• 제목/요약/키워드: Utility Grid

검색결과 244건 처리시간 0.027초

정방형 교정 frame을 이용한 카메라의 교정 파라메타 추정에 관한 연구 (A study on the calibration parameter estimation of camera using square calibration frame)

  • 최성구;노도환
    • 전자공학회논문지B
    • /
    • 제33B권7호
    • /
    • pp.127-137
    • /
    • 1996
  • The 3-dimensional measurement using stereo vision system must achieve a camera calibration. So far, the 3-dimensional calibration technique that uses two-dimensional grid papar and a non-linear least square method has been developed and tested. But, this method is inefficient because it has many calculation procedure and a non-linear analysis. Therefore, this paper proposed the projective geometric method which produced the calibration parameter by vanishing point. The vanishing point is producted by a cross ratio and a parallel line pairs. The results of the computer simulation show utility of the proposed method.

  • PDF

BESS 모델링 및 전기철도 급전계통에의 전압보상 적용 (BESS Modeling and Application to Voltage Compensation of Electric Railway System)

  • 유형준;손호익;김학만
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.417-423
    • /
    • 2013
  • The load of electric railroad can generate voltage fluctuation in the electric railway system because of high speed of the electric railroad and frequent movement and stop. This voltage fluctuation of electric railway system can cause not only voltage imbalance but also harmonic in the utility grid. Therefore the electric railroad system is in need of the reactive power compensation, such as static synchronous compensator (STATCOM) and static var compensator (SVC). Especially, the battery energy storage system (BESS) can control the real and reactive power at the same time. In this paper, the electric railway system using BESS has been modeled to show its voltage compensation effect using Matlab/Simulink.

맥동 전압 추출을 통한 배전용 정지형 보상기의 직류링크 전압제어 (DC-Link Voltage Control of Distribution Static Compensator using Ripple Voltage Extraction)

  • 김호열;최종우
    • 전력전자학회논문지
    • /
    • 제17권1호
    • /
    • pp.8-13
    • /
    • 2012
  • DSTATCOM is active filter that reduces nonlinear and unbalanced currents. Researches about DSTATCOM are mainly divided two parts, one is the reference value calculation of compensation current depending on the calculation of the load-side average active power and dc-link capacitor average voltage, the other part is actual current control depending on the reference value of compensation current. This paper proposes a calculation of dc-link capacitor average voltage ripple voltage extraction instead of conventional method using LPF. The utility of the proposed algorithm is verified through the theoretical analysis and the experiment under unbalance loads and non-linear load.

Development of Wave and Viscous Flow Analysis System for Computational Evaluation of Hull Forms

  • Kim, Wu-Joan;Kim, Do-Hyun;Van, Suak-Ho
    • Journal of Ship and Ocean Technology
    • /
    • 제4권3호
    • /
    • pp.33-45
    • /
    • 2000
  • A computational system for wave and viscous flow analysis (WAVIS) has been developed. The system includes a pre-processor, flow solvers and a post-processor. The pre-processor is composed of full form presentation, surface mesh and field grid generation. The flow solvers are for potential and viscous flow calculation. The post-processor has graphic utility for result analysis. All the programs are integrated in a GUI-launcher package. To validate the developed CFD programs of WAVIS, the calculated results for modern commercial hull forms are compared with measurements. It is found that the results from WAVIS are in good agreement with the experimental data, illustrating the accuracy of the numerical methods employed for WAVIS.

  • PDF

3kW 계통연계형 태양광발전시스템의 MPPT제어에 관한 연구 (A Study on the MPPT Control of 3kW Grid-connection Photovoltaic Generation System)

  • 김기범;임홍우;백형래;조금배;김동휘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.340-342
    • /
    • 2001
  • This paper presents a utility interactive photovoltaic generation system with the angle of inclination and direction. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. also, This System is able to alteration the angle of inclination and direction. Hence this paper discusses only points that might be useful for application.

  • PDF

Cost-Effective Converters for Micro Wind Turbine Systems using PMSG

  • Park, Hong-Geuk;Lee, Dong-Choon;Kim, Heung-Geun
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.156-162
    • /
    • 2008
  • This paper proposes a low-cost power converter for micro wind turbine systems using permanent magnet synchronous generators (PMSG). The proposed converter consists of a two-leg three-phase PWM inverter for the generator control and a single-phase half-bridge PWM converter which is connected to the utility grid. For the two separate DC-link voltages, a balancing control is added and the adverse effect of the DC-link voltage ripples on the inverter output voltage is compensated. The control performance of the proposed converter topology for the micro wind turbine system is shown by the simulation results using PSIM software.

단독운전방지를 위한 AFD 와 RPV 방식의 비교 분석 (Analytical comparison of AFD and RPV methods for Anti-Islanding)

  • 바이사;이영진;정병환;김홍성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.64-67
    • /
    • 2008
  • To detect islanding mode when the grid is being tripped is a major safety issue in the Utility Interactive Distributed Generation (UIDG) system. In this paper, analytical design method is suggested for AFD & RPV method under IEEE929-2000 recommended islanding test condition. We have discussed that there is a same point. we injected reactive component of the current by AFD & RPV methods, but the current reference generated is other waveform. Possible if amount of reactive components in this methods are same each method, there is happened same rates frequency variation. To verify the validity of the analytical comparison, this paper presents simulation and experimental results from single phase, 3[kW] inverter for the transformerless UIDG system.

  • PDF

계통전압 불평형시 Fault Ride Through와 전압보상 기능을 갖는 계통연계 인버터의 제어기법 (Control Method for Utility Interactive Inverter with Fault Ride Through and Voltage Compensation under Unbalanced Grid Voltages)

  • 김형진;정아진;김주하;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.207-208
    • /
    • 2012
  • 최근 분산발전시스템에서 계통의 보호를 위해 계통전압 이상이 발생하더라도 일정시간 계통과의 연결을 강제하는 FRT기능이 요구되고 있으며 계통전압 불평형 시에도 계통과의 연결을 유지하도록 요구하고 있다. 이때 독립부하가 존재하는 경우 계통의 이상전압이 독립부하에 그대로 걸리게 되어 독립부하의 전압품질이 저하되는 문제가 있다. 본 논문에서는 계통전압 불평형시 FRT를 수행함과 동시에 독립부하에도 일정한 품질의 전압을 공급할 수 있는 전압보상 기법을 제안한다.

  • PDF

계통연계 분산전원의 새로운 단독운전 판별기법 (Novel Islanding Detection Method for Distributed Generation Interconnected with Utility Grid)

  • 이지헌;전지혜;주영아;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2012-2013
    • /
    • 2007
  • 현재 개발된 분산전원 단독운전 판별기법중 하나인 무효전력주입방식은 판별성능은 우수하나 정격의 $2.5{\sim}5%$의 무효전력을 주입하므로 계통전압에 고조파를 발생하여 전력품질을 저하하는 단점을 갖는다. 본 논문에서는 적은 양의 연속적인 무효전력을 주입하므로 전력품질 저하를 최소화하고 동시에 검출성능이 우수한 인버터연계방식 분산전원의 단독운전 판별기법을 개발하였다. 개발한 판별기법의 타당성을 검증하기위해 EMTDC 소프트웨어를 이용하여 전체시스템의 시뮬레이션모델을 개발하여 시뮬레이션을 실시하였다.

  • PDF

Fuzzy Control for Back to Back Converter in Double-Fed Induction Machine in Wind Power Generation System

  • Sastrowijoyo, Fajar;Windarko, Novie Ayub;Choi, Jaeho;Chung, Gyo-Bum
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.276-277
    • /
    • 2010
  • This paper describes the control of a utility-connected doublefed induction machine (DFIM) for wind power generation systems (WPGS). Real and reactive powers (PQ) at the stator side of DFIM are strictly controlled to supply the power to the grid without any problems. In this paper the control is realized using Fuzzy PI controller based on the stator-flux orientation control.

  • PDF