• Title/Summary/Keyword: V2

Search Result 29,506, Processing Time 0.059 seconds

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Measuring Attitudes and Satisfaction Level towards Military Foodservices (군 급식소의 이용실태 및 만족도 조사)

  • Kang, Bo-Kyoung;Lee, Young-Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.1032-1042
    • /
    • 2011
  • The purpose of this study was to examine the attitudes and satisfaction level towards military foodservices as well as suggest effective ways to increase foodservice quality. A questionnaire survey was administered to 413 subjects, which included 400 soldiers and 13 foodservice managers. The survey period was from August 6 to August 25, 2008. The collected data were statistically treated using SPSS V12.0. Most of the investigated soldiers were 20~25 years old. The foodservice managers were male general officials and the majority of them had no prior food service training. None of the foodservice managers had a dietician certificate. Menu was planned through a local foodservice conference, and most food materials were delivered in the form of center-type and military unit-type. Deficiency and deterioration of food service facilities (28.6%) as well as deficiency in the number of cooking personnel (14.3%) increased the difficulty of operational management. Soldiers expressed a desire for increases in Western (25.7%) and Korean traditional foods (21.5%), which meant menu diversity. To increase the quality of military foodservices, taste of food (40.6%), increased portion size (30.4%), and improvement in hygienic conditions (13.6%) were demanded by the soldiers. Food taste (30.8%), improvement in hygienic conditions (23.1%), and better job management were all demanded by the foodservice managers. After factor analysis, quality attributes were rearranged into five dimensions, including facilities, food, menu, service, and sanitation most attributes were over 4 points out of 5 total in importance, but only 3 points in performance. The importance score was higher than the performance score. Soldiers' overall satisfaction level was on average 3.43 points out of 5 points.

Growth Inhibitory Effect of Kimchi Prepared with Four Year-Old Solar Salt and Topan Solar Salt on Cancer Cells (토판염 및 4년 숙성 천일염으로 제조한 김치의 암세포 성장 억제 효과)

  • Yoon, Hae-Hoon;Chang, Hae-Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.7
    • /
    • pp.935-941
    • /
    • 2011
  • The growth inhibitory effects of kimchi prepared with solar salt were investigated. Chinese cabbages were brined with purified salt, four year-old solar salt, and Topan solar salt, and then mixed with other ingredients. The final salt concentration was adjusted to 2.2~2.4% (w/v) for each salt, and the kimchi was fermented at $7^{\circ}C$. When the acidity reached around 0.5~0.6%, the kimchi was used as a sample for further experimentation. MTT assay was used to measure the growth inhibitory effect of kimchi extracts (water, methanol) on BJ human foreskin normal cells, AGS human gastric adenocarcinoma cells, and HT-29 human colon carcinoma cells. Water extracts of all the kimchi samples showed growth inhibitory effects on cancer cells; however, there was no significant difference among the used salts. Methanol extracts of all the kimchi samples showed higher growth inhibitory effects compared to the water extracts. The methanol extracts of four year-old solar salt kimchi (AGS: 73%, HT-29: 48%) and Topan solar salt kimchi (AGS: 62%, HT-29: 46%) showed higher growth inhibitory effects than that of purified salt kimchi (AGS: 52%, HT-29: 39%). In addition, morphological changes of cancer cells (AGS, HT-29) and decreased cell numbers were observed when methanol extract of four year-old solar salt kimchi was treated to AGS and HT-29 cells. However, none of the kimchi extracts showed any growth inhibitory effect on BJ normal cells.

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF

Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results (Structural Similarity Index 인자를 이용한 방사선 분할 조사간 환자 체위 변화의 자동화 검출능 평가: 초기 보고)

  • Youn, Hanbean;Jeon, Hosang;Lee, Jayeong;Lee, Juhye;Nam, Jiho;Park, Dahl;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.258-266
    • /
    • 2015
  • The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of high-definition. However, a rapid increase in patient's exposure and image information for CT image acquisition may be additional burden on the patient. In this study, by introducing structural similarity (SSIM) index that can effectively extract the structural information of the image, we analyze the differences between daily acquired x-ray images of a patient to verify the accuracy of patient positioning. First, for simulating a moving target, the spherical computational phantoms changing the sizes and positions were created to acquire projected images. Differences between the images were automatically detected and analyzed by extracting their SSIM values. In addition, as a clinical test, differences between daily acquired x-ray images of a patient for 12 days were detected in the same way. As a result, we confirmed that the SSIM index was changed in the range of 0.85~1 (0.006~1 when a region of interest (ROI) was applied) as the sizes or positions of the phantom changed. The SSIM was more sensitive to the change of the phantom when the ROI was limited to the phantom itself. In the clinical test, the daily change of patient positions was 0.799~0.853 in SSIM values, those well described differences among images. Therefore, we expect that SSIM index can provide an objective and quantitative technique to verify the patient position using simple x-ray images, instead of time and cost intensive three-dimensional x-ray images.

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

A Study on the Economic Analysis of Chestnut Prices and Production Forecasting (밤 가격(價格)의 경제분석(經濟分析) 및 생산예측(生産豫測)에 관(關)한 연구(硏究))

  • Song, Hyung Sop;Cho, Eung Hyouk
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.2
    • /
    • pp.263-271
    • /
    • 1987
  • The cyclical trend and seasonal variations of chestnut prices have been analyzed to find out the chestnut price fluctuation in Korea during 1966-1985. The optimum prices, production, and plantation area for the next twenty five years (1986-2010) have been forcasted by the derived equation models. The results of study can be summarized as follows: 1. The chestnut prices were increased by 14.67 percent per annum during 1966-1972, an d decreased by 9.24 percent during 1973-1985, due to the excessive production of chestnut. 2. The chestnut prices showed the lowest price during the harvesting season, especially in October (89.1), and highest in July (109.1). Seasonal fluctuation of chestnut prices were 0.0837 (C.V value) during 1966-1975, and 0.0706 during 1976-1985. Such a seasonal fluctuation of chestnut prices tends to be even with the passage of time. 3. The equation model of predicted chestnut prices was derived as follows : PR=117788.088 - 7.60 TC/Pop + 6.585 GNP/Pop The chestnut prices will be the lowest in 1988, but increased rapidly thereafter. 4. The equation model of optimum chestnut production was derived as follows : $${\ell}n\;PD/Pop=-8.5147-0.8267{\ell}n\;PR+3.3063{\ell}n\;GNP/Pop$$ To maintain optimum chestnut prices according to this model, chestnut production should be 133,000 ton for 1988, and 1,899,000 ton for 2010. 5. Optimum chestnut plantation area will be 4,000 ha in 1988, and thereafter total plantation area will be up to 57,400 ha in 2010.

  • PDF

Growth Performance, Humoral Immune Response and Carcass Characteristics of Broiler Chickens Fed Alkali Processed Karanj Cake Incorporated Diet Supplemented with Methionine

  • Panda, K.;Sastry, V.R.B.;Mandal, A.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.5
    • /
    • pp.677-681
    • /
    • 2005
  • A study was conducted to see the effect of dietary incorporation of alkali (1.5% NaOH, w/w) processed solvent extracted karanj cake (SKC) supplemented with methionine on growth performance, humoral immune response and carcass characteristics of broiler chickens from 0 to 8 weeks of age. One hundred and twenty, day- old broiler chicks were wing banded, vaccinated against Marek' disease and distributed in a completely randomized design (CRD) into 3 groups of 40 chicks each, which was further replicated to 4 and fed on diet containing soybean meal and those of test groups were fed diets containing alkali (1.5% NaOH) treated SKC partially replacing soybean meal nitrogen of reference diet (12.5%) without or with supplementation of methionine (0.2%). Individual body weight of chicks and replicate-wise feed intakes were recorded at weekly intervals throughout the experimental period. Feed consumption from 1 to 14, 28, 42 and 56 d of age was recorded for each replicate and feed conversion efficiency (weight gain/feed intake) for the respective period was calculated. Mortality was monitored on daily basis. On 28$^{th}$ day of experimental feeding, two birds of each replicate in each dietary group (8 birds/diet) were inoculated with 0.1 ml of a 1.0% suspension of sheep red blood cells (SRBC) and the antibody titre (log 2) was measured after 5 days by the microtitre haemmagglutination procedure. After 42 days of experimental feeding, a retention study of 4 days (43-47 d) duration was conducted on all birds to determine the retention of various nutrients such as DM, N, Ca, P and GE. On 43$^{rd}$ day of experimental feeding, one representative bird from each replicate of a dietary treatment (4/dietary group) was sacrificed, after fasting for two hours with free access to water, through cervical dislocation to observe the weight of dressed carcass, primal cuts (breast, thigh, drumstick, back, neck and wing), giblet (liver, heart and gizzard), abdominal fat and digestive organs. The body weight gain of chicks fed reference diet and those fed diet incorporated with NaOH treated SKC (12.5% replacement) with or without methionine supplementation was comparable during 0 to 4 weeks of age. However, dietary incorporation of alkali processed SKC replacing 12.5% nitrogen moiety of soybean meal resulted in growth retardation, subsequently as evidenced by significantly (p<0.05) lowered body weight gain during 0 to 6 weeks of age in birds fed diet incorporated with alkali processed SKC at 6.43% without methionine as compared to those supplemented with methionine or reference diet. Dietary incorporation of alkali (1.5% NaOH) processed SKC replacing 12.5% of soybean meal nitrogen in the diet of broiler chickens had no adverse effect on feed conversion ratio during all the weeks of experimental feeding. The humoral immune response (HIR) as measured by the antibody titre in response to SRBC inoculation was comparable among all the dietary groups. No significant difference in the intake and retention of DM, N, Ca, P or GE was noted among the chicks fed reference and alkali processed SKC incorporated diets with or without methionine supplementation. None of the carcass traits varied significantly due to dietary variations, except the percent weight of liver and giblet. The percent liver weight was significantly (p<0.05) higher in the birds fed diet incorporated with alkali processed SKC as compared to that in other two groups. Thus solvent extracted karanj cake could be incorporated after alkali (1.5% NaOH, w/w) processing at an enhanced level of 6.43%, replacing 12.5% of soybean meal nitrogen, in the broiler diets up to 4 weeks of age, beyond which the observed growth depression on this diet could be alleviated by 0.2% methionine supplementation.

Repetition of Apoptosis Induced by Amiloride Derivatives in Human Umbilical Vein Endothelial Cells (제대정맥 내피세포에서 Amiloride 유도체에 의한 Apoptosis 반복)

  • Park, Kyu Chang;Park, Kyu Sang;Moon, Soo Jee
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.56-66
    • /
    • 2003
  • Purpose : Human umbilical vein endothelial cells(HUVECs) play an important role in regulating blood flow by releasing vasoactive substances. It has been reported that endothelial impairment and dysfunction might be a primary cause of placental vascular disease, which is manifested clinically as preeclampsia in mother and intrauterine growth restriction in fetus. Furthermore, the frequency of apoptotic changes is increased in umbilical and placental tissues from growth-restricted pregnancies. However, the various mechanisms of umbilical endothelial cell apoptosis have not been broadly proposed. We investigate the effects of amiloride derivatives on apoptotic death of HUVECs and identify their ionic mechanism. Methods : HUVECs were purchased from Clonetics, and cultured on endothelial cell growth medium. MTT assay and flow cytometry were used for assessing cytotoxic effect and confirming the apoptosis. Changes in intracellular ion concentrations were measured with specific fluorescent dyes and fluorescence imaging analysis system. Results : Amiloride derivatives elicited cytotoxic effects on HUVECs with dose-dependent manners and the rank order of potency is HMA($IC_{50}\;11.2{\mu}M$), MIA>EIPA>>amiloride. HMA-induced cytotoxicity is dependent on extra- and intracellular pH, that is, increase extra- and intracellular pH augmented the cytotoxic effects of HMA. HMA dose-dependently reduced intracellular major ions, such as $K^+$ and $Cl^-$. Interestingly, the depletion of intracellular ions induced by HMA was also significantly enhanced at alkaline extracellular pH. Conclusion : Amiloride derivatives induce apoptosis of HUVECs with dose and pH dependent manners. They reduce intracellular $K^+$ and $Cl^-$ concentration, which is also extracellular pH dependent.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF