• Title/Summary/Keyword: V2I

Search Result 5,336, Processing Time 0.044 seconds

Hard TiN Coating by Magnetron-ICP P $I^3$D

  • Nikiforov, S.A.;Kim, G.H.;Rim, G.H.;Urm, K.W.;Lee, S.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.414-420
    • /
    • 2001
  • A 30-kV plasma immersion ion implantation setup (P $I^3$) has been equipped with a self-developed 6'-magnetron to perform hard coatings with enhanced adhesion by P $I^3$D(P $I^3$ assisted deposition) process. Using ICP source with immersed Ti antenna and reactive magnetron sputtering of Ti target in $N_2$/Ar ambient gas mixture, the TiN films were prepared on Si substrates at different pulse bias and ion-to-atom arrival ratio ( $J_{i}$ $J_{Me}$ ). Prior to TiN film formation the nitrogen implantation was performed followed by deposition of Ti buffer layer under A $r^{+}$ irradiation. Films grown at $J_{i}$ $J_{Me}$ =0.003 and $V_{pulse}$=-20kV showed columnar grain morphology and (200) preferred orientation while those prepared at $J_{i}$ $J_{Me}$ =0.08 and $V_{pulse}$=-5 kV had dense and eqiaxed structure with (111) and (220) main peaks. X-ray diffraction patterns revealed some amount of $Ti_{x}$ $N_{y}$ in the films. The maximum microhardness of $H_{v}$ =35 GN/ $M^2$ was at the pulse bias of -5 kV. The P $I^3$D technique was applied to enhance wear properties of commercial tools of HSS (SKH51) and WC-Co alloy (P30). The specimens were 25-kV PII nitrogen implanted to the dose 4.10$^{17}$ c $m^{-2}$ and then coated with 4-$\mu\textrm{m}$ TiN film on $Ti_{x}$ $N_{y}$ buffer layer. Wear resistance was compared by measuring weight loss under sliding test (6-mm $Al_2$ $O_3$ counter ball, 500-gf applied load). After 30000 cycles at 500 rpm the untreated P30 specimen lost 3.10$^{-4}$ g, and HSS specimens lost 9.10$^{-4}$ g after 40000 cycles while quite zero losses were demonstrated by TiN coated specimens.s.

  • PDF

A Computation Reduction Technique of MUSIC Algorithm for Optimal Path Tracking (최적경로 추적을 위한 MUSIC 알고리즘의 계산량 감소 기법)

  • Kim, Yongguk;Park, Hae-Guy;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.4
    • /
    • pp.188-194
    • /
    • 2014
  • V2I(Vehicular to Infrastructure) is a one kind of communication systems which is used between the base stations and mobile objects. In V2I communication system, it is difficult to obtain the desired communication performance. Beamforming technology is to find the optimal path. and it can be improved the communication performance. MUSIC algorithm can be estimated the direction of arrival. The directional vector of received signals and the eigenvector has orthogonal property. MUSIC algorithm uses this property. In V2I communication environment, real time optimal path is changed. By the high computational complexity of the MUSIC algorithm, the optimal path estimation error is generated. In this paper, we propose a method of computation reduction algorithm for MUSIC algorithm.

Response of broilers to supplementation of branched-chain amino acids blends with different valine contents in the starter period under summer conditions

  • Kop-Bozbay, Canan;Akdag, Ahmet;Atan, Helin;Ocak, Nuh
    • Animal Bioscience
    • /
    • v.34 no.2
    • /
    • pp.295-305
    • /
    • 2021
  • Objective: The objectives of this study were to compare the effects of normal and low protein content (PC) of starter diet supplemented or not with blends of branched-chain amino acids (BCAAs) on growth performance of broilers under summer conditions and to investigate whether these effects altered some quality traits and the characteristics of gastrointestinal tract. Methods: A total of 768 mixed-sex broiler chicks (Ross 308, one-d-old) with an average initial body weight (BW) of 47.6±1.03 g were allocated into six treatments with four replications in 2×3 factorial arrangement. Factors were: PC, normal (N, 22% to d 15); and low (L, 20% to d 15); and added BCAA blends, L-leucine, L-isoleucine, and L-valine at zero (0L:0I:0V); 1.0, 0.25, and 0.25 (4L:1I:1V); or 1.0, 0.25, 0.75 (4L:1I:3V) g/kg of diet. Hence, six dietary treatments were named as N0L:0I:0V, N4L:1I:1V, N4L:1I:3V, L0L:0I:0V, L4L:1I:1V, and L4L:1I:3V. Average indoor temperature and humidity were 32.8℃±1.7℃ and 61.1%±4.12%, respectively. Results: BW, feed conversion ratio (FCR) and carcass weight were not affected by PC, BCCA and their interaction (p>0.05). The L diets decreased the water holding capacity of the breast (p = 0.002) and thigh (p = 0.050) meats and dressing percentage (p = 0.005) compared to the N diets. The 4L:1I:1V diet decreased breast yield compared to the 0L:0I:0V diets (p = 0.041). The effect of PC on feed intake, mortality and gastrointestinal trait weight were depended on the L:I:V ratios under summer conditions due to interactions between factors (p<0.05). The FI and mortality of L4L:1I:1V broilers were lower than those of N4L:1I:1V birds (p<0.05). Conclusion: It was concluded that the blends of BCAAs used failed to improve performance and to promote breast yields, because diets with normal or with reduced protein supplemented or not with BCAAs up to d 15 produced a similar BW and FCR in broilers raised in hot-climate conditions.

Reduced RSU-dependency Authentication Protocol to Enhance Vehicle Privacy in VANET (VANET에서 RSU의 의존성을 줄이고 차량의 프라이버시를 강화한 인증 프로토콜)

  • Rhim, Won-Woo;Kim, Jong-Sik;Kim, Sang-Jin;Oh, Hee-Kuck
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.6
    • /
    • pp.21-34
    • /
    • 2011
  • VANET offers variety of services to allow safe and comfortable driving through V2V and V2I communications in transportation systems. To use these services, safe and reliable V2V and V2I communications must be guaranteed. In this regards, many RSU-based studies have been carried out to meet certain issues such as: efficiency of frequent communication between RSU and vehicles, security of stored information in RSU, and invasion on vehicle's privacy. In this paper, a scheme is proposed to reduce the dependency on RSU and to enhance the vehicle privacy by using signature-based authentication protocol. The proposed protocol is more efficient than existing protocol with group signature, and satisfies all the requirements of VANET.

An Analytical DC Model for HEMT's (헴트 소자의 해석적 직류 모델)

  • Kim, Young-Min
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.38-47
    • /
    • 1989
  • A purely analytical model for HEMT's based on a two dimensional charge control simul-ation[4] is proposed. In this model proper treatment of diffusion effect of electron transport along a 2-DEG (two dimensional electron gas) channel is perfoemed. This diffusion effect is shown to effectively increase the bulk mibility and threshold voltage of the I-V curves compared to the existing models. The channel thickness and gate capacitance are expressed as functions of gate voltages covering subthreshold characteristics of HEMT's analytically. By introducing the finite channel opening and an effiective channel-length modulation, the solpe of the saturation region of the I-V curves ws modeled. The smooth transition of the I-V curves at linear-to-saturation regions of the I-V curves was possible using the continuous Troffimenkoff-type of field dependent mobility. Furthermore, a correction factor f was introduced to account for the finite transition section forming between a GCA and a saturated section. This factor removes large discrepancies in the saturation region of the I-V curve predicted by existing l-dimensional models.

  • PDF

Fabrication and Test of a $HgI_2$ Gamma Ray Detector (감마선 검출용 $HgI_2$ 소자 제작 및 특성 평가)

  • Choi, Myung-Jin;Lee, Hong-Kyu;Kang, Young-Il;Lim, Ho-Jin;Choi, Seung-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 1991
  • The $HgI_2$ single crystal which can be used for the ${\gamma}-ray$ detector at room temperature was grown by Temperature Oscillation Method. The low temperature photoluminescence, specific resistivity and trap concentration of $HgI_2$ single crystal were investigated. Three main luminescence bands were observed at 2.30eV, 2.20eV and 2.00eV at 20K, related to the excitons, I-vacancies and impurities, respectively. The specific resistivity and trap concentration of $HgI_2$ single crystal were $10^{11}{\Omega}\;cm\;and\;1.8{\times}10^{14}/cm^3$ at room temperature, respectively. Also the radiation detecting system was deviced by $HgI_2$ ${\gamma}-ray$ detector, one chip microprocessor, LCD module and personal computer. The prepared $HgI_2$ ${\gamma}-ray$ detector showed a good linearity of ${\gamma}-radiation$ dose for standard ${\gamma}-ray$.

  • PDF

Changes of Surface Electromyography on Frontalis Muscle during Electro-Acupuncture Stimulation of Abdomen or Legs - A Pilot Study for Clinical Approach to Autonomic Nervous System Changes - (복부 및 사지 부위의 전기침 자극이 전두근에서 측정한 SEMG 변화에 미치는 영향 - 자율신경계의 변화에 대한 임상적 접근을 위한 사전 연구 -)

  • Je, Jun-Tae;Choi, San-Ho;Shin, Sun-Ho;Lim, Jin-Young;Lee, Sang-Kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.14-25
    • /
    • 2012
  • Objectives : To observe physiological changes during clinical acupuncture treatment. Methods : We recruited 40 healthy volunteers who had experienced an acupuncture treatment at least once within the past three years. The experimental group was divided into four groups according to the needling site and frequency of electrical stimulation. Sites consisted of abdomen and legs. Frequencies consisted of 100 Hz and 2 Hz. The procedures of experimental treatment consisted of seven phases, Resting I phase (Resting I), Needle insertion phase (Insertion), Maintenance of needle insertion I phase (Maintain I), Electrical stimulation phase (ES), Maintenance of needle insertion II phase (Maintain II), Needle removal phase (Removal) and Resting II phase (Resting II). We measured the surface electromygraphy (SEMG) through an electrode on the frontalis muscle during all phases consecutively. Results : When SEMGs of all seven phases were analyzed, they significantly increased or decreased according to phases. SEMGs of Insertion, Maintain I, ES and Maintain II phase significantly increased more than RestingI in abdomen and legs groups. SEMGs of the abdomen group were measured as being $4.78{\pm}0.74{\mu}V$ on Resting I, $16.48{\pm}3.97{\mu}V$ on Insertion, $46.31{\pm}10.56{\mu}V$ on Maintain I, $45.88{\pm}9.72{\mu}V$ on ES, $45.56{\pm}9.69{\mu}V$ on Maintain II, $18.76{\pm}3.05{\mu}V$ on Removal, and $3.75{\pm}0.65{\mu}V$ on Resting II. SEMGs of the legs group were measured as being $3.34{\pm}0.35{\mu}V$ on Resting I, $12.11{\pm}1.76{\mu}V$ on Insertion, $36.74{\pm}6.99{\mu}V$ on Maintain I, $33.57{\pm}6.30{\mu}V$ on ES, $32.66{\pm}6.03{\mu}V$ on Maintain II, $14.08{\pm}2.15{\mu}V$ on Removal, and $2.88{\pm}0.32{\mu}V$ on Resting II. Conclusions : SEMG changed differently according to processes of acupuncture. Electrical stimulation showed different change of SEMG. Thus, acupuncture treatment may change the status of the autonomic nervous system.

Operating characteristics of 3RT heat pumps

  • Moon, Chang-Uk;Choi, Kwang-Hwan;Yoon, Jung-In;Jeon, Min-Ju;Heo, Seong-Kwan;Sung, Yo-Han;Park, Sung-Hyeon;Lee, Jin-Kook;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.2
    • /
    • pp.140-145
    • /
    • 2017
  • Newly designed vapor-injection heat pumps have been proposed and analyzed in the present study. An economizer-type vapor-injection (V-I) system has been employed as the standard system because of its reliability and simple control method. The V-I system has a re-cooler and re-heater for cooling and heating, respectively. Solar panels have been installed in the V-I heat pump as well as in the re-heater in order to enhance heating capacity and performance. R410A has been employed as a working fluid and performance analysis has been conducted under various conditions. Results are summarized as follows: (1) The V-I system with the re-cooler yielded a marginally higher coefficient of performance (COP) than the conventional V-I refrigeration system. (2) By increasing the re-cooler cooling capacity, enhanced system performance as compared to the conventional V-I system was observed. (3) The re-heater negatively affected the system performance; hence, the V-I heat pump with the re-heater yielded a lower COP than that of the conventional V-I heat pump used for heating. (4) Although the solar panels increased the system performance, this increase could not offset performance degradation by the re-heater.

Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment (전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구)

  • Yang, Seungwoo;Han, Moojae;Shin, Yohan;Jung, Jaehoon;Choi, Yunseon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • In this study, it was intended to replace the existing plane parallel ionization chamber, which requires cross-calibration in electron beam treatment. The semiconductor compounds HgI2 was fabricated as detector, and the characteristics of HgI2 detector for the 6, 9 and 12 MeV electron beam was analyzed in the linear accelerator. It was also intended to evaluate the possibility of substitution with existing detectors and their applicability as electron beam dosimetry and to use them as a basic study of the development of electronic beam dosimeter. As a result of reproducibility, RSD was 0.4246%, 0.5054%, and 0.8640% at 6, 9, and 12 MeV energy, respectively, indicating that the output signal was stable. As a result of the linearity, the R2 was 0.9999 at 6 MeV, 0.9996 at 9 MeV, and 0.9997 at 12 MeV showed that the output signal is proportional to HgI2 as the dose is increased. The HgI2 detector of this study is highly applicable to electron beam measurement, and it may be used as a basic research on electron beam detection.

Carrier Lfetime and Anormal Cnduction Penomena in Silicon Epitaxial Layer-substrate Junction (Epitaxial에 의한 Si epi층의 케리어 수명과 P-N접합의 이상전도현상)

  • 성영권;민남기;김승배
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.83-89
    • /
    • 1977
  • This paper described the minority carrier lifetime in Si epitaxial layer, and also the voltage (V) versus current (I) characteristics of high resistivity Si epitaxial layer0substrate junction. The measured lifetime in Si epi-layer was much shorter than in bulk, and the temperature dependence of lifetime was found to agree well with Shockley-Read model of recombination which applies to high resistivity n-type materials. The V-I curve showed; an ohmic region (I.var.V), a sublinear region (I.var.V$^{1}$2/), a space charge limited current region (I.var.V$^{2}$), and finally a negative resistance region. We investigated these phenomena by the theory of the relaxation semiconductor.

  • PDF