분산전원 연계 배전계통의 사고 특성 분석 (Analysis of a Fault Characteristics in the Power Network with Distributed Generators)

  • 장성일;박제영;최정환;정종찬;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.65-68
    • /
    • 2002
  • Distributed Generators (DG) are rapidly increasing and most of them are interconnected with distribution network to supply power into the network. Therefore, DG may make significant impacts on distribution system operation. protection, and control with respect to the voltage regulation, voltage flicker, harmonics, fault current levels, the losses of the network, etc. These impacts would be demerits for both of DG and distribution networks. And the operation of DG may be influenced by the abnormal grid condition such as disturbances occurred in the neighboring distribution feeders as well as the feeder directly connected with DG. This paper describes the influence of fault occurred in the interconnected power network on the DG operation and the impact of DG on the network load during the interruptions of utility power.

  • PDF

시간에 따라 변하는 고속철 부하의 고조파 측정 및 평가 (Time-varying Harmonics Measurement and Evaluation of the High Speed Electric Train Loads)

  • 진성은;김경철;이주홍;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.29-37
    • /
    • 2006
  • 고속철도는 동기 전동기를 제어하기 위한 컨버터 및 인버터를 포함한 많은 비선형 부하를 가지고 있다. 이들 비선형 부하에 의한 고조파는 크기가 클 뿐만 아니라 시간에 따라 변하는 특성을 나타내었다. 부하 용량이 매우 크기 때문에 전력회사에 미치는 영향이 클 뿐만 아니라 이웃 수용가의 전력시스템에 주는 영향 또한 고려되어야 한다. 본 논문에서는 시간에 따라 변하는 고조파를 측정하고 국제 기준인 IEEE 519와 IEC 61000-3-6에 의해 누적확률을 사용하여 평가하였다.

주택용 단상 ESS-PCS의 LC 필터위치에 따른 상용변압기의 특성 (Characteristics of Utility Transformer on Household Single-Phase ESS-PCS According to LC Filter Location)

  • 김용중;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.101-105
    • /
    • 2018
  • Shortage of electric power occurs frequently along with increased electric power demand. ESS is a precaution to solve this issue. Household ESS has a capacity of approximately 3 kW/7 kWh. Household ESS batteries are typically designed with nominal voltages between 40 and 50 V. To connect household ESS with a 220 V AC system, low battery voltages in power conditioning system (PCS) should be boosted. To boost low battery voltage and match it with AC grid voltage, the use of a transformer for a commercial frequency can be considered. To attenuate switching harmonics of the household single-phase ESS-PCS, LC filter can be installed in two positions: on the primary side or on the secondary side of a transformer. A method has been used generally in single-phase inverters for the ESS-PCS. In another method, however, the output efficiency of the ESS-PCS may be decreased. Parasitic components of the transformer can affect voltage losses, when the square wave with the switching frequency in the ESS-PCS is passed through the transformer windings. In this work, the characteristics of the transformer according to the position of an LC filter are investigated for household single-phase ESS-PCS.

Robust Deadbeat Current Control Method for Three-Phase Voltage-Source Active Power Filter

  • Nishida, Katsumi;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.102-111
    • /
    • 2004
  • This paper is concerned with a deadbeat current control implementation of shunt-type three-phase active power filter (APF). Although the one-dimensional deadbeat control method can attain time-optimal response of APF compensating current, one sampling period is actually required fur its settling time. This delay is a serious drawback for this control technique. To cancel such a delay and one more delay caused by DSP execution time, the desired APF compensating current has to be predicted two sampling periods ahead. Therefore an adaptive predictor is adopted for the purpose of both predicting the control error of two sampling periods ahead and bringing the robustness to the deadbeat current control system. By adding the adaptive predictor output as an adjustment term to the reference value of half a source voltage period before, settling time is made short in a transient state. On the other hand, in a steady state, THD (total harmonic distortion) of the utility grid side AC source current can be reduced as much as possible, compared to the case that ideal identification of controlled system could be made.

Multivariable Optimal Control of a Direct AC/AC Converter under Rotating dq Frames

  • Wan, Yun;Liu, Steven;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.419-428
    • /
    • 2013
  • The modular multilevel cascade converter (MMCC) is a new family of multilevel power converters with modular realization and a cascaded pattern for submodules. The MMCC family can be classified by basic configurations and submodule types. One member of this family, the Hexverter, is configured as Double-Delta Full-Bridge (DDFB). It is a novel multilevel AC/AC converter with direct power conversion and comparatively fewer required components. It is appropriate for connecting two three-phase systems with different frequencies and driving an AC motor directly from a utility grid. This paper presents the dq model of a Hexverter with both of its AC systems by state-space representation, which then simplifies the continuous time-varying model into a periodic discrete time-invariant one. Then a generalized multivariable optimal control strategy for regulating the Hexverter's independent currents is developed. The resulting control structure can be adapted to other MMCCs and is flexible enough to include other control criterion while guaranteeing the original controller performance. The modeling method and control design are verified by simulation results.

Appliance Load Profile Assessment for Automated DR Program in Residential Buildings

  • Abdurazakov, Nosirbek;Ardiansyah, Ardiansyah;Choi, Deokjai
    • 스마트미디어저널
    • /
    • 제8권4호
    • /
    • pp.72-79
    • /
    • 2019
  • The automated demand response (DR) program encourages consumers to participate in grid operation by reducing power consumption or deferring electricity usage at peak time automatically. However, successful deployment of the automated DR program sphere needs careful assessment of appliances load profile (ALP). To this end, the recent method estimates frequency, consistency, and peak time consumption parameters of the daily ALP to compute their potential score to be involved in the DR event. Nonetheless, as the daily ALP is subject to varying with respect to the DR time ALP, the existing method could lead to an inappropriate estimation; in such a case, inappropriate appliances would be selected at the automated DR operation that effected a consumer comfort level. To address this challenge, we propose a more proper method, in which all the three parameters are calculated using ALP that overlaps with DR time, not the total daily profile. Furthermore, evaluation of our method using two public residential electricity consumption data sets, i.e., REDD and REFIT, shows that our energy management systems (EMS) could properly match a DR target. A more optimal selection of appliances for the DR event achieves a power consumption decreasing target with minimum comfort level reduction. We believe that our approach could prevent the loss of both utility and consumers. It helps the successful automated DR deployment by maintaining the consumers' willingness to participate in the program.

다양한 일사량 조건에서의 PV-AF 시스템의 특성에 관한 연구 (A Study on the Performance Analysis of the PV-AF System under various Irradiation Conditions)

  • 서효룡;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.212-213
    • /
    • 2007
  • Grid-connected PV(Photovoltaic) power generation system has experienced increasing attention in recent years. But the growing number of non-linear equipments, such as, inverters, has been demanding the compensation for the disturbances caused by them. These non-linear loads may cause poor power factor and high degree of harmonics. Installation of an AF(active filter) can be one of the solutions to mitigate the line distortion, but it requires additional costs. On the other hand, many PV systems have been interconnected to the distribution system. So, the PV system combined with the function of the active filter system can be useful for the application in the power distribution system. In this paper, PV-AF system using DSP (Digital Signal Processing) controller confirmed that it is possible to combine the AF theory to the three phase PV system connected to the utility under various irradiation conditions.

  • PDF

복합발전의 공급전력 안정성 극대화를 위한 파력발전 PCS의 BESS 연동방안 연구 (A Study on the ESS Integration Plan with Inner PCS of Wave-Offshore Hybrid Generation System for Maximizing Power Profile Stability)

  • 정승민;김현욱;유연태;장길수
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.82-91
    • /
    • 2014
  • The combined generator system by integrating several renewable energy sources can share the electrical infrastructure and therefore have the advantage of constructing not only the transmission system but also the power conversion system. Among the various combined renewable system, the wind power and wave power has a high possibility of future growth due to the economic feasibility in offshore environment. This kind of large-scale combined systems might be follow the determination by the transmission system operator's directions and control the output profile by focusing at PCC. However, both renewable energies are depend on the unpredictable environmental variation; it is needed to do the compensation devices. In this paper, the ESS compensation plan is proposed to do output determination of the combined generator system by paying attention to active power of utility grid with the analysis of the controllable elements of the wind and wave power generator. The improvement of the new application technique of the combined system is confirmed through using the PSCAD/EMTDC. The entire simulation process was designed by adopting the active power control according to the reference signal of TSO.

IEEE 929-2000 단독운전 시험조건 하에서 단상 계통연계형 PV 시스템의 Anti-Islanding을 위한 RPV 방식 및 AFD방식의 해석 및 설계 (An Analysis and Design of RPV and AFD Method for Anti-Islanding of Single-Phase UIPV System under The Test Condition Recommended by IEEE 929-2000)

  • 김흥성;김한구;최규하;김재철;최영호
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.37-49
    • /
    • 2007
  • 계통연계형 PV 시스템의 중요한 보호기능인 단독운전 검출기능은 시스템의 안전성 및 전기적 안정성 측면에서 매우 중요하다. 단독운전 검출기법으로는 크게 수동적 방식과 능동적 방식으로 분류되는 다양한 기법들이 있다. 본 연구에서는 IEEE 929-2000에서 제시하는 단독운전 시험조건 하에서 현재 널리 사용되는 능동적 방식 중 무효전력 변동 방식(RPV method)과 능동적 주파수 변동 방식(AFD method)을 채용한 시스템의 연계점에서 주파수 변동 특성을 해석하였다. 그리고 해석결과를 바탕으로 RPV 방식 및 AFD 방식의 설계법을 제시하였다. EMTP를 이용한 시스템 시뮬레이션을 통하여 제안된 해석 및 설계법의 타당성 및 유효성을 검증하였다.

Islanding Detection Method for Inverter-based Distributed Generation Systems using a Signal Cross-correlation Scheme

  • Bae, Byung-Yeol;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.762-768
    • /
    • 2010
  • This paper describes the development of a new islanding detection method for inverter-based distributed generation systems, which uses a signal cross-correlation scheme between the injected reactive current and the power frequency deviation. The proposed method injects 1% of the reactive current to the rated current which brings about a negligible degradation of the power quality. It discriminates the islanding state, when the calculated cross-correlation index is larger than 0.5. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software and experimental research with a hardware prototype. The proposed method can detect the islanding state without degrading the power quality at the point of common connection. Further study is required to overcome the cancellation of the injected reactive current from multiple distributed generation units interconnected with the utility grid.