanning Method - (폐관류스캔에 의한 폐절제술후 폐기능 예측)

  • Park, Guk-Yang;Yu, Hoe-Seong;Kim, Ju-Hyeon
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.209-216
    • /
    • 1986
  • The purpose of this study is to predict postoperative lung function by perfusion lung scanning method. 40 patients who underwent lobectomy or pneumonectomy between 1983-1985 were analyzed. Mean preoperative FEV1 was 2.36 L in lobectomy cases and 1.73 L in pneumonectomy cases. Preoperative and postoperative lung function were measured by routine spirometry in sitting position. Perfusion lung scanning was performed by 99mTc-MAA radioisotope. Postoperative FEV1 and VC were predicted by the formula; Postoperative FEV1 [VC]=Preoperative FEV1 [VC] x percent function of regions of lung not to be resected. In this study, I concluded that perfusion lung scanning is a simple and useful method to predict postoperative ventilatory function after pneumonectomy of lobectomy.

  • PDF

Venture Capital Syndicate Diversity: Three Types and their Effects on Performance (벤처 캐피탈 신디케이트의 다양성: 세 가지 범주와 성과에 미치는 영향)

  • Shin, Sang Yoon
    • The Journal of Small Business Innovation
    • /
    • v.21 no.1
    • /
    • pp.43-59
    • /
    • 2018
  • This study investigates the relationship between venture capital (hereafter, VC) syndicate diversity and the IPO performance of an entrepreneurial company backed by the syndicate. Specifically, focusing on three types of diversity within a VC syndicate, which are aligned with Harrison and Klein's seminal categorization in 2007 (i.e., separation, variety, and disparity), this study suggests their distinct effects on performance. Two stage least square analyses with 1,127 VC syndicate investments made by 6,268 VC firms strongly supported the hypotheses. The results showed that that capacity diversity decreases the performance and that expertise diversity and network diversity increase it.

  • PDF

Protective effects and mechanism of coenzyme Q10 and vitamin C on doxorubicin-induced gastric mucosal injury and effects of intestinal flora

  • Zhao, Xiaomeng;Feng, Xueke;Ye, Nan;Wei, Panpan;Zhang, Zhanwei;Lu, Wenyu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.4
    • /
    • pp.261-272
    • /
    • 2021
  • Doxorubicin (Dox) is widely used to the treatment of cancer, however, it could cause damage to gastric mucosa. To investigate the protective effects and related mechanisms of coenzyme Q10 (CoQ10) and vitamin C (VC) on Dox-induced gastric mucosal injury, we presented the survey of the 4 groups of the rats with different conditions. The results showed Dox treatment significantly induced GES-1 apoptosis, but preconditioning in GES-1 cells with VC or CoQ10 significantly inhibited the Dox-induced decrease and other harm effects, including the expression and of IκKβ, IκBα, NF-κB/p65 and tumor necrosis factor (TNF-α) in GES-1 cells. Moreover, high-throughput sequencing results showed Dox treatment increased the number of harmful gut microbes, and CoQ10 and VC treatment inhibited this effect. CoQ10 and VC treatment inhibits Dox-induced gastric mucosal injury by inhibiting the activation of the IkKB/IκBα/NF-κB/p65/TNF-α pathway, promoting anti-inflammatory effects of gastric tissue and regulating the composition of the intestinal flora.

Synthesis and Characterization of Vanadium(Ⅲ) Complexes with N, P, O-donating Ligands(Ⅱ) (질소, 산소, 인 주개 리간드를 갖는 바나듐(Ⅲ) 착물의 합성과 특성 (제 2 보))

  • Oh Sang-Oh;Lyou Eun-Young
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.612-617
    • /
    • 1993
  • Some vanadium(III) complexes have been prepared from the reaction of VC$l_3$ with N, P, O-donating ligands and characterized by elemental analysis, $^1$H-NMR infrared and UV-Visible spectroscopy. 3,5-Lutidine, 1,2-phenylenediamine, 8-hydroxyquinoline, 9,10-phenanthrenequinone, triphenylphosphine, 1,2-bis(diphenylphosphino)ethane, 1,3-bis(diphenylphosphino)propane and 1,1'-bis(diphenylphosphino)ferrocene were chosen as coordinating ligands. Stretching frequency ${\nu}g$(V-Cl) of complexes appears) at 298∼367 cm-1, which show octahedral geometries. Stretching frequency of ${\nu}g$(V-X) (X = N, P, O) indicates that ligands are coordinated to vanadium(III). Stretching frequency ${\nu}g(C{\equiv}N)$ of acetonitrile in these complexes are characteristically shifted to about 70 c$m^{-1}$ higher compared with that of a free ligand (2260 c$m^{-1}$). Bending frequency of $\delta(C{\equiv}N)$ is also shifted to about 60 c$m^{-1}$ higher compared with that of a free ligand (377 c$m^{-1}$). Finally each vanadium(III) complex showed the following formulation; [VC$l_3$(L)$_2$MeCN] or [VC$l_3$(L-L)MeCN].

  • PDF

Anaerobic Degradation of cis-1,2-Dichloroethylene by Cultures Enriched from a Landfill Leachate Sediment

  • Chang, Young-Cheol;Jung, KwEon;Yoo, Young-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.3
    • /
    • pp.366-372
    • /
    • 2003
  • The production of microbiologically enriched cultures that degrade cis- 1,2-dichloroethylene(DCE) under anaerobic conditions was investigated. Among 80 environmental samples, 19 displayed significant degradation of $10{\mu}M$ cis-DCE during 1 month of anaerobic incubation, and one sediment sample collected at a landfill area (Nanji-do, Seoul, Korea) showed the greatest degradation ($94\%$). When this sediment culture was subcultured repeatedly, the ability to degrade cis-DCE gradually decreased. However, under Fe(III)-reducing conditions, cis-DCE degradation by the subculture was found to be maintained effectively. In the Fe(III)-reducing subculture, vinyl chloride (VC) was also degraded at the same extent as cis-DCE No accumulation of VC during the cis-DCE degradation was observed. Thus, Fe(III)-reducing microbes might be involved in the anaerobic degradation of the chlorinated ethenes. However, the subcultures established with Fe(III) could function even in the absence of Fe(III), showing that the degradation of cis-DCE and VC was not directly coupled with the Fe(III) reduction. Consequently, the two series of enrichment cultures could not be obtained that degrade both cis-DCE and VC in the presence or absence of Fe(III). Considering the lack of VC accumulation, both cultures reported herein may involve interesting mechanism(s) for the microbial remediation of environments contaminated with chlorinated ethenes. A number of fermentative reducers (microbes) which are known to reduce Fe(III) during their anaerobic growth are potential candidates involved in cir-DCE degradation in the presence and absence of Fe(III).

The Study on Miniaturization and Weight Reduction of Auxiliary Power Unit in Magnetic Levitation Train

  • Lee, Na Ri;Shin, Hee Keun;Choi, Sung Ho;Kim, Ju Bum;Lim, Jae Won;Park, Doh Young;Mok, Hyung Soo
    • International Journal of Railway
    • /
    • v.8 no.1
    • /
    • pp.10-14
    • /
    • 2015
  • Due to the characteristics of the vehicle structure, the magnetic levitation train has a confined bottom space thus a study on miniaturization and weight reduction of auxiliary power unit is essential. This auxiliary power unit is an essential device used for illumination, air conditioning, heating and air brake equipment excluding the motor. The previous auxiliary power unit for magnetic levitation train has used the hard switching having a high switching frequency with heavy loss in order to reduce the size of filter reactor and transformer but the reduction in volume was not significant. In this paper, by reducing the loss, reducing the size of the cooling unit and by increasing the switching frequency using the soft switching of resonant converter, it has miniaturized and reduced the weight of filter reactor and transformer which occupy significant space in the auxiliary power unit. This study has verified the performance of 50KVA grade prototype through simulated interpretation and analysis, and compared the size and weight of auxiliary power unit of the previous magnetic levitation train.

Determination of In-focus Criteria In Image Processing Method for Particle Size Measurement (입경측정을 위한 영상처리기법에서 입자 초점면 존재 판단 기준의 설정)

  • Koh, Kwang Uoong;Kim, Joo Youn;Lee, Sang Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.3
    • /
    • pp.398-407
    • /
    • 1999
  • In the present image processing technique, the concept of the gradient indicator(GI) has been introduced to find out the depth-of-field in sizing large particles ranging from $30{\mu}m$ to $30{\mu}m$ where using of the concept of the normalized contrast value(VC) is not appropriate. The gradient indicator is defined as the ratio of the local value to the maximum possible value of the gray-level gradient in an image frame. The gradient indicator decreases with the increases of the particle size and the distance from the exact focal plane. A particle is considered to be in focus when the value of the gradient indicator at its image boundary stays above a critical value. This critical gradient indicator($GI_{critical}$) is defined as the maximum gradient indicator($GI_{max}$) subtracted by a constant ${\Delta}GI$ which is to account for the particle-size effect. In the present ca.so, the value of ${\Delta}GI$ was set to 0.28 to keep the standard deviation of the measured particles mostly within 0.1. It was also confirmed that, to find the depth-of-field for small particles(${\leq}30{\mu}m$) with the same measurement accuracy, tho concept of the critical normalized contrast($VC_{critical}$) is applicable with 85% of the maximum normalized contrast value($VC_{max}$). Finally, the depth-of-field was checked for the size range between $10{\mu}m$ and $300{\mu}m$ when the both in-focus criteria ($GI_{critical}$ and $VC_{critical}$) were adopted. The change of the depth-of-field with the particle size shows good linearity in both the VC-applicable and the GI-applicable ranges with a reasonable accuracy.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Effect of Grain Growth Inhibitor on Sintering of Nanophase WC-10wt%Co (초미립 WC-l0wt%Co 초경 분말의 소결시 입자 성장 억제제 첨가 효과 연구)

  • 김병기
    • Journal of Powder Materials
    • /
    • v.1 no.2
    • /
    • pp.208-216
    • /
    • 1994
  • A radically new approach to the in situ synthesis of the consituent phases of a composite structure has enabled the production of a new WC/Co materials with an ultrafine microstructure. The process for synthesizing nanophase WC/Co powders consists of spray drying from solution to form a homogeneous precursor powder, and thermochemical conversion of the precursor powder to the nanophase WC/Co powder. Near theoretical density of pure nanophase WC-10 wt%Co has been obtained in only 30 sec at 140$0^{\circ}C$. But WC particles were grown up very rapidly with longer sintering time to get full density. To overcome coarsening of WC particle during sintering, VC, TaC and VC/TaC were used as the grain growth inhibitor with different amount respectively. VC/TaC doped WC-10 wt%Co was shown superior hardness and TRS and microstructure was maintained ultrafine scale (average WC size is less than 0.1 ${\mu}{\textrm}{m}$).

  • PDF