• Title/Summary/Keyword: Use of force

Search Result 2,235, Processing Time 0.034 seconds

Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation

  • Jeon, Su-Jin;Moon, Young-Mi;Seo, Min-Seock
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.273-281
    • /
    • 2017
  • Objectives: The aims of this study were to quantify tug-back by measuring the pulling force and investigate the correlation of clinical tug-back pulling force with in vitro gutta-percha (GP) cone adaptation score using micro-computed tomography (${\mu}CT$). Materials and Methods: Twenty-eight roots from human single-rooted teeth were divided into 2 groups. In the ProTaper Next (PTN) group, root canals were prepared with PTN, and in the ProFile (PF) group, root canals were prepared using PF (n = 14). The degree of tug-back was scored after selecting taper-matched GP cones. A novel method using a spring balance was designed to quantify the tug-back by measuring the pulling force. The correlation between tug-back scores, pulling force, and percentage of the gutta-percha occupied area (pGPOA) within apical 3 mm was investigated using ${\mu}CT$. The data were analyzed using Pearson's correlation analysis, one-way analysis of variance (ANOVA) and Tukey's test. Results: Specimens with a strong tug-back had a mean pulling force of 1.24 N (range, 0.15-1.70 N). This study showed a positive correlation between tug-back score, pulling force, and pGPOA. However, there was no significant difference in these factors between the PTN and PF groups. Regardless of the groups, pGPOA and pulling force were significantly higher in the specimens with a higher tug-back score (p < 0.05). Conclusions: The degree of subjective tug-back was a definitive determinant for master cone adaptation in the root canal. The use of the tug-back scoring system and pulling force allows the interpretation of subjective tug-back in a more objective and quantitative manner.

The Effect of Change in Gait Speed on Vertical Force of the Cane and Distribution of Affected Foot in the Persons with Chronic Stroke (보행속도의 변화가 만성 뇌졸중 환자 지팡이의 수직력과 마비측 발의 체중지지에 미치는 영향)

  • Jung, Kyoung-Sim;Seo, Hyun-Du;Lee, Kwan-Woo;Chung, Yi-Jung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 2012
  • Purpose : The purpose of this study was to analyze weight bearing of cane and affected foot at different speeds during walking. Methods : Thirteen subjects (6 males, 7 females) with stroke enrolled in the study. A foot sensor and an instrumented cane were integrated to analyze the vertical peak force on the affected foot and the cane. Results : The applied vertical peak force on the cane were $12.02{\pm}4.80%$ (slow speed), $7.97{\pm}3.95%$ (comfortable speed), and $6.86{\pm}3.30%$ (fast speed) body weight, respectively. The results indicated significantly lower vertical peak force on the affected foot in the low speed walking condition when compared to the fast walking (p<.05) and the comfortable walking (p<.05) conditions. The correlations between TUG and vertical peak force on the cane and affected foot were .71, and -.70 (p<.01). There was a higher correlation between the vertical peak force on the cane and affected foot were -.87(p<.01). Conclusion : In conclusion, slower walking speed applied greater vertical peak force on the cane. On the contray, slower walking speed applied less vertical peak force on the affected foot. Further studies, duration of force should be measured at different speeds during walking in lower and higher functioning hemiparetic subjects, as its use may mask underlying gait impairment.

A remote control robot manipulator using force feedback joystick (로봇 매니퓰레이터 원격 제어)

  • Kim, In-Soo;Hyun, Woong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1823-1824
    • /
    • 2008
  • We propose a remote controlled robot manipulator using force feedback joystick. User can control easily 5 d.o.f robot manipulator in 3 demensional space using general joystick. A force sensor attached in developed gripper sends signal to main robot controller so as to know gripper grasp the object. The signal also sent to user through force feedback joystick. We designed a dexterous 5 d.o.f robot manipulator analysis the kinematics and inverse kinematics. The robot was simply developed using serial RC motor. As a main robot controller, we use 32bit MPU(AT91SAM7256) and micro C/OS. To show the validity of our developed robot, a several experiments were demonstrated.

  • PDF

Automated Assessment Of The Air Situation During The Preparation And Conduct Of Combat Operations Using A Decision Support System Based On Fuzzy Networks Of Target Installations

  • Volkov, Andriy;Bazilo, Serhii;Tokar, Oleksandr;Horbachov, Kostiantyn;Lutsyshyn, Andrii;Zaitsev, Ihor;Iasechko, Maksym
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.11
    • /
    • pp.184-188
    • /
    • 2022
  • The article considers the improved method and model of automated air situation assessment using a decision support system based on fuzzy networks of target installations. The advanced method of automated assessment of the air situation using the decision support system is based on the methodology of reflexive control of the first rank. With this approach, the process of assessing the air situation in the framework of the formulated task can be reduced to determining the purpose, probabilistic nature of actions and capabilities of the air target. The use of a homogeneous functional network for the formal presentation of air situation assessment processes will formally describe the process of determining classes of events during air situation assessment and the process of determining quantitative and qualitative characteristics of recognized air situation situations. To formalize the patterns of manifestation of the values of quantitative and symbolic information, it is proposed to use the mathematical apparatus of fuzzy sets.

A Method of Reducing a Tolerance of a Shunt Resistor for Balance of the Battery Cell to Improve a Precision of BMS (BMS 정밀도 향상을 위한 셀 밸런싱용 션트 고정저항의 허용오차 저감 방법)

  • Kim, Eun-Min;Son, Mi-Ra;Kang, Chang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1055-1061
    • /
    • 2018
  • Recently, due to the rapid development of electric vehicle and energy storage system, it is emphasized for battery management system to be needed and to be improved. BMS carries out various movement for optimization the use of the energy and safe use of secondary battery, these movement of BMS start at high wattage shunt fixed resistor which performs a function for detecting current among the BMS components. In addition, for the safe operation of secondary battery, the reliability of current voltage variation detected from shunt should be secured, and for corresponding characteristics, the quality of Temperature coefficient of resistance for BMS shunt and the quality of Thermo electromotive force all must be excellent. For these reasons, this study comes up with the stabilization plan for thermo electromotive force and temperature coefficient of resistance of BMS shunt resistor which is key to secondary battery operation.

Experimental Study on the Optimized Lubrication Conditions in MQL Turning of Workpieces with Taper Angle (테이퍼 각을 가진 소재의 MQL 선삭가공에서 최적 윤활 조건에 관한 실험적 연구)

  • Kim, Dong-Hyeon;Kang, Dong-Wi;Cha, Na-Hyeon;Lee, Choon-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.1
    • /
    • pp.63-69
    • /
    • 2013
  • Many researchers are trying to reduce the use of lubrication fluids in metal cutting to obtain safety, environmental and economical benefits. The aim of this study is to determine the optimization lubrication conditions in minimum quantity lubrication(MQL) turning of workpieces with taper angle. This study has been considered about various conditions of MQL. The objective functions are cutting force and surface roughness. Design factors are nozzle diameter, nozzle angle, MQL supply pressure, distance between tool and nozzle and length of supply line. The cutting force and surface roughness were statistically analyzed by the use of the Box-Behnken method. As a results, optimum lubrication conditions were suggested and verification experiment has been performed. The results of this study are expected to help the selection of lubrication conditions in MQL turning.

Spot Welding of Aluminum Alloys Using Servogun (서보건을 이용한 알루미늄 합금의 저항 점용접)

  • 임창식;장희석
    • Journal of Welding and Joining
    • /
    • v.22 no.4
    • /
    • pp.43-49
    • /
    • 2004
  • Conventional method for electrode force application in resistance spot welding(RSW) processes is to use pneumatic cylinder. However, due to its inherent problems in pneumatic power system such as compressibility of air and poor transient response characteristics, new electrode force system with servo control are recently introduced in RSW machine. This machine is called “servogun”. The purpose of this study is to evaluate performance of servogun in case of spot welding of aluminum alloy. Aluminum alloy(A5052) sheets are spot welded using pneumatic gun and servogun. Both results are compared by means of macro cross-section etching test and tensile shear strength test. Numerous previous research have reported nugget with many voids and cracks are not uncommon defects in spot welds with aluminum alloy. The experimental results show similar defects in case of pneumatic gun. In contrast, use of servogun considerably reduced generation of voids and cracks. In case of step-wise increased forging force at the end of welding cycle with servogun, crack-free and void-free nuggets have been observed. The performance of servogun has been also verified by series of tensile shear test. Higher strength values have been achieved with servogun in comparison to that of pneumatic gun.

Design of a New Haptic Device using a Parallel Mechanism with a Gimbal Mechanism

  • Lee, Sung-Uk;Shin, Ho-Chul;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2331-2336
    • /
    • 2005
  • This paper proposes a new haptic device using a parallel mechanism with gimbal type actuators. This device has three legs actuated by 2-DOF gimbal mechanisms, which make the device simple and light by fixing all the actuators to the base. Three extra sensors are placed at passive joints to obtain a unique solution of the forward kinematics problem. The proposed haptic device is developed for an operator to use it on a desktop in due consideration of the size of an average Korean. The proposed haptic device has a small workspace for on operator to use it on a desktop and more sensitivity than a serial type haptic device. Therefore, the motors of the proposed haptic device are fixed at the base plate so that the proposed haptic device has a better dynamic bandwidth due to a low moving inertia. With this conceptual design, optimization of the design parameters is carried out. The objective function is defined by the fuzzy minimum of the global design indices, global force/moment isotropy index, global force/moment payload index, and workspace. Each global index is calculated by a SVD (singular value decomposition) of the force and moment parts of the jacobian matrix. Division of the jacobian matrix assures a consistency of the units in the matrix. Due to the nonlinearity of this objective function, Genetic algorithms are adopted for a global optimization.

  • PDF

A Study of an Effect of Tool Offset on Cutting Precision Considering Cutting Force in Polyurethane Foam Cutting (폴리우레탄폼 절삭에서 절삭력을 고려한 공구 오프셋이 가공정도에 미치는 영향에 관한 연구)

  • Min, Se-Hong;Kim, Hui-Song
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.3018-3025
    • /
    • 2000
  • It is possible to shorten developing process by making model using polyurethane foam in the area of automobile development process, etc. However, this skill is too difficult to be of practical use because machining is not easy due to characteristic of polyurethane foam. Domestic and foreign automobile company use clay, polyurethane foam. etc,, those are easy to handle and to make model after completing design sketch. But these materials is difficult to the machined and be worked by humans hand, There are so many difficult problem for machining by making model using polyurethane foam since cutting of elastic body like polyurethan foam has never been studied. Therefore, in this study, it is investigated to measured cutting force that is generated in case of polyurethane foam machining, and to make systematize tool compensation of polyurethane foam cutting work on automobile model by modification of tool offset method on existing steel.

Design, Fabrication and Test of Piezoelectric Actuator Using U-Shape PZT Strips and Lever Structure for Lateral Stroke Amplification (수평방향 변위증폭을 위해 U-형상의 PZT 스트립과 지렛대 구조를 이용한 압전구동형 액추에이터의 설계, 제작 및 실험)

  • 이준형;이택민;최두선;황경현;서영호
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1937-1941
    • /
    • 2004
  • We present lateral actuated piezoelectric actuator using U-shaped PZT strip and lever structure for the RF switch application. In the previous study of RF switch, they used horizontal contact switch fabricated by thin film metals. However, thin film metals could not generate large contact force due to low stiffness. In this work, we suggest lateral contact switch which makes large contact force by increasing stiffness. In addition, we use PZT actuator for the high force actuation. Generally actuator using thin film PZT moves to the vertical direction due to the neutral axis shift. Therefore we need lateral motion generation mechanism based on the thin film PZT actuator. In order to increase lateral motion of thin film PZT actuator, we use U-shaped PZT actuator using residual stress control. Also, thin film PZT actuator can generate very small lateral motion of 120${\times}$10$^{-6}$ ${\mu}{\textrm}{m}$/V for d$_{31}$ mode, thus we suggest lever structure to increase stroke amplification. From the experimental study, fabricated PZT actuator shows maximum lateral displacement of 1 ${\mu}{\textrm}{m}$, and break down voltage of the thin film PZT actuator is above 16V.