• 제목/요약/키워드: V-t Characteristic

검색결과 176건 처리시간 0.027초

심실중격결손, 심방중격결손, 폐동맥협착과 우심증을 동반한 완전대혈관전위증의 치험 (A successful Mustard operation for complete transposition of the great arteries combined with VSD, ASD, dextrocardia and PS: a report of one case)

  • 조중구
    • Journal of Chest Surgery
    • /
    • 제15권3호
    • /
    • pp.346-354
    • /
    • 1982
  • A Complete transposition of the great arteries combined with V.S.D, A.S.D, dextrocardia, and P.S is a rare congenital anomaly. The patient was a 10 year-old female whose complaints were frequent URI, exertional dyspnea, and cyanosis at rest since birth. Cheat X-ray films showed Dextrocardia ; situs inversus, moderate cardiomegaly, and Characteristic egg-shape heart shadow. E.K.G, Echocardiography, Cardiac Catheterization, and Angio-Cardiography were performed. Open heart Surgery was done under diagnosis of d-TGA, Dextrocardia, V.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D, A.S.D, and P.S. At the time of Operation, Dextroeardia, T.G.A, Secndum type A.S.D. ($2.0{\times}2.0cm$. in diameter), V.S.D. type II ($1.5cm{\times}1.5cm$ in diameter), and pulmonary valvular stenosis were noted. Mustard operation using pericardial Baffle in the atrium for T.G.A. was perforsned. Teflon patch graft for closure of V.S.D. through tricuspid orifice and pulmonary Valvulotomy through pulmonary arteriotomy were performed. The post-op, low cardiac output Syndrome and dysrhythmicawere developed till Postoperative day #7, so that was controlled by inotropic and antiarrhythmic agents. After that, patient's conditions were Uneventful.

  • PDF

A study on a modeling method about current-voltage characteristic of HTS tape considering resistance of stabilizer

  • Lee, W.S.;Lee, J.;Nam, S.;Ko, T.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.9-12
    • /
    • 2013
  • Current-voltage characteristic models of superconducting material are suggested by many researchers. These current-voltage characteristic models are important because they can be used for design or simulation of superconductor devices. But widely used current-voltage models of superconductor wire still have some limitations. For example, a standard E-J power model has no parameters related with stabilizer's resistance in superconductor wire. In this paper, a current-voltage characteristic modeling method for high temperature superconductor (HTS) tape with considering the effect of stabilizer is introduced. And a current-voltage characteristic of a HTS tape is measured under different stabilizer conditions. Those measured current-voltage characteristics of the HTS tape modeled with proposed modeling method and the modeling results are compared.

VARIATIONS OF THE SOLAR FLARE ENERGY SPECTRUM OVER TWO ACTIVITY CYCLES (1972 - 1995)

  • KASINSKY V. V.;SOTNIKOVA R. T.
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.315-316
    • /
    • 1996
  • Based on X-ray (1-8 ${\AA}$) flux data for 1972-1995 the integral spectra of solar flare energy were computed. It has been shown that the spectral index $\beta$ of the integral energy spectrum (IES) vanes systematically with the 11-year cycle phase. The interval of $\beta$-variations (0.47 <$\beta$<1) is characteristic of UV-Cet stars. The maximum energy of the X-ray flares does not exceed $10^{32}$ erg.

  • PDF

A SOLUTION OF THE ORNSTEIN-UHLENBECK EQUATION

  • MOON BYUNG SOO;THOMPSON RUSSEL C.
    • Journal of applied mathematics & informatics
    • /
    • 제20권1_2호
    • /
    • pp.445-454
    • /
    • 2006
  • We describe a solution to the Ornstein-Uhlenbeck equation $\frac{dI}{dt}-\frac{1}{\tau}$I(t)=cV(t) where V(t) is a constant multiple of a Gaussian white noise. Our solution is based on a discrete set of Gaussian white noise obtained by taking sample points from a sum of single frequency harmonics that have random amplitudes, random frequencies, and random phases. Hence, it is different from the solution by the standard random walk using random numbers generated by the Box-Mueller algorithm. We prove that the power of the signal has the additive property, from which we derive that the Lyapunov characteristic exponent for our solution is positive. This compares with the solution by other methods where the noise is kept to be in an error range so that its Lyapunov exponent is negative.

CSM을 이용한 ADSS유도전압 해석 및 위치선정에 관한 연구 (A Study on Position and Induced Voltage of ADSS Using CSM)

  • 명성호;이병윤;이기철;이재복;하태현;주문노
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1654-1656
    • /
    • 1997
  • Tracking currents related to field exposure for ADSS in T/L is of importance. At phase-ta-phase voltage in excess of 100 kV self-supporting aerial cables with solid insulation tend to suffer damage in regions close to the tower. The damage can be put down to surface tracking currents resulting from different degrees of surface contamination and moisture. Main characteristic of this exposure is the induced voltage analysis and position of ADSS. For complicated calculation of induced voltage on ADSS, this paper described an effective numerical calculation method based on CSM. The proposed methods are applied to 275 kV T/L of Malaysia.

  • PDF

V-형 선형 초음파 모터의 구동 특성 (Driving Characteristic of Ultrasonic Linear Motor With V-type)

  • 정성수;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.425-429
    • /
    • 2007
  • A linear ultrasonic motor was designed by a combination of the longitudinal and bending mode. linear ultrasonic motors are based on an elliptical motion on the surface of elastic body, such as bar or plates. The corresponding eigen-mode of one resonance frequency can be excited twice at the same time with a phase shift of 90 degrees in space and time. That is excite symmetric and anti-symmetric modes. Then it determines the thrust and speed of the motor. Linear ultrasonic motors are investigated experimentally in according to be fabricated a general classification to motor structure and material characteristic. There was the first to simulate as use of finite element analysis ANSYS 9.0. The AL-T2W8-ARM14-LEG18-ANGLE80 motor has a maxim efficiency 18 % under the speed 0.14 m/s, thrust 345 gf and preload 280 gf, operating frequency is 57.6 kHz.

UV 배향된 액정셀에서의 전기광학 특성 (Electro-Optical Characteristics of the UV Aligned LCD Cell)

  • 이병순;이호영
    • 전기학회논문지P
    • /
    • 제62권4호
    • /
    • pp.223-226
    • /
    • 2013
  • In this study, we investigated the electro-optical(EO) characteristic of fringe-field switching(FFS) mode cell by the two kinds of ultraviolet(UV) alignment method on the organic thin film(polyimide: PI). The suitable organic layersfor FFS cell and the aligning capabilities of nematic liquid crystal(NLC) using the in-situ photoalignment method were studied Disclination is observed after conventional photoalignment method for 1h, and in-situ photoalignment method for 1h. Monodomain alignment of the NLC can be observed via in-situ photoalignment method for 2h and 3h. It is considered that NLC alignment is due to photo-depolymerization of the polymer with oblique non-polarized UV irradiation on PI surface. An unstable V-T curve of UV-aligned FFS-LCD with conventional photoalignment method can be achieved. However, a stable V-T curve of UV-aligned FFS-LCD with in-situ photoalignment method(1h), and V-T curve of UV-aligned FFS-LCD with in-situphotoalignment method was much stable comparing with that of other UV-aligned FFS-LCD's. As a result, more stable EO performanceof UV-aligned FFS-LCD with in-situphotoalignment method for 3h is obtained than that of the other UV-aligned FFS-LCD's.

SCR, MVSCR, LVTSCR의 Turn-on time 및 전기적 특성에 관한 연구 (Analysis of SCR, MVSCR, LVTSCR With I-V Characteristic and Turn-On-Time)

  • 이주영
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.295-298
    • /
    • 2016
  • 본 논문에서는 기존 ESD 보호소자인 SCR과 MVSCR, LVTSCR의 Turn-on-Time 및 전기적 특성을 시놉시스사의 T-Cad 시뮬레이션을 통하여 분석하였다. 분석결과 세 소자 모두 대략 2V 에서 3V 내외의 홀딩전압 특성을 보였으며, SCR은 약 20V의, MVSCR은 약 12V, LVTSCR은 9V로 순차적으로 개선된 트리거 특성을 보였다. 턴-온타임 시뮬레이션 결과는 SCR이 2.8ns, MVSCR과 LVTSCR은 각각 2.2ns, 2.0ns로 LVTSCR이 가장 짧은 턴-온 특성을 보였다. 반면 IT2 는 SCR이 약 7.7A, MVSCR은 5.5A LVTSCR은 4A의 특성을 보였으므로 I/O 및 파워 클램프 단에 적용 시 동작전압에 따른 최적화된 소자를 선택해야 한다.

경사 외부자장에 대한 600 kJ급 SMES용 HTS도체의 DC V-I 특성 (DC V-I Characteristics of a High Temperature Superconductor for a 600 kJ Superconducting Magnetic Energy Storage Device in an Oblique External Magnetic Field)

  • 이주영;마용호;류경우;최세용;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제21권1호
    • /
    • pp.79-84
    • /
    • 2008
  • We are developing a small-sized high temperature superconducting magnetic energy storage (HTS-SMES) magnet with the nominal storage capacity of 600 kJ, which provides electric power with high quality to sensitive electric loads. Critical current and N-value of a high temperature superconductor with large current, which was selected for the development of the 600 kJ HTS-SMES magnet, were investigated in various oblique external magnetic fields. Based on the critical current and N-value measured for the short sample conductor, we discussed the DC V - I characteristic of a model coil fabricated with the same conductor of 500 m. The results show that the measured critical current and N-value of the conductor for parallel field are constant in external magnetic fields less than about 0.2 T. However, for oblique fields, its critical current and N -value abruptly decrease in all external magnetic fields. Moreover, the measured critical current of the model coil well agrees with the numerically calculated one based on the DC V - I characteristic measured for the short sample conductor. This suggest that losses and critical currents for an HTS-SMES magnet made up of a high temperature superconductor with anisotropic characteristic are predictable from the data of a short sample conductor.

선박기지국 응용을 위한 중계기용 U형 급전 안테나 설계 (The Design of repeater U-shaped Antenna for ship base station Applications)

  • 박창현;김영남;김갑기
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2007년도 추계학술발표회
    • /
    • pp.211-214
    • /
    • 2007
  • 본 논문에서는 800MHz대역의 TRS(Trunked Radio System)대역을 비롯한, GSM(Global System for Mobile telecommunication), CDMA(Code Division Multiple Access) 대역을 통합할 수 있는 광대역 마이크로스트립 안테나를 설계하고자 한다. 그리고 선박 및 해상 안전에 상용 가능한 선박 기지국 중계기용 안테나를 설계하였다. 마이크로 스트립 안테나의 협대역을 개선하기 위해서 직사각형 패치에 U자 형태의 급전구조를 갖고, 그라운드와 급전 사이에 유전체(${\varepsilon}_T$ = 2.1), 패치와 급전 사이에는 유전체 (${\varepsilon}_T$ = 1)인 서로 다른 유전체를 사용하여 이중 공진 효과를 이용하였다. 설계된 안테나의 주파수 대역폭(VSWR 2:1)은 $780MHz{\sim}1.83GHz$로 2.61GHz의 광대역 특성을 보였으며. 또한 E-평면과 H-평면 모두 이득은 9.dBi이상. 3dB 빔폭은 E-평면 과 H-평면 $60^{\circ}$이상의 개선된 특성을 보였다.

  • PDF