• 제목/요약/키워드: Urine Sample

검색결과 216건 처리시간 0.032초

퍼지이론을 이용한 뇨분석 시스템 개발에 관한 연구 (A Study on the Development of Urine Analyzer System using Fuzzy Theory)

  • 이승진;최병철;엄상희;이영우;손한철;전계록
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.14-18
    • /
    • 1997
  • In this paper, we suggested and made a classifier or qualitative and quantitative analysis in urine analysis system. Input variable number and fuzzy membership function was made from determination of standard sample, and the fuzzy rules were determined by the analysis of spectroscopic properties of pads in strip. Fuzzy classifier used in urine analysis system was evaluated or the standard samples in each items and degrees. Negative and positive response of urine test was classified in good property, but detail classification or quantitative analysis had 8% maximum error in each items. If fuzzy membership unction and generation of rule are supplemented, suggested fuzzy classifier can be applied to the clinical test.

  • PDF

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

LC-MS/MS를 이용한 소변 중 크레아티닌 분석의 측정불확도 평가 (Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS)

  • 김진영;권운용;서승일;인문교
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.83-90
    • /
    • 2012
  • 소변 중 크레아티닌의 정상적인 농도범위는 30 - 300 mg/dL로 마약류 감정에 앞서 크레아티닌농도를 측정함으로써 소변 시료의 유효성을 확인하고 있다. 크레아티닌 농도 측정을 위해 액체크로마토그래피-질량분량분석법(LC-MS/MS, liquid chromatography-tandem mass spectrometry)을 사용하였다. 우선 소변 시료를 고속으로 원심분리한 후 10 ${\mu}L$를 분취하여 증류수 390 ${\mu}L$와 혼합하여 희석하였다. 희석된 시료 20 ${\mu}L$에 내부표준물질(5 ${\mu}g/mL$) 30 ${\mu}L$와 acetonitrile 10 ${\mu}L$를 첨가하여 혼합한 후 여과한 시료를 LC-MS/MS에 주입하였다. 크레아티닌은 multi-mode ODS column (Scherzo SM-C18, 75 ${\times}$ 2.0 mm, I.D. 3 ${\mu}m$)을 이용하여 분리하였고, 이동상은 0.2% formic acid와 acetonitrile로 구성되었으며 유속은 150 ${\mu}L$/min으로 하였다. 크레아티닌과 내부표준물질은 [M+H]$^+$ precursor ion과 특징적인 product ion을 한 쌍으로 m/z 114.0${\rightarrow}$ 86.0과 m/z 117.0${\rightarrow}$ 89.1에서 모니터링하여 정량에 적합한 크로마토그램을 얻을 수 있었다. 측정불확도 평가에 앞서 정량분석시 측정값에 영향을 주는 인자들을 찾아내고 각각의 요소들이 측정결과에 어떤 영향을 주는가를 살펴보았다. 시료 희석, 검정 곡선, 재현성, 표준물질의 인자 순으로 측정불확도에 영향을 미치고 있음을 확인하였다. 실제 사람의 소변에서 크레아티닌 농도를 측정한 결과, 측정값에 대한 오차 범위의 상대불확도는 14.2%로 산출되었다.

중수로원전 방사선작업종사자의 공기중 삼중수소 섭취 후 뇨시료 제출 시간이 체내 삼중수소 농도에 미치는 영향 분석 (An Internal Tritium Concentration Analysis in Urine Samples as a Function of Submission Time after Airborne Tritium Intake at Korean Pressurized Heavy Water Reactors)

  • 김희근;공태영;정우태;김석태
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.184-189
    • /
    • 2009
  • 중수로원전의 방사선작업종사자는 방사선작업 종료 후에 뇨시료를 제출하여 공기중 삼중수소의 섭취에 따른 내부피폭 선량을 평가하고 있다. 이 경우 종사자가 제출한 뇨시료는 삼중수소가 체내에서 평형에 도달한 대표시료(Representative sample)라는 전제를 필요로 한다. 국제방사선방호위원회(ICRP)의 간행물과 삼중수소의 인체평형에 대한 캐나다의 실험결과에 의하면 체내로 유입된 삼중수소는 약 2-3시간 후에 평형에 도달한다고 기술하고 있다. 그런데 원전에서는 계획예방정비기간 동안 일시에 많은 작업이 진행되고 빈번한 종사자의 출입으로, 방사선작업 종료 후 제출하는 뇨시료는 섭취 후 평형에 도달하는 약 2시간 경과 이전에 제출하거나, 지연하여 제출하는 경우가 발생할 수 있다. 따라서 이 논문에서는 방사선작업 종료 후 종사자가 제출하는 시간대별 뇨시료 중의 삼중수소 농도를 측정하였고, 이를 근거로 체내 삼중수소의 농도에 대한 변화추이와 선량평가에 미치는 영향을 분석하였다. 그 결과 종사자의 뇨시료는 대부분 삼중수소 섭취 후 2시간 정도에 신체 내에서 평형에 도달하는 것으로 확인되었다.

성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립 (Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration)

  • 정수진;백승경;박선혜;손꽃잎;박용훈;이상기
    • 약학회지
    • /
    • 제57권5호
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Detection of Genital HPV Infection Using Urine Samples: a Population Based Study in India

  • Sabeena, Sasidharanpillai;Bhat, Parvati;Kamath, Veena;Mathew, Mary;Aswathyraj, Sushama;Devadiga, Santhosha;Prabhu, Suresha;Hindol, Maity;Chameetachal, Akhil;Krishnan, Anjana;Arunkumar, Govindakarnavar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1083-1088
    • /
    • 2016
  • Background: Cervical cancer is the second commonest cancer among Indian women and its association with human papilloma virus (HPV) is well established. This preventable cancer accounts for the maximum number of cancer related deaths among rural Indian women. Unlike in developed countries there are no organized cervical cancer screening programmes in India due to lack of resources and manpower. Objective: To detect genital HPV infection using urine samples among asymptomatic rural women in the age group of 18-65 years. Materials and Methods: The study area chosen was Perdoor village in Udupi Taluk, Karnataka State and all the women in the age group of 18-65 years formed the study cohort. A cross sectional study was conducted by house visits and 1,305 women were enrolled in the study. After taking written informed consent a data sheet was filled and early stream random urine samples were collected, transported to a laboratory at 4OC and aliquoted. Samples were tested using nested HPV PCR with PGMY09/11 and GP5+/6+ primers. Positive cases were genotyped by sequence analysis. Results: Study participants included 1,134 sexually active and 171 unmarried women with a mean age at marriage of 22.1 (SD=3.9) years. Study area showed high female literacy rate of 86.6%. Five urine samples tested positive for HPV DNA (0.4%). Conclusions: We found very low genital HPV infection rate among women from monogamous community. This is the first major population based study carried out among asymptomatic rural women to detect genital HPV infectio from Karnataka using urine samples.

Clinical Value of Dividing False Positive Urine Cytology Findings into Three Categories: Atypical, Indeterminate, and Suspicious of Malignancy

  • Matsumoto, Kazumasa;Ikeda, Masaomi;Hirayama, Takahiro;Nishi, Morihiro;Fujita, Tetsuo;Hattori, Manabu;Sato, Yuichi;Ohbu, Makoto;Iwam, Masatsugu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권5호
    • /
    • pp.2251-2255
    • /
    • 2014
  • Background: The aim of this study was to evaluate 10 years of false positive urine cytology records, along with follow-up histologic and cytologic data, to determine the significance of suspicious urine cytology findings. Materials and Methods: We retrospectively reviewed records of urine samples harvested between January 2002 and December 2012 from voided and catheterized urine from the bladder. Among the 21,283 urine samples obtained during this period, we located 1,090 eligible false positive findings for patients being evaluated for the purpose of confirming urothelial carcinoma (UC). These findings were divided into three categories: atypical, indeterminate, and suspicious of malignancy. Results: Of the 1,090 samples classified as false positive, 444 (40.7%) were categorized as atypical, 367 (33.7%) as indeterminate, and 279 (25.6%) as suspicious of malignancy. Patients with concomitant UC accounted for 105 (23.6%) of the atypical samples, 147 (40.1%) of the indeterminate samples, and 139 (49.8%) of the suspicious of malignancy samples (p<0.0001). The rate of subsequent diagnosis of UC during a 1-year follow-up period after harvesting of a sample with false positive urine cytology initially diagnosed as benign was significantly higher in the suspicious of malignancy category than in the other categories (p<0.001). The total numbers of UCs were 150 (33.8%) for atypical samples, 213 (58.0%) for indeterminate samples, and 199 (71.3%) for samples categorized as suspicious of malignancy. Conclusions: Urine cytology remains the most specific adjunctive method for the surveillance of UC. We demonstrated the clinical value of dividing false positive urine cytology findings into three categories, and our results may help clinicians better manage patients with suspicious findings.

VARIOUS NIR SAMPLE PRESENTATIONS FOR AGRICULTURAL PRODUCTS SUCH AS INTACT FRUITS, SINGLE GRAINS, VEGETABLE JUICE, MILK AND THE OTHERS

  • Kawano, Sumio
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1021-1021
    • /
    • 2001
  • Sample presentation, which means how to set samples to an NIR instrument, is very important in Near Infrared (NIR) Spectroscopy. When sample presentation is not suitable for the samples that you use, very good spectra can not be obtained even if you use a sophisticated NIR instrument. In my presentation, various NIR sample presentations for agricultural products such as intact fruits, single grains, vegetable juice and the others will be explained. In case of peaches with thin peel, the fiber optics of Interactance can be used. However, the fiber optics are not suitable for oranges with relatively thick peel. In this case, transmittance method is useful. As for a small sample such as single grains, a specially designed cell is needed. The cell in transmittance mode has been developed and then applied to single kernels of rice and soybean. In this case we also used the fiber optics. As regards liquid type of sample, a cuvette cell made of quartz in transmittance mode is popular. However, it is time-consuming to wash and dry it. In order to compensate this disadvantage the sample presentation using normal test tubes as sample cells have been developed and applied to milk, rumen juice and urine of a milking cow. An individual test tube can be used for each sample if you use the calibration equation with sample cell compensation. The test tube cell has also been applied to spinach juice for determination of undesirable constituents. It is concluded that sample presentation is most important for NIR Spectroscopy.

  • PDF

Detection of Human Papillomavirus in Male and Female Urine by Electrochemical DNA Chip and PCR Sequencing

  • Nilyanimit, Pornjarim;Wanlapakorn, Nasamon;Niruthisard, Somchai;Pohthipornthawat, Natkrita;Karalak, Anant;Laowahutanont, Piyawat;Phanuphak, Nittaya;Gemma, Nobuhiro;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권9호
    • /
    • pp.5519-5525
    • /
    • 2013
  • Background: Cervical cancer is the second most common cancer in Thai women after breast cancer. Currently, the Papanicolaou (Pap) smear is the recommended procedure for cervical cancer screening in Thailand, but only a relatively small percentage of women follow this screening program. An alternative method to detect HPV genotypes associated with cervical cancer is self-sampling of urine, which is a more widely accepted method. Our study aimed to evaluate the prevalence of HPV in Thai women using urine and cervical swabs and prevalence of HPV in Thai men using urine samples. Materials and Methods: Tumorigenic HPV detection was accomplished by electrochemical DNA chip and PCR/direct sequencing. In addition to HPV prevalence, we report the concordance between different methods and sample types. One-hundred and sixteen women and 100 men were recruited. Histological examination revealed normal cytology in 52 women, atypical squamous cells of undetermined significance (ASCUS) in 9, low-grade squamous intraepithelial lesions (LSIL) in 24, and high-grade squamous intraepithelial lesions (HSIL) in 31. One-hundred men were classified as heterosexuals (n=45) and homosexuals (n=55). Results: The most prevalent HPV genotype in our study was HPV16. The HPV detection rate was generally lower in urine samples compared with cervical samples. Overall, there was good agreement for the detection of carcinogenic HPV from female cervical samples between the DNA chip and PCR/sequencing, with 88.8% total agreement and a kappa value of 0.76. In male urine samples, the level of agreement was higher in heterosexuals compared with homosexuals. Conclusions: Further improvement is required to increase an overall yield of HPV DNA detection in urine samples before clinical application of a urine-based HPV screening program. The electrochemical DNA chip test is a promising technique for carcinogenic HPV detection.

노인요당 양성자의 질병관리에 대한 교육 및 추후 관리 양상에 관한 연구 (A Study on the Effects of Health Education and Self-Care Status on the Aged Diabetics)

  • 이선자;권연희
    • 한국보건간호학회지
    • /
    • 제2권2호
    • /
    • pp.99-116
    • /
    • 1988
  • This study examined the effect of Health Education on the aged. One of the Study objectives was to improve knowledge. attitude and self-care practice about diabetes of the aged who have responded positive in the urine sugar test. The other study objective was to find out factors influencing knowledge. attitude and self-care practice about diabetes. and the relationship among the three variables. The subjects, consisting of 45 positive responders in the urine sugar test, were selected from the elderly who attend elderly citizen center in southern part of Seoul Then they were divided into an experimental and a control group. The study design was set to compare the pre and post test data between the experimental and the control group with the measures of results from Health Education services including nursing care intervention programs on the aged diabetics. The first data collection was carried out in August. 1986 through questionaires and urine sugar testing. The second data collection was done in September, 1987 through the same methods. The results of the study are summarized as follows; 1. General characteristics of the subjects The experimental group has 9 females and 14 males and the control group has 12 females and 10 males. As for the educational level, more than half of the subjects in both group had completed at least 6 years of education. And there was no significant difference in urine sugar levels between the two groups. 2. The effect of Health Education on the extent of change in knowledge, attitude and self-care practice about diabetes was found to be significant. The first hypothesis that knowledge, attitude and self-care practice about diabetes in the aged will be unchanged by Health Education. was rejected by increased the three variables and decreased urine suger level in the experimental group. The second hypothesis that knowledge, attitude and self-care practice about diabetes wouldn't be concerned with each other, was rejected. That is. the three variables and urine sugar levels showed a significant positive relationship with each other but diabetic knowledge to urine sugar level had an insignificant positive relationship. The third hypothesis that the amount of learning Health Education will have no relationships with knowledge. attitude and self-care practice about diabetes. was rejected. That is, the more number of times an elderly person participated in Health Education. they increased their diabetic knowledge. attitude and self-care practice and decreased their urine sugar level. 3. Except for Health Education, an other factor influencing diabetic knowledge was educational level. And an other factor influencing the diabetic attitude was experience of the diagnosis of diabetes. 4. Except for Health Education. the other factors influencing self-care practice were experience of the diagnasis of diabetes, sex and experience of the hospitalization for diabetes. But factors influencing urine sugar level weren't found. Although the results seem to be plausible, this study is not without its problems. In paticular, the sample used is limited in its scope and size. So, more empirical work needs to be done for other diseases as well as diabetes before any general conclusions are to be made.

  • PDF