• Title/Summary/Keyword: Unit-to-unit

Search Result 25,897, Processing Time 0.047 seconds

Overcoming taxonomic challenges in DNA barcoding for improvement of identification and preservation of clariid catfish species

  • Piangjai Chalermwong;Thitipong Panthum;Pish Wattanadilokcahtkun;Nattakan Ariyaraphong;Thanyapat Thong;Phanitada Srikampa;Worapong Singchat;Syed Farhan Ahmad;Kantika Noito;Ryan Rasoarahona;Artem Lisachov;Hina Ali;Ekaphan Kraichak;Narongrit Muangmai;Satid Chatchaiphan6;Kednapat Sriphairoj;Sittichai Hatachote;Aingorn Chaiyes;Chatchawan Jantasuriyarat;Visarut Chailertlit;Warong Suksavate;Jumaporn Sonongbua;Witsanu Srimai;Sunchai Payungporn;Kyudong Han;Agostinho Antunes;Prapansak Srisapoome;Akihiko Koga;Prateep Duengkae;Yoichi Matsuda;Uthairat Na-Nakorn;Kornsorn Srikulnath
    • Genomics & Informatics
    • /
    • v.21 no.3
    • /
    • pp.39.1-39.15
    • /
    • 2023
  • DNA barcoding without assessing reliability and validity causes taxonomic errors of species identification, which is responsible for disruptions of their conservation and aquaculture industry. Although DNA barcoding facilitates molecular identification and phylogenetic analysis of species, its availability in clariid catfish lineage remains uncertain. In this study, DNA barcoding was developed and validated for clariid catfish. 2,970 barcode sequences from mitochondrial cytochrome c oxidase I (COI) and cytochrome b (Cytb) genes and D-loop sequences were analyzed for 37 clariid catfish species. The highest intraspecific nearest neighbor distances were 85.47%, 98.03%, and 89.10% for COI, Cytb, and D-loop sequences, respectively. This suggests that the Cytb gene is the most appropriate for identifying clariid catfish and can serve as a standard region for DNA barcoding. A positive barcoding gap between interspecific and intraspecific sequence divergence was observed in the Cytb dataset but not in the COI and D-loop datasets. Intraspecific variation was typically less than 4.4%, whereas interspecific variation was generally more than 66.9%. However, a species complex was detected in walking catfish and significant intraspecific sequence divergence was observed in North African catfish. These findings suggest the need to focus on developing a DNA barcoding system for classifying clariid catfish properly and to validate its efficacy for a wider range of clariid catfish. With an enriched database of multiple sequences from a target species and its genus, species identification can be more accurate and biodiversity assessment of the species can be facilitated.

Development of the Air-Conditioning Unit for Workspace Integrated Units (사무공간의 통합유니트 구축을 위한 공조유니트 도출에 관한 연구)

  • Kim Ji-Hyun;Kim Sun-Sook;Yang In-Ho;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.669-680
    • /
    • 2005
  • The purpose of this study is to develop the air-conditioning unit combined with the lighting unit for workspace and to supply its performance data at architectural design stage. The air-conditioning unit is one of the components of a workspace integrated unit, which can be defined as the planning unit satisfying the environmental comfort criteria of workspace. Air-conditioning diffusers are classified according to throws and features by literature review and case study. Then diffusers are combined with the lighting unit. Through the CFD simulation, the thermal performance of each unit was evaluated and finally various air-conditioning units combined with the lighting units were developed.

Multi-unit Level 2 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Cho, Jaehyun;Han, Sang Hoon;Kim, Dong-San;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1234-1245
    • /
    • 2018
  • The risk of multi-unit nuclear power plants (NPPs) at a site has received considerable critical attention recently. However, current probabilistic safety assessment (PSA) procedures and computer code do not support multi-unit PSA because the traditional PSA structure is mostly used for the quantification of single-unit NPP risk. In this study, the main purpose is to develop a multi-unit Level 2 PSA method and apply it to full-power operating six-unit OPR1000. Multi-unit Level 2 PSA method consists of three steps: (1) development of single-unit Level 2 PSA; (2) extracting the mapping data from plant damage state to source term category; and (3) combining multi-unit Level 1 PSA results and mapping fractions. By applying developed multi-unit Level 2 PSA method into six-unit OPR1000, site containment failure probabilities in case of loss of ultimate heat sink, loss of off-site power, tsunami, and seismic event were quantified.

Multi-unit Level 3 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Kim, Sung-yeop;Jung, Yong Hun;Han, Sang Hoon;Han, Seok-Jung;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1246-1254
    • /
    • 2018
  • The importance of performing Level 3 probabilistic safety assessments (PSA) along with a general interest in assessing multi-unit risk has been sharply increasing after the Fukushima Daiichi nuclear power plant (NPP) accident. However, relatively few studies on multi-unit Level 3 PSA have been performed to date, reflecting limited scenarios of multi-unit accidents with higher priority. The major difficulty to carry out a multi-unit Level 3 PSA lies in the exponentially increasing number of multi-unit accident combinations, as different source terms can be released from each NPP unit; indeed, building consequence models for the astronomical number of accident scenarios is simply impractical. In this study, a new approach has been developed that employs the look-up table method to cover every multi-unit accident scenario. Consequence results for each scenario can be found on the table, established with a practical amount of effort, and can be matched to the frequency of the scenario. Preliminary application to a six-unit NPP site was carried out, where it was found that the difference between full-coverage and cut-off cases could be considerably high and therefore influence the total risk. Additional studies should be performed to fine tune the details and overcome the limitations of the approach.

compare the level of job stress, burn-out and job satisfaction between intensive care unit nurses and general unit nurses (중환자실간호사와 병동간호사의 직무스트레스, 소진 및 직무만족도 정도비교)

  • Oh, Eun-Wha;Yang, So-Myoung;Kim, So-Hyun;You, Ha-Na;Chin, Eun-Young;Kim, Yeo-Jin;Kim, Young-hee
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.22 no.1
    • /
    • pp.27-36
    • /
    • 2016
  • Purpose: The purpose of this study was to compare the level of job stress, burn-out and job satisfaction between intensive care unit nurses and general unit nurses. Methods: The subjects of this study were 100 intensive care unit nurses and 100 general unit nurses in university's hospitals. The data were collected using self-report questionnaires. The data were analyzed by descriptive statistics, -test, ANCOVA, t-test, ANOVA, and Pearson correlation coefficient by using the SPSS WIN 20.0 program. Results: There were significantly negative correlation in the score of job stress and job satisfaction in both groups of nurses. Job stress of intensive care unit nurses was significantly differences according to department satisfaction. Burn-out of intensive care unit nurses was significantly differences according to position, department satisfaction. Job satisfaction of intensive care nurses unit was significantly differences according to department satisfaction. Job stress of general unit nurses unit was significantly differences according to department satisfaction. Burn-out of general unit nurses was significantly differences according to clinical experience, position, department satisfaction. Job satisfaction of general unit nurses was significantly differences according to clinical experience, department satisfaction. Conclusions: The appropriate rewards for intensive care nurses and general unit nurses to decrease their job stress will be needed in hospital settings. In addition, a plan for systemic nurse training program is needed to provide high quality nursing education for each unit nurses effectively.

  • PDF

An Analysis of Call Demands of Two Squads In Kyonggi Provincial fire and Disaster Headquarters (경기도 소방재난본부에 소속된 두 구급대의 출동수요 분석)

  • Uhm, Tai-Hwan
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • The purposes of this research which was conducted by surveying lost/added unit hours reports, unit hour demand analysis worksheets from prehospital care reports of two squads in Kyonggi Provincial Fire and Disaster Headquarters for 20 weeks (January 1, 2002 - May 20, 2002) are to get Unit Hour Utilizations. Call Demands such as Unit Hour Demand, Simple Average Demand, High Average Demand, Peak Average Demand, the High Actual Demand. The conclusions from this analysis were summarized as follows: (1) By revealing Unit Hour Produced 3223.9, Call Volume 964, Unit Hour Utilization 0.299 at the Squad A and Unit Hour Produced 3328.4, Call Volume 901, Unit Hour Utilization 0.271 at the Squad B induced Korean Squads to chance identification, definition, direction of Unit Hour Utilization. (2) By revealing Simple Average Demand 7.4 on Monday Tuesday, High Average Demand 9.6 on Tuesday Friday. Peak Average Demand 11.5 on Tuesday, the High Actual Demand 12 on Tuesday Wednesday at the Squad A and Simple Average Demand 6.8 on Sunday, High Average Demand 10.4 on Monday, Peak Average Demand 11.5 on Monday, the High Actual Demand 13 on Monday at the Squad B enabled Korean Squads to utilize System Status Management. (3) The Maximum Calls per Unit Hour were 115 for 23:00~23:59, the Minimum Calls per Unit Hour were 46 for 05:00~05:49 in two squads. The Maximum Calls per Unit Hour were 7.4 on Tuesday Saturday, the Minimum Calls per Unit Hour were 6.1 on Thursday at the Squad A. The Maximum Calls per Unit Hour were 7.3 on Monday Saturday, the Minimum Calls per Unit Hour were 5.6 on Thursday at the Squad B. (4) Analyzing demand for EMTs in the optimum emergency medical service of Korea, we have been able to utilize this Unit Hour Utilization in company with the established estimation methods such as international comparisons or the number of ambulances for scientific reasonable estimation. (5) These Call Demands which were limited to the demand time in this study will make us expect some following studies including demand time, demand time, demand map for Strategic Deployment.

  • PDF

Development and Evaluation of Fixation Equipment for Transporting Unit Modules

  • Park, Su-Yeul;Kim, Kyoon-Tai;Park, Nam-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.609-618
    • /
    • 2013
  • The unit modular construction system is a building technique in which unit modules are manufactured at a factory and then assembled at the construction site. It has many benefits, including reduction of the construction period and improvement in quality. For this reason, it is utilized for various purposes in Japan and England. While it has been introduced in Korea, there have been few Korean studies conducted on the unit modular system. In particular, little research has been done on the method of safely fixating the unit modules to a truck. Therefore, this study reviewed the fixation methods of unit modules for transport, analyzed the problems, and designed a fixation device for unit modules. In addition, a device for the fixation of unit modules to a truck was developed, and a structural simulation was implemented for a safety test by considering the maximum stress generated during the transport of the unit modules fixed on a truck. When the device for the fixation of unit modules is manufactured based on the results of the structural simulation done in this study, it is expected to aid the development of a more practical fixation device for unit modules.

Analysis on the Unit-Plans of Shinonome Canal Court Multi-dwellings Project in Japan (일본 공동주택 시노노메 캐널코트의 단위세대 주거평면 분석)

  • Suh, Kuee-Sook
    • Journal of the Korean housing association
    • /
    • v.19 no.2
    • /
    • pp.43-54
    • /
    • 2008
  • The aim of the research is to find out the direction of unit-plans in multi-dwellings for the future society. Shinonome Canal Court where residents actually live now are the objects in this study, and the residential floor plan of unit-plans were analyzed to find out the typical types. The analysis was focused on the unit-plans of 5 blocks of Shinonome Canal Court. Space Syntax Theory was used as the analysis method. As the first stage of the analysis, justified graphs were made to find out the characters of unit-plans through the classification of the graphs. Contents of the analysis are as follows: Relationship between classified justified graphs and dimension according to node number. Relationship between classified justified graph patterns and unit-plans. Characters of unit-plans in each blocks. Shinonome Canal Court consists of mainly small scale unit-plans and 30unit-plans are classified. 1LDK, 2LDK, 1LDK+S, 1LDK+f are typical unit-plans which are mainly supplied in the complex. It is noted that the results of the analysis by node, justified graph pattern and dimension are the same. It also presents diverse unit-plans which shows a change in nLDK pattern or add f (foyer), AN (annex), S (service room), Fs (free space) to basic nLDK type. In summary, it demonstrates the possibility of creating new residental floor plans in multi-dwellings.

A Study on the Design of Upward and Downward Traverse Units in an Automatic Object Changer Unit to Establish a Flexible Production System (Part 1) (유연생산 시스템 구축을 위한 공작물 자동교환 유닛의 상하 이송 기구 설계에 관한 연구(파트 1))

  • Park, Hoo-Myung;Kang, Jin-Kab;Lee, Yong-Joong;Ha, Man-Kyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.2
    • /
    • pp.45-51
    • /
    • 2008
  • The objective of this study is to develop an automatic object changer unit to improve processing problems existed in the conventional horizontal machining center. In order to perform this objective, a upward and downward traverse unit in which a unit that consists of a motor and reducer, chain and sprocket wheel, and upper and lower base employed in an automatic object changer unit performs sliding contact motion in a frame was designed. To achieve this design, constraint conditions for the upward and downward traverse unit first designed. Then, an operation mechanism was designed and that was introduced as a sum of kinetic energy for the sprocket wheel and upper and lower base based on the moment of inertia, which is the kinetic energy of the converted upward and downward traverse unit in the side of the reducer. In addition, The work required to rotate the converted upward and downward traverse unit in the side of the reducer by one revolution can be calculated using the sum of work that is required in the sprocket wheel and upper and lower base that is a part of the upward and downward traverse unit. Furthermore, the converted equation of motion in the side of the motor can be introduced using the equation of motion using the converted upward and downward traverse unit in the side of the motor. Then, Then, a proper motor can be determined using predetermined specifications employed in the motor and several parameters in the upward and downward traverse unit in order to verify such predetermined specifications. Also, a design of a horizontal traverse unit that performs sliding motion on a upward and downward traverse unit and simulation that verifies the results of this design are required as a future study.

  • PDF

Analysis and Design of Low Pass Filter using Unit Cell based on CRLH Transmission Line

  • Yang, Lei;Yang, Doo-Yeong
    • International Journal of Contents
    • /
    • v.8 no.3
    • /
    • pp.100-104
    • /
    • 2012
  • In this paper, a unit cell for low pass filter design by using composite right and left-handed transmission line in conductor-backed coplanar waveguide is proposed. The characteristics of the unit cell are analyzed in order to design a low pass filter in small sizes. By changing the sizes of the unit cell, the parameters of right-handed and left-handed immittance components are changed and the desired characteristics of the unit cell are achieved. The equivalent circuit of the unit cell is extracted and analyzed either. As a result, the simulation results of the unit cell and the equivalent circuit are almost identified. The movement and energy distributions of electromagnetic field are shown to confirm the property of the unit cell. In the end, a low pass filter is demonstrated by cascading three proposed unit cells, which shows cutoff frequency of 1.53GHz and deep attenuation from 2.23GHz to 4.49GHz lower than -50dB.