• Title/Summary/Keyword: Utilization Efficiency

Search Result 1,952, Processing Time 0.03 seconds

Technical Efficiency of the Shrimp Trawl Fishery in Aru and the Arafura Sea, the Eeastern Part of Indonesia

  • MUAWANAH, Umi;KASIM, Kamaluddin;ENDROYONO, Semm;ROSYIDI, Imron
    • Asian Journal of Business Environment
    • /
    • v.11 no.2
    • /
    • pp.5-13
    • /
    • 2021
  • Purpose: This paper aims to study the fishing capacity of the shrimp trawlers in the Aru and Arafura Sea. Research design, data and Methodology: The abundant shrimp resources call for its sustainable use to advance economic activity. Time-series data of effort and catch from shrimp trawlers from 1980-2015 were utilized. The technical efficiencies of the vessels and the target capacity of the shrimp fishery were estimated using Peak to Peak Method. Results: Arafura's shrimp fishery presents high technical efficiency, which is suggested by the high scores of its fishing capacity utilization. The issuance of a ministerial decree on the prohibition of the use of trawls has impacted the plummeting of Arafura's shrimp trawler production right after the regulation implemented in 2015, which is far below the total production of the Arafura's shrimp trawler in 1980. Today, the Aru and Arafura Sea has different sets of fishing gears that are dominated by Squid Jigging and gillnet vessels. Conclusions: Arafura shrimp fishery performs high technical efficiency, which is indicated by the high utilization value of its catching capacity ranging from 71% to 100% annually from 1980 to 2015 This has shown that the resource-utilization has shifted from shrimps to other economically important species during the post trawl ban such as squid and pelagic. Any future intention to utilize shrimp resources, interaction of gears harvesting shrimp with current gears should be well considered in the policy making process.

Reduce on the Cost of Photovoltaic Power Generation for Polycrystalline Silicon Solar Cells by Double Printing of Ag/Cu Front Contact Layer

  • Peng, Zhuoyin;Liu, Zhou;Chen, Jianlin;Liao, Lida;Chen, Jian;Li, Cong;Li, Wei
    • Electronic Materials Letters
    • /
    • v.14 no.6
    • /
    • pp.718-724
    • /
    • 2018
  • With the development of photovoltaic industry, the cost of photovoltaic power generation has become the significant issue. And the metallization process has decided the cost of original materials and photovoltaic efficiency of the solar cells. Nowadays, double printing process has been introduced instead of one-step printing process for front contact of polycrystalline silicon solar cells, which can effectively improve the photovoltaic conversion efficiency of silicon solar cells. Here, the relative cheap Cu paste has replaced the expensive Ag paste to form Ag/Cu composite front contact of silicon solar cells. The photovoltaic performance and the cost of photovoltaic power generation have been investigated. With the optimization on structure and height of Cu finger layer for Ag/Cu composite double-printed front contact, the silicon solar cells have exhibited a photovoltaic conversion efficiency of 18.41%, which has reduced 3.42 cent per Watt for the cost of photovoltaic power generation.

Estimation of Line Utilization Rate and Track Maintenance Time of Conventional Railway (일반철도의 선로이용율과 선로 유지보수시간 추정)

  • Ki, Hyungseo;Park, Dongjoo;Kim, Dongsoo;Kim, Haengbae
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.638-644
    • /
    • 2012
  • In this study, we numerically estimated available and unavailable time of conventional railway by examining 60% which is known as average range of track utilization efficiency. We also estimated track repair time for maintenance which is the main factor of making track utilization change and analyzed appropriate estimated time. The railway's safety should be guaranteed by appropriate railway operating plan and by adequate rail facilities maintenance. At the same time, daily railway train 'Dia's recovery power should be reflected to the management plan. Considering these factors, we examined mechanical equipment and the national rail network in order to rationally estimate track repair time of the maintenance and to secure spare time in case of train delays. It was found that track utilization efficiency was more or less 60%.

How to Innovate Sellers' Performance in the E-marketplace: Focused on Absorptive Capacity and Information System Use Pattern

  • Lee, Jooryang
    • STI Policy Review
    • /
    • v.2 no.1
    • /
    • pp.55-73
    • /
    • 2011
  • Intermediaries are presenting not only transactional information that orchestrates electronic transaction, but also market related information and knowledge useful for sellers' understanding of the market status. However, we do not have strong evidence that the market related information and knowledge is properly utilized by sellers and that it has an actual influence on sellers' performance. According to the research result, absorptive capacity and the pattern of information system utilization is statistically significant to sellers' performance mediated by operational efficiency and market knowledge creation. Especially, explorative utilization of information system and realized absorptive capacity has a stronger influence on sellers' performance mediated by market knowledge creation. With this research result, this study maintains that sellers are required to absorb and utilize market related information and knowledge more actively through explorative utilization of information system to achieve better performance in the e-marketplace. On the other hand, intermediaries are recommended to provide abundant and valuable market related information and knowledge for the sellers to build up better e-marketplaces.

Effects of Dietary Protein and Threonine Supply on In vitro Liver Threonine Dehydrogenase Activity and Threonine Efficiency in Rat and Chicken

  • Lee, C.W.;Oh, Y.J.;Son, Y.S.;An, W.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.10
    • /
    • pp.1417-1424
    • /
    • 2011
  • This study was conducted to assess the relation between threonine (Thr) oxidation rate and threonine efficiency on rat and chicken fed with graded levels of protein and threonine. The increase in threonine content from 0.28 to 0.72% in a diet containing 12.0% crude protein (CP) caused a gradual increase in threonine dehydrogenase (TDG) activity in rat liver. Similar, but more pronounced results were observed after 18.0% CP in the diet. Both protein levels in combination with the highest level of threonine supplementation increased liver TDG activity significantly, indicating enhanced threonine catabolism. Parameters of efficiency of threonine utilization calculated from parallel nitrogen balance studies decreased significantly and indicated threonine oversupply after a maximum of threonine supplementation. At the lower levels of threonine addition the efficiency of threonine utilization was not significantly changed. In the chicken liver up to 0.60% true digestible threonine (dThr) in the 18.5% CP diet produced no effect on the TDG activity. However, TDG activity in the liver was elevated by the diet containing 22.5% CP (0.60% dThr) and the efficiency of threonine utilization decreased, indicating the end of threonine limiting range. In conclusion, the in vitro TDG activity in the liver of rat and growing chicken has an indicator function for the dietary supply of threonine.

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.

The Effect of Feeding Mannan-Oligosaccharides (Bio-MOS) on the Performance of Meat Chickens under Two Different Vaccination Programs

  • Shafey, T.M.;Al-Mufarej, S.;Shalaby, M.I.;Jarelnabi, A.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.4
    • /
    • pp.559-563
    • /
    • 2001
  • The effects of feeding a mannan oligosaccharide (Bio-Mos) from 0 to 3 g/kg diet and vaccination program on 1- to 35-day performance (growth and feed efficiency), metabolizable energy, nitrogen utilization and carcass composition of meat chickens were investigated. A general vaccination program was used against IB, IBD and ND with half of the birds per diet receiving a booster dose of IB and ND vaccines at 12 days of age. Dietary supplementation of Bio-Mos (BM) did not influence body weight gain, feed efficiency and nutrient utilization. The highest dietary BM (3 versus 1.5 or 0 g/kg) increased carcass abdominal fat and reduced the proportion of drumstick in the carcass of meat chickens. The booster dose reduced the performance of birds. It was concluded that the addition of BM to the diet of chickens did not significantly influence the performance and nutrient utilization of meat chickens.

The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies (공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가)

  • Lee, Yun-Sang;Seo, Jung-Youl;Shin, Hee-Sang;Cho, Sung-Min;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.

An Efficiency Analysis of the Local Cultural Resources Utilization of Local Governments (지방자치단체의 지역문화자원 활용 효율성 분석)

  • Gang, Bobae
    • 지역과문화
    • /
    • v.6 no.2
    • /
    • pp.77-104
    • /
    • 2019
  • This study examines the efficiency of using local cultural resources in local governments. The study does so by DEA(Data Envelope Analysis) using data from the year 2017 for 17 local governments in Korea. In addition, this study tries to estimate environmental efficiency of local cultural resources. For this, the 'Total Efficiency' including the output variables related to the local cultural resource environment was analyzed. After than It compared the 'Total Efficiency' with the 'Utilization Efficiency', to estimate the 'Environmental Efficiency' of local cultural resources. The followings are results which are significant statistically. Firstly, it was evaluated that five of the 17 local governments utilized the local cultural resources efficiently. Secondly, it was result that the inefficiency of the other local governments was relatively influenced by the economies of scale than PTE(Pure Technical Efficiency). Thirdly, It has been confirmed that environmental aspects such as cultural properties and cultural infrastructure have a considerable impact on the increase or decrease of efficiency in local governments. The difference in the efficiency of local governments are influenced by the population density. In order to improve the efficiency in the future, it is necessary to adjust the appropriate level of input according to the local population estimate, which is a major consumer of the local cultural resource utilization. In addition, the local festivals and village festivals held by local governments should be checked to improve in quality by eliminating inefficiencies. Also, it should be considered of environmental factors together, when analyzing the efficiency of the local cultural resource in local governments.

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.