• Title/Summary/Keyword: V-shaped repair

Search Result 8, Processing Time 0.022 seconds

New V-shaped Technique in SLAP Repair (Comparison of Cinical Results Between New V-shaped Repair and Conventional Rapair Technique in Arthroscopic Type II SLAP Surgery) (SLAP 병변 수술에 사용 가능한 새로운 V자 봉합 (Type II SLAP 병변의 관절경적 수술에 있어 새로운 V자 형태의 봉합술기와 기존의 방법과의 임상결과 비교))

  • Hyun, Yoon-Suk;Shin, Sung-Il;Kang, Jung-Woo;Ahn, Joo-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Purpose: The purpose of this study was to compare clinical outcomes between the new V-shaped repair method and conventional methods for the arthroscopic repair of Type II SLAP lesions. Materials and Methods: Our study population consisted of 23 people treated with the new V-shaped repair method or conventional methods in the arthroscopic repair of Type II SLAP lesions at our institution between May 2006 and October 2008. Eleven shoulders were treated using the new V-shaped repair method. Twelve shoulders were treated using conventional methods. The average follow up period was 15 months. For evaluation of clinical results, we used UCLA and VAS pain scores. Results: Comparing change scores (preoperative vs. postoperative states) there were no significant differences in UCLA score or VAS score between the two groups. Conclusion: The new V-shaped repair technique elicits similar clinical results with conventional arthroscopic repair techniques and thus can be considered a useful alternative when using an absorbable suture that is anchor linked with only one suture.

Reconstruction of a Traumatic Cleft Earlobe Using a Combination of the Inverted V-Shaped Excision Technique and Vertical Mattress Suture Method

  • Park, June Kyu;Kim, Kyung Sik;Kim, Seung Hong;Choi, Jun;Yang, Jeong Yeol
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.277-281
    • /
    • 2017
  • Traumatic cleft earlobes are a common problem encountered by plastic and reconstructive surgeons. Various techniques have been reported for the repair of traumatic cleft earlobes. Usually, the techniques of split earlobe repair are divided into two categories, namely straight- and broken-line repairs. Straight-line repair is simple and easy, but scar contracture frequently results in notching of the inferior border of the lobule. It can be avoided by the broken-line repair such as Z-plasty, L-plasty, or a V-shaped flap. Between April 2016 and February 2017, six patients who presented with traumatic cleft earlobe underwent surgical correction using a combination of the inverted V-shaped excision technique and vertical mattress suture method. All the patients were female and had a unilateral complete cleft earlobe. No postoperative notching of the inferior border the lobule occurred during 6-16 months of follow-up. Without the use of a broken-line repair, both the patients and the operators attained aesthetically satisfactory results. Therefore, the combination of the inverted V-shaped excision technique and vertical mattress suture method is considered useful in the treatment of traumatic cleft earlobes.

Design and Manufacture of the Packer of Sewages Mainteance (하수관 보수를 위한 Packer 설계 및 제작)

  • 정재후;윤지섭;김영환;이종열;홍동희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.576-579
    • /
    • 1997
  • In order to repair sewage pipes, it is necessary to dig up the damaged sewage pipes, which results in traffic jams. Since digging up the pipes takes too much time and cost, this method is inefficient. So, in stead of digging up the damaged pipes, a robot is sent down to the pipe to do the repair works. For big pipes, human workers go into the pipe and do to repair works, but for small pipes, it is impossible for human worker to go inside the pipe. In this case, mobile robots have used. The procedures for repairing pipes are as follows : First, the condition of the sewage pipes is observed by a robot. Second, appropriate steps for repair are determined according to the types of the damage. While repairing procedures, a newly-developed packer is sent into the sport to be repaired inside the pipe. Then, the packer is filled with air by a V-shaped wrinkel pipe. This makes the packer inflates uniformly and adhere closely to the inside wall of the pipe in large area. This increases the area that can be repaired. Therefore, the newly-developed packer will be very helpful for sewage pipe repair works.

  • PDF

Scientific Conservation Treatment of the Celadon Jar with the Inscription of 'the Fourth Sunhwa Year'(National Treasure No.326) (국보 제326호 청자 '순화4년'명 항아리의 과학적 보존처리)

  • Lee, Sun Myung;Kwon, Oh Young;Park, Jongseo;Han, Woo Rim
    • Journal of Conservation Science
    • /
    • v.35 no.5
    • /
    • pp.453-469
    • /
    • 2019
  • The celadon jar with inscription of 'the Fourth Sunhwa Year' is an important chronology that shows the conditions of production of the early celadon due to the inscription on the bottom including its purpose, application, and the producer. This celadon jar has been restored several times in the past. However, concerns over the structural stability, such as the separation and level differences in the joined cracks, have risen because of the aging of the repair materials, which were subjected to various environmental changes over a long time. By examining the conditions of preservation, the major damage was identified as the '入' shaped crack on the front, the 'V' shaped restored part and the crack on its left side, and the 'J' shaped crack on the back side. In the past, the cracks were found to be joined using a refined lacquer containing camphor, drying oil, rosin, etc. mixed with soil powder. The joint line was repainted with the refined lacquer and covered with gold powder. The missing parts were restored with gypsum and colored with acrylic color. After that, the repair materials were aged and emergency treatment was performed at the National Museum of Korea in 1981. At that time, Cemedine C or Cemedine C mixed with microballoons was used for reinforcing the cracks. Conservation treatment focused on removing the past repair materials and reinforcing the physically fragile parts by joining and restoring them based on the examination of the preservation condition. in addition, the area around the restored part was colored for future exhibition.

Manufacturing of Cu Repair Coating Material Using the Kinetic Spray Process and Changes in the Microstructures and Properties by Heat Treatment (Kinetic spray 공정을 이용한 Cu repair 코팅 소재 제조 및 열처리에 따른 미세조직과 물성 변화)

  • Jeon, Min-Gwang;Kim, Hyung-Jun;Lee, Kee-Ahn
    • Journal of Powder Materials
    • /
    • v.21 no.5
    • /
    • pp.349-354
    • /
    • 2014
  • This study is a basic research for repair material production which manufactured a Cu repair coating layer on the base material of a Cu plate using kinetic spray process. Furthermore, the manufactured material underwent an annealing heat treatment, and the changes of microstructure and macroscopic properties in the Cu repair coating layer and base material were examined. The powder feedstocks were sphere-shaped pure Cu powders with an average size of $27.7{\mu}m$. The produced repair coating material featured $600{\mu}m$ thickness and 0.8% porosity, and it had an identical ${\alpha}$-Cu single phase as the early powder. The produced Cu repair coating material and base material displayed extremely high adhesion characteristics that produced a boundary difficult to identify. Composition analysis confirmed that the impurities in the base material and repair coating material had no significant differences. Microstructure observation after a $500^{\circ}C/1hr$. heat treatment (vacuum condition) identified recovery, recrystallization and grain growth in the repair coating material and featured a more homogeneous microstructure. The hardness difference (${\Delta}H_v$) between the repair coating material and base material significantly reduced from 87 to 34 after undergoing heat treatment.

Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations

  • Jeong, Ki-Won;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.95-104
    • /
    • 2019
  • PURPOSE. To evaluate the effect of surface treatments and repair materials on the shear bond strength and to measure the fracture toughness of CAD/CAM provisional restoration materials. MATERIALS AND METHODS. Four CAD/CAM (3D printing: Nextdent C&B and ZMD-1000B Temporary, CAD/CAM resin block: Yamahachi PMMA disk and Huge PMMA block) and four conventional (monometacrylate: Jet and Alike, dimetacrylate: Luxatemp and Protemp 4) materials were selected to fabricate disk-shaped specimens and divided into six groups according to surface treatment (n=10). CAD/CAM materials were repaired with Jet or Luxatemp, while conventional materials were repaired with their own materials. The shear bond strength was measured by using universal testing machine. Ten rectangular column-shaped specimens for each material were fabricated to measure the fracture toughness by single edge v notched beam technique. Statistical analysis was performed by one-way ANOVA. RESULTS. The highest shear bond strength of CAD/CAM materials was achieved by SiC paper + sandblasting. It was also accomplished when repairing 3D printing materials with Luxatemp, and repairing CAD/CAM resin blocks with Jet. Yamahachi PMMA disk showed the highest fracture toughness. Nextdent C&B showed the lowest fracture toughness value but no statistically significant difference from Alike and Luxatemp (P>.05). CONCLUSION. In order to successfully repair the CAD/CAM provisional restoration, mechanical surface treatment and appropriate repair material according to the CAD/CAM material type should be selected. The CAD/CAM provisional materials have proper mechanical properties for clinical use as compared to conventional materials.

Bonding of conventional provisional resin to 3D printed resin: the role of surface treatments and type of repair resins

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.322-328
    • /
    • 2020
  • PURPOSE. This study evaluated the shear bond strength between 3D printed provisional resin and conventional provisional resin depending on type of conventional provisional resin and different surface treatments of 3D printed resin. MATERIALS AND METHODS. Ninety-six disc-shaped specimens (Ø14 mm × 20 mm thickness) were printed with resin for 3D printing (Nextdent C&B, Vertex-Dental B. V., Soesterberg, Netherlands). After post-processing, the specimens were randomly divided into 8 groups (n=12) according to two types of conventional repair resin (methylmethacrylate and bis-acryl composite) and four different surface treatments: no additional treatment, air abrasion, soaking in methylmethacrylate (MMA) monomer, and soaking in MMA monomer after air abrasion. After surface treatment, each repair resin was bonded in cylindrical shape using a silicone mold. Specimens were stored in 37℃ distilled water for 24 hours. The shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. Failure modes were analyzed by scanning electron microscope. Statistical analysis was done using one-way ANOVA test and Kruskal-Wallis test (α=.05). RESULTS. The group repaired with bis-acryl composite without additional surface treatment showed the highest mean shear bond strength. It was significantly higher than all four groups repaired with methylmethacrylate (P<.05). Additional surface treatments, neither mechanical nor chemical, increased the shear bond strength within methylmethacrylate groups and bis-acryl composite groups (P>.05). Failure mode analysis showed that cohesive failure was most frequent in both methylmethacrylate and bis-acryl composite groups. CONCLUSION. Our results suggest that when repairing 3D printed provisional restoration with conventional provisional resin, repair with bis-acryl composite without additional surface treatment is recommended.

Arterial Switch Operation for Transposition of The Great Arteries with Ventricular Septal Defect and for Double Outlet Right Ventricle with Subpulmonary Venricular Septal Defect (심실중격결손증을 동반한 대혈관 전위증 및 양대동맥 우심실 기시증에 대한 동맥전환술)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.23 no.6
    • /
    • pp.1118-1127
    • /
    • 1990
  • Arterial switch operation for repair of nineteen cases of transposition of the great arteries associated with ventricular septal defect and three cases with double outlet right ventricle with subpulmonary ventricular septal defect[Taussig-Bing type DORV] was performed from November 1987 to September 1990 at the Seoul National University Children`s Hospital. Sixteen of them were under six months of age, and three were under one year of age with body weight ranged from three to fourteen kilograms. Preoperative cardiac catheterization was done in eighteen patients, in which the pressure of the left ventricle was greater than 70% of the right ventricle in all but one. Patent ductus was associated in thirteen cases[68.4%] of TGA+VSD, and atrial septal defect or patent oval foramen was in sixteen cases. Four atrial septostomy, one modified Blalock- Taussig shunt, one pulmonary artery banding, one coarctoplasty using subclavian arterial flap, were perfomed before arterial switch operation. There were five hospital deaths, all in the. patients with transposition of the great arteries with ventricular septal defect[overall mortality rate 22.7%]. Lecompte Maneuver was used in all patients, and in all patient the U-shaped flap of coronary arteries were transposed to V-shaped cleavage created in the neoaorta. Arterial defect in the neopulmonary artery was covered with 0.0625% Glutaraldehyde fixed autogenous pericardium There have been no late deaths, Postoperative cardiac catheterization and angiocardiogram in four patients has revealed no stenosis in the neopulmonary artery or neoaorta with reasonable P[RV/LV], Anatomic correction for transposition and double outlet right ventricle with subpulmonary ventricular septal defect would seem to be a good operative alternative to intraatrial switch procedures, with the advantage of incorporating the left ventricle to systemic circulation.

  • PDF