• Title/Summary/Keyword: University of Cambridge

Search Result 218, Processing Time 0.031 seconds

Analysis of Contents related to Models in the Chemistry Textbooks of the 2009 & 2015 Revised Curricula: Focusing on the Electrolysis of Aqueous Solutions (2009 및 2015 개정 교육과정의 화학 교과서에서 모델 관련 내용 분석: 수용액 전기 분해를 중심으로)

  • Kim, Kihyang;Chang, Hasok;Paik, Seoung-Hey
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.4
    • /
    • pp.289-306
    • /
    • 2019
  • The purpose of this study is to compare the contents of chemistry textbooks developed according to the 2015 revised curriculum with the contents of the 2009 revised curriculum to research the change in "the development and use of models". To do this, we analyzed 8 kinds of Chemistry I textbooks and 6 kinds of Chemistry II textbooks from the 2015 revised curriculum and compared them with 4 kinds of Chemistry I textbooks and 4 kinds of Chemistry II textbooks from the 2009 revised curriculum. The scope of the analysis was the explanations of the textbooks related to aqueous electrolysis experiments. In order to compare the contents regarding electrolytes when the same experiments are interpreted with different models, we analyzed contents of 4 kinds of middle school science textbooks from the 2015 revised curriculum and 9 kinds of middle school science textbooks from the 2009 revised curriculum. As a result of the analysis, the same experiment was explained by different models according to the grade level and unit, and all explanations were limited to a single model. Also, the tendency to limit the kinds of electrolytes for controlled experimental results is more pronounced in the 2015 revised curriculum than in the 2009 revised curriculum. From this results, we suggest that efforts are needed to reflect the "development and use of models" in chemistry textbooks developed according to the 2015 revised curriculum.

Annual Occurrence Patterns and Three Dimensional Distribution of Mushroom Flies in Pleurotus ostreatus Cultivation Farms (느타리버섯 재배에서 버섯파리의 연중발생패턴과 입체적 분포)

  • Kang, Min-Gu;Kim, Seung-Han;Choi, Chee-Wan;Disney, Henry L;Kwon, Oh-Seok
    • Korean journal of applied entomology
    • /
    • v.56 no.2
    • /
    • pp.213-222
    • /
    • 2017
  • Among flies inside mushroom growing rooms in three farms, Lycoriella ingenua and Megaselia tamilnaduensis were the most common and dominant species during Pleurotus ostreatus cultivation in Korea. In the past, generally, during the incubation period, a low density of mushroom flies was observed in all farms. After the first harvest, mushroom flies density tended to increase sharply. However, many mushroom flies were observed in the summer, despite that season corresponds to the incubation period. This is because annual cultivation systems provide a safe overwintering place compared to seasonal selective ones. The ecology of mushroom flies varies greatly according to the cultivation system. We confirmed that a fallow period reduced the density of mushroom flies. From a survey of the three dimensional distribution of mushroom flies in a growing room, we observed that M. tamilnaduensis showed more positive phototaxis and a higher variation per point of capture than that by L. ingenua. Through this study, two mushroom fly species were identified in the survey farms, with markedly different three dimensional distribution patterns.

Nutritional Regulation of GLUT Expression, Glucose Metabolism, and Intramuscular Fat Content in Porcine Muscle

  • Katsumata, M.;Kaji, Y.;Takada, R.;Dauncey, M.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.8
    • /
    • pp.1297-1304
    • /
    • 2007
  • We conducted a series of investigations in order to elucidate role of nutritional status in regulating GLUT expression and energy metabolism in porcine muscle. Firstly, the role of mild undernutrition in regulating muscle GLUT gene expression and function was studied in growing pigs (3 wk of age) on a high (H) or low (L) food intake (H = 2L) at $35^{\circ}C$ or $26^{\circ}C$. Low food intake selectively upregulates GLUT1 and GLUT4 gene expression; mRNA levels were elevated in longissimus dorsi (L. dorsi) and rhomboideus muscles but not in diaphragm or cardiac muscles. Our next step was to determine whether dietary lysine, a major primary limiting amino acid in diets for pigs, affects muscle GLUT4 expression. Pigs of 6 wk of age were pair-fed a control or low lysine (LL) diet. The control diet contained optimal amounts of all essential amino acids, including 1.15% lysine. The LL diet was similar but contained only 0.70% lysine. GLUT4 mRNA expression was upregulated by the LL diet in L. dorsi and rhomboideus muscles, whereas that in cardiac muscle was unaffected. GLUT4 protein abundance was also higher in rhomboideus muscle of animals on the LL diet. We conducted another investigation in order to elucidate effects of the LL diet on post-GLUT4 glucose metabolism. Activity of hexokinase was unaffected by dietary lysine levels while that of citrate synthase was higher both in L. dorsi and rhomboideus muscles of pigs fed on the LL diet. Glucose 6-phosphate content was higher in L. dorsi msucle in the LL group. Glycogen content was higher both in L. dorsi and rhomboideus muscles in the LL group. Further, we determined the effects of dietary lysine levels on accumulation of intramuscular fat (IMF) in L. dorsi muscle of finishing pigs. A low lysine diet (lysine content was 0.40%) meeting approximately 70% of the requirement of lysine was given to finishing pigs for two months. IMF contents in L. dorsi of the pigs given the low lysine diet were twice higher than those of the pigs fed on a control diet (lysine content was 0.65%). Finally, we proved that a well known effect of breadcrumbs feeding to enhance IMF of finishing pigs could be attributed to shortage of amino acids in diets including breadcrumbs.

A Study on the Effectiveness of the Exclusion Calculation for the Product Inclusive Design: A Case Study on the Evaluation of Electric Iron (제품의 포용적 디자인을 위한 Exclusion Calculation 평가 방법의 효용성 연구: 전기다리미 평가를 사례 연구로)

  • Zhang, Ji-Fa;Go, Jung-Wook
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.4
    • /
    • pp.111-123
    • /
    • 2020
  • It is very important to ensure usability and inclusion in product design and development. Exclusion Calculation, developed by Simon Keates and P. John Clarkson at Cambridge University's Engineering Design Center, assesses the usability and inclusiveness of the product. In context of inadequate research on effectiveness of Exclusion Calculation, this study carried out the experimental evaluation of electric iron and discussed the effectiveness of the Exclusion Calculation from usefulness, accuracy of its evaluation results and the intuitiveness of the evaluation items. 11 designers used Exclusion Calculation in product evaluation and estimated the intuitiveness of 14 evaluation items in Exclusion Calculation by questionnaire. Then usefulness of the evaluation results was discussed and the accuracy of the evaluation results was analyzed by standard deviation. From the evaluation results, the research found that Exclusion Calculation could help designers identify the usability problems and the generality of usability problems related to the physical characteristics of the products, but it can not find the problems from logical aspect of using. In addition, the ambiguity of the evaluation scale in Exclusion Calculation leads to lower accuracy of the evaluation results. Most of evaluation items in Exclusion Calculation were easy to be identified and judged, while evaluation items related to cognitive abilities are less intuitive.

THE MEDIAL SIGMOID DEPRESSION: Its Anatomic and Radiographic Considerations (하악골과 방사선사진상에서의 하악절흔 내측 함요)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 1991
  • An anatomic radiolucency called medial sigmoid depression can be observed on a number of panoramic and mandibular oblique lateral views in the ramus just below and anterior to the mandibular sigmoid notch. The radiolucency may be unilateral or bilateral. Seventy-eight mandibles of dry skulls were visually examined and radiographed by panoramic machine. The observable incidence, the location center, and the mean size of the medial sigmoid depression were studied. Additionally, the radiographic incidence of the depression was determined using 500 panoramic radiographs. Normal anatomic radiolucent areas in the jaws are encountered often in the radiographs taken for the usual dental practice purpose. Some of these radiolucencies can be misdiagnosed as pathologic entities. But in most cases, the size, location, and appearance of the radiolucent area, and the presence or absence of symptoms can lead one to the correct diagnosis before surgery is undertaken. And this can be secured if diagnosticians are aware of the common and varied appearances of the normal anatomic radiolucencies A depression in the ramus just below and slightly anterior to the most inferior aspect of mandibular sigmoid notch shows occasionally foramen-like or notch-like radiolucency on some panoramic and oblique lateral views. This radiolucency was named medial sigmoid depression by Langlais et a1. in 1983. Since there're no reports about this medial sigmoid depression after that, (The author retrieved the Mediline from 1983 to 1990: Cambridge scientific abstracts, (7200 Wisconsin Ave Bethesda MD 20814 U.S.A.) National Library of Medicine) the author studied the size and the location of the depression of the mandible specimens, and determined the relationship between the observable anatomic incidence and its reproducibility on the radiographs.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

Effect of Pulsatile Versus Nonpulsatile Blood Flow on Renal Tissue Perfusion in Extracorporeal Circulation (체외순환에서 박동 혈류와 비박동 혈류가 신장의 조직관류에 미치는 영향)

  • Kim Hyun Koo;Son Ho Sung;Fang Yang Hu;Park Sung Young;Kim Kwang Taik;Kim Hark Jei;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.13-22
    • /
    • 2005
  • It has been known that pulsatile flow is physiologic and more favorable to tissue perfusion than nonpulsatile flow. The purpose of this study is to directly compare the effect of pulsatile versus nonpulsatile blood flow to renal tissue perfusion in extracorporeal circulation by using a tissue perfusion measurement system. Material and Method: Total cardiopulmonary bypass circuit was constructed to twelve Yorkshire swines, weighing 20$\~ $30 kg. Animals were randomly assigned to group 1 (n=6, non pulsatile centrifugal pump) or group 2 (n=6, pulsatile T-PLS pump). A probe of the tissue perfusion measurement system $(QFlow^{TM}-500)$ was inserted into the renal pa­renchymal tissue. Extracorporeal circulation was maintained for an hour at a pump flow of 2 L/min after aortic cross-clamping. Tissue perfusion flow of the kidney was measured at baseline (before bypass) and every 10 minutes after bypass. Serologic parameters were collected at baseline and 60 minutes after bypass. Result: Baseline parameters were not different between the groups. Renal tissue perfusion flow was substantially higher in the pulsatile group throughout the bypass (ranged 48.5$\~$ 64 in group 1 vs. 65.8$\~$88.3 mL/min/100 g in group 2, p=0.026$\~$ 0.45) The difference was significant at 30 minutes bypass $(47.5{\pm}18.3\;in\;group\;1\;vs.\;83.4{\pm}28.5$ mL/min/100 g in group 2, p=0.026). Serologic parameters including plasma free hemoglobin, blood urea nitrogen, and creatinine showed no differences between the groups at 60 minutes after bypass (p=NS). Conclusion: Pulsatile flow is more beneficial to tissue perfusion of the kidney in short-term extracorporeal circulation. Further study is suggested to observe the effects to other vital organs or long-term significance.

Effects of different sizes of Hydroxyapatite/$\beta$-Tricalcium phosphate particles on vertical bone augmentation (수직골 증대술에서 $\beta$-Tricalciumphosphate/Hydroxyapatite 골 이식재 입자 크기의 영향)

  • Huh, Jung-Bo;Jung, Dong-Hee;Kim, Ji-Sun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.259-265
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of different sizes of $\beta$-TCP/ HA particles on vertical bone augmentation using titanium mesh in the cranium of rabbits. Materials and methods: Six white rabbits weighing 5kg were used. Four circular grooves of 6mm diameter were made by trephine, and five small holes were drilled in the inner surface of each circular gooves. Different sizes of grafts (small 0.3 - 0.5 mm, medium 0.5 - 1.0, large 1.0 - 2.0 mm) were placed respectively in the experimental groups. Titanium mesh (height 3 mm, width 6 mm) was placed. After 8weeks healing period, the rabbits were euthanized, and the specimens were prepared for histological findings. New bone formation and remaining graft area were measured to calculate the ratio of areas occupying the inner space of titanium mesh. Mann-Whitney U-test and Wilcoxon signed rank-test were used for statistical analysis ($\alpha$ = .05). Results: The experimental groups with $\beta$-TCP/HA graft showed a significantly higher new bone formation (P = .003). Comparing different sizes of $\beta$-TCP/HA, there was no statistical difference in terms of new bone formation. The vertical bone formation (i.e. new bone and graft area) was significantly greater in $\beta$-TCP/HA groups (P = .001). In comparison between different sizes of $\beta$-TCP/HA, medium size group had significantly greater area than large particle size group (P = .039). Conclusion: The use of $\beta$-TCP/HA with titanium mesh showed a higher vertical bone formation, particularly the medium sized $\beta$-TCP/HA particles (0.5 - 1.0 mm) produced better results in vertical bone augmentation.