• Title/Summary/Keyword: Utility-reduction

Search Result 196, Processing Time 0.031 seconds

Technique of magnetic survey for UXO discrimination (UXO(Unexploded Ordnance) 탐지를 위한 자력탐사 기술)

  • Park, In-Seok;Kim, Hyun-Do;Kim, Jin-Hoo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.158-159
    • /
    • 2005
  • The paper presents a method for location of subsurface UXOs. The approach utilities gradient interpretation techniques (analytic signal, horizontal gradient and Euler methods) to locate the objects. Then, linear least-squares technique, we obtain the magnetization location of the sources. We demonstrate the practical utility of the method using marine magnetic field data.

  • PDF

Torque Ripple Reduction of Wound-Type Induction Motors Under Unbalanced Utility Voltage (전원 전압 불평형시 권선형 유도전동기의 토크리플 저감)

  • Park, Hong-Geuk;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.885-887
    • /
    • 2008
  • 본 논문에서는 전원전압 불평형시 권선형 유도전동기(wound-type induction motor)에 발생하는 토크리플을 저감하는 방법을 제안한다. 전원 전압에 불평형이 발생할 경우, 전류와 전압은 정상분과 역상분으로 표현되고 역상성분에 의해 고정자에 무효 전력리플이 발생하며 이 성분에 의해 유도전동기는 토크 맥동을 발생한다. 무효전력 리플 성분을 0으로 제어함으로써 토크 리플을 저감할 수 있다. 제안된 토크리플 저감 방법은 PSCAD/EMTDC 시뮬레이션으로 알고리즘의 타당성이 검증된다.

  • PDF

The Consumer Rationality Assumption in Incentive Based Demand Response Program via Reduction Bidding

  • Babar, Muhammad;Imthias Ahamed, T.P.;Alammar, Essam A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.64-74
    • /
    • 2015
  • Because of the burgeoning demand of the energy, the countries are finding sustainable solutions for these emerging challenges. Demand Side Management is playing a significant role in managing the demand with an aim to support the electrical grid during the peak hours. However, advancement in controls and communication technologies, the aggregators are appearing as a third party entity in implementing demand response program. In this paper, a detailed mathematical framework is discussed in which the aggregator acts as an energy service provider between the utility and the consumers, and facilitate the consumers to actively participate in demand side management by introducing the new concept of demand reduction bidding (DRB) under constrained direct load control. Paper also presented an algorithm for the proposed framework and demonstrated the efficacy of the algorithm by considering few case studies and concluded with simulation results and discussions.

Output Power Control of Wind Generation System by Machine Loss Minimization

  • Abo-Khalil Ahmed;Lee Dong-Choon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.51-54
    • /
    • 2005
  • Generator efficiency optimization is important for economic saving and environmental pollution reduction. In general, the machine loss can be reduced by the decreasing the flux level, resulting in the significant reduction of the core loss. This paper proposesan model-based controller is used to decrement the excitation current component on the basis of measured stator current and machine parameters and the q-axis current component controls the generator torque, by which the speed of the induction generator iscontrolled according to the variation of the wind speed in order to produce the maximum output power. The generator reference speed is adjusted according to the optimum tip-speed ratio. The generated power flows into the utility grid through the back-to-back PWM converter. The grid-side converter controls the dc link voltage and the line-side power factor by the q-axis and the d-axis current control, respectively. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

Reduction Methods of Sheath Circulating Current in Underground Cable (지중 송전선로에서 시스 순환전류 저감 방안)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.175-177
    • /
    • 2002
  • The use of underground transmission cables has increased continuously in densely inhabited urban and suburban for power transmission. Two or more transmission lines are outgoing from one substation in many cases, and one line comprises twin circuits. In order to meet the increasing do and for electric power, underground tables of two or fore circuits are installed in ducts in parallel for several kilometer in the same route. It, however, has not been known generally that the sheath circulating current is generated in a system where a large number of cables are laid on the same route. Therefore, this paper describes an improved analysis method for sheath circulating current on underground transmission cables using EMTP. Author propose several methods to reduce sheath circulating current. The analysing method and reduction methods for two or more underground cables will be really improved for cable system utility.

  • PDF

Study on Phase Balancing by Thyristor-Controlled Shunt Compensators (다이리스터제어 병렬보상기를 이용한 상평형에 관한 연구)

  • 차귀수;정태경;최성종;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.11
    • /
    • pp.133-140
    • /
    • 1982
  • In recent years, a number of thyristor-controlled shunt compensators have been used in industrial and utility systems for phase balancing, power-factor correction and flicker reduction. This paper describes a simple and basic control scheme and circuits for shunt compensator with a fixed capacitor and thyristor-controlled reactor. Feedforward-control scheme is applied, and compensating currents are computed from the symmetrical components of the disturbed system. A 8 bit microprocessor is used for the computation of the compensating currents as well as for the measurements of the symmetric components. A 3-phase 1 KVA compensator is developed and a good reduction of the unbalance factor of the power source is achieved using it.

  • PDF

Design of Input Output Filter of Uninterruptible Power Supply (무정전전원장치(UPS)의 입출력필터설계에 관한 연구)

  • Kim, Je-Hong;Cho, Yang-Heang;Son, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.132-135
    • /
    • 2005
  • A design for the input filter and the output filter of a single-phase uninterruptible power supply (UPS) system is proposed. A filter design example is presented. And also, this dissertation describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

A Study On Magnetic Fields Reduction Technologies For Power Transmission Line (송전선 자계저감 기법에 관한 연구)

  • Min, Suk-Won;Kim, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.162-164
    • /
    • 2006
  • There are concern on possible health effects from exposure to electric and magnetic fields. One reflection of this concern is the considerable controversy, delay, and cost increases involved in the construction of utility lines and facilities. To meet such challenges, in this paper we investigated magnetic fields reduction techniqies such as general compaction, in-span compaction, cruciform, vertical, 3way splits phase, and 4way splits phase. As results, we found 1 spacer in-span compaction was appropriate in Korea in view of effectiveness and economy.

  • PDF

The analysis on the characteristic of the conductivity concrete materials (접지저항 저감제 성능분석)

  • Kang, Y.W.;Choi, J.K.;Kwak, J.S.;Joo, H.J.;Shim, E.B.;Bang, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.169-172
    • /
    • 2004
  • The tower footing resistance is an extremely important parameter in the determination of lightning flashover. For the reduction of back flashover faults, power utility companies have had a concern to decrease the footing resistance. There are two manufactures of the conductivity concrete materials in Korea. In this paper, we investigated possibility of soil pollution due to the conductivity concrete materials. Also, we analyzed on the reduction characteristics of footing resistance of those.

  • PDF

An Effectiveness Analysis of the Infrared Signature Reduction with Sea Water Cooling according to the Meteorological Environment (해양환경에 따른 해수냉각의 적외선 신호 저감 효과도 분석)

  • Jung, Ho-Seok;Cho, Yong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.521-528
    • /
    • 2016
  • The surface of a naval ship emits infrared signature because it is mainly heated by the sun. In order to reduce infrared signature, it has been practiced to cool surface of the naval ship by using sea water. In this study, reduction effect of infrared signature was compared according to the parameters which affect emission of infrared signature in order to increase utility of sea water cooling. The analysis results by searching parameters, which can judge operation of sea water cooling, could be utilized as basic data for operation of the naval ship.