• 제목/요약/키워드: Upper arm

검색결과 722건 처리시간 0.031초

팔 내리기 동작 시 시각적 바이오피드백 훈련이 전거근과 상부 승모근의 근활성도에 미치는 영향 (Visual Biofeedback to Monitor Serratus Anterior and Upper Trapezius Muscle Activities During Arm Lowering)

  • 하성민;민경진;최홍식
    • 한국전문물리치료학회지
    • /
    • 제15권2호
    • /
    • pp.38-43
    • /
    • 2008
  • To reduce winging scapula, various exercise protocols have been widely used by clinicians. Selective serratus anterior strengthening, and restoring balanced function, are especially recommended to reduce winging scapula. The purpose of this study was to investigate visual biofeedback using a real time video camera display system for monitoring scapular winging during arm lowering. For this study, 13 males with winging scapular were recruited during arm lowering. Electromyography (EMG) activity was recorded from the serratus anterior (SA) and upper trapezius (UT) of the right side and compared with normal EMG activity using a paired t-test. The study showed, through visual biofeedback, that EMG activity significantly increased in the SA and significantly decreased in the UT (p<.05). These results suggest that visual biofeedback can be recommended as an effective method for scapular eccentric control, to prevent scapular winging during arm lowering.

  • PDF

상지재활로봇의 팔힘측정용 2축 힘센서 설계 (Design of a Two-Axis Force Sensor for Measuring Arm Force of an Upper-Limb Rehabilitation Robot)

  • 김갑순
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.137-143
    • /
    • 2015
  • This paper describes the design of a two-axis force sensor with two step plate beams for measuring forces in an upper-limb rehabilitation robot. The two-axis force sensor is composed of a Fz force sensor and a Ty torque sensor. The Fz force sensor measures the force applied to a patient's arm pushed by a rehabilitation robot and the force of patient's arm. The Ty torque sensor measures the torque generated by a patient's arm motion in an emergency. The structure of sensor is composed of a force transmitting block, two step plate beams and two fixture blocks. The two-axis force sensor was designed using FEM (Finite Element Method), and manufactured using strain-gages. The characteristics test of the two-axis force sensor was carried out. as a test results, the interference error of the two-axis force sensor was less than 1.24%, the repeatability error of each sensor was less than 0.03%, and the non-linearity was less than 0.02%.

Changes in Back Body Surface Measurements for Dynamic Postures in the Form of Baseball Batting Motion with a 3D body Scanning

  • Shin, Saemi;Chun, Jongsuk
    • International Journal of Human Ecology
    • /
    • 제14권1호
    • /
    • pp.41-55
    • /
    • 2013
  • The purpose of this study was to analyze human upper body surface changes at the shoulder and back area. The body surface data were analyzed in terms of muscle and bone displacement in dynamic postures. Body surface data were collected with a 3D body scanner. The body surface was scanned at the static and four baseball batting postures. The body surface dimensions over the deltoids, scapulae and trapezius were measured. The results show that the vertical measurements of the deltoids increased by 20%. The horizontal measurements of the axilla of the back increased. The surface of the trapezius was elongated by over 10%, and the lower back musculature was elongated by about 50%. The results of this study showed that changes in back body surface caused by upper arm movements. It was influenced by the deltoid articulated with the humeri and the scapulae and trapezius. These body surface changes caused by muscle activities and ranges of motion can be used to design functional clothing.

퍼프슬리브 블라우스의 어깨길이와 퍼프량의 변화(變化)에 따른 시각적(視覺的) 효과(效果) (The Visual Effects by Variation of the Shoulder Length and Puff Volume in Puff Sleeve Blouse)

  • 구미란;이정순
    • 패션비즈니스
    • /
    • 제11권4호
    • /
    • pp.82-91
    • /
    • 2007
  • The purpose of this study is to evaluate the differences of visual effects by variations in the shoulder length and puff volume of the puff sleeve blouse. The stimuli are 21 samples: 3 variations of the shoulder length and 7 variations of the puff volume. The data has been obtained from 40 fashion design majors. The data has analyzed by Frequency, Factor Analysis, ANOVA, Scheffe's test and MCA method. The result of the study are as follows. The visual effects by the shoulder length and puff volume are composed of 4 factors : the width of the upper body, the shape of the breast part, the shape of the neck part and the shape of the upper arm. In these factors, the width of the upper body is estimated by most important factor. In view of the visual effects by variation of the shoulder length, the shorter shoulder length goes, the more positive visual image comes in the shape of the breast part. In comparison of the differences of visual effects by the 7 variations of puff volume, the arm looks thin and long when the puff volume goes enough and the breast part has a better visual assesment in case the puff volume goes poor. In the interaction effects between the shoulder length and puff volume, the shoulder length have significant differences in the shape of the breast part, the shape of the neck part and the shape of the upper arm and puff volume has significant difference in the width of the upper body.

의복 원형의 기능성에 관한 인간공학적 연구 (An Ergonomic Study on the Function of the Basic Pattern of Clothing -On the Expansion and Contraction of the Skin Surface of the Upper Body-)

  • 함옥상
    • 대한가정학회지
    • /
    • 제17권4호
    • /
    • pp.1-14
    • /
    • 1979
  • The functional problems of the basic pattern of clothing are a matter of the first importance to clothing construction. Therefore, the ergonomic analysis of the expansion and contraction of the upper body surface, due to motion, has become required. thus in order to obtain the measurements and rate of expansion and contraction of the upper body surface following from its motions, the development figure of " Shell" and somatometry were employed. The results obtained through the investigation can be summarized as follows : 1) According to the developmental figures of "Shell" the latitudes centering around the shoulder line present contractive tendencies by arm movement. The longitudes around the center back waist length are expansive tendencies when bent forward. In the case of a 15$^{\circ}$ lean backward posture, the longitudes around the center front waist length are expansive tendencies. 2) By somatometry, the region from the scapula to the axilla point the upper back with presents the greatest expansion (more than 30%). The region from scapla to arm presents the maximum rate of contraction. In considering the longitude , under the axilla waist length and the bust point waist length generally shows the greatest rate of expansion. 3) The bust point waist length and under the axilla waist length are of great importance to the basic pattern of clothing. and have expansive tendencies(6.3cm). Among the latitudes, the upper back width has the greatest tendency for expansion (7.83 cm). 4) The region which presents the greatest rate of the expansion and contraction is in the proximity of the arm. These results testify that the amount of room of the back width must be given consideration in constructing the basic pattern of clothing.pattern of clothing.

  • PDF

The Effect of a Task-oriented Upper Arm Exercise on Stable and Unstable Surfaces on Dynamic Balance and Hand Function in Patient with Cerebral Palsy

  • Han, Yong-Gu;Yun, Chang-Kyo
    • The Journal of Korean Physical Therapy
    • /
    • 제29권2호
    • /
    • pp.55-61
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of a task-oriented upper arm exercise performed in a sitting position on either an unstable support surface or a stable support surface for children with cerebral palsy. Methods: We prospectively evaluated 18 children with cerebral palsy. Eight subjects were randomly assigned to each of the stable and unstable support surface groups. We performed the upper arm exercise three times a week for 6 weeks. To confirm the effects of the intervention, the berg balance scale test, modified functional reaching test (MFRT), timed up and go test (TUG), and Jebsen-Taylor hand function test were conducted before and after the study. Results: Significant differences were observed in MFRT and TUG between the experimental and control groups (p<0.05). In the Jebsen-Taylor hand function test, there were significant differences between the groups for the items picking up small objects, stacking checkers, lifting large light objects, and lifting large heavy objects (p<0.05), but not for writing and stimulation of feeding. Significant differences were observed between the groups in items of card turning, lifting large light objects, and lifting heavy objects. Conclusion: The purpose of this study was to evaluate the effectiveness of a task-oriented upper extremity exercise program for dynamic balance and hand function performed in a sitting position with either stable or unstable support by cerebral palsy patients. There were improvements in the two groups, but performing the exercise while sitting on an unstable support surface had a greater effect on dynamic balance and hand function than exercise while sitting on a stable supporting surface. The results of this study can be used to improve the daily lives of cerebral palsy patients.

A Study on the Body Characteristics of Korean Obese Women (Part II)

  • Yi, Kyong-Hwa
    • 한국의류학회지
    • /
    • 제34권6호
    • /
    • pp.982-996
    • /
    • 2010
  • This study classified the body shapes of Korean obese women and investigated the differences of each body shape, using 2004 Size Korea data. For selecting the obesity sample, 7 obesity judgment indices were chosen through previous clothing-related studies. A total of 636 females defined as "obese" by 5 out of 7 indices were selected as subjects and 54 body measurements and obesity judgment indices were used in this study. Firstly, mean, standard deviation, minimum, and maximum values of each measurement and item were obtained from the descriptive analysis of 53 measurements. According to the descriptive analysis, all measurements and obesity judgment indices of the subjects demonstrated a serious obesity level shown by BMI 27.11, R$\ddot{o}$hrer index 1.76, Vervaeck index 104.77, Relative weight 133.00, WHR 0.90, and waist circumference 86.71cm. In addition, the measurements and indices showed considerable differences between minimum and maximum values. Significant differences were identified in all measurements and items at a significant level, p=.001. Each distribution of body types according to age, stature, bust, and waist circumference groups was provided in this study. Secondly, factor analyses were conducted using 38 measurement items to extract the body characteristics of obese women. Factor 1 was "circumference measurements & obesity judgment indices," Factor 2 was "heights & arm-related lengths," and Factor 3 was "size and ratio of waist circumference & hip circumference." Factor 4 was "lengths in upper body," Factor 5 was "back width in upper body," Factor 6 was "side neck point to bust & bust circumference," Factor 7 was "length in lower body & arm circumferences" and Factor 8 was "neck base circumference & front width in upper body." These 8 factors explained 76.54% of the total variance. Finally, 5 body types were selected in the cluster analysis. Type 1 (with big back widths & arm circumferences) was 15.5% of the entire subjects, Type 2 (the shortest and fattest, with big upper body) was 18.8%, Type 3 (with big breast) was 27.8%, Type 4 (the tallest and longest in arm lengths, with the smallest arm circumferences and lengths in torso) was 22.5%, and Type 5 (with big hips compared to waist circumferences, smaller height and upper body) was 15.5%. Fundamental differences were identified in all measurements and items at the significant level of p=.001. In addition, each distribution of body type according to age, height, bust, and waist circumference groups was provided in this study.

상지 근골격계 기능장애 평가 도구 DASH의 고찰 (Disability Measurement Tool for Upper Extremity Disorders: The DASH (Disabilities of the Arm, Shoulder, and Hand))

  • 김규상
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.156-169
    • /
    • 2009
  • In this study, the authors introduced DASH (Disabilities of the arm, shoulder, and hand), which had been developed for evaluating the functional impairment in the movement of upper extremities in regular daily activities, work ability and sports/performing arts ability. It is an ergonomic risk assessment tool used for industrial workers and also a disability measurement tool for upper extremity disorders arising from musculoskeletal disorders and symptom. This study intended to examine the applicability of DASH in occupational health field. Firstly, DASH development process and composition were reviewed through The DASH outcome measure user's manual and early articles. Secondly, reliability, validity, and responsiveness of the DASH in various languages at the application stage as well as its reliability and validity at the early stage of development were investigated. Thirdly, focusing on the application of DASH to clinical cases, workers with musculoskeletal symptoms, healthy workers, workers with other diseases, and general population were discussed besides workers with major musculoskeletal disorders. Lastly, DASH questionnaire was examined for its potential as a reference for assessing the functional impairment in the movement of upper extremities of workers with musculoskeletal symptoms in industrial workers in Korea.

Replica법을 이용한 성인 여성 유방 형태 분석에 관한 연구 (A Study on Analysis of Breast Shapes by Replica Experiments)

  • 이경화
    • 한국의류학회지
    • /
    • 제21권4호
    • /
    • pp.689-698
    • /
    • 1997
  • The purpose of this study is to develop the well-fitted brassieres by observing the changes in the breast sizes and shapes, the surface area and the volume of the breast through the arm movements of 3 types (0$^{\circ}$, 90$^{\circ}$ and 180$^{\circ}$) in vertical motion. The subjects are females, who are aged twenties and wearing a brassiere size 70B, In particular, to obtain the measures regarding the surface area and the volume of the breast, replicas are made at each motion. The results of this study are as follows: 1. The changes in the breast sizes and shapes at each motion By increasing the motions of the arm movement, the following measure items are inclined to decrease: Shoulder length, Side neck point~B.P., Front neck point~B.P., Horizontal length of the cup, Upper bust circumference, Bust circumference, Upper bust depth, Bust depth, Under bust depth, Nipple to tipple breadth, Horizontal distance of bust, Bust height, Cup size. By increasing the motions of the arm movement, the following measure items are inclined to increase: Center point of shoulder~B.P., Shoulder point~B.P., Armpit~ lowest point of breast drooping, Upper bust point~B.P., B.P~Under bust point, Under bust line, Width of gap between breast, Vertical distance of Bust. 2. The changes in the surface area and volume of breast at each motion By making the replica to observe changes in the surface area, which are sectioned to 4 parts(area 1 to area 4) , and volume of breast at each motion, the results are as follows: At 0$^{\circ}$ and 90$^{\circ}$, the sizes of each part are ordered as the following: area2> areal> area4> area3. At 180$^{\circ}$, the sizes of each part are ordered as the following: areal> area2> area4> area3. Through these orders, it is found that the upper and inside part of the breast has the inclination to increase so long as the motions of the arm movement increase. Also, the total surface area increases so long as the motions of the arm movement increase. The volume of the breast increase when the surface area of the breast increases. As a result of the F-test on the changes in the each surface areas, the surface area and volume by arm movements, the significant differences among the each surface areas and the surface area are not found.

  • PDF

Wearable Robot Arm의 제작 및 제어 (Design and Control of a Wearable Robot)

  • 정연구;김윤경;김경환;박종오
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.277-282
    • /
    • 2001
  • As human-friendly robot techniques improve, the concept of the wearability of robotic arms becomes important. A master arm that detects human arm motion and provides virtual forces to the operator is an embodied concept of a wearable robotic arm. In this study, we design a 7 DOF wearable robotic arm with high joint torques. An operator wearing this robotic arm can move around freely because this robotic arm was designed to have its fixed point at the shoulder part of the operator. The proposed robotic arm uses parallel mechanisms at the shoulder part and the wrist part on the model of the human muscular structure of an upper limb. To reduce the computational load in solving the forward kinematics and to prevent singularity motions of the parallel mechanism, yawing motion of the parallel mechanisms was separated using a slip ling mechanism. The total weight of the proposed robotic arm is about 4 kg. An experimental result of force tracking test for the pneumatic control system and an application example for VR robot are described to show the validity of the robot.

  • PDF