• Title/Summary/Keyword: Urban Dynamics

Search Result 287, Processing Time 0.022 seconds

Validation of applying Canopy model to predict wind environment of pedestrian level by CFD simulation (보행자 레벨의 풍환경 예측 시 Canopy Model을 적용한 CFD 시뮬레이션 타당성 검증)

  • Jung, Su-Hyeon;Hong, In-Pyo;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.345-353
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high-rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However the results show differences between CFD and measurement. The reason for the difference is that conventional CFD simulation couldn't consider the effect of trees, shrubs and plants which affect the wind environment. Canopy model is a solution to solve the limitation of CFD analysis. In this paper, the canopy model to predict wind environment of pedestrian level by CFD simulation will be proposed and the validity will be analyzed by comparison of measurement and CFD prediction.

  • PDF

Development and application of an assessment tool for outdoor thermal environment (옥외 온열환경 평가를 위한 복사 연성 CFD 해석기법의 개요)

  • Lim, Jong-Yeon;Chang, Hyun-Jae;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.45-55
    • /
    • 2009
  • Deterioration of the outdoor thermal environment in urban areas has become worse and worse due to the urbanization and overpopulation, etc. Most of existing researches about thermal environment are focused on the indoor environment in which the radiation heat exchange is relatively constant. However, the outdoor thermal environment is changed with time passages, because the thermal environment is highly effected by solar radiation. Thus, to simulate the outdoor thermal environment with accuracy, the solar radiation calculation should be considered, and the radiation heat exchange between building surface and ground surface should be calculated. The purpose of this study is to develop the simulator that can be possible to evaluate the outdoor thermal environment and pedestrian thermal comfort. In this paper, a new method which is coupled with convective heat transfer simulation and radiative heat transfer simulation will be proposed. And the coupled simulation method will be described through case study for outdoor thermal environment. From the results of simulation, the coupled simulation proposed in this study can assess the outdoor thermal environment with accuracy.

Derivation of New Box Model to Analyze the Air Pollution Trends in a Metropolitan Area (대도시 대기오염 추세 분석을 위한 새로운 박스모델의 유도)

  • Kim Seogcheol;Joh Seunghun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.377-397
    • /
    • 2005
  • A new box model is proposed to describe the dynamic trend of the spatially averaged concentrations of pollutants over a large urban area such as metropolitan Seoul. Being averaged temporally and spatially over a thresh-hold scales, the dynamics of the pollutant concentration becomes simple enough that the governing equation can be expressed in an explicit algebraic form as a function of several meteorological factors and the pollutant emission rate. The single most important meteorological factor is the wind speed dominating the daily variations of the pollutant concentrations. Given the meteorological data from the surface station in the metropolitan Seoul, the model concentration shows excellent agreement with observations from January 1, 1990 to December 31, 2000: the modeling uncertainty, for example, of $NO_2$ concentrations, defined as mean differences between the model concentrations and observations is $16\%$ of the model concentrations. Even for $PM_{10}$ of which secondary sources are considered to be very important and simple box model is irrelevant to, the model performance turns out good, modeling uncertainty being about $32\%$.

A Local Asset Based Regeneration Process of Gamcheon Culture Village Busan (부산 감천문화마을의 지역자산 기반 재생과정 연구)

  • Lee, Yeun Sook;Park, Jae Hyun
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.111-120
    • /
    • 2014
  • In the late 20th century, Korea has accelerated urban sprawl and demolition based redevelopment without considering local characteristics. As a result, quantitative supplement of housing has been saturated and has pushed revitalization especially. The purpose of this research is to delineate the local asset based regeneration of Gamcheon Culture Village Busan. The research methods are field visit, site observation, in-depth interview, library and internet research, data were collected and analyzed with the contents analysis techniques. As results, elements of hardware, software and humanware resources and the dynamics of the whole process such as how the resources connected and utilized, and how the external resources have been converged into these to regenerate Gamcheon Culture Village in diverse dimensions, such as cultural, social, economical and physical one were analysed. This research is expected to share the wisdom of revitalizing with collaborations. Through enhancing negative resources of decayed area to positive ones, the case produced the synergy.

Study on Energy Saving Possibilities through Analysis of Environment Control Elements & Natural Ventilation Performance using the CFD & Measurement (CFD와 실측을 이용한 환경제어요소 도입 및 주택 자연환기 성향 검토를 통한 에너지 절감가능성 고찰)

  • Oh, Byoungchull;Lee, Sunyoung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • Heat island is caused by changes of land coverage structure of cities and use of energy in buildings. As a result energy use in buildings get to increase further followed by rising of GHG emission and deteriorating climate change. Eco-friendly housing complex is a kind of plan that applies environmental control elements like water and green spaces to housing complex. With these methods, it can be expected to create thermal environment of indoor and outdoor. In this paper quantitative examination is studied on using CFD to find out the effects of river, water permeable, parks and planting on thermal environment. And by comparing field measurements with CFD results which are aimed to development phase housing complex, feasibility and usability of the CFD analysis results are confirmed. And also, analysis on the ventilation performance followed by natural ventilation system is analyzed by selecting one building in housing complex. Based on the results, the possibilities of energy reduction through making thermal environment and applying natural ventilation are studied. With these outcomes, creating thermal conditions and using natural ventilation would be contributed to GHG reduction.

A Nonlinear Observer Design for Estimating State-of-Charge of Lithium Polymer Battery (리튬폴리머 배터리 잔존충전용량 추정을 위한 비선형 관측기 설계)

  • Yoo, Seog-Hwan
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.300-304
    • /
    • 2012
  • This paper presents a nonlinear observer design method for SOC(state-of-charge) estimation of Lithium polymer battery cell. The dynamic equation of the battery cell is modeled as a simple RC electrical circuit with a nonlinear voltage source and the parameters are obtained via nonlinear optimization. Using the sum of squares decomposition, the observer gain is designed such that the error dynamics is asymptotically stable and the decay rate is below the prescribed value. In order to illustrate the performance of the observer, a computer simulation is performed using the experimental data with the UDDS(urban dynamometer driving schedule) current profile.

A Design Criteria of Ventilation Holes to Reduce a Vapor Condensation on the Balcony Walls in Apartment Housings

  • Lee, Jong-Sung;Kim, Jong-Yeob;Hwang, Ha-Jin;Lee, Sung-Bok
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.463-469
    • /
    • 2011
  • LH has installed sashes to the balcony to save energy and increase residential space. Then, it is very difficult to protect a condensation of vapor on the walls in the winter time, because the space is closed and the wall surface temperature becomes very low in a balcony. We have tried to get the optimal thermal design methods to reduce the condensation on the walls. The one of the chosen method is to make holes on the walls, and then the condensation shall be reduce because the dew point temperature will be lower due to the effect of dehumidify. In this case, it is just necessary to find as like that how many holes should be perforated through the wall, what's their size, and where is their positions. In this study, a computational fluid dynamics was applied to analyze the temperature, the pressure and the velocity distribution for an incompressible flow in the balcony spaces. And field tests were also carried out to get the data to compare to the simulation results. Finally the design criteria of the ventilation holes in the balconies was suggested by analysis of the computer simulation models.

CE-OLSR: a Cartography and Stability Enhanced OLSR for Dynamic MANETs with Obstacles

  • Belghith, Abdelfettah;Belhassen, Mohamed
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.1
    • /
    • pp.270-286
    • /
    • 2012
  • In this paper, we propose a novel routing protocol called the Cartography Enhanced OLSR (CE-OLSR) for multi hop mobile ad hoc networks (multi hop MANETs). CE-OLSR is based on an efficient cartography gathering scheme and a stability routing approach. The cartography gathering scheme is non intrusive and uses the exact OLSR reduced signaling traffic, but in a more elegant and efficient way to improve responsiveness to the network dynamics. This cartography is a much richer and accurate view than the mere network topology gathered and used by OLSR. The stability routing approach uses a reduced view of the collected cartography that only includes links not exceeding a certain distance threshold and do not cross obstacles. In urban environments, IEEE 802.11 radio signals undergo severe radio shadowing and fading effects and may be completely obstructed by obstacles such as buildings. Extensive simulations are conducted to study the performances of CE-OLSR and compare them with those of OLSR. We show that CE-OLSR greatly outperforms OLSR in delivering a high percentage of route validity, a much higher throughput and a much lower average delay. In particular the extremely low average delay exacerbated by CE-OLSR makes it a viable candidate for the transport of real time data traffic in multi hop MANETs.

Concept Design of a Parallel-type Tuned Mass Damper - Tuned Sloshing Damper System for Building Motion Control in Wind

  • Lee, Chien-Shen;Love, J. Shayne;Haskett, Trevor C.;Robinson, Jamieson K.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.2
    • /
    • pp.93-97
    • /
    • 2021
  • Supplementary damping systems, such as tuned mass dampers (TMDs) and tuned sloshing dampers (TSDs) - also known as tuned liquid dampers (TLDs) - have been successfully employed to reduce building motion during wind events. A design of a damping system consisting of a TMD and two TSDs performing in unison has been developed for a tall building in Taiwan to reduce wind-induced motion. The architecturally exposed TMD will also be featured as a tourist attraction. The dual-purpose TSD tanks will perform as fire suppression water storage tanks. Linearized equivalent mechanical TSD and TMD models are coupled to the structure to simulate the multi-degree of freedom system response. Frequency response curves for the structure with and without the damping system are created to evaluate the performance of the damping system. The performance of the combined TMD-TSD system is evaluated against a conventional TMD system by computing the effective damping produced by each system. The proposed system is found to have superior performance in acceleration reduction. The combined TMD-TSD system is an effective and affordable means to reduce the wind-induced resonant response of tall buildings.

Experimental and Computational Investigation of Wind Flow Field on a Span Roof Structure

  • K B Rajasekarababu;G Vinayagamurthy;Ajay Kumar T M;Selvirajan S
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.287-300
    • /
    • 2022
  • Unconventional structures are getting more popular in recent days. Large-span roofs are used for many structures, such as airports, stadiums, and conventional halls. Identifying the pressure distribution and wind load acting on those structures is essential. This paper offers a collaborative study of computational fluid dynamics (CFD) simulations and wind tunnel tests for assessing wind pressure distribution for a building with a combined slender curved roof. The hybrid turbulence model, Improved Delayed Detached Eddy Simulation (IDDES), simulates the open terrain turbulent flow field. The wind-induced local pressure coefficients on complex roof structures and the turbulent flow field around the structure were thus calculated based upon open terrain wind flow simulated with the FLUENT software. Local pressure measurements were investigated in a boundary layer wind tunnel simultaneous to the simulation to determine the pressure coefficient distributions. The results predicted by CFD were found to be consistent with the wind tunnel test results. The comparative study validated that the recommended IDDES model and the vortex method associated with CFD simulation are suitable tools for structural engineers to evaluate wind effects on long-span complex roofs and plan irregular buildings during the design stage.