• Title/Summary/Keyword: V 모델

Search Result 1,402, Processing Time 0.033 seconds

The Study on the Performance Evaluation of IPTV according to the increase of network traffic on the Internet Environment (인터넷환경에서 트래픽증가에 따른 IPTV 성능평가에 관한 연구)

  • Cho, Tae-Kyung
    • Journal of Digital Convergence
    • /
    • v.13 no.11
    • /
    • pp.179-185
    • /
    • 2015
  • In this paper, we research the IPTV that is the convergence technique of TV and network technique and performed the performance evaluation of picture quality of IPTV in the situation of increasing the network traffic in the Internet environment. To do this, we constructed the mock Internet network similar to the real Internet environment and measured the quality of received video using V-Factor model according to the increase of network traffic, and analyzed the result of the experiment. Making use of the result of this paper for the threshold value of V-Factor, the measured factor of network performance, the measured factor of video performance in the watchable IPTV video quality.

Determination of Quality Correction Factors for a Plane-Parallel Chamber in High Energy Electron Beams using Monte Carlo Calculation (몬테칼로 계산을 이용한 평판형 전리함의 고에너지 전자선에 대한 선질보정인자 결정)

  • Jeong, Dong-Hyeok;Lee, Jeong-Ok
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.89-95
    • /
    • 2008
  • The quality correction factor for used beam and qualities is strongly required for clinical dosimetry by TRS-398 protocol of IAEA. In this study the quality correction factors for a commercial plane-parallel ionization chamber in high energy electron beams were calculated by Monte Carlo code(DOSRZnrc/EGSnrc). In comparison of quality correction factor, the difference between this study and TRS-398 were within 1% in 5-20 MeV. In case of 4MeV the difference was 1.9%. As an independent method of determination of quality correction factor this study can be applied to evaluate values in the protocol or calculate the factor for a new chamber.

  • PDF

Investigation of Forming Stabilities Criteria in Hot Backward Extrusion of Ti-6Al-4V (Ti-6Al-4V합금의 열간 후방압출에 대한 성형 안정성 평가모델의 고찰)

  • Yeom Jong-Taek;Park Nho-Kwang;Lee You-Hwan;Shin Tae-Jin;Hwang Sang-Mu;Hong Sung-Suk;Shim In-Ok;Lee Chong-Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.3 s.18
    • /
    • pp.84-92
    • /
    • 2004
  • The metal forming behavior of Ti-6Al-4V tube during hot backward extrusion was investigated with various forming stabilities or instabilities criteria. that is, Ziegler's instability criterion, dynamic materials model(DMM) stability criteria and Rao's instability criterion. These approaches also were coupled to the internal variables generated from FE simulation. In order to validate the reliabilities of three criteria, hot backward extrusions for Ti-6Al-4V tube making were carried out with different backward extrusion designs. The useful model for predicting the forming defects was suggested through the comparison between experimental observations and simulation results.

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.

Generation of Video Clips Utilizing Shot Boundary Detection (샷 경계 검출을 이용한 영상 클립 생성)

  • Kim, Hyeok-Man;Cho, Seong-Kil
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.7 no.6
    • /
    • pp.582-592
    • /
    • 2001
  • Video indexing plays an important role in the applications such as digital video libraries or web VOD which archive large volume of digital videos. Video indexing is usually based on video segmentation. In this paper, we propose a software tool called V2Web Studio which can generate video clips utilizing shot boundary detection algorithm. With the V2Web Studio, the process of clip generation consists of the following four steps: 1) Automatic detection of shot boundaries by parsing the video, 2) Elimination of errors by manually verifying the results of the detection, 3) Building a modeling structure of logical hierarchy using the verified shots, and 4) Generating multiple video clips corresponding to each logically modeled segment. The aforementioned steps are performed by shot detector, shot verifier, video modeler and clip generator in the V2Web Studio respectively.

  • PDF

Shape Design of A Spacer for 800kV GIS Interrupter (800kV급 GIS의 모델차단부용 스페이서의 형상설계)

  • Shin, Y.J.;Chang, K.C.;Park, K.Y.;Chong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1639-1642
    • /
    • 1994
  • The severe conditions such as rated voltage of 800kV, gas pressure of $5kg/cm^2$ and rated lighting impulse withstand voltage of 2400kV were adopted for the design of spacers in the 800kV GIS to give a sufficient design margin. The design criteria on the maximum electric field strength of the center conductor and the insulator surface were established by considering the insulator surface characteristics, electrode area and surface effects in the unequal electric field strength of the given gap. The design parameters such as inter/outer envelope degree, thickness, inter/outer inserts, triple junction gap were determined by calculating the electric field using FLUX-2D program package and by referring to the published papers. The mechanical stress analysis was conducted on the feasible model spacers that showed good electric field distributions to confirm the sufficient mechanical design margin. The 800kV spacer designed as described above is now in the process of manufacturing.

  • PDF

Comparative Study of Deep Learning Model for Semantic Segmentation of Water System in SAR Images of KOMPSAT-5 (아리랑 5호 위성 영상에서 수계의 의미론적 분할을 위한 딥러닝 모델의 비교 연구)

  • Kim, Min-Ji;Kim, Seung Kyu;Lee, DoHoon;Gahm, Jin Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.206-214
    • /
    • 2022
  • The way to measure the extent of damage from floods and droughts is to identify changes in the extent of water systems. In order to effectively grasp this at a glance, satellite images are used. KOMPSAT-5 uses Synthetic Aperture Radar (SAR) to capture images regardless of weather conditions such as clouds and rain. In this paper, various deep learning models are applied to perform semantic segmentation of the water system in this SAR image and the performance is compared. The models used are U-net, V-Net, U2-Net, UNet 3+, PSPNet, Deeplab-V3, Deeplab-V3+ and PAN. In addition, performance comparison was performed when the data was augmented by applying elastic deformation to the existing SAR image dataset. As a result, without data augmentation, U-Net was the best with IoU of 97.25% and pixel accuracy of 98.53%. In case of data augmentation, Deeplab-V3 showed IoU of 95.15% and V-Net showed the best pixel accuracy of 96.86%.

V3Si 나노입자 메모리소자의 열적안정성 및 전하누설 근원분석

  • Kim, Dong-Uk;Lee, Dong-Uk;Jo, Seong-Guk;Kim, Eun-Gyu;Lee, Se-Won;Jeong, Seung-Min;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.302-302
    • /
    • 2012
  • 최근 비 휘발성 메모리 시장의 확대와 수요가 많아지면서, 비휘발성 메모리 소자의 제작에 대한 연구가 활발히 진행되고 있다. 특히, 실리사이드 나노입자를 적용한 소자는 현 실리콘 기반의 반도체 공정의 적용이 용이하다. 따라서 본 연구에서는 실리사이드 계열의 화합물 중에서 일함수가 4.63 eV인 Vanadium silicide (V3Si) 나노입자 메모리소자를 제작하여 전기적 특성과 열 안정성에 대하여 알아보았다. p-Si기판에 약 6nm 두께의 SiO2 터널층을 건식 산화 방법으로 성장시킨 후 V3Si 나노입자를 제작하기 위해서 V3Si 금속박막을 스퍼터링 방법으로 4 nm~6 nm의 두께로 터널 절연막 위에 증착시켰다. 그리고 컨트롤 절연막으로 SiO2를 초고진공 스퍼터를 이용하여 50 nm 증착하였고, 급속 열처리 방법으로 질소 분위기에서 $800^{\circ}C$의 5초 동안 열처리하여 V3Si 나노 입자를 형성하였다. 마지막으로 200 nm두께의 Al을 증착하고, 리소그래피 공정을 통하여 채널 길이와 너비가 각각 $2{\mu}m$, $5{\mu}m$, $10{\mu}m$를 가지는 트랜지스터를 제작하였다. 제작된 시편의 V3Si 나노입자의 크기와 균일성은 투과 전자 현미경으로 확인하였고, 후 열처리 공정 이후 V3Si의 존재여부의 확인을 위해서 X-ray 광전자 분광법의 표면분석기술을 이용하여 확인하였다. 소자의 전기적인 측정은 Agilent E4980A LCR meter, 1-MHz HP4280A와 HP 8166A pulse generator, HP4156A precision semiconductor parameter analyzer을 이용하여 측정온도를 $125^{\circ}C$까지 변화시키면서 전기적인 특성을 확인하였다. 본 연구에서는 온도에 선형적 의존성을 가지는 전하누설 모델인 T-model 을 이용하여 나노입자 비휘발성 메모리소자의 전하누설 근원을 확인한 후, 메모리 소자의 동작 특성과의 물리적인 연관성을 논의하였다. 이를 바탕으로 나노입자 비휘발성 메모리소자의 열적안정성을 확보하고 소자 특성향상을 위한 최적화 구조를 제안하고자 한다.

  • PDF

Bias and Gate-Length Dependent Data Extraction of Substrate Circuit Parameters for Deep Submicron MOSFETs (Deep Submicron MOSFET 기판회로 파라미터의 바이어스 및 게이트 길이 종속 데이터 추출)

  • Lee Yongtaek;Choi Munsung;Ku Janam;Lee Seonghearn
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.27-34
    • /
    • 2004
  • The study on the RF substrate circuit is necessary to model RF output characteristics of deep submicron MOSFETs below 0.2$\mum$ gate length that have bun commercialized by the recent development of Si submicron process. In this paper, direct extraction methods are developed to apply for a simple substrate resistance model as well as another substrate model with connecting resistance and capacitance in parallel. Using these extraction methods, better agreement with measured Y22-parameter up to 30 GHz is achieved for 0.15$\mum$ CMOS device by using the parallel RC substrate model rather than the simple resistance one, demonstrating the RF accuracy of the parallel model and extraction technique. Using this model, bias and gate length dependent curves of substrate parameters in the RF region are obtained by increasing drain voltage of 0 to 1.2V at deep submicron devices with various gate lengths of 0.11 to 0.5㎛ These new extraction data will greatly contribute to developing a scalable RF nonlinear substrate model.

An Empirical Study for Cost Saving Effect Analysis When Using Seismic Reinforcing Bar (내진 보강용 철근 사용 시 비용 절감 효과 분석을 위한 실증적 연구)

  • Lee, Jong-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.120-127
    • /
    • 2016
  • Due to the enlargement and high-rise of reinforced concrete structure, the application of high functional material is required. However, high-strength bar is recently introduced to the country and the material is insufficient to measure the variation of quantity of rebar quantitatively when using high-strength bar. For these reasons, this study is to provide useful data in cost decision making when applying high-strength bar at a stage of architectural project planning. For residence-commerce complex buildings, we set up six types of conditions such as in case of using only rebar, in case of using only high-strength bar, in case of using rebar mixed with high-strength bar and so on. With the standard of study model 1 that applies only SD400 regardless of rebar diameter, the analyzed result of rebar variation and the cost change of construction in other study model is as follows. When the rebar amount and cost in study model I was 100%, each ratio was 88.3% and 90.5% in study model II, 80.2% and 83.4% in study model III, 91.9% and 93.5% in study model IV, 88.9% and 87.7% in study model V and 82.4% and 85.5% in study model VI. Therefore, in case of rebar amount and construction cost, study model III was evaluated as the best that was applied only SD600.