• 제목/요약/키워드: V-형 리브

검색결과 11건 처리시간 0.02초

V-형 사각리브에 의한 난류열전달 해석 (Analysis of turbulent heat transfer over V-shaped ribs)

  • 이영모;김광용
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.169-172
    • /
    • 2005
  • Numerical analysis of turbulent flow in three-dimensional channel with V-shaped ribs extruded on both walls has been carried out. Reynolds-averaged Navier-Stokes are calculated for analysis of fluid flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for heat transfer rate show good agreements with experimental data.

  • PDF

배압 회로를 이용한 인터리브 AC/DC 컨버터의 효율 특성에 관한 연구 (A Study on the Efficiency of Intereaved AC/DC Converter using Voltage-Doubler)

  • 서상화;배진용;권순도;엄태민;김용
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.127-135
    • /
    • 2009
  • 본 연구에서는 2개의 인덕터를 이용한 인터리브 AC/DC 승압형 컨버터의 듀티 사이클이 0.5 이상일 때 배압 회로 특징을 나타내었다. 일반적으로 AC/DC 승압형 컨버터는 낮은 입력전압(입력 AC 110[V])이 높은 입력전압(입력 AC 220[V])에 비하여 낮은 효율을 갖는다. 제안된 인터리브 AC/DC 승압형 컨버터는 낮은 입력전압에서 배압 회로로 동작함으로 인하여 낮은 입력전압을 사용하는 기존의 컨버터와 비교하여 높은 역률과 향상된 효율을 갖는다. 본 연구에서는 배압 회로 동작하는 하는 인터리브 AC/DC 승압형 컨버터를 제안하고, 모드별 해석과 특성을 논의하였으며, 300[W]급 시작품을 제작하여 그 타당성을 검증하였다.

엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석 (Numerical Simulation of Flow and Heat Transfer in Cooling Channel with a Staggered V-shaped Rib)

  • 명현국;김광용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2448-2453
    • /
    • 2008
  • The present study numerically investigates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib-height-to-hydraulic diameter ration (h/$D_h$) is 0.17; the rib pitch-to-height ratio (p/h) equals 2.8; the Reynolds number is 50,000. Shear stress transport (SST) turbulence model is used as a turbulence closure. The present results are compared with those for a continuous V-shaped rib. Computational results show that, for average heat transfer rate the staggered V-shaped rib gives about 2.5 times higher values than the continuous V-shaped rib, while, for the streamwise pressure drop the former gives about 5 times higher values than the latter. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered one gives about 2 times higher values than the continuous one. Also, for the staggered V-shaped rib, complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction, and more uniform heat transfer distributions are obtained.

  • PDF

엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석 (NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN A COOLING CHANNEL WITH STAGGERED V-SHAPED RIBS)

  • 명현국;김광용
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.107-113
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a square cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration (h/$D_h$)of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the channel due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth pipe with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 18 times higher streamwise pressure drop than the latter ones. However, for the thermal performances, based on the equal pumping power condition, the case of p/h=2.8 gives the best result among three cases, mainly due to relatively low streamwise pressure drop, although it gives relatively low heat transfer augmentation.

엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석 (NUMERICAL SIMULATION OF FLOW AND HEAT TRANSFER IN COOLING CHANNEL WITH A STAGGERED V-SHAPED RIB)

  • 명현국;김광용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.125-130
    • /
    • 2008
  • The present study numerically simulates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib pitch-to-height ratio (p/h) varies from 2.8 to 10 with the rib-height-to-hydraulic diameter ration ($h/D_h$) of 0.07 and the Reynolds number of 50,000. Shear stress transport (SST) turbulence model is used as a turbulence model. Computational results show that complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction for all tested cases. In the range of p/h=5 to 10 the staggered V-shaped rib gives about 3 times higher heat transfer augmentation than the reference smooth channel with high heat transfer on both front side and the area around the leading edge of the ribs, while the former cases give about 2.5 times higher streamwise pressure drop than the latter ones. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered ones give about 2 times higher values than the latter ones with more uniform heat transfer distribution.

  • PDF

V-형 리브가 부착된 냉각유로의 형상 최적설계 (Shape Optimization of Cooling Channel with V-shaped Ribs)

  • 이영모;김광용
    • 한국유체기계학회 논문집
    • /
    • 제10권2호
    • /
    • pp.7-15
    • /
    • 2007
  • A numerical procedure for optimizing the shape of three-dimensional channel with V-shaped ribs extruded on both walls has been carried out to enhance the turbulent heat transfer. The response surface based optimization is used as an optimization technique with Reynolds-averaged Wavier-stoked analysis. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show good agreements with experimental data. The objective function is defined as a linear combination of heat transfer and friction loss-related terms with a weighting factor. Three dimensionless variables such as, rib pitch-to-rib height ratio, rib height-to-channel height ratio, and the attack angle of the rib are chosen as design variables. Nineteen training points obtained by D-optimal designs for three design variables construct a reliable response surface. In the sensitivity analysis, it is found that the objective function is most sensitive to the ratio of rib height-to-channel height ratio. And, optimal values of design variables have been obtained in a range of the weighting factor.

전해콘덴서 없는 단상/3상 겸용 11kW, 5.5kW/L 전기차 탑재형 충전기 (E-capless 11kW, 5.5kW/L EV On-Board Charger with Single and Three-Phase Grid Compatibility)

  • 김형진;박준영;함자벨카멜;라마단;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2020년도 전력전자학술대회
    • /
    • pp.25-27
    • /
    • 2020
  • 본 논문은 단상/3상 겸용 단일단 800V 전기차 탑재형 충전기를 제안한다. 제안하는 단일단 충전기는 넓은 단상/3상의 계통전압(120V-240V)에도 스위치의 ZVS 턴 온을 보장하며 전해 콘덴서 없이 DC충전이 가능하다. 2상 인터리브드 토템폴 구조로 구성되어 입력필터가 작으며 전해콘덴서가 없어서 5.5kW/L의 높은 전력밀도를 달성하였다. 또한 4차 고조파 주입 알고리즘을 통해 고조파 규정인 EN 61000-3-2 규정을 만족한다. 시작품의 타당성 및 성능 검증을 위해 SiC 소자를 적용하여 스위칭 주파수 150kHz의 11kW급 충전기를 제작하였고 제안하는 컨버터의 타당성 및 성능을 검증하였다.

  • PDF

태양광 AC 모듈형 인터리브드 플라이백 인버터에서의 입력 단 센서를 제거한 최대 전력점 추종 및 전류 평형 제어 기법 (Sensorless Current Balancing and MPPT Control For Photovoltaic AC Module Type Interleaved Flyback Inverter)

  • 강주석;김영호;윤선재;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.501-502
    • /
    • 2012
  • 본 논문에서는 입력 단 센서를 제거한 태양광 AC 모듈 인터리브드 플라이백 인버터의 최대 전력점 추종 및 전류 평형 제어 기법을 제안한다. 기존 제어 방식들의 수행을 위해서는 입력 전압 $V_{pv}$, 입력 전류 $I_{pv}$ 센서와 각 상 스위치 단의 전류 센서들이 필요하나 4개의 센서와 주변 회로는 AC 모듈의 사이즈, 부피 및 가격을 증가시킨다. 이러한 문제점들을 해결하기 위해 제안하는 방식은 각 상의 전류 센서만을 사용하여 최대 전력점 추종 및 전류 평형 제어를 동시에 수행한다. 제안한 시스템의 타당성을 이론적 분석과 시뮬레이션을 통해 검증한다.

  • PDF

리브형 슬래브를 갖는 유공합성보의 거동에 관한 실험적 연구 (Experimental Study on Behaviour of Composite Beams with Ribbed Slabs and Unreinforced Web Openings)

  • 김창호;박종원;김희구;이창섭;박준용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.989-994
    • /
    • 2000
  • Nine tests to failure are performed on full-scale eight composite beams with unreinforced web opening having ribbed slabs with formed deck which are perpendicular to the steel section and one steel beam. The effects of slab width, reinforcing of stud, moving of rib, moment-shear ratio are studied. At the low M/V ratio, Vierendeel action around the high moment end of the opening is occurred and the large deflection across the opening and transverse cracking are occurred with increasing of applied load. As the M/V ratio increases, the relative deflection across the opening decreases. And at failure, full tensile strain are occurred at bottom T section of steel beam, and concrete crushes at the High Moment End of the opening. With narrow slabs, diagonal tension failure at the high moment end of the opening is occurred. And with wide slabs, rib punch-through failure is occurred near the high moment end of the opening. The implications for design are discussed.

다양한 적층각에 대한 상자형 복합재료 날개의 플러터 특성연구 (A Study of Flutter Analysis for the Composite Box Wings with Various Laminates)

  • 정용현;권혁준;김동현;이인;김천곤
    • Composites Research
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2002
  • 본 연구에서는 실제 구조형상의 사각형 상자형 날개와 전투기 날개에 대하여 구조재를 표피(skin)부분은 복합재료로 대체하고, 나머지 스파(spar)와 리브(rib)는 알루미늄으로 하여 플러터 해석을 수행하였다. MS/PATRAN을 이용하여 실제 날개 구조에 근사한 3차인 유한 요소 모델이 구축되었고, MSC/NASTRAN을 이용하여 고유진동 해석이 수행되었다. 유한 요소는 멤브레인(membrane)요소, 1차원 막대(rod)요소, 전단패널(shear panel)요소를 사용하였다. 복합재료의 적층은 실제적인 적층각을 이용하여 다양하게 변화시켜 해석하였다. 아음속 영역에서 비정상 공력 해석을 위하여 주파수 영역에서의 선형 공기력 이론인 DLM코드가 적용되었고, 주파수 영역 공탄성 지배방정식의 해법으로 V-g방법 및 p-k방법이 적응되었다.