• 제목/요약/키워드: Upper-air observations

검색결과 30건 처리시간 0.023초

Vertical Profiles of Meteorological Parameters over Taegu City

  • Ahn, Byung-Ho;Kwak, Young-Sil
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제22권1호
    • /
    • pp.24-32
    • /
    • 1994
  • A special upper-air observation including airsonde and pibal observations was performed to investigate the characteristics features of the vertical distribution of the meteorological elements over Taegu on a selected clear day of each season from October 1991 to August 1992. The diurnal and seasonal variations of the vertical profiles of air temperature and mixing ratio were obtained from airsonde observations and wind speed and direction from pibal observations. The results of these special upper-air observations are as follow : The diurnal variation of the vertical distribution of air temperature reveals the characteristic features associated with the atmospheric boundary layer. All case days, except for the summer season, show upper-level inversion layer which influenced by surface high, and surface inversion layer produced by radiative cooling. The diurnal variation of mixing ratio shows the maximum vale at 1500 LST in both the upper and low levels, and is larger on the lower level than the upper level. The mixing ratio of the lower level is larger than that of the upper level. On the average the mixing ratio decrease with the height, and is the wettest on the summer case day and the driest on the winter case day. The diurnal variation of the wind velocity and direction are variable in the lower level with time and height, while they are steady in the upper level. On the average, the wind direction is southerly or southeasterly for the summer case day, westerly or northwesterly for the spring and fall case days, and northerly or northwesterly for the winter case day.

  • PDF

고층기상관측자료를 이용한 바람장 개선 효과 연구 (The Effects of Data Assimilation on Simulated Wind Fields Using Upper-Air Observations)

  • 정주희;권지혜;김유근
    • 한국환경과학회지
    • /
    • 제16권10호
    • /
    • pp.1127-1137
    • /
    • 2007
  • We focused on effects on data assimilation of simulated wind fields by using upper-air observations (wind profiler and sonde data). Local Analysis Prediction System (LAPS), a type of data assimilation system, was used for wind field modeling. Five cases of simulation experiments for sensitivity analysis were performed: which are EXP0) non data assimilation, EXP1) surface data, EXP2) surface data and sonde data, EXP3) surface data and wind profiler data, EXP4) surface data, sonde data and wind profiler data. These were compared with observation data. The result showed that the effects of data assimilation with wind profiler data were found to be greater than sonde data. The delicate wind fields in complex coastal area were simulated well in EXP3. EXP3 and EXP4 using wind profiler data with vertically high resolution represented well sophisticated differences of wind speed compared with EXP1 and EXP2, this is because the effects of wind profiler data assimilation were sensitively adjusted to first guess field than those of sonde observations.

객관분석기법에 의한 바람장 모의의 초기입력장 변화 효과 분석 (The Effects of the Changed Initial Conditions on the Wind Fields Simulation According to the Objective Analysis Methods)

  • 김유근;정주희;배주현;권지혜;서장원
    • 한국환경과학회지
    • /
    • 제15권8호
    • /
    • pp.759-774
    • /
    • 2006
  • We employed two data assimilation techniques including MM5 Four Dimensional Data Asssimilation (FDDA) and Local Analysis and Prediction System (LAPS) to find out the effects of the changed inetial conditions on the wind fields simulation according to the objective analysis methods. We designed 5 different modeling cases. EXP B used no data assimilation system. Both EXP Fl using surface observations and EXP F2 with surface and upper-air observations employed MM5 FDDA. EXP Ll using surface observations and EXP L2 with surface and upper-air observations used LAPS. As results of, simulated wind fields using MM5 FDDA showed locally characterized wind features due to objective analysis techniques in FDDA which is forcefully interpolating simulated results into observations. EXP Fl represented a large difference in comparison of wind speed with EXP B. In case of LAPS, simulated horizontal distribution of wind fields showed a good agreement with the patterns of initial condition and EXP Ll showed comparably lesser effects of data assimilation of surface observations than EXP Fl. When upper-air observations are applied to the simulations, while MM5 FDDA could hardly have important effects on the wind fields simulation and showed little differences with simulations with merely surface observations (EXP Fl), LAPS played a key role in simulating wind fields accurately and it could contribute to alleviate the over-estimated winds in EXP Ll simulations.

현업 국지모델기반 2018년 여름철 기상 1호 특별 고층관측자료의 관측 민감도 실험 (Observing Sensitivity Experiment Based on Convective Scale Model for Upper-air Observation Data on GISANG 1 (KMA Research Vessel) in Summer 2018)

  • 최다영;황윤정;이용희
    • 대기
    • /
    • 제30권1호
    • /
    • pp.17-30
    • /
    • 2020
  • KMA performed the special observation program to provide information about severe weather and to monitor typhoon PRAPIROON using the ship which called the Gisang 1 from 29 June 2018 to 4 July 2018 (UTC). For this period, upper-air was observed 21 times with 6 hour intervals using rawinsonde in the Gisang 1. We investigated the impact of upper-air observation data from the Gisang 1 on the performance of the operational convective scale model (we called LDAPS). We conducted two experiments that used all observation data including upper-air observation data from the Gisang 1 (OPER) and without it (EXPR). For a typhoon PRAPIROON case, track forecast error of OPER was lower than EXPR until forecast 24 hours. The intensity forecast error of OPER for minimum sea level pressure was lower than EXPR until forecast 12 hours. The intensity forecast error of OPER for maximum wind speed was mostly lower than EXPR until forecast 30 hours. OPER showed good performance for typhoon forecast compared with EXPR at the early lead time. Two precipitation cases occurred in the south of the Korean peninsula due to the impact of Changma on 1 July and typhoon on 3 July. The location of main precipitation band predicted from OPER was closer to observations. As assimilating upper-air data observed in the Gisang 1 to model, it showed positive results in typhoon and precipitation cases.

현열 플럭스 추정에 의한 대류 혼합층 고도의 산출 (Calculation of the Convective Mixed Layer by Estimation of Sensible Heat Flux)

  • 김용국
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.639-645
    • /
    • 1998
  • A Jump model was evaluated for the calculation of hourly mixing height and mean potential temperature within the height. The Sump model was modified for estimation of downward heat fluxes by mechanical convections and surface heat fluxes. The surface heat fluxes were estimated from routine weather data such as solar radiation and air temperature. Total of 8 upper-air data observed at 0000UTC and 0600UTC in Osan station during April 23 to 26, 1996 were analyzed, and compared to the model results in detail. The calculated mixing heights and potential temperatures within the height were comparable to the observations, but some differences were showed. The calculated mixing heights were generally higher than observations. And, when variations of wind directions were large, the large difference of potential temperature was occurred. From the results, it was important to note that vortical motions and advections of air masses would affect to the growth of the mixing height.

  • PDF

솔라패널을 이용한 라디오존데 온도센서의 일사보정 (Compensation for The Solar Radiation Effect of Radiosonde's Temperature Sensor Using Solar Panel)

  • 박명석;이진욱;정세진;장재원
    • 대기
    • /
    • 제29권3호
    • /
    • pp.283-294
    • /
    • 2019
  • For the upper air observations, a temperature measurement using radiosonde is a common method, and the compensation of solar radiation effects in the radiosonde temperature sensor is an important factor. In this paper, we present various experiments and compensation methods of the radiosonde temperature sensor to overcome the errors caused by the movement of the radiosonde rotation, etc. The methods and procedures of this study are as follows. First, we used the solar simulator to analyze the temperature variation and solar effect of the temperature sensor in the radiosonde according to the insolation. We also analyzed the temperature variation and solar effect of the temperature sensor according to the incident angle between the solar simulator and radiosonde. Second, we measured and analyzed solar radiation absorbed by solar cells attached to radiosonde. Third, we present combined compensate solution of the first and the second experiment results, to overcome errors caused by insolation effects in the radiosonde temperature sensors. Fourth, we compared that the reference temperature in similar environment with the upper air conditions, to verify the new radiated compensation performance of the radiosonde temperature sensor. Finally, the radiosonde fabricated in this study was raised to the atmosphere, and the laser correction algorithm proposed through experiments was reviewed. As a result of the radiosonde SRS-10 produced in this study, the temperature deviation from Vaisala RS92 was $0.057^{\circ}C$ in nighttime observation, $0.17^{\circ}C$ in daytime observation, It is expected that the GRUAN under WMO will be able to obtain a high test rating of 5.0.

기상드론을 이용한 보성 지역 기상 인자의 연직 측정 및 분석 (Vertical Measurement and Analysis of Meteorological Factors Over Boseong Region Using Meteorological Drones)

  • 정지효;신승숙;황성은;이승호;이승협;김백조;김승범
    • 한국지구과학회지
    • /
    • 제41권6호
    • /
    • pp.575-587
    • /
    • 2020
  • 기상현상관측은 기상청에서 다양한 방법(지상, 고층, 해양, 항공, 등)으로 관측되고 있다. 하지만, 인간생활에 많은 영향을 미치는 대기경계층 관측에는 한계가 있다. 특히, 존데 또는 항공기를 이용한 기상관측은 경제적인 측면에서 상당한 비용이 필요하다. 따라서 본 연구의 목적은 기상드론을 이용하여 국지기상현상 중 해륙풍 연직분포에 대한 기상 인자들을 측정하고 분석하는 것이다. 해륙풍의 공간적 분포를 연구하기 위해 보성지역 표준기상관측소의 보성종합기상탑을 포함한 다른 세 지점(해안가, 산기슭, 산중턱)에 동일한 통합기상센서를 각 드론에 탑재하였다. 2018년 8월 4일 1100 LST부터 1800 LST까지 30분 간격으로 최대 400 m 고도까지 기온, 상대 습도, 풍향, 풍속, 기압의 연직 프로파일 관측이 수행되었다. 기온, 상대 습도, 기압에 대한 기상현상의 공간적 특성은 네 지점에서 보이지 않았다. 강한 일사량 시간대에 중간지점(~100 m)에서 강한 바람(~8 m s-1)이 관측되었고, 오후에는 풍향이 내륙지역의 상층부터 서풍으로 바뀌었다. 기상드론을 이용하여 관측한 하부 대기층의 분석결과는 보다 정확한 기상예보 향상에 도움이 될 것으로 기대된다.

Development Mechanisms of Summertime Air Mass Thunderstorms Occurring in the Middle Region of South Korea

  • Kim, K.E.;Heo B.H.;Lee, H.R.;Min, K.D.
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제23권1호
    • /
    • pp.34-38
    • /
    • 1995
  • A diagnostic study on the summertime air mass thunderstorms occurring in the middle region of South Korea was made by analyzing the data of surface and upper air observations as well as the surface and upper level weather charts. The key parameters used in the present study are the amount of precipitable water below 850 hPa level, the vertical profiles of water vapor content and wind, and both the temperature difference and the equivalent potential temperature difference between 850 hPa and 700 hPa levels. It is found from this study that the summertime air mass thunderstorms in the middle region of South Korea can be classified into two distinct types, type I and type II. The thunderstorms of type I occur under the atmospheric conditions of high moisture content, low vertical wind shear in low levels, and conditional instability between 850 hPa and 700 hPa levels. On the other hand, the thunderstorms of type II occur under the atmospheric conditions of less moisture content, higher wind shear and conditional instability. Furthermore, our study suggests that atmospheric instability and the amount of water vapor below 850 hPa level are complementary in the development of air mass thunderstorms. The complementary nature between these two parameters may be an explanation for the thunderstorm development in the areas of low atmospheric water vapor content such as the plains of eastern Colorado.

  • PDF

집중관측을 통한 서해연안의 대기 수직구조 특성 (On the Characteristics of Vertical Atmospheric Structure in the Western Coastal Region through the Intensive Observation Period)

  • 문승의;노재식
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.335-348
    • /
    • 1998
  • The intensive meteorological observations including pibal balloon at Ungcheon, airsonde and 10m meteorological tower observations at Gulup-Do, where are located In the western coastal region, are taken to Investigate the characteristics of the upper and lower atmospheric structure and the local circulation pattern during the period of 17 to 22 September 1996. The diurnal variations of weather elements(i.e. air temperature, humidity, pressure, and Und speeds at Gulup-Do are analyzed and discussed with those at four inland meteorological stations. The vertical profiles of wind vector, ortho- gonality(Ω), and shear obtained from the pibal obsenrations are also presented to examine the change of wand structure according to the synoptic-scale pressure system's movement. The diurnal temperature changes at Gulup-Do are more sensitive than that of Inland meteorological stations In case of the mow of southwesterlies but are not dominant due to the ocean effect under the Influence of relatively cold northerlies. A well defined mixed layer Is developed from the 500m to the maximum 1700m with a significant capping Inversion layer on the top of it. It can be found from the vertical profiles of wind vector that the wind become generally strong at the interface heights between cloud lay- ers and non-cloud layers. The maximum Und shear Is appeared at the bel각t where the varlauon of wand direction Induced by the passage of synoptic-scale pressure system Is accompanied with the In- crease of Und speed. Based on the wind orthogonality, the change of wind direction with height is more complicated In cloudy day than In clear day. In case of a fair weather, the change of wand direction is showed to be at around 2km.

  • PDF

경북지역에서 관측된 야간 대기경계층의 특성 (Characteristics of Nocturnal Boundary Layer Observed in Kyungpook Province)

  • 권병혁
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.329-336
    • /
    • 2001
  • Characgcteristics of nocturnal boundary layer(NBL) were analyzed by the upper-air observations data using with the airsonde and pilot balloons from 1994 to 1999 in Kyungpook province. The automate weather boundary layer can become stably stratified when the surface is cooler than the air. Stable nocturnal boundary layer height were estimated from the top of surface stable layer where the vertical gradient of temperature and mixing ratio tend to zero or negative. The depth of the stable nocturnal boundary layer depended largely on the thermal effect rather than the wind effect at nighttime. The NBL was more developed on the land than on the coastal region. The stability index (bulk Richardson number) showed that the NBL was stable when the wind was weak and the vertical gradient of the temperature was strong. The heat budget in the NBL was studied by considering the effect of the radiative and the cooled by both the longwave radiative flux and the divergence of the heat flux, while NBL under the cloudy sky the longwave radiative flux played a role of the warming. It was noted that the heat was not conserved in both cases. To complete the heat budget in the NBL the warming/cooling by advection and subsidence must be considered.

  • PDF