• Title/Summary/Keyword: Uplift

Search Result 463, Processing Time 0.028 seconds

Determination of Uplift Capacity of Pile in Sand (모래 지반에 위치한 말뚝의 인발 저항력)

  • Lee, Young Hoon;Kwon, Oh Kyun;Kim, Myoung Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.229-235
    • /
    • 1993
  • This paper examines the conventional methods to estimate the uplift capacity of the piles in sands and points out the limitations of each methods. And the modified method to estimate the uplift capacity more correctly is proposed. The comparisons between each theoretical values and the reported experimental results show that Meyerhof method tends to underestimate the uplift capacity for dense sands, but to overestimate for medium and loose sands. Of the analytical methods, Chattopadhyay and Pise method is most agreeable to the experimental data. But the difference between the measured values and the analytical ones is significant. This difference can be reduced by the modification of the failure surface proposed by Chattopadyay and Pise.

  • PDF

Seismic response analysis of an unanchored vertical vaulted-type tank

  • Zhang, Rulin;Cheng, Xudong;Guan, Youhai;Tarasenko, Alexander A.
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • Oil storage tanks are vital life-line structures, suffered significant damages during past earthquakes. In this study, a numerical model for an unanchored vertical vaulted-type tank was established by ANSYS software, including the tank-liquid coupling, nonlinear uplift and slip effect between the tank bottom and foundation. Four actual earthquakes recorded at different soil sites were selected as input to study the dynamic characteristics of the tank by nonlinear time-history dynamic analysis, including the elephant-foot buckling, the liquid sloshing, the uplift and slip at the bottom. The results demonstrate that, obvious elephant-foot deformation and buckling failure occurred near the bottom of the tank wall under the seismic input of Class-I and Class-IV sites. The local buckling failure appeared at the location close to the elephant-foot because the axial compressive stress exceeded the allowable critical stress. Under the seismic input of Class-IV site, significant nonlinear uplift and slip occurred at the tank bottom. Large amplitude vertical sloshing with a long period occurred on the free surface of the liquid under the seismic wave record at Class-III site. The seismic properties of the storage tank were affected by site class and should be considered in the seismic design of large tanks. Effective measures should be taken to reduce the seismic response of storage tanks, and ensure the safety of tanks.

Characteristics of Stress-Displacement on Uplift Loaded Group Piles (인발력을 받는 무리말뚝의 응력-변위 특성)

  • Lee, Jun-Dae;Ahn, Byeong-Cheol
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.152-157
    • /
    • 2005
  • This experimental study was devoted to investigate skin friction of H group piles with uplift loading conditions in granite soil under laboratory test. Model piles made of steel embedded in weathered granite soil were used in this study. Pile arrangements($2{\times}2,\;3{\times}3$), pile space(2D, 4D, 6D), and soil density($D_r=40%,\;80%$) were tested. The main results obtained from the model tests can be summarized as follows. The series of tests found that ultimate uplift load and displacement for group piles were increased as piles space ratio increases to $D_r=40%$ of soil density. In the relative density of $D_r=80%$, bearing capacity for group piles was greater than for single pile. In the relative density of $D_r=40%$, the theoretical value of skin friction for group piles was greater than practical value. In the relative density of $D_r=80%$, both theoretical and practical value of skin friction for group piles were increased as piles space ratio increases.

Numerical analysis of an innovative expanding pile under static and dynamic loading

  • Abdullah Cheraghi;Amir K. Ghorbani-Tanha
    • Geomechanics and Engineering
    • /
    • v.32 no.4
    • /
    • pp.453-462
    • /
    • 2023
  • Designing pile foundations subjected to the uplift forces such as buildings, oil platforms, and anchors is becoming increasingly concerned. In this paper, the conceptual design of a new type of driven piles called expanding pile is presented and assessed. Some grooves have been created in the shaft of the novel pile, and some moveable arms have been designed at the pile tip. At first, static analyses using the finite element method were performed to evaluate the effectiveness of the innovative pile on the axial bearing capacity. Then its effect on seismic behavior of moment frame is considered. Results show that the expanding arms were provided an ideal anchorage system because of the soil's noticeable locking-up effect increasing uplift bearing capacity. For example at the end of the static tensile loading procedure, displacement decrement up to 55 percent is observed. In addition, comparing the uplift bearing capacity of the usual and new pile with different lengths in sand and clay layers shows noticeable effect and sharp increase up to about two times especially in longer piles. Besides, a sensible reduction in the seismic response and the stresses in the beam-column connection between 23-36 percent are achieved that ensures better seismic behavior of the structures.

Uplift Rate in the Eastern Block of the Ulsan Fault (울산단층 동부 지괴의 융기율)

  • Lee, Gwang-Ryul;Park, Chung-Sun
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.4
    • /
    • pp.29-39
    • /
    • 2020
  • This study estimated influences of the Ulsan Fault on tectonic movement and uplift characteristics in the Eastern Block of the Ulsan Fault. The averaged uplift rate in the Northern Coast of the Eastern Block was 0.202 m/ka, while the site in Seokbyeong-ri, Guryongpo-eup, Pohang-si, showed relatively high rate of 0.249 m/ka, attributable to influences of small fault movement, called the Gangsa Fault. Higher averaged rate of 0.270 m/ka than in the Northern Coast was calculated in the Southern Coast of the Eastern Block. The site in north of Haseo-ri, Yangnam-myeon, Gyeongju-si, showed the highest rate, suggesting influences of the Eupcheon Fault. The Western Block of the Ulsan Fault indicated the averaged rate of 0.208 m/ka, similar to that of the Northern Coast. The sites approximately 10 km apart from the Ulsan Fault showed 1.3 times higher rate in the Eastern Block than in the Western Block, while similar rates were calculated in the sites >20 km apart from the Ulsan Fault. These distributions of the rate suggest that the Ulsan Fault has significantly influenced development of marine terrace and tectonic movement in the study area, while local fault movements have also played a role.

Fluvial Terrace and Incision Rate in the Middle Sobaek Mountain Range (소백산맥 중부 지역의 하안단구와 하각률)

  • Lee, Gwang-Ryul;Park, Chung-Sun
    • Journal of The Geomorphological Association of Korea
    • /
    • v.28 no.2
    • /
    • pp.15-30
    • /
    • 2021
  • This study tried to reveal distribution of incision rate and the factors from fluvial terrace deposits on the western and eastern slopes in the Middle Sobaek Mountain Range, using OSL age dating and topographical analysis. An average incision rate of 0.220 m/ka was estimated in the western slope streams, while the streams on the eastern slope showed a lower average incision rate of 0.121 m/ka. These results seem to indicate that the study area experienced an asymmetric uplift. Patterns of incision rate in the study area were different from those in the Northern Sobaek Mountain Range, probably suggesting that the Sobaek Mountain Range experienced spatially different uplift patterns. Among the factors, which were considered to influence on distribution of incision rate in the study area (e.g., altitude of sampling point, distance from divide, distance from axis, channel width, and bedrock type), distance from axis showed the strongest relationship with incision rate. Therefore, uplift is thought to be the most significant factor in distribution of incision rate in the Middle Sobaek Mountain Range.

Modeling the Effect of Geology on Uplift in Concrete Gravity Dam Foundations with the Discontinuous Deformation Analysis (불연속 변형 해석을 통한 콘크리트 중력댐 기초에 작용하는 부양력에 대한 지질구조의 영향 모델링)

  • Kim, Yong-Il
    • Tunnel and Underground Space
    • /
    • v.13 no.4
    • /
    • pp.304-315
    • /
    • 2003
  • In this paper, the DDA method with a new hydro-mechanical algorithm is used to study the effect of rock discontinuities on uplift and seepage in concrete gravity dam foundations. This paper presents an alternative method of predicting uplift and seepage at the base of concrete gravity dams. A sensitivity analysis was carried out to study the importance of several parameters on dam stability such as the orientation, spacing, and location of discontinuities. The study shows that joint water flow and adverse geological conditions could result in unusual uplift at the base of concrete gravity dams, well in excess of what is predicted with the classical linear or hi-linear pressure assumption. It is shown that, in general, the DDA program with the hydro-mechanical algorithm can be used as a practical tool in the design of gravity dams built on fractured rock masses.

Experimental study on the method of estimating the vertical design wave force acting on a submerged dual horizontal plate

  • Kweon, Hyuck-Min;Oh, Sang-Ho;Choi, Young-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.4
    • /
    • pp.569-579
    • /
    • 2013
  • A steel-type breakwater that uses a submerged dual horizontal porous plate was originally proposed by Kweon et al. (2005), and its hydrodynamic characteristics and design methodology were investigated in a series of subsequent researches. In particular, Kweon et al. (2011) proposed a method of estimating the vertical uplift force that acts on the horizontal plate, applicable to the design of the pile uplift drag force. However, the difference between the method proposed by Kweon et al. (2011), and the wave force measured at a different time without a phase difference, have not yet been clearly analyzed. In this study, such difference according to the method of estimating the wave force was analyzed, by measuring the wave pressure acting on a breakwater model. The hydraulic model test was conducted in a two-dimensional wave flume of 60.0 m length, 1.5 m height and 1.0 m width. The steepness range of the selected waves is 0.01~0.03, with regular and random signals. 20 pressure gauges were used for the measurement. The analysis results showed that the wave force estimate in the method of Kweon et al. (2011) was smaller than the wave force calculated from the maximum pressure at individual points, under a random wave action. Meanwhile, the method of Goda (1974) that was applied to the horizontal plate produced a smaller wave force, than the method of Kweon et al. (2011). The method of Kweon (2011) was already verified in the real sea test of Kweon et al. (2012), where the safety factor of the pile uplift force was found to be greater than 2.0. Based on these results, it was concluded that the method of estimating the wave force by Kweon et al. (2011) can be satisfactorily used for estimating the uplift force of a pile.

Thermal and uplift histories of Mesozoic granites in Southeast Korea: new fission track evidences

  • Shin, Seong-Cheon;Susumu Nishimura
    • The Journal of the Petrological Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.104-121
    • /
    • 1993
  • Fission track (FT) thermochronological analyses on Mesozoic granites provide new information about cooling and uplift histories in Southeast Korea. Twenty-nine new FT sphene, zircon and apatite ages and seven track length measurements are presented for eleven granite samples. Measured mineral ages against assumed closure temperatures yield cooling rates for each sample. Relatively rapid (7-$15^{\circ}C$/Ma) and simple cooling patterns from the middle Cretaceouss (ca. 90-100 Ma) granites are caused mainly by a high thermal contrast between the intruding magma and country rocks at shallow crustal levels (ca. 1-2.5 km-depths). On the contrary, a slow overall cooling (1-$4^{\circ}C$/Ma) of the Triassic to Jurassic granites (ca. 250-200 Ma), emplaced at deep depths (>>9 km), may mainly depend upon very slow denudation of the overlying crust. The uplift history of the Triassic Yeongdeog Pluton in the Yeongyang Subbasin, west of the Yangsan Fault, is characterized by a relatively rapid uplift (~0.4 mm/a) before the total unroofing of the pluton in the earliest Cretaceous (~140 Ma) followed by a subsidence (~0.2mm/a) during the Hayang Group sedimentation. Stability of original FT zircon ages (156 Ma) and complete erasure of apatite ages suggest a range of 3 to 5.5 km for the basin subsidence. Since 120 Ma up to present, the Yeongyang Subbasin has been slowly uplifted (~0.04 mm/a). The FT age patterns of Jurassic granites both from the northeastern wing of the Ryeongnam Massif and from the northern edge of the Pohang-Kampo Block indicate that the two geologic units have been slowly uplifted with a same mean rate (~0.04 mm/a) since early Cretaceous. Estimates of Cenozoic total uplifts since 100 Ma are different: Ryeongnam Massif (~6 km)=Pohang-Kampo Block (~6 km)>Yeongyang Subbasin(~4 km).

  • PDF

Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions (기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성)

  • Song, ChangSeob;Jang, UngHee;Choi, DookHo;Kim, JungChul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.