• Title/Summary/Keyword: Urban discharge

Search Result 321, Processing Time 0.026 seconds

Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas (장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정)

  • Joo, Jingul;Yoo, Doguen;Kim, Joonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.841-847
    • /
    • 2011
  • In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.

A Study on the River Discharge Measurement Techniques (하천유량 측정기법에 관한 연구)

  • 김성원;지홍기
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

Study on Water Level and Salinity Characteristics of Nakdong River Estuary Area by Discharge Variations at Changnyeong-Haman Weir(1) (창녕·함안보 방류량에 따른 하류지역 및 하구역의 수리환경특성에 관한 연구(1))

  • Kim, Tae-Woo;Yang, Hyun-Soo;Park, Byeong-Woo;Yoon, Jong-Sung
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.361-366
    • /
    • 2018
  • The present study analyzed the variation factors in inducing a salinity change using the existing observation network in the section between the Nakdong River Estuary Barrage and Changnyeong-Haman Weir, and also examined the seasonal changes in precipitation, salinity, and discharge. Furthermore, this study analyzed the causes of a salinity increase by collecting observational data during a period when abnormal salinity occurred, and further investigated the salinity transfer time in a section of approximately 5.3 km from the Nakdong River Estuary Barrage to Nakdong River Bridge to understand the behavioral characteristics of the salinity moving upstream. The study results would make it possible to control the increase in salinity and block salt water from moving upstream by understanding the salinity variation characteristics according to the discharge amount. This will provide stability in collecting water from various residential, agricultural, and industrial sources through water intake facilities scattered near the Nakdong River Estuary Barrage.

Development of head loss coefficient formula at surcharged four-way combining square manhole with variation of inlet flow (유입유량 변화를 고려한 과부하 4방향 사각형 합류맨홀에서의 손실계수 산정식 개발)

  • Jo, Jun Beom;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.12
    • /
    • pp.877-887
    • /
    • 2017
  • The energy losses due to surcharged flow at four-way combining manhole, which is mainly installed in the downstream of urban sewer system, is the main cause of inundation in urban area. Surcharged four-way combining manholes form various flow configuration such as straight through, T-type, and four-way manholes depending on variation of inflow discharge in inlet pipes. Therefore, it is necessary to analyze change of energy loss and estimate head loss coefficients at surcharged four-way combining manhole with variation of inflow discharge ratio. The hydraulic experimental apparatus which can change inflow ratios were installed to analyze the flow characteristics at four-way combining manhole. In this study, to calculate the head loss coefficient according to change of the inflow discharge ratios at the surcharged four-way combining square manhole, the discharge conditions of 40 cases which the inflow ratios of each inlet pipe were changed by 10% interval was selected. The head loss coefficient at surcharged square manhole showed the lowest value of 0.40 at the straight manhole and the highest value of 1.58 at the $90^{\circ}$ junction manhole. In the combining manholes (T-type and four-way), the head loss coefficients were calculated more higher as the lateral flow rate was biased. The contour map of head loss coefficient range was constructed by using the estimated head loss coefficients and the empirical formula of head loss coefficients was derived to consider the variation of inflow discharge ratios at the surcharged square manhole. The empirical formula could be applied to the design and assessment of the urban drainage system.

Estimation of Flow Loads for Landcover Using HyGIS-SWAT (HyGIS-SWAT을 이용한 토지피복도에 따른 유출부하 평가)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.2
    • /
    • pp.28-39
    • /
    • 2011
  • This study estimates the characteristics of flow loads by classification items of the Ministry of Environment and by land cover change using HyGIS-SWAT. The result of analyzing the land cover change using the classification items shows that the urban area and the farmland area in Mishim-cheon and Gap-cheon are expanding while the forest area is decreasing. The result of analyzing the characteristics of classification items shows that peak discharge increases and total yearly discharge decreases in Mushim-cheon. The result of analyzing the characteristics by data-construction period shows that peak discharge decreases but total discharge increases in Gap-cheon. Three land cover change scenarios are applicable to the expansion of urban area and farmland area. According to the result of application, urbanization influences and Farmland area expansion influences increase peak discharge, total yearly discharge and sediment concentration.

Simulation of Turbid Water in the Stratified Daecheong Reservoir during Gate Operation (댐 배수조작에 따른 저수지내 탁수변화 모의 - 대청댐을 대상으로 -)

  • Lee, Jae-Yil;Seo, Se-Deok;Lee, Gyu-Sung;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.377-386
    • /
    • 2009
  • Due to severe flooding, the long-term residence of turbidity flows within the stratified Daecheong Reservoir have lengthened. A long-term residence of turbidity flows within the stratified Daecheong Reservoir after floods has been major environmental issue. The objective of this study was to assess the impact to water supply from the hydrodynamics and turbidity outflow. Two gate operation scenarios were investigated. Scenario A refers to gate operations according to rainfall events, and scenario B refers to gate operations according to inflow. From the results of secenario A, the SS concentrations decreased from 0.44mg/l to 0.54mg/l at the front of the dam, whereas SS concentrations increased from 0.24mg/l to 1.24mg/l at the intake points at Munhi and Daejeon. From the results of scenario B, the SS concentrations decreased from 0.61mg/l to 0.83mg/l at the front of Dam; howeve, SS concentrations also decreased from 0.16mg/l to 0.48mg/l at the intake points at Munhi and Daejeon. It seems that it may be more efficient to control turbidity by creating additional outflows of generated discharge after intensive rainfalls than not.

The Formation and Development Process of Yanji Urban Area in Modern Ages(1870-1949) (근대 연길도심지구의 형성과 발전과정)

  • Park, Sae-Young;Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.2
    • /
    • pp.72-79
    • /
    • 2006
  • This study is to find out formation and development process of urban area in modern ages(1870-1949) focused Yanji city in the east-northern area in china. After the discharge of confinement in the late 19 century, the settlements were formed around east area, that is, the present Yanji urban area. The japanese consular office had been moved in east area since the beginning of the early 20 century, and so, the existing residents moved to west area. And the military and administrative facilities were located on the urban outskirts. After the September 18th Incident on 1932, Yanji had been constructed with the strategic center area under the urban planning. The administrative facilities of those days had been altered to he functional branches and educational facilities, and become the basis of development of Yanji city.

  • PDF

Identification of operating parameters in auto-discharging filter system for treatment of urban storm water (자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출)

  • Kim, Sun-Hee;Gwon, Eun-Mi;Pak, Sung-Soon;Joh, Seong-Ju;Lim, Chea-Hoan;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

Analysis of Flood Characteristics for A Small Stream in Apartment Complex of Urban Watershed (도시 유역 아파트 단지내 소하천의 홍수특성 분석)

  • Kwak, Jae Won;Ahn, Kyoung Soo;Park, Do Ho;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.9 no.3
    • /
    • pp.25-34
    • /
    • 2007
  • We analyzed flood runoff and flood characteristics of an small urban river basin which is in an apartment complex in Yewol-Dong, Buchun-Si, Gyunggi-Do. This discharge normally flows a little by intercepting sewer and interception of pollutants. However in flood period it looks like risk of flood damage by high flood discharge and increase of flood elevation. After appling the analysis model on urban runoff, using the GIS data and cross section at the basin, and then we studied the degree of flood control safety at the basin through forecasting flood elevation. Eventually, there are the flood risks from the River structure for Multi-functional Urban river as well as the river safety. As flood runoff analysis in urban, we need to consider risks which are drainage depth and other.

  • PDF

A study of the Effect of groin on the Water Quality in the Urban River (방사보가 도시하천수질에 미치는 영향에 관한 연구)

  • Cho, Hong-je;Kim, ill-gwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.81-90
    • /
    • 1998
  • The purpose of this study was to analyze the effect of the groin which was constructed in the down stream of urban river for the prevention of sedimentation on the improvement of the water quality. We studied on the groin in the downstream of Taehwa River constructed to keep the navigation depth of Ulsan day, and used the measured data of the water quality and river discharge. In order to analyze the charge of the water quality due to the groin Que12E model was applied, and BOD and DO was examined. The analysis showed that removal of the groin would not have significant effect on the improvement of the water quality, rather, interception of the pollution source coming into the upstream of the groin would be more influential on the improvement of the water quality. Therefore, It was concluded that to improve the water quality in mild bottom slop of tidal river, interception of the pollution source and river maintenance discharge should precede.

  • PDF