• Title/Summary/Keyword: V.A.K.

Search Result 24,954, Processing Time 0.057 seconds

Adsorptive Catalytic Wave of Chromium-Cupferron Complex (크롬-쿠페론 착물의 흡착 촉매파)

  • Kwon, Young-Soon;Seo, Soh-Jin;Lee, Sang-Mi
    • Analytical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.214-220
    • /
    • 2002
  • The interfacial accumulation of the chromium-cupferron complex and the catalytic wave of its redox process is characterized by cyclic voltammetry. One cathodic peak is observed in the forward scan at -1.45 V. Scanning in the reverse direction produces a inverted peak at -1.39 V, which is indicative of a catalytic process. The optimal conditions of inverted peak were found to be 1 mM borate buffer solution(pH 9.48) containing $1{\times}10^{-4}M$ cupferron, holding potential of -1.8 V and scan rate of 20 mV/s. Using main peak, a preconcentration time of 1 min results in a detection limit of $3.2{\times}10^{-10}M$.

A Study on the Novel SCR NANO ESD Protection Device Design and fabrication (새로운 구조의 나노급 ESD 보호소자 설계 및 제작에 관한 연구)

  • Kim, Kui-Dong;Lee, Jo-Woon;Park, Sang-Jo;Lee, Yoon-Sik;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.9 no.2 s.17
    • /
    • pp.161-169
    • /
    • 2005
  • This paper presents the new structural Low voltage LVTSCR and TWSCR ESD protection circuit. The proposed ESD protection circuit has lower triggering voltage than conventional circuits. And the LVTSCR has the triggering voltage of 9V, current of 7mA and can pass below 0.8KV (150mA/um). The triggering voltage of the Triple-well SCR measured to 6V and the current is 40mA. By the substrate and gate bias, the triggering voltage is lowered down to $4{\sim}5.5V$.

  • PDF

Moleculay Cloning of the cDNA Encoding the 16 kDa Subunit of V-ATPase in Rat Brain (흰쥐 뇌에서 발현되는 16 kDa Vacuolar (H$^{+}$)-ATPase의 유전자 클로닝)

  • Shin, Song-Woo;Yoo, Min
    • Biomedical Science Letters
    • /
    • v.6 no.3
    • /
    • pp.165-170
    • /
    • 2000
  • Vacuolar (H$^{+}$)-ATPase (V-ATPase) is an intracellular protein which consists of multiple subunits. It carries out acidification by pumping protons in the cell. This enzyme has also been found in the synaptic vesicles and may play an important role in the neurotransmission. We cloned cDNA fragments encoding the 16 kDa subunit of V-ATPase from the rat brain by RT-PCR and PCR using total RNA or recombinant phage DNA as templates. They contained the full coding sequences (468 bp) and one nucleotide at 3' region turned out to be different (A to C) when compared to the liver counterpart. However, this polymorphic difference did not cause any significant change in the primary structure of the protein because both GCA and GCC code for alanine. Our study would contribute to the understanding of the function of 16 M)a V-ATPase in the brain and of the mechanisms of neurotransmission.

  • PDF

A Study on the E-TDLNN Method for the Behavioral Modeling of Power Amplifiers (전력 증폭기의 Behavioral 모델링을 위한 E-TDLNN 방식에 관한 연구)

  • Cho, Suk-Hui;Lee, Jong-Rak;Cho, Kyung-Rae;Seo, Tae-Hwan;Kim, Byung-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1157-1162
    • /
    • 2007
  • In this paper, E-TDLNN(Expanded-Tapped Delay Line Neural Network) method is suggested to make the model of power amplifier effectively. This method is the one for making the model of power amplifier through the study in neural network to the target value, the measured output spectrum of power amplifier, after adding the external value factor, gate bias, as an invariant input to the TDLNN method which suggested the memory effect of power amplifier effectively. To prove the validity of suggested method, the data at 2 points, 3.45 V and 3.50 V of gate bias range $3.4{\sim}3.6V$ with the 0.01 V step change, are studied and the predicted results at the gate bias 3.40 V, 3.48 V, 3.53 V and 3.60 V shows good coincidence with the measured values.

A Study on the Remain Life with Aging in 22kV CV Cable (특고압 케이블(6.6/22kV) 케이블의 활선열화 수명 판정 방법에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Lee, Jong-Bok;Park, Dae-Hee;Park, Bok-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1759-1761
    • /
    • 2004
  • In this paper, we studied on life-decision of underground cable of live-line state. Data of CV 6.6kV and 22kV cable's life is got data measured insulation resistance by D.C. overlapped current. We confirmed that D.C resistance reduced by time. Aging of cable could be occurred by electrical, thermal, mechanical stress and complex aging confirmed that proceeded by Weibull plot. In the result, life of 6.6kV cable remained 21 years till light caution and 35 years till heavy caution, so aging of 6.6kV XLPE cable was not occurred. Life of 22kV cable remained 10 years till light caution and 22 years till heavy caution. We confirmed that the designed life of 22kV cable is similar to the measured life.

  • PDF

Effect of Image quality and Radiation Dose using Iterative Reconstruction in Adult and Pediatric CT: A Phantom Study (성인과 소아 CT 촬영시 IR 적용에 따른 영상화질 및 선량에 미치는 영향)

  • Ju, A-ran;Jo, Jung-Hyun;Oh, Young-Kyu;Kim, Kyoung-Ki;Lee, Soo-Been;Jeon, Pil-Hyun;Kim, Daehong
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 2018
  • The main issue of CT is radiation dose reduction to patient. The purpose of this study was to estimate the image quality and dose by iterative reconstruction (IR) for adults and pediatrics. Adult and pediatric images of phantom were obtained with 120 and 140 kV, respectively, in accordance with radiation dose in terms of volume CT dose index ($CTDI_{vol}$): 10, 15, 20, 25, 30, 35 mGy. Then, the adult and the pediatric images are reconstructed by filtered-backprojection (FBP) and iterative reconstruction (IR). The images were analyzed by signal-to-noise ratio (SNR). SNR is improved when IR and 140 kV are applied to acquire adult and pediatric images. In the adult abdomen, according to diagnostic reference level, the SNR values of bone were increased about 27.84 % and 27.77 % at 120 kV and 140 kV, and the tissue's SNR values of the IR were increased about 29.84 % and 33.46 % 120 and 140 kV, respectively. Dose is reduced to 40% in adults abdomen images when using IR reconstruction. In pediatric images, the bone's SNR were also increased about 17.70% and 18.17 % at 120 kV and 140 kV. The tissue's SNR were increased about 26.73 % and 26.15 % at 120 kV and 140 kV. Radiation dose is reduced from 30% to 50% for bone and tissue images. In the case of examinations for adult and pediatric CT, IR technique reduces radiation dose to patient, and it could be applied to adult and pediatric imaging.

Characterization of a Novel Carbohydrase from Lipomyces starkeyi KSM 22 for Dental Application

  • KIM, DOMAN;SU-JIN RYU;SOO-JIN HEO;DO-WON KIM;HO-SANG KIM
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.3
    • /
    • pp.260-264
    • /
    • 1999
  • The combined activities of dextranase and amylase(DXAMase) from Lipomyces starkeyi KSM 22 produced from starch fermentation inhibited or prevented dental plaque formation. The activities were stable in commercial mouthwash products; DXAMase activity retained over 93% of original activity after 6 months at 23℃. We examined the effects of enzyme inhibitors and active ingredients in mouthwash on DXAMase activity. The DXAMase was stable with 0.29%(w/v) EDTA, 20% (v/v) ethanol, 0.05% (w/v) fluoride, and 0.05% (w/v) SDS. Among the active ingredients of mouthwash, sodium benzoate (up to 1 %, w/v) had no inhibitory effect on either dextranase or amylase activity. In the case of cetylpyridinium chloride, the addition of 0.05% (w/v) inhibited 6% of dextranase activity and 13% of amylase activity. Propylene glycol (up to 1%, w/v) showed no inhibitory effect on either enzyme activity. DXAMase (5 IU/㎖) in mouthwash could remove pre-formed films of glucan-bound S. mutans cells. The addition of 0.1 IU/㎖ DXAMase in mouthwash prevented the formation of insoluble-glucan. These in vitro properties of L. starkeyi KSM 22 DXAMase are desirable for its application as a dental plaque control agent.

  • PDF

Surface Defects States on a SiO2/Si Observed by REELS

  • Kim, Juhwan;Kim, Beomsik;Park, Soojeong;Park, Chanae;Denny, Yus Rama;Seo, Soonjoo;Chae, Hong Chol;Kang, Hee Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.271-271
    • /
    • 2013
  • The defect states of a Ar-sputtered SiO2 surface on Si (001) were investigated using Auger electron spectroscopy (AES) and reflection electron energy loss spectroscopy (REELS). The REELS spectra at the primary electron energy of 500 eV showedthat three peaks at 2.5, 5.1, and 7.2 eV were found within the band gap after sputtering. These peaks do not appear at the primary electron energies of 1,000 and 1,500 eV, which means that the defect states are located at the extreme surface of a SiO2/Si thin film. According to the calculations, two peaks at 7.2 and 5.1 eV are related to neutral oxygen vacancies. However, the third peak at 2.5 eV has never been previously reported and the theories proposed that this defect state may be due to Si-Si bonding. Our Auger data showed that a peak for Si-Si bonding at 89 eV appears after Ar ion sputtering on the surface of the sample, which is consistent with the theoretical models.

  • PDF

Advanced P-Channel Poly-Si TFTs for SOG

  • Park, Seong-Jin;Kang, Sang-Hoon;Ku, Yu-Mi;Choi, Jong-Hyun;Jang, Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1019-1022
    • /
    • 2004
  • High performance p-ch poly-Si TFTs with excellent stability were developed. By using a frequency doubled DPSS CW laser, the a-Si on glass could be crystallized into one dimensional single crystalline silicon named as a sequential lateral crystallization (SLC) region. We fabricated p-ch TFTs on SLC region and the typical characteristic values of the TFTs were $u_{fe}$ = 180 $cm^2$/Vs, $V_{th}$ = -3 V, S.S. = 0.5 V/dec, and $I_{off}$ = 1 pA/um@ $V_d$ = -10V. It is found that the TFTs are very stable after bias stresses such as negative and positive gate biases, hot carrier bias and high current bias. These results indicate that the poly-Si in SLC region is suitable for system on glass (SOG) application.

  • PDF

A Study on the Transient Characteristics in 765kV Untransposed Transmission Systems (765kV 비연가 송전계통 과도 특성에 관한 고찰)

  • 안용진;강상희
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.397-404
    • /
    • 2004
  • This paper describes a study of transient characteristics in 765kV untransposed transmission lines. As the 765(kV) system can carry bulk power, some severe fault on the system nay cause large system disturbance. The large shunt capacitance and small resistance of 765kv transmission line make various difficulties for its protection. These problems including current difference between sending and receiving terminals on normal power flow, low order harmonic current component in fault current and current transformer saturation due to the long DC time constant of the circuit etc. must be investigated and solved. The analysis of transient characteristics at sending terminal has been carried out for the single phase to ground fault and 3-phase short fault, etc. The load current, charging current in normal condition and line flows, fault current, THD(Total Harmonic Distortion) of harmonics, time constants have been analysed for the 765kV untransposed transmission line systems.