• Title/Summary/Keyword: Unit module

Search Result 835, Processing Time 0.028 seconds

A New Design Technique of 40 GHz Up-Converter Modules for Digital Microwave Radios

  • Kim, Kang Wook;Woo, Dong-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.295-299
    • /
    • 2004
  • A new design technique of fabricating 40 GHz up-converter modules for digital microwave radios has been developed. The design of the up-converter module is based on unit circuit blocks, which are to be characterized using a special test fixture. The complete module design may be as simple as a cascade layout of these unit circuit blocks. Also, the 40 GHz up-converter module employs a new microstrip-to-waveguide transition and a tapped edge-coupled filter, which are less sensitive to fabrication tolerances.

Design and Implementation of a Power Conversion Module for Solid State Transformers using SiC MOSFET Devices (배전용 반도체 변압기 구현을 위한 SiC MOSFET 기반 전력변환회로 단위모듈 설계에 관한 연구)

  • Lim, Jeong-Woo;Cho, Young-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.109-117
    • /
    • 2017
  • This paper describes the design and implementation of a unit module for a 10 kVA class 13.2 kV/220 V unidirectional solid-state transformer (SST) with silicon-carbide metal-oxide-semiconductor field-effect transistors. The proposed module consists of an active-front-end (AFE) converter to interface 1320 V AC voltage source to 2500 V DC link and an isolated resonant DC-DC converter for 500 V low-voltage DC output. The design approaches of the AFE and the isolated resonant DC-DC converters are addressed. The control structures of the converters are described as well. The experiments for the converters are performed, and results verify that the proposed unit module can be successfully adopted for the entire SST operation.

A Study on Bypass Characteristics for Photovoltaic Module (태양광모듈 바이패스 특성에 관한 연구)

  • Chae, Myoung-Suk;Suh, Hun-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.79-80
    • /
    • 2014
  • In this paper, to make sure that the photovoltaic solar cell module of the system can be normal for output in each solar cell module, input and output unit is installed in the bypass device, and then through the voltage and current monitoring to determine abnormality of the solar cell module, in the case of abnormal occurring, the bypass device can be pass to the next solar module of the serial structure.

  • PDF

The Numerical Simulation of Fluid Flow in an Automotive HVAC module by using Commercial Code (상업용 코드를 이용한 차량용 HVAC module의 유동에 관한 전산모사)

  • KIM H. B.;HONG S. R.;CHUNG D. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.194-199
    • /
    • 2003
  • The studying is to analyze characteristic of air flow and is used to design in an automotive HVAC module. The RNG k-e turbulence model with the Upwind Difference convection scheme and an unstructured hybrid mesh with arbitrary matching method were applied to the simulation. The comparing air flow characteristic of the basic HVAC module and total HVAC module with blower were discussed in the paper.

  • PDF

A New Evaluation Method for the Effectiveness of Standardized Packing Module (포장모듈 표준화 효과의 평가 방법 연구)

  • Choi, Chang-Ho;Kim, Gwang-Ho;Park, Dong-Joo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.562-568
    • /
    • 2008
  • The modern logistics has tried not only to convert the conventional packing system into unit load system using pallet but also to enhance the fitness between packing facilities and transport modes. This is based on the goal to reduce total logistics cost by improving logistics efficiency. Since the packing unit can affect both loading rate and loading facilities, basic form of packing unit is very important to unit load system. The object of this study is to develop a new method for evaluating the effectiveness of standardized packing module. The new method is based on measure of effectiveness (MOE) which are identified by expert survey. This study has originality in that the collecting method for effectiveness of standardized packing module has not been developed up to now.

A Study on the RRMC Implementation for the Efficient Resource Management in DBS System (DBS 시스템에서 효율적인 자원 관리를 위한 RRMC 구현에 관한 연구)

  • Shin, Cheon-Sig;Kim, Shin-Hong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.12
    • /
    • pp.3133-3138
    • /
    • 1997
  • The Digital Broadcasting Satallite System consists of the Transmitter station, the Resource and Subscriber Management System, and the Receiver Test Unit. The RSMS consists or several modules such as Resource Main Module, Resource User Interface Module, Transmitter Station Interface Module, Receiver Test Unit Interface Module, Subscriber sales Outlets Module and Monitor & Control Module. In this paper we suppose the new RRMC Algorithms that is to manage efficiently the Resource and subscriber information in the Direct Broadcasting Satellite system based on client-sever features and demonstrates the implementation method of monitoring and control the system in real time. Also we explain the communication procedure between resource and subscriber managment and other equipment.

  • PDF

A High Performance Asynchronous Interface Unit for Globally-Asynchronous Locally-Synchronous Systems (전역적 비동기 지역적 동기 시스템을 위한 고성능 비동기식 접속장치)

  • 오명훈;박석재;최호용;이동익
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.5
    • /
    • pp.321-334
    • /
    • 2003
  • Globally-Asynchronous Locally-Synchronous (GALS) systems are worthy of notice as an adequate architecture for a large scaled chip design with guaranteeing easy designs and functional confidence. In this paper, we suggest an advanced structure of the interface unit which is indispensable for GALS systems by using stoppable clocks. The proposed interface unit is composed of a sender module and a receiver module. The sender module can carry out data transmission partially without the relation to an internal clock. We have designed it with 0.25${\mu}{\textrm}{m}$ standard cell library at the gate level and simulated its operation to show performance improvement. Finally, we constructed all example circuit with the interface unit and proved the correct operation of it.

A Study of the Development of a Radial Pleat Module for Low Pressure Using an Ultrafiltration Membrane

  • Seo, Il-Gun;Shin, Se-Jong;Byoung-Ryul;Song, Hee-Yeol
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.7-11
    • /
    • 2002
  • A radial pleat module using a polysulfone membrane was developed. The permeation characteristics of the radial pleat module were compared with those of a flat plate module. The average module efficiency of the radial pleat module for the applied pressure range was 82% and was always greater than that of the spiral wound module. For the radial pleat module, in general, as the applied pressure increases, the flux increases and the rejection reduces. The concentration polarization causes the decrease of the flux for the long time operation. But it has been found that the radial pleat module is more efficient for the reduction of the concentration polarization because it has the more effective area per unit volume and can induce the turbulent flow in the module.

Development of a Prototype of a Module-Based Patient Monitor (모듈형 환자 모니터 시제품의 개발)

  • Woo, Eung-Je;Park, Seung-Hun;Kim, Kyung-Soo;Choi, Keun-Ho;Kim, Seung-Tae;Moon, Chang-Wook;Jun, Byung-Moon;Lee, Hee-Cheol;Kim, Hyung-Jin;Seo, Jae-Joon;Park, Jong-Chan
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.353-357
    • /
    • 1997
  • We have developed a prototype of a module-based patient monitor. In this paper, we describe the design methodology and specifications of the developed module-based patient monitors. The monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases, each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and $SpO_2$ with plethysmograph.

  • PDF

Combine Method of Small Unit Modules for Urban Regeneration Projects (도시재생을 위한 소형 유닛모듈 결합방법)

  • Kim, Kyoon-Tai;Jun, Young-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.243-244
    • /
    • 2018
  • This study focused on the fact that there are a lot of alleys in some areas of the Urban Renewal New Deal project. In this study, we proposed a method to construct a spatial module by combining small modules. It is expected that the combination of small modules developed in this way will help revitalize the New Deal of Urban Regeneration. In the future, additional joint details will be developed, structure review will be conducted.

  • PDF