• Title/Summary/Keyword: V-B 곡선

Search Result 95, Processing Time 0.023 seconds

Interface study of ion irradiated Cu/Ni/Cu(001)/Si thin film by X-ray reflectivity (이온 조사된 Cu/Ni/Cu(001)/Si 자성박막에 있어서 X-ray reflectivity를 이용한 계면 연구)

  • Kim, T.G.;Song, J.H.;Lee, T.H.;Chae, K.H.;Hwang, H.M.;Jeon, G.Y.;Lee, J;Jeong, K.;Whang, C.N.;Lee, J.S.;Lee, K.B.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.5
    • /
    • pp.184-188
    • /
    • 2002
  • The Cu/Ni/Cu(002)/Si(100) films which have perpendicular magnetic anisotropy were deposited by e-beam evaporation methods. From the reflection high energy electron diffraction pattern, the films were confirmed to be grown epitaxially on silicon. After 2X lots ions/$\textrm{cm}^2$ C+ irradiation, magnetic easy-axis was changed from surface normal to in-plane as shown in the hysteresis loop of magneto-optical Kerr effects. It became manifest from analysis of X-ray reflectivity and grazing incident X-ray diffraction that even though interface between top Cu layer and Ni layer became rougher, the contrast of Cu and Ni's electron density became manifest after ion irradiation. In addition, the strain after deposition of the films was relaxed after ion irradiation. Strain relaxation related with change of magnetic properties and mechanism of intermixed layer's formation was explained by thermo-chemical driving force due to elastic and inelastic collision of ions.

초소형 실리콘 신경탐침의 임피던스 특성 향상 연구

  • Lee, Su-Jin;Lee, Lee-Jae;Yun, Hyo-Sang;Park, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.427-428
    • /
    • 2014
  • 서론: 최근 전세계적인 고령화 진행에 따른 뇌졸중, 파킨슨병, 알츠하이머병 등과 같은 각종 뇌관련 질환에 대한 관심이 더욱 높아지고 있으며 다양한 뇌질환 치료를 위하여 뇌 신경 신호의 정확한 검출 대한 연구가 학계에서 활발히 진행되고 있다. 효과적인 뇌 신경 신호 검출을 위해서는 세포조직의 손상을 최소화 할 수 있는 초소형 신경탐침 및 극소 면적내에서 극대화된 검출 전극이 구현되어야 한다. 그러나, 극소 면적내에 구성된 소면적 전극을 통한 신호 검출은 전극 계면에서의 높은 임피던스를 야기시켜 정밀한 신경신호 검출에 어려움을 만든다. 따라서, 뇌 신경 신호 검출시 전극 계면에서의 낮은 임피던스를 검출하기 위한 다결정실리콘, 이리듐 산화막, 탄소나노튜브와 같은 다양한 전극 소재를 이용한 신경탐침 연구가 제안되어 왔다. 본 연구에서는 극소화된 전극면적과 신경세포 계면에서의 저 임피던스 신경신호 검출을 위하여 비이온성 계면활성제와 전해도금을 이용하여 높은 거칠기값을 갖는 나노동공 백금층을 검출 전극으로 활용하였다. 실험 결과: 제작된 신경탐침의 몸체는 실리콘으로 이루어지며, 탐침 끝단에는 신호 측정을 위한 나노동공 백금층을 갖는 전극들이 집적되어 있다. Fig. 1 는 제작된 나노동공 백금을 갖는 신경탐침의 이미지 (a), SEM (b), TEM (c), FESEM (d) 측정결과를 보여준다. 0.9 %의 NaCl 용액에서 제작된 신경탐침의 계면임피던스 및 위상각 변화에 대한 측정결과가 Fig. 2에 나타나 있다. 1.2 kHz 주파수에서 $942.6K{\Omega}$ ($0.029{\Omega}cm^2$, $3.14{\mu}m^2$)로 극대화된 실표면적을 갖는 나노동공 백금층에 의하여 매우 낮은 임피던스 특성을 보인 것으로 판단된다. 또한 제작된 신경탐침은 위상각이 $-82.9^{\circ}$로서 캐패시터와 같은 역할을 하고 있다고 예상할 수 있었으며 $4.6mFcm^{-2}$의 축전용량값을 보였다. Fig. 3는 1 M의 황산용액에서 나노동공백금층이 형성된 신경탐침 전극과 형성 전의 전기화학적 표면변화를 비교분석한 결과로서 나노동공 백금층의 형성 전/후의 전류응답 특성이 상이하게 나타났다. 나노동공 백금층의 실표면적 극대화로 인한 전류응답수치 또한 크게 향상 되었으며, 0~-0.25 V 영역에서의 수소 흡착에 따른 환원곡선은 전형적인 백금 특성을 보여주는 결과로 판단 할 수 있다. Table 1는 기존에 연구되었던 신경탐침들과 본 연구에서 제작된 나노동공 백금을 갖는 신경탐침의 임피던스와 캐패시턴스 특성을 비교한 결과이다. 결론: 본 연구에서는 실리콘 신경탐침 끝단에 집적된 전극상에 전해도금법을 이용하여 높은 거칠기값을 갖는 나노동공 백금층을 형성하고 전극 계면상의 낮은 임피던스를 검출을 하였다. 나노동공 백금층을 갖는 신경탐침은 순환전압전류법을 통해 극대화된 실표면적을 극대화를 확인할 수 있었으며, 극대화된 검출 전극면은 저 임피던스 측정에 용이함을 실험을 통해서 증명할 수 있었다. 따라서, 높은 거칠기값의 나노동공 백금층은 초소형화된 신경탐침상에 집적되는 전극면적소형화와 다수의 전극 구현에 효과적일 것으로 판단되며 보다 정확한 신경신호 검출을 통한 뇌질환의 명확한 이해에 유망할 것으로 판단된다.

  • PDF

Studies on the Estimation of Annual Tree Volume Growth for the Use as Basic Data on the Plan of Timber Supply and Demand in Korea - The Sub-sampling Oriented - (우리나라 목재수급계획(木材需給計劃)의 기초자료(基礎資料)로 활용(活用)키 위한 연간(年間) 임목성장량(林木成長量)의 추정(推定)에 관한 연구(硏究) - 부차추출법(副次抽出法)을 중심(中心)으로 -)

  • Lee, Jong Lak
    • Journal of Korean Society of Forest Science
    • /
    • v.61 no.1
    • /
    • pp.37-44
    • /
    • 1983
  • This study was to estimate total annual volume growth by the measurement of mean tree growth during the last 10 years. Surveyed Forest stand was the second block (20.80 ha.)of Kyung Hee University Forests located at San 58 and 64, Gaegok-Ri, Gapyung-Yeup, Gapyung-Goon, Kyunggi province in Korea. The stand was mainly composed of uneven-aged Pinus densiflora and the estimation of tree volume was conducted by taking the cores at the D.B.H. of the sample tree which was selected by sub-sampling. The results obtained were as follows; 1) The regression between the diameter (D) and diameter growth ($\hat{I}$) was $\hat{I}=0.5499+0.0101D$. 2) The estimated equation of confidence interval for the diameter growth was $S^2{\hat{I}}=0.00817(0.09538-0.00952D+0.00027D^2$) 3) The equation for estimating tree height (H) from diameter was $H=1.32376D^{0.77958}$ 4) The equation for estimating tree volume from diameter and height $V=0.0000622D^{1.6918}H^{1.1397}$ 5) Total annual tree volume growth was $5.4041m^3/ha$, and ranged from 5.6131 to $5.1984m^3/ha$. 6) Annual growth rate of total tree volume and its error were 8.8% and 3.9%, respectively. The annual volume growth per tree for any districts can be estimated by this method, and the annual volume growth will be successfully predicted. Because of poor forest growing stock in Korea, annual amount of allowable cut should not exceed annual tree volume growth for better forest management. Accordingly, annual amount of allowable cut should be either equal to or less than annual tree volume growth for the balanced establishment between timber supply and demand in Korea. Demand shortage will be substituted with imported timber. Such plans enable Korean Government to develop a better policy of forest resources management.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Risk Assessment Aluminum Levels of Circulating Agricultural Products in Korea (국내 다소비 농산물의 알루미늄 농도 모니터링 및 농산물 섭취로 인한 위해도 평가)

  • An, Jae-Min;Hong, Kyong-Suk;Kim, Sung-Youn;Kim, Ji-Hye;Yu, Kyong-Eun;Kim, Hyo-Young;Park, Hyoung-Dal;Lee, Jae-Hwon;Kim, Dong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.336-344
    • /
    • 2015
  • BACKGROUND: This study was carried out to collect occurrence data on aluminum in 12 type agricultural products and assess dietary exposure risk to the Korean population health for aluminum concentration in agricultural products.METHODS AND RESULTS: Aluminum analysis samples were performed using microwave device and Inductively Coupled Plasma Optical Emission Spectrometer. The LOD(Limit of Detection) for aluminum was 0.851 μg/kg, while the LOQ(Limit of Quantitation) was 2.838 μg/kg and recovery was 97.6% for aluminum. The average levels of aluminum in mg/kg were 0.526 for rice, 0.546 for Korean cabbage, 1.316 for corn, 6.207 for soybean, 0.549 for sweet potato, 0.257 for potato, 6.963 for spinach, 1.213 for carrot, 0.524 for garlic, 0.950 for radish, 1.015 for leek, and 3.511 for Welsh onion. The dietary exposures of aluminum through usual intake were polished rice 89.31 μg/day, Korean cabbage 33.14 μg/day, corn 0.66 μg/day, soybean 3.72 μg/day, sweet potato 6.86 μg/day, potato 4.96 μg/day, spinach 45.96 μg/day, carrot 6.79 μg/day, garlic 2.36 μ g/day, radish 7.32 μg/day, leek 2.23 μg/day and Welsh onion 43.89 μg/day, taking 0.57%, 0.21%, 0.00%, 0.02%, 0.04%, 0.03%, 0.04%, 0.04%, 0.02%, 0.05%, 0.01% and 0.28% of PTWI(2 mg/kg b.w./week), respectively.CONCLUSION: The levels of overall dietary exposure to aluminum for Korean population through intake of agricultural product was far below the recommended JECFA level, indicating of least possibility of risk.