• Title/Summary/Keyword: V2X

Search Result 3,743, Processing Time 0.05 seconds

Regulatory Mechanism of Radiation-induced Cancer Cell Death by the Change of Cell Cycle (세포주기 변화에 타른 방사선 유도 암세포 사망의 조절기전)

  • Jeong Soo-Jin;Jeong Min-Ho;Jang Ji-Yeon;Jo Wol-Soon;Nam Byung-Hyouk;Jeong Min-Za;Lim Young-Jin;Jang Byung Gon;Youn Seon-Min;Lee Hyung Sik;Hur Won Joo;Yang Kwang Mo
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.306-314
    • /
    • 2003
  • Purpose : In our Previous study, we have shown the main cel1 death pattern Induced by irradiation or protein tyrosine kinase (PTK) inhibitors in K562 human myeiogenous leukemic cell line. Death of the cells treated with irradiation alone was characterized by mitotic catastrophe and typical radiation-induced apoptosis was accelerated by herblmycin A (HMA). Both types of cell death were inhibited by genistein. In this study, we investigated the effects of HMA and genistein on cell cycle regulation and its correlation with the alterations of radiation-induced cell death. Materials and Methods: K562 cells In exponential growth phase were used for this study. The cells were Irradiated with 10 Gy using 6 MeV Linac (200-300 cGy/min). Immediately after irradiation, cells were treated with 250 nM of HMA or 25 $\mu$N of genistein. The distributions of cell cycle, the expressions of cell cycle-related protein, the activities of cyclin-dependent kinase, and the yield of senescence and differentiation were analyzed. Results: X-irradiated cells were arrested In the G2 phase of the cell cycle but unlike the p53-positive cells, they were not able to sustain the cell cycle arrest. An accumulation of cells in G2 phase of first ceil-cycle post-treatment and an increase of cyclin Bl were correlated with spontaneous, premature, chromosome condensation and mitotic catastrophe. HMA induced rapid G2 checkpoint abrogation and concomitant p53-independent Gl accumulation. HMA-induced cell cycle modifications correlated with the increase of CDK2 kinase activity, the decrease of the expressions of cyclins I and A and of CDK2 kinase activity, and the enhancement of radiation-induced apoptosis. Genistein maintained cells that were arrested in the G2-phase, decreased the expressions of cyclin Bl and cdc25c and cdc25C kinase activity, increased the expression of pl6, and sustained senescence and megakaryocytic differentiation. Conclusion: The effects of HMA and genistein on the radiation-induced cell death of KS62 cells were closely related to the cell cycle regulatory activities. In this study, we present a unique and reproducible model in which for investigating the mechanisms of various, radiation-induced, cancer cell death patterns. Further evaluation by using this model will provide a potent target for a new strategy of radiotherapy.

Similarities of Scaritoxin to Ciguatoxin on the Chromatographic Behaviours (Scaritoxin과 Ciguatoxin의 크로마토그라피상에서의 몇가지 유사성)

  • Joh, Yong-Goe;Scheuer, Paul J.
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 1985
  • In studying the structural work on ciguatoxin, parrot fish collected were identified as Scarus sordidus, S. frenatus, S. scaber and S. pectarlis, in which only S. sordidus contained toxic materials. Crude toxins obtained by silicic acid column chromatography, could be separated on a DEAE-cellulose column into two fractions, ST-1(less polar) and ST-2(polar) eluted with chloroform and chloroform-methanol(1:1). Furthermore ST-1 could be changed into ST-2 by repeated chromatography on DEAE-cellulose. Rf values of ST-1 and ST-2 were 0.60-0.75 and 0.30-0.54 on TLC coated with silica gel 60F-254 developed by chloroform-methanol-water-acetic acid (90:9.5:0.2:0.3) mixture. The peaks of ST-1 and ST-2 were not observed on each HPLC chromatogram at low sensitivity(2X), but by bioassay they were detected in the fraction of 24-27ml(less polar toxin, 120ng) and 22-27 ml (polar toxin, 150 ng). Less polar ciguatoxin from morey eel viscera also showed its peak in the same elution volume(25ml). Being subjected to chromatography on basic aluminum oxide (activity grade I) or to alkaline treatment, followed by basic aluminum oxide (activity grade I) chromatography ST-1 toxin was remarkably converted into the polar toxic component supposed to be polar ciguatoxin in both cases. In the latter case, approximately 74% of the residual toxicity was changed into the polar component, accompanied by about 50% loss of the initial toxicity. More than 26% of ST-2 toxicity was transformed into the less polar toxic component supposed to be less polar ciguatoxin on a deactivated aluminum oxide (activity grade V) column.

  • PDF

THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS (타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화)

  • Hwang Yun-Tae;Lee Sung-Bok;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

Radiation-Induced Apoptosis of Lymphocytes in Peripheral Blood (말초혈액 내 림프구의 방사선에 의한 아포프토시스)

  • Oh, Yoon-Kyeong;Lee, Tae-Bum;Nam, Taek-Keun;Kee, Keun-Hong;Choi, Cheol-Hee
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • Purpose : This study quantitatively evaluated the apoptosis In human peripheral blood lymphocytes using flow cytometry, and investigated the possibility of using this method, with a small amount of blood, and the time and dose dependence of radiation-induced apoptosls. Materials and Methods : Peripheral blood lymphocyes were isolated from the heparinized venous blood of 11 healthy volunteers, 8 men and 3 women, with each 10 ml of blood being divided Into IS samples. The blood lymphocytes were Irradiated using a linear accelerator at a dose rate of 2.4 Gy/min, to deliver doses of 0.5, 1, 2 and S Gy. The control samples, and Irradiated cells, were maintained in culture medium for 24, 48 and 72 hours fellowing the Irradiation. The number of apoptotic cells after the in vitro X-irradiation was measured by flow cytometry after Incubation periods of 24, 48 and 72 hours. We also observed the apoptotic cells using a DNA fragmentation assay and electron microscopy. Results : The rate oi spontaneous apoptosis increased in relation to the time interval following irradiation (1.761 ${\pm}$0.161, 3.563${\pm}$0.554, 11.098${\pm}$2.849, at 24, 48, and 72 hours). The apoptotli cells also increased In the samples irradiated with 0.5, 1, 2 and 5 Gy, In a radiation dose and time interval after Irradiation manner, with the apoptosls being too great at 72 hours after Irradiation. The dose-response curves were characterized by an Initial steep Increase In the number of apoptotic cells for Irradiation doses below 2 Gy, with a flattening of the curves as the dose approached towards 5 Gy. Conclusion :The flow cytometric assay technique yielded adequate data, and required less than 1 mL of blood. The time and dose dependence of the radiation-induced apoptosis, was also shown. It is suggested that the adequate time Interval required for the evaluation of apoptosis would be 24 to 48 hours after blood sampling.

Effect of starch extraction solutions on extraction and physicochemical property of Chinese yam (Dioscorea batatas) starch (마(Dioscorea batatas) 전분의 추출 및 물리화학적 특성에 대한 전분추출용액의 영향)

  • Lee, Hyunjeong;Seo, Dong-Ho;Kim, Hyun-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.2
    • /
    • pp.191-197
    • /
    • 2018
  • This study investigated the influence of starch extraction (ST-EX) solutions on the extraction yield and characteristics of Chinese yam (CY) starches from domestic Dioscorea batatas. Ascorbic acid (VitC), $Na_2S_2O_3$, $NaHCO_3$, and $Na_2CO_3$ were used as ST-EX solutions (0.4%, w/v). The extracted CY starches were examined for ST-EX yield, chemical composition, size distribution, X-ray diffraction, solubility, swelling power, gelatinization, and pasting viscosity. The highest ST-EX yield was obtained from $NaHCO_3$, followed by VitC. Lower protein content, relative crystallinity, and gelatinization enthalpy were found in CY starches from alkaline ST-EX solutions ($NaHCO_3$ and $Na_2CO_3$). Size distribution and gelatinization temperature did not generally differ for CY starches from the different ST-EX solutions. Pasting viscosities increased in the order from $Na_2CO_3$ > $Na_2S_2O_3$ > $NaHCO_3$ > VitC ST-EX solutions. Thus, VitC may be most appropriate to extract CY starch from Dioscorea rhizomes, considering its ST-EX yield, total starch content, and variation in pasting viscosity.

Scolytidae, Platypodidae, Bostrichidae and Lyctidae Intercepted from Imported Timbers at Busan Port Entry (부산항의 수입재에서 검출된 나무좀과, 긴나무좀과, 개나무좀과 및 가루나무좀과의 종류)

  • 최은정;추호렬;이동운;이상명;박종균
    • Korean journal of applied entomology
    • /
    • v.42 no.3
    • /
    • pp.173-184
    • /
    • 2003
  • Beetles belonging to the families Scolytidae, Platypodidae, Bostrichidae, and Lyctidae intercepted from imported timbers at Busan port were investigated from March 1 to November 30 in 2000. In addition, hosts imported country were examined. A total of 52 species of within 23 genera was intercepted from nineteen species of timbers or logs from fifteen countries. In Scolytidae, 35 species of 16 genera in three subfamilies were identified 12 species in Xyleborus, 6 species in Ips, 3 species in Trypodendron, 2 species in Arixyleborus, and 12 species of all different genera including Alinphagous. Scolytidae were intercepted from 16 species of timbers in 13 genera imported from 11 countries. The highest beetles were intercepted from Malaysian lauan. In Platypodidae, 9 species of one genus (Platypus) were intercepted from 6 species of timbers in 4 genera imported from 6 countries including Australia. The highest numbers were intercepted from Malysian lauan. In Bostrychidae, 5 species of 4 genera in two subfamilies were intercepted from 6 species of timbers in 4 genera imported from four countries. In Lyctidae, Trogoxylon sp., Minthea sp., and Minthea rugicollis were intercepted from 3 species of timbers in 2 genera imported from 3 countries.

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

Chest CT Findings of COVID-19 Patients with Mild Clinical Symptoms at a Single Hospital in Korea (경증의 임상 소견을 보이는 COVID-19 환자들의 흉부 CT 소견)

  • Woon Young Baek;Young Kyung Lee;Suhyun Kim;Chorom Hahm;Mi Young Ahn;Dong Hyun Oh;Jae-Phil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.139-151
    • /
    • 2021
  • Purpose To retrospectively evaluate the chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in patients with mild clinical symptoms at a single hospital in South Korea. Materials and Methods CT scans of 87 COVID-19 patients [43 men and 44 women; median age: 41 years (interquartile range: 26.1-51.0 years)] with mild clinical symptoms (fever < 38℃ and no dyspnea) were evaluated. Results CT findings were normal in 39 (44.8%) and abnormal in 48 (55.2%) patients. Among the 48 patients with lung opacities, 17 (35.4%) had unilateral disease and 31 (64.6%) had bilateral disease. One (2.1%) patient showed subpleural distribution, 9 (18.8%) showed peribronchovascular distribution, and 38 (79.2%) showed subpleural and peribronchovascular distributions. Twenty-two (45.8%) patients had pure ground-glass opacities (GGOs) with no consolidation, 17 (35.4%) had mixed opacities dominated by GGOs, and 9 (18.8%) had mixed opacities dominated by consolidation. No patients demonstrated consolidation without GGOs. Conclusion The most common CT finding of COVID-19 in patients with mild clinical symptoms was bilateral multiple GGO-dominant lesions with subpleural and peribronchovascular distribution and lower lung predilection. The initial chest CT of almost half of COVID-19 patients with mild clinical symptoms showed no lung parenchymal lesions. Compared to relatively severe cases, mild cases were more likely to manifest as unilateral disease with pure GGOs or GGO-dominant mixed opacities and less likely to show air bronchogram.

Investigation of Study Items for the Patterns of Care Study in the Radiotherapy of Laryngeal Cancer: Preliminary Results (후두암의 방사선치료 Patterns of Care Study를 위한 프로그램 항목 개발: 예비 결과)

  • Chung Woong-Ki;Kim I1-Han;Ahn Sung-Ja;Nam Taek-Keun;Oh Yoon-Kyeong;Song Ju-Young;Nah Byung-Sik;Chung Gyung-Ai;Kwon Hyoung-Cheol;Kim Jung-Soo;Kim Soo-Kon;Kang Jeong-Ku
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.299-305
    • /
    • 2003
  • Purpose: In order to develop the national guide-lines for the standardization of radiotherapy we are planning to establish a web-based, on-line data-base system for laryngeal cancer. As a first step this study was performed to accumulate the basic clinical information of laryngeal cancer and to determine the items needed for the data-base system. Materials and Methods: We analyzed the clinical data on patients who were treated under the diagnosis of laryngeal cancer from January 1998 through December 1999 In the South-west area of Korea. Eligiblity criteria of the patients are as follows: 18 years or older, currently diagnosed with primary epithelial carcinoma of larynx, and no history of previous treatments for another cancers and the other laryngeal diseases. The items were developed and filled out by radiation oncologlst who are members of forean Southwest Radiation Oncology Group. SPSS vl0.0 software was used for statistical analysis. Results: Data of forty-five patients were collected. Age distribution of patients ranged from 28 to 88 years(median, 61). Laryngeal cancer occurred predominantly In males (10 : 1 sex ratio). Twenty-eight patients (62$\%$) had primary cancers in the glottis and 17 (38$\%$) in the supraglottis. Most of them were diagnosed pathologically as squamous cell carcinoma (44/45, 98$\%$). Twenty-four of 28 glottic cancer patients (86$\%$) had AJCC (American Joint Committee on Cancer) stage I/II, but 50$\%$ (8/16) had In supraglottic cancer patients (p=0.02). Most patients(89$\%$) had the symptom of hoarseness. indirect laryngoscopy was done in all patients and direct laryngoscopy was peformed in 43 (98$\%$) patients. Twenty-one of 28 (75$\%$) glottic cancer cases and 6 of 17 (35$\%$) supraglottic cancer cases were treated with radiation alone, respectively. The combined treatment of surgery and radiation was used in 5 (18$\%$) glottic and 8 (47$\%$) supraglottic patients. Chemotherapy and radiation was used in 2 (7$\%$) glottic and 3 (18$\%$) supraglottic patients. There was no statistically significant difference in the use of combined modality treatments between glottic and supraglottic cancers (p=0.20). In all patients, 6 MV X-ray was used with conventional fractionation. The iraction size was 2 Gy In 80$\%$ of glottic cancer patients compared with 1.8 Gy in 59$\%$ of the patients with supraglottic cancers. The mean total dose delivered to primary lesions were 65.98 ey and 70.15 Gy in glottic and supraglottic patients treated, respectively, with radiation alone. Based on the collected data, 12 modules with 90 items were developed or the study of the patterns of care In laryngeal cancer. Conclusion: The study Items for laryngeal cancer were developed. In the near future, a web system will be established based on the Items Investigated, and then a nation-wide analysis on laryngeal cancer will be processed for the standardization and optimization of radlotherapy.

Evaluation the Output Dose of Linear Accelerator Photon Beams by Blind Test with Dose Characteristics of LiF:Mg,Cu,P TLD (LiF:Mg,Cu,P 열형광선량계의 선량특성을 이용한 눈가림법에 의한 출력선량 평가)

  • Choi, Tae-Jin;Lee, Ho-Joon;Yie, Ji-Won;Oh, Young-Gi;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.308-316
    • /
    • 2009
  • To achieve the accurate evaluation of given absorbed dose from output dose of linear accelerator photon beam through investigate the characteristics of LiF:Mg,Cu,P TLD powder. This experimental TL phosphor is performed with a commercial LiF:Mg,Cu,P powder (Supplied by PTW) and TL reader (LTM, France). The TLD was exposed to 6 MV X rays of linear accelerator photon beam with range 15 to 800 cGy in blind dose at two hospitals. The dose evaluation of TLD was through the experimental algorithms which were dose dependency, dose rate dependency, fading and powder weight dependency. The glow curve has shown the three peaks which are 110, 183 and 232 degrees of heating temperature and the main dosimetric peak showed highest TL response at 232 high temperature. In this experiments, the LiF:Mg,Cu,P phosphor has shown the 2.5 eV of electron trap energy with a second order. This experiments guided the dose evaluation accuracy is within 1% +2.58% of discrepancy. The TLD powder of LiF:Mg,Cu,P was analyzed to dosimetric characterists of electron captured energy and order by glow shape, and dose-TL response curve guided the accuracy within 1.0+2.58% of output dose discrepancy.

  • PDF