• Title/Summary/Keyword: V-계수

Search Result 1,159, Processing Time 0.026 seconds

Analysis of Correlation between Compressive Strength, Void Ratio and Chloride Diffusion Coefficient of Concrete Using Various Kinds of Cement (시멘트의 종류별 콘크리트외 강도 및 공극률과 염화물 확산계수의 상관관계 분석)

  • Yoon Eui-Sik;Lee Taek-Woo;Park Seung-Bum
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.735-742
    • /
    • 2005
  • The purpose of this study was to evaluate the salt water resistance of concrete depending on various types of cement. In this regard, 5 types of concrete were selected and their strength, void ratio and chloride ion diffusion characteristics were tested, and mutual correlation were analyzed. From the test results, the compressive strength and void ratio of concrete which using Type V cement was as good as Type I cement at long-term ages but the chloride diffusion coefficient of Type V cement was larger than Type I cement. And the concrete replacing some portion of the Type I cement with fly ash was superior in the cases of compressive strength, void ratio and the resistance of chloride ion permeation compared to the Type I cement with the lapse of ages. On the other hand, the compressive strength, the void ratio and the chloride diffusion coefficient of the concrete all indicated high levels of the correlation coefficient and the coefficient of determination regardless of the type of cement.

Evaluation Methods of Compression Index and the Coefficient of Consolidation by Back Analysis of Settlement Data (현장계측치로부터 역산한 압축지수와 압밀계수의 평가 방법)

  • Lee, Dal Won;Lim, Seong Hun;Kim, Ji Moon
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • A large scale field test of prefabricated vertical drains is performed to analyze the effect of parameters of the very soft clay at a test site. Compression index and the coefficient of horizontal consolidation obtained by back-analysis from the settlement data were compared with those obtained by means of laboratory tests. The Hyperbolic, Asaoka's and The Curve fitting methods are used to estimate final settlements and coefficients of consolidation. 1. Final settlement predicted with the Hyperbolic method was the largest, and the settlements predicted with the Asaoka's and the Curve fitting methods were nearly the same range, and it was concluded that smear effect has to be considered on design in the case that spacing of drains is small 2. The relationships of the measured consolidation ratio (Urn) and the designed consolidation ratio($U_t$) were showed as $U_m$ = (1.13~1.17)$U_t$, $U_m$ = (1.07~1.20)$U_t$, $U_m$ = (1.13~1.17)$U_t$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. The relations on the Asaoka's and the Curve fitting methods were nearly the same range. 3. The relationships of the field compression index($C_{cfield}$) and virgin compression index($V_{cclab}$) were showed as $C_{cfield}$ = (1.26~1.45)$V_{cclab}$, $C_{cfield}$ = (1.08~1.15) $V_{cclab}$, $C_{cfield}$ = (1.04~1.21)$V_{cclab}$, on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 4. The ratio ($C_h/C_v$) of the coefficient of vertical consolidation and the coefficient of horizontal consolidation that is obtained by back-analysis from the settlement data was $C_h$=(0.7~0.9)$C_v$, $C_h$=(0.9~1.5)$C_v$, $C_h$=(2.4~3.0)$C_v$ on the Hyperbolic, Asaoka's and the Curve fitting methods, respectively. 5. It was concluded that the exact consolidation coefficient must be determined after the final settlement is predicted again when the consolidation is finished, because the field consolidation coefficient is decreased as the time allowed to be alone is increased.

  • PDF

A/D Converter for Digital Voltmeter (계수형 전압계를 위한 A/D 변환기)

  • No, Hong-Jo;Gang, Jeong-Su;Lee, Gwon-Ha
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.5
    • /
    • pp.1-9
    • /
    • 1971
  • An analog to digital converter Ivhich is applicable to mass production of digital multimeter is developed. The solid state digital instrument has accuracy $\pm$0.1% of feading $\pm$1 digit over 1 mV to 1000 volts with high input impedance and automatic function. All possibility to affect the distortion of A/D converter is tudied. As a result, useful linearity with high temperature stability of integrating waveforms is achieved by the very simplified circuit configuration to assure the proposed accuracy under various ambient condition.

  • PDF

A Study on the Electrochemical Properties of Langmuir-Blodgett Nano-film Mixed with Polyimide and Phospholipid (폴리이미드와 인지질 혼합물의 나노 Langmuir-Blodgett막의 전기화학적 특성에 관한 연구)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.421-428
    • /
    • 2012
  • We investigated an electrochemical properties for Langmuir-Blodgett (LB) nano-films of polyimide and phospholipid mixture. LB films of polyamic acid and phospholipid monolayer were deposited by the Langmuir-Blodgett method on the indium tin oxide(ITO) glass. The electrochemical properties measured by cyclic voltammetry with three-electrode system(an Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode) in $KClO_4$ solution. The current of reduction and oxidation range was measured from 1650 mV to -1350 mV, continuously. The scan rates were 50, 100, 150, 200 and 250 mV/s, respectively. As a result, monolayer LB films of polyamic acid and phospholipid mixture was appeared on irreversible process caused by the reduction current from the cyclic voltammogram. Diffusion coefficient (D) effect in the polyamic acid and phospholipid mixture was used in the LAPC with LLPC fewer than the diffusion coefficient values.

Preparation and Characterization of Heating Element for Inkjet Printer (잉크젯 프린터용 발열체의 제작과 특성연구)

  • 장호정;노영규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • The crystallized stable cobalt silicide$(CoSi_2)$ films were prepared on $poly-Si/SiO_2/Si$substrates for the application of inkjet printing head as a heating element with omega shape. The structural images and temperature resistance coefficient were investigated. The value of temperature resistance coefficient of the heating element was found to be about $0.0014/^{\circ}C$. The maximum power of the heating element was 2 W at the applied voltage of 2 V, 10 kHz in frequency and $1{\mu}s$ in pulse width. From the investigation of fatigue property according to the repeated applied voltages, there was no drastic changes in the resistances of heating element under the condition of $10^8$ pulsed cycles at below 15 V biased voltage. In contrast, the resistance of heating element was greatly increased at $10^6$ pulsed cycles when the heating element was operated at 17 V.

  • PDF

Development of Pressure Drop Model for the Compartment in Reactor Containment (격납용기내 구분방사이의 압력 강하 계산모델 개발)

  • Park, Cheol;Song, In-ho;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.183-193
    • /
    • 1986
  • Full scale HDR containment experiment series pointed out that the previous containment analysis models have a number of shortcomings. One of them is on the calculational model of short term (0~2sec) pressure difference. The pressure differences between subcompartments are dependent on the flow rate, fluid density, head loss coefficient, and flow area ratio. It, however, is not known that any of them is largely attributed to the disagreement of pressure difference between the measured and the calculated values. In this study, the head loss coefficients are expressed with another form to improve the analytic model. The pressure and the pressure difference are evaluated by using COMPARE code with new correlation, and the results show better agreements with experimental values for V.42 test, but overestimate the measured values for V, 43 and underestimate for V.44.

  • PDF

Fabrication and Test of a $HgI_2$ Gamma Ray Detector (감마선 검출용 $HgI_2$ 소자 제작 및 특성 평가)

  • Choi, Myung-Jin;Lee, Hong-Kyu;Kang, Young-Il;Lim, Ho-Jin;Choi, Seung-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 1991
  • The $HgI_2$ single crystal which can be used for the ${\gamma}-ray$ detector at room temperature was grown by Temperature Oscillation Method. The low temperature photoluminescence, specific resistivity and trap concentration of $HgI_2$ single crystal were investigated. Three main luminescence bands were observed at 2.30eV, 2.20eV and 2.00eV at 20K, related to the excitons, I-vacancies and impurities, respectively. The specific resistivity and trap concentration of $HgI_2$ single crystal were $10^{11}{\Omega}\;cm\;and\;1.8{\times}10^{14}/cm^3$ at room temperature, respectively. Also the radiation detecting system was deviced by $HgI_2$ ${\gamma}-ray$ detector, one chip microprocessor, LCD module and personal computer. The prepared $HgI_2$ ${\gamma}-ray$ detector showed a good linearity of ${\gamma}-radiation$ dose for standard ${\gamma}-ray$.

  • PDF

Thermal and temporal stabilities of a electro-optic coefficient $\gamma_{33}$ in a PI-SOT nonlinear polymer thin film (고분자 박막인 PI-SOT의 전기광학계수 $\gamma_{33}$의 열적 . 시간적 안정성)

  • Jeong, Youn-Hong;Jo, Jae-Heung;Chang, Soo;Kim, Tae;lee, Kwang-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.188-194
    • /
    • 1999
  • We synthesized the nonlinear optical (NLO) PI-SOT(polyimide system, 4-[N,N-bis(hydroxyethyl)amino-4,-($\beta$-cyano-$\beta$-methylsulfonyl)vinyl]azobenzene) polymer with high electro-optic coefficients as well as good thermal and temporal stabilities of the elector-optic coefficient ${\gamma}_33$ by the simple Mitsunobu reaction. By using the simple reflection method of C. C. Teng, we measured the thermal and temporal stabilities of the electro-optic coefficient ${\gamma}_33$ of corona-poled PI-SOT polymer at the wavelength of 632.8 nm and 852 nm, respectively. At the temperature of $20^{\circ}C$, the electro-optic coefficient ${\gamma}_33$ of corona-poled PI-SOT polymer were 25.12 pm/V at the wavelength of 632.8 nm and 5.40 pm/V at the wavelength of 852 nm. These values were highly stabilized for more than 60 days at 2$0^{\circ}C$ and stabilized within 6% for more than 10 hours at $100^{\circ}C$.

  • PDF

Assessment of Effective Doses in the Radiation Field of Contaminated Ground Surface by Monte Carlo Simulation (몬테칼로 시뮬레이션에 의한 지표면 오염 방사선장에서의 유효선량 평가)

  • Chang, Jai-Kwon;Lee, Jai-Ki;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.205-213
    • /
    • 1999
  • Effective dose conversion coefficients from unit activity radionuclides contaminated on the ground surface were calculated by using MCNP4A rode and male/female anthropomorphic phantoms. The simulation calculations were made for 19 energy points in the range of 40 keV to 10 MeV. The effective doses E resulting from unit source intensity for different energy were compared to the effective dose equivalent $H_E$ of previous studies. Our E values are lower by 30% at low energy than the $H_E$ values given in the Federal Guidance Report of USEPA. The effective dose response functions derived by polynomial fitting of the energy-effective dose relationship are as follows: $f({\varepsilon})[fSv\;m^2]=\;0.0634\;+\;0.727{\varepsilon}-0.0520{\varepsilon}^2+0.00247{\varepsilon}^3,\;where\;{\varepsilon}$ is the gamma energy in MeV. Using the response function and the radionuclide decay data given in ICRP 38, the effective dose conversion coefficients for unit activity contamination on the ground surface were calculated with addition of the skin dose contribution of beta particles determined by use of the DOSEFACTOR code. The conversion coefficients for 90 important radionuclides were evaluated and tabulated. Comparison with the existing data showed that a significant underestimates could be resulted when the old conversion coefficients were used, especially for the nuclides emitting low energy photons or high energy beta particles.

  • PDF

Consolidation Behavior of Vertical Drain in consideration of Smear Effect and Well Resistance (교란효과와 배수저항을 고려한 연직 배수재의 압밀 거동)

  • Kim, Tae Woo;Kang, Yea Mook;Lee, Dal Won
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.2
    • /
    • pp.225-234
    • /
    • 1998
  • This study was compared the degree of consolidation by Hyperbolic, Curve fitting, Asaoka's, Monden's methods using measured value with theoretical curve in consideration of smear effect and well resistance. The results of the study were summarized as follows ; 1. The degree of consolidation by Hyperbolic method was underestimated than the degree of consolidation by Curve fitting, Asaoka's, and Monden's methods. 2. Typical range of horizontal coefficient of consolidation was $C_h=(2{\sim}3)C_v$ in the case considering smear effect and well resistance, and $C_h=(0.5{\sim}2.5)C_v$ in the case disregarding smear effect and well resistance. 3. The degree of consolidation obtained by ground settlement monitoring was nearly same value when the coefficient of permeability of smear zone by back analysis was shown the half that of in-situ and the diameter of smear zone was shown double that of mendrel. 4. Increasing of diameter reduction ratio of drain, the time of consoildation was delayed. The affection of well resistance the case of small coefficient of permeability was much more than that in the case of large coefficient of permeability. It was recommended that design of diameter reduction of drain consider smear effect and well resistance.

  • PDF