• Title/Summary/Keyword: Used Medical Equipment

Search Result 495, Processing Time 0.023 seconds

Disturbance Observer-Based Hybrid Control of Displacement and Force in a Medical Tele-Analyzer

  • Suebsomran Anan;Parnichkun Manukid
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.70-78
    • /
    • 2005
  • This paper presents hybrid control of displacement and force in a Medical Tele-Analyzer by disturbance observer-based controller which is robust to internal and external disturbances; model uncertainty, load, and friction for instances. The developed Medical Tele-Analyzer consists of 2 subsystems; doctor-side subsystem and patient-side subsystem. In the doctor side subsystem, an array of displacement sensor is equipped to detect movement of doctor's hand and fingers. The detected information is transmitted to the patient side to be used in medical analysis. On the other hand, the patient-side subsystem consists of an array of displacement actuators, which is used to follow displacement of doctor's hand and fingers. An array of force sensors is used to detect forces between patient and the equipment. Since displacement control in patient side is coupled with force control in doctor side and vice-versa, design of the controller has to take into account this coupling. Not only using in medical tele-analysis, the proposed system can also be used in any tele-displacement-force controls of industrial processes.

Development of Teflon Coating Equipment Used in Medical Treatment (의료용 가이드 와이어의 테프론 코팅 장치 개발)

  • Choi, Jeongju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.344-349
    • /
    • 2018
  • This paper proposes a method of designing the main parameters of the Teflon coating equipment of a guide wire used in medical treatment. The proposed device was designed to be guided by a reel-to-reel method in which the guide wire performs all processes continuously, such as Teflon coating and heat treatment. At this time, the conveyed guide wire vibrates between the rollers, which affects the quality of the coating. Therefore, this paper proposes a dynamic equation of the guide wire to be transported in the longitudinal direction, and design parameters setting method of the feed speed and the interval of the roller supporting the wire is proposed to minimize the vibration amplitude of the guide wire during transport. The Teflon coating of the medical guide wire was carried out based on the developed coating equipment. The target coating thickness of the guide wire was set to less than $10{\mu}m$ in the circumferential direction, and the results were examined by optical microscopy.

A Study on the Dataset Construction and Model Application for Detecting Surgical Gauze in C-Arm Imaging Using Artificial Intelligence (인공지능을 활용한 C-Arm에서 수술용 거즈 검출을 위한 데이터셋 구축 및 검출모델 적용에 관한 연구)

  • Kim, Jin Yeop;Hwang, Ho Seong;Lee, Joo Byung;Choi, Yong Jin;Lee, Kang Seok;Kim, Ho Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.290-297
    • /
    • 2022
  • During surgery, Surgical instruments are often left behind due to accidents. Most of these are surgical gauze, so radioactive non-permeable gauze (X-ray gauze) is used for preventing of accidents which gauze is left in the body. This gauze is divided into wire and pad type. If it is confirmed that the gauze remains in the body, gauze must be detected by radiologist's reading by imaging using a mobile X-ray device. But most of operating rooms are not equipped with a mobile X-ray device, but equipped C-Arm equipment, which is of poorer quality than mobile X-ray equipment and furthermore it takes time to read them. In this study, Use C-Arm equipment to acquire gauze image for detection and Build dataset using artificial intelligence and select a detection model to Assist with the relatively low image quality and the reading of radiology specialists. mAP@50 and detection time are used as indicators for performance evaluation. The result is that two-class gauze detection dataset is more accurate and YOLOv5 model mAP@50 is 93.4% and detection time is 11.7 ms.

Development of equipment for tumor cauterization

  • Hoshino, Hirokazu;Ochiai, Makoto;Sakasegawa, Aya;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.474-477
    • /
    • 2002
  • Equipment to cauterize tumors by an electrically heated Kanthal wire is under development. The wire( alloy of iron, chromium and Aluminum) keeps sufficient strength up to 1400 degrees in Celsius. Although AC 50Hz current source is used in the prototype experiment, RF current will be used in future. The diameter of the Kanthal wire was 0.3 mm which was connected to Kanthal wire of 0.8 mm. The thicker wire was used as a leading wire. The possibility of application of the heating wire in combination with an ultrasound endoscope was determined, where ultrasound endoscope is to be used to monitor the location on the wire and an extent of a tumor in digestive organs. This procedure requires the wire to be applied inside ultrasound transmitting media. First, the wire was applied in the degassed water in which a chicken liver sample was submerged. The wire, however, burned out in water soon after it became red-hot at 12 A. The reason is that large current is required for the wire to become red-hot due to strong convection. Starch paste of 3 weight percent was employed instead of water. This made the wire red-hot approximately at 6 A, showing the increased viscosity of the starch decreased the convection and the wire was cover by the steam. The liver sample was cauterized successively, while the location of the wire and the liver was monitored by an ultrasound diagnosis equipment outside the plastic vessel of the starch paste.

  • PDF

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

A new gradient coil design technique for open magnetic resonance imaging systems (개방형 자기공명영상시스템용 경사자계코일의 새로운 설계기법)

  • Lee, Soo-Yeol;Park, Bu-Sik;Yi, Jeong-Han;Yi, Wan
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.1
    • /
    • pp.72-79
    • /
    • 1997
  • Most open magnetic resonance imaging systems have used the planar gradient coils whose inductances were minimized through the magnetic energy minimization procedure in the spatial frequency domain. Though the planar gradient coils have smaller inductance than conventional gradient coils, the planar gradient coils often suffer from their poor magnetic field linearity. Scaling the spatial frequencies of the current density function designed by the magnetic energy minimization, magnetic field linearity of the planar gradient coils can be greatly improved with small sacrifice of gradient coil inductance. We have found that the figure of merit of the planar gradient coils, defined by the gradient strength divided by the linearity error and the inductance, can be improved by proposed technique.

  • PDF

A study on the usefulness of standard evaluation tools for ambulance ride practices of paramedic students (응급구조(학)과 학생들의 구급현장실습 표준 평가도구의 유용성에 관한 연구)

  • Hong, Sung-Gi
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.41-53
    • /
    • 2020
  • Purpose: This study tests the validity of a standard evaluation tool of ambulance ride practices with new evaluation items and supports its application by 119 preceptors. Methods: We tested the validity of standard evaluation items collected from 19 on-site professionals assessing ambulance ride practices. New evaluation items, 'understanding of emergency rescue equipment' and 'ability to communicate', were added as additional criteria. The modified Delphi technique was used to test the three evaluation areas and ten evaluation items. We used the analytic hierarchy process to analyze the weighting value of the reconstructed evaluation tool model. Results: All three evaluation areas and 10 evaluation items within the standard evaluation tools used for ambulance ride practices corresponded with the consistency index, degree of convergence, and agreement in the modified Delphi panel. Conclusion: These results provide evidence of the consistency and usefulness behind preceptors' use of this standard evaluation tool in ambulance ride practice.

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Comparative Analysis of Financial Performance in University Hospital (대학병원의 재무성과 비교 분석)

  • Yang, Jong-Hyun
    • The Korean Journal of Health Service Management
    • /
    • v.14 no.2
    • /
    • pp.15-27
    • /
    • 2020
  • Objectives: The purpose of this study is to compare analysis of financial performance in university hospitals. Methods: Data from 2005 to 2017 were collected from income statement, balance sheet, and annual reports in 23 university hospitals. The dependent variables are used financial performance, namely, medical profit to total assets, medical profit to medical revenue, and net profit to medical revenue. The independent variables are establishment type, hospital province, bed, open liquidity, stability, and activity. Results: From 2005 to 2007, university hospitals steadily increased medical revenues, nonmedical revenues, medical profit, net profit, and reserve fund for essential business by investing fixed assets using financial leverage. From 2015 to 2017, the debt ratio was minimized based on existing management performance. Results showed that university hospitals maintained high profitability by actively investing in medical equipment, medical environment, and facilities using reserve fund for essential business. Conclusions: Results suggest that this will be the basic data for efficient management of university hospitals.

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band (2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석)

  • Shim, Yong-Sup;Lee, Il-Kyoo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.