• Title/Summary/Keyword: Unit method

Search Result 7,052, Processing Time 0.041 seconds

Operational Study of the Phosphoric Acid Type Unit Fuel Cell (인산형 단위 연료전지의 조업 연구)

  • Lee, Kapsoo;Kim, Hwayong
    • Journal of Hydrogen and New Energy
    • /
    • v.3 no.2
    • /
    • pp.63-69
    • /
    • 1992
  • Two unit cells were made and operated with oxygen and air as oxidants After 350 hours operation with oxygen, the open circuit voltage drop of unit cell was 30 mV and internal resistance increased. After 250 hours operation with air, the open circuit voltage drop was 130mV. And the open circuit voltage difference of two cases was 90mV. In order to improve the performance of the unit cell with air, the supplying method of the electrolyte and the mass transfer characteristics of the electrode should be studied.

  • PDF

Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel-Curtain wall (ALC 패널 커튼월의 패스닝 유닛의 단열 방법과 성능 평가)

  • Kim, Bongl-Joo;Kim, Kyeong-A;Park, Je-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.107-110
    • /
    • 2011
  • In this study is to improve insulation performance that are the most weak insulation part of fastening unit of the curtain wall. It was produced that thought out to minimize mullion and connecting part, and evaluated performance that make a layer of insulation in the middle by using vibration-proof rubber or silicon. Vibration-proof rubber insulation is 2.6℃~4.0℃ higher and silicon insulation is 2.4℃ higher than non-insulation. Therefore the insulating layer of fastening unit is necessary.

  • PDF

Fault Detection in an Automatic Central Air-Handling Unit (자동 공조설비의 고장 검출 기술)

  • Lee, Won-Yong;Shin, Dong-Ryul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.410-418
    • /
    • 1999
  • This paper describes the use of residual and parameter identification methods for fault detection in an air handling unit. Faults can be detected by comparing expected condition with the measured faulty data using residuals. Faults can also be detected by examining unmeasurable parameter changes in a model of a controlled system using a system identification technique. In this study, AutoRegressive Moving Average with seXtrnal input(ARMAX) and AutoRegressive with eXternal input(ARX) models with both single-input/single-input and multi-input/single-input structures are examined. Model parameters are determined using the Kalman filter recursive identification method. Regression equations are calculated from normal experimental data and are used to compute expected operating variables. These approaches are tested using experimental data from a laboratory's variable-air-volume air-handling-unit.

  • PDF

Identification of the air separation unit using subspace-based method

  • Lee, donghoon;sangchul Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.52.4-52
    • /
    • 2002
  • $\textbullet$ Introduction $\textbullet$ Wiener system identification problem $\textbullet$ Identification method $\textbullet$ Simulation $\textbullet$ Conclusions $\textbullet$ References

  • PDF

Optimization Method for the Design of LCD Back-Light Unit (LCD Back-Light Unit 설계를 위한 최적화 기법)

  • Seo Heekyung;Ryu Yangseon;Choi Joonsoo;Hahn Kwang-Soo;Kim Seongcheol
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.3
    • /
    • pp.133-147
    • /
    • 2005
  • Various types of ray-tracing methods are used to predict the quantity measures of radiation illumination, the uniformity of illumination, radiation performance of LCD BLU(Hack-Light Unit). The uniformity of radiation illumination is one of the most important design factor of BLU and is usually controlled by the diffusive-ink pattern printed on the bottom of light-guide panel of BLU. Therefore it is desirable to produce an improved (ideally, the optimal) ink pattern to achieve the best uniformity of radiation illumination. In this paper, we applied the Welder-Mead simplex-search method among various direct search method to compute the optimal ink pattern. Direct search methods are widely used to optimize the functions which are often highly nonlinear, unpredictably discontinuous, and nondifferentiable, The ink-pattern controlling the uniformity of radiation illumination is one type of these functions. In this paper, we found that simplex search methods are well suited to computing the optimal diffusive-ink pattern. In extensive numerical testing, we have found the simplex search method to be reasonably efficient and reliable at computing the optimal diffusive-ink pattern. The result also suggests that optimization can improve the functionality of simulation tools which are used to design LCD BLU.

Optimized Design of O-ring Groove in LPG Filling Unit Using Taguchi Experimental Method (다구찌 실험법을 이용한 LPG 충전노즐 O-링 그루브의 최적화 설계연구)

  • Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.40-46
    • /
    • 2006
  • In this paper, the optimized design of a rectangular O-ring groove has been analyzed for a maximum Cauchy stress and maximum strain using the Taguchi method. This method may efficiently optimize the design parameters for an O-ring groove of a LPG filling unit. The computed FEM results indicate that the optimized design parameters can only be drawn by nine experimental numbers of iterations when the Taguchi design technique has been employed with a finite element method. This means that the Taguchi design method is very useful for the optimization design of O-ring rectangular groove geometry. Based on the computed FEM results by the Taguchi design technique, the dimensions of a groove geometry are given as h=2.5 mm, d=2.74 mm, c=0.15 mm, and w=3.0 mm. In this study, the initial compression ratio of O-rings is recommended as 8.7% for a gas supply pressure of 18 $kg/cm^2$.

  • PDF

Comparisons of RDII Predictions Using the RTK-based and Regression Methods (RTK 방법 및 회귀분석 방법을 이용한 RDII 예측 결과 비교)

  • Kim, Jungruyl;Lee, Jaehyun;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.179-185
    • /
    • 2016
  • In this study, the RDII predictions were compared using two methodologies, i.e., the RTK-based and regression methods. Long-term (1/1/2011~12/31/2011) monitoring data, which consists of 10-min interval streamflow and the amount of precipitation, were collected at the domestic study area (1.36 km2 located in H county), and used for the construction of the RDII prediction models. The RTK method employs super position of tri-triangles, and each triangle (called, unit hydrograph) is defined by three parameters (i.e., R, T and K) determined/optimized using Genetic Algorithm (GA). In regression method, the MovingAverage (MA) filtering was used for data processing. Accuracies of RDII predictions from these two approaches were evaluated by comparing the root mean square error (RMSE) values from each model, in which the values were calculated to 320.613 (RTK method) and 420.653 (regression method), respectively. As a results, the RTK method was found to be more suitable for RDII prediction during extreme rainfall event, than the regression method.

Indeterminate Truss Structure Analysis using Topological Load Redistribution Method (위상학적 하중 재분배 방법을 이용한 부정정 트러스 구조 해석)

  • Choi, Won;Kim, Hanjoong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.59-68
    • /
    • 2015
  • Traditional structure analysis method is based on numerical matrix analysis to use the geometries consisting of the structure. The characteristics require a lot of computer memories and computational time. To avoid these weaknesses, new approach to analyze truss structure was suggested by adopting topological load redistribution method. The axial forces to be not structurely analyzed yet against outside loads were redistributed by using nodal equation of equilibrium randomly at each node without constructing global matrix. However, this method could not calculate the axial forces if structure is statically indeterminate due to degree of many indeterminacies. Therefore, to apply the method suggested in this research, all redundancies of truss structure were replaced by unit loads. Each unit load could make the deformation of a whole structure, and a superposition method was finally adopted to solve the simultaneous equations. The axial forces and deflections agreed with the result of commercial software within the relative error of 1 %, whereas in the case that the axial forces are relatively very smaller than others, the relative errors were increased to 2 %. However, as the values were small enough not to be considered, it was practically useful as a structural analysis model. This model will be used for structural analysis of truss type of large structure such as agricultural farming facility.

A study on the testing method of discolored tap water by spectrophotometer (분광측색계에 의한 착색 수돗물 시험방법 연구)

  • Dongheon Kim;Jonggeum Lee;Jiyoon Oh;Gitae Kim;Hangbae Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.187-202
    • /
    • 2023
  • This study focuses on the application of a new measurement method that quantifies the residual color of filtered water using a spectrocolorimeter after filtering the discolored substances. It was confirmed through the color and turbidity cross-test that the discolored substances cannot be measured effectively with the current legal color and turbidity test method. Therefore, the National Institute of Environmental Research's filter testing method, which involves filtering the sample through 0.45 ㎛ filter and visually inspecting the color, was improved. A membrane filter colorimetry (MFC) method was established by measuring the color difference (ΔE*ab(65)) of the filtered filter using a spectrophotometer and expressing it as filter color unit (FCU). Using the MFC method, the FCU for reference materials such as iron and manganese, as well as field samples, was measured. The results showed a high correlation with turbidity, and the color difference patterns varied depending on the type of reference materials and field samples. This indicates that the MFC method is an effective new measurement method of discolored tap water.