• 제목/요약/키워드: Useful energy

검색결과 2,409건 처리시간 0.063초

농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;송정석;이효원
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로- (The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;조주영;이효원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

모터팬 방진고무부품의 노화수명 예측 (Prediction of Useful Life by Heat Aging of Motor Fan Isolating Rubber)

  • 김완수;우창수;조상준;김완두
    • Elastomers and Composites
    • /
    • 제37권2호
    • /
    • pp.107-114
    • /
    • 2002
  • 청정실(Clean room)에 사용되는 환기팬용 모터의 방진고무부품의 수명을 예측하기 위해서 가속 열 노화 시험을 수행하였다. 방진고무부품은 EPDM으로 만들었다. 노화 수명을 판단하기 위한 한계점을 20%의 압축 영구 줄음률로 하여 절대 온도의 역수 값으로 아레니우스 선도를 유도하였다. 아레니우스 관계식으로부터 방진고무부품의 다양한 온도에서의 수명과 활성화에너지를 구하였다. 그리고 수명을 판단하는데 있어 상당한 시간을 대체할 수 있는 가속 시험법을 설계하였다. 또한 방진고무부품에 첨가되는 노화 방지제가 수명에 미치는 영향을 알아보았다.

태양 에너지 기반 무선 센서 노드를 위한 에너지 예측 모델의 설계 (Design of Energy Prediction Model for Solar-Powered Wireless Sensor Nodes)

  • 나양타이 불간바트;공인엽
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.858-861
    • /
    • 2012
  • 무선 센서 네트워크를 이용한 응용들 중 특히 환경 모니터링을 위해 대량으로 배치된 센서 노드들은 배터리 교체가 어렵고 교체시에 비용이 많이 드는 단점이 있다. 이를 보완하기 위해서는 무선 센서 네트워크 주위에 존재하는 신재생 에너지를 이용할 필요가 있다. 신재생 에너지들 중 태양 에너지는 매일 사용할 수 있고 에너지의 밀도가 다른 에너지원들 보다 높아 많이 이용되고 있다. 이에 본 논문은 태양 에너지를 충전하여 지속적으로 동작할 수 있는 무선 센서 노드의 에너지 충전 및 방전 특성을 모델링하여 무선 센서 노드의 에너지 활용 형태를 예측할 수 있는 이론적 모델을 제안한다. 개선된 모델에 의해 예측된 결과와 실제 무선 센서 노드의 에너지 활용 패턴을 비교 분석함으로써 실제와 유사하게 모델링할 수 있다.

  • PDF

유압식 엘리베이터용 에너지 저감장치의 개발에 관한 연구 (A Study on the Development of an Energy Saving Unit for a Hydraulic Elevator)

  • 조인성
    • 한국산학기술학회논문지
    • /
    • 제14권5호
    • /
    • pp.2106-2112
    • /
    • 2013
  • 기존의 유압식 엘리베이터에서, 엘리베이터 카는 하강 제어 밸브에 의해 하강하며, 작동유의 유압 에너지는 하강행정 동안 손실 될 수밖에 없다. 본 연구에서는 하강행정 동안 손실되는 유압 에너지를 회수하기 위해서 유압식 엘리베이터용 하이브리드 형 에너지 저감 장치에 대해서 연구하였다. 회수된 에너지는 전기 에너지로 변환하여 저장하고, 저장된 에너지는 엘리베이터의 상승행정 동안에 보조 동력으로 사용하거나 다른 부품의 주동력으로 사용할 수 있다. 본 연구의 결과들은 에너지 저감 장치의 출력 특성이 안정적이고 양호하다는 것을 보여주고 있으며, 본 연구를 통하여 유압식 엘리베이터의 하강행정 동안 손실되는 에너지를 회수하는데 성공하였으며, 회수된 에너지를 재사용하는데 매우 유용하다는 것을 확인하였다.

BIM기반의 공동주택 주동 유형별 건물에너지 시뮬레이션 비교에 관한 연구 (A Comparative Study of Building Energy Simulations for Building Types in Multiple Stock Housing based on BIM(Building Information Modeling))

  • 이병호;이건원;여영호
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.87-100
    • /
    • 2010
  • The energy efficient design of the multiple stock housing is very important not only to save energy but also to increase sustainability in a whole city because the multiple stock housing type is dominated in the major residential supply markets in Korea. During the early design phase of the multiple stock housing type, the architect need convenient and accurate tools for evaluating energy consumptions based on building types rapidly. Building Information Modeling(BIM) is introduced as useful tool systems providing interoperability between 3rd dimensional modeling tools and environmental engineering analysis tools, and could reduce time and cost for unnecessary modeling works in the analysis. However, it is still hard to apply to building design practice and integrated energy simulation techniques because interoperability using industrial standard file formats such as IFC and bXML is still underdeveloped. Therefore, the purpose of this study is to perform the building energy simulations, to compare the results on typical building types in multiple stock housing based on BIM, and to clear the problems using industrial standard file formats between 3rd dimensional modeling and building energy simulation software. In addition, through comparisons with simulation results according to the typical building types such as building forms, orientations, and building stories, the interrelation ship and characteristics of BIM based building energy simulation software are analysed and evaluated.

IFC 데이터의 건물에너지 성능평가를 위한 공간경계정보 호환성 향상 연구 (A Study on the Space Boundary Information Interoperability Improvement of IFC Data for Building Energy Performance Assessment)

  • 최중식;김인한
    • 한국CDE학회논문집
    • /
    • 제19권2호
    • /
    • pp.129-137
    • /
    • 2014
  • Due to the increase of carbon dioxide and building regulations, BIM is considered a way of low-carbon and eco-friendly building development for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some problems in data interoperability in the process of Open-BIM based energy performance assessment. To solve such problems, this study focuses on space boundary information interoperability between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. The study analyzes the analogous study then figures out the problems of IFC based energy performance analysis, and suggests the way of interoperability. Finally, the development of automation program makes this way much more effective. The study of IFC data interoperability is useful for improving the reliability of Open-BIM based energy assessment.

공동주택 단지의 주동형식에 따른 냉난방 에너지 및 외기냉방 효과 분석 (An Analysis of Heating and Cooling Energy and Effect on Outdoor Air Cooling according to Building Type of Apartment Complex)

  • 노지웅
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.31-38
    • /
    • 2014
  • This study makes three apartment building complex an object of analyzing representative building types and energy consumption rate of house holds, and effect of outdoor air cooling. Recently created apatrment complex is composed of very various types of building, plan, and orientation etc. But, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively. Because architects are hard to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject is grasped, apartment building types were examined and representative types were extracted. In this study, energy simulation was conducted, and the effect to outdoor air cooling was analyzed about representative types of the subject apartment complex. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Besides solar gain, household layout of building, orientation, and plan etc. effects compositively on energy consumption rate. 2) The effect of ourdoor air cooling in building of tower type can be improved by arranging households appropriately.

방위각과 초친수코팅에 따른 태양광발전량 시뮬레이션과 하수처리장 에너지자립율 산정 (Estimation of energy self-sufficiency in municipal wastewater treatment plant using photovoltaic power simulated by azimuth and hydrophilic coating)

  • 안영섭;김성태;강지훈;채규정;윤종호
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.133-138
    • /
    • 2011
  • This paper presents energy self-sufficiency simulated in municipal wastewater treatment plants (WWTPs) by adopting solar energy production systems that were simulated by varying azimuth and super-hydrophilic coating on the surface of photovoltaic (PV). Relative to the national average energy consumption in WWTPs, the employment of 100 kW PV system was simulated to achieve 2.75% of energy self-sufficiency. The simulated results suggested that the installation of PVs toward South or Southwest would produce the highest energy self-sufficiency in WWTPs. When super-hydrophilic coating was employed in the conventional PV, 5% of additional solar energy production was achievable as compared to uncoated conventional PV. When 100 kW of PV system was installed in a future test-bed site, Kihyeung Respia WWTP located in Yongin, South Korea, the energy self-sufficiency by solar power was simulated to be 1.77%. The simulated solar power production by azimuth and super-hydrophilic coating will be useful reference for practitioners in designing the solar PV systems in the WWTPs.

Electron Microburst Energy Dispersion Calculated by Test Particle Simulation

  • Lee, Jae-Jin;Kim, Yeon-Han;Park, Young-Deuk
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.94.2-94.2
    • /
    • 2011
  • Electron microbursts, energetic electron precipitation having duration less than 1 sec, have been thought to be generated by chorus wave and electron interactions. While the coincidence of chorus and microburst occurrence supports the wave-particle interaction theory, more crucial evidences have not been observed to explain the origin of microbursts. We propose the measurement of energy dispersion of microbursts could be an evidence supporting wave-particle theory. During chorus waves propagate along magnetic field, the resonance condition should be satisfied at different magnetic latitude for different energy electrons. If we observed electron microbursts at low altitude, the arrival time of different energy electrons should make unique dispersion structures. In order to observe such energy dispersion, we need a detector having fast time resolution and wide energy range. Our study is motivated from defining the time resolution and energy range of the detectors required to measure microburst energy dispersions. We performed test particles simulation to investigate how electrons interact with simple coherent waves like chorus waves. We compute a large number of electron's trajectories and successfully produce energy dispersion structures expected when microbursts are observed with 10 msec time resolution detectors at the altitude of 600 km. These results provide useful information in designing electron detectors for the future mission.

  • PDF